Special repair to alternate switching and conversion of OH LT line to UG cable of security light for Sunderji Marg and certain sectioned work under GE (Army) Suratgarh at Suratgarh Mil Stn
2021_MES_457741_1
GE (A) SOG - 28/21-22
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
SURATGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ARMY SURATGARH
₹75,000
Yes
24 Aug 2021
7 Jul 2021
9 Aug 2021
7 Jul 2021
7 Aug 2021
24 Jul 2021
Amount
Dismantling existing unserviceable Aluminium conductors, steel reinforced (ACSR conductor) from overhead lines on LT poles, of any type and any size complete all as specified and as directed by Engineer-in-charge
Dismantling existing unserviceable service bracket any type and any size on LT / HT poles complete all as specified and as directed by Engineer-in-charge.
Taking down street /security light fitting such as Energy saving light fitting 4x24 watt and 45/60/72/90 watt LED light fittings complete all as specified and directed by Engineer-in-Charge. Notes :- Ladder wheel shall be arranged by the Contractor.
Taking down LED security /street light fitting safely for reuse and refixing the same on new pole including connection with cable PVC insulated stranded copper conductor, 1100 volts grade, 2.5 sqmm 3 core size of ISI marked from security light to pole box along with accessories as directed by Engineer-in-charge. Notes:- (i) Any T & P and Ladder wheel required for the work shall be arranged by the Contractor. The rate of this aspect is included in this item and nothing extra shall be paid on this account.
Dismantling existing unserviceable cross-arms of M.S. channel or angle sections etc. of any size and type complete all as specified and as directed by Engineer-in-charge.
Dismantling and taking down insulators of any type and size complete all as specified and directed by Engineer-in-Charge.
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of poles etc including weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed by Engineer-in-charge
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation of poles, filling & mass concrete including necessary form work complete all as specified and directed by Engineer-in-charge .
S&F LED flood light of 150 watt with high pressure die cast housing with lens with lument output 6000K complete (including LED, drive and internally prewired) with on board 5 KV surge protection with 10 KV external SPD. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP 65 protection as per IS 10322-1982 (part-I) with latest amanedments and input voltage range 140-300V AC, frequency 50-60 Hz, P.F should be more than 0.9. The efficiency of LED luminaries system shall be more than 100 lumens per watt and FRLSH cable PVC insulated stranded copper conductor, 1100 volts grade, 2.5 sqmm x 3 core of ISI marked for light to terminal box complete including arrangement of mounting for flood light as required at site complete all as specified and directed by Engineer-in-charge. Make :- Syska cat part No SSK-BLS-N-150W Crompton Cat part No LFLN-150-CDL/60-M / Wipro cat part No LF07-152-090-50-V5 / Philips cat part No BVP122 LED 150 CW HE NB FG XTFCL S4 or equivalent in makes mentioned in Appendix 'A' here-in-after.
Suppyling, installing, testing and commissioning of factory made indoor type LT cubical panel board suitable for operation on 415 volts, 3 phase, 4 wire 50Hz supply system inlcluding bus bar chamber in centre ( vertically) and cable alley either side, outer shell shall be made out of 2.00mm thick CRCA sheet duly powder coated siemens gray shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back suitables to accomodate the following mentioned fittings and inner shell shall be made out of 2mm thick CRCA sheet duly powder coated & compartmentalized for each control gear including front openable single door with half nob type locking, inlcuding provision for taking out incoming and outgoing cables duly marked with reveted letter plated of appropriate size for each feeder / block cable, danger board, detachable plate at bottom for cable entry etc including double compression type cable gland with bottom frame made out of angle iron 40mm x 40mm x 5mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over and including 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body with and including following accesories :-
Contd/-… item No 10 Incoming (a) 300 Amps aluminium bus bar and Neutral - 01 Set (b) MCCB 200 Amps, 36 KA, 4 Pole, thermal Magnetic release type - 01 No Make - Legrand Cat Part No DPX³ 250, 420248 or equivalent in makes mentioned in Appendix 'A' here-in-after. Outgoing (a) Fixing only starter panel of size 500 x 500 x 150mm - 01 No (b) MCCB 63 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 04 No Make - Legrand Cat Part No DPX³ 160 420053 or equivalent in makes mentioned in Appendix 'A' here-in-after. (c) Digital Voltmeter flush type 0-500 Volts square type 96mm x 96mm - 01 No (d) Digital Ampere meter flush type 0-100 Amps square type 96mm x 96mm - 01 No (e) CTs 200/5 Amps - 01 Set (set of three) (f) Internal all links & control cable and indicators - set of three Note :- (i) Starter panel is already exist on ground and rates for fixing only considered for existing starter panel. Space for fixing of starter panel i.e. 500x500x150mm is also considered in panel. (ii) Cost of PCC, excavation and earth work is included in the unit rate of this item nothing extra shall be paid on this account.
All as per item No 10 above but comprising of following accessories:- Incoming (a) 100 Amps aluminium bus bar and Neutral - 01 Set (b) MCCB 63 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 01 No Make - Legrand Cat Part No DPX³ 160 420053 or equivalent in makes mentioned in Appendix 'A' here-in-after. Outgoing (a) Fixing only starter panel of size 500 x 500 x 150mm - 01 No (b) MCCB 63 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 01 No Make - Legrand Cat Part No DPX³ 160 420053 or equivalent in makes mentioned in Appendix 'A' here-in-after. (c) Digital Voltmeter flush type 0-500 Volts square type 96mm x 96mm - 01 No (d) Digital Ampere meter flush type 0-100 Amps square type 96mm x 96mm - 01 No (e) CTs 100/5 Amps - 01 Set (set of three) (f) Internal all links & control cable and indicators - set of three Note :- (i) Starter panel is already exist on ground and rates for fixing only considered for existing starter panel. Space for fixing of starter panel i.e. 500x500x150mm is also considered in panel. (ii) Cost of PCC, excavation and earth work is included in the unit rate of this item nothing extra shall be paid on this account.
Supply, install, commissioning of 15 metre high 20 sided polygon highmast lighting system fabricated out of BS-EN 10025 or equivalent 355 Mpa material in two sections, hot dip galvanised (single dip) internally & externally having uniform coating thickness of 85/ 65 micron for bottom & top section respectively as per BS 729 and with one longitudinal weld and having no circumferential weld suitable for wind velocity of 180 Km/hr as per IS -875 (Part-3) duly provided with accessories like head frame, steel wire rope 6mm dia (7/19 construction with central core SS) trailing cable double drum winch, galvanised lantern carriage arrangement suitable for 09 luminaires symmetrically and end finial. The mast shall have an integral power tool installed inside the base compartment for its operation as per manufacturers design/ details complete all as specified and directed by Engineer-in-Charge. Make : Bajaj / Philips / Crompton / GE or equivalent in makes mentioned in Appendix 'A' here-in-after (15 M height suitable for design condition specified above) Highmast light includes the following :-
Contd/-… item No 12 (i) Supply, and fixing of foundation bolts manufactured from special steel alongwith nuts, washers, anchor plates and templates etc as required as manufacturers recommendations suitable for design life not less than 25 years. (ii) Erection and commissioning of high mast with the help of suitable equipments and wiring of luminaries with all all copper conductor, cable of suitable size & providing flexible steel conduit pipe of ¾"mm dia for protection of cable (iii) Drawing, design and casting of suitable shallow foundation with RCC M-25 mix concrete for high mast considering the safe bearing capacity of soil as 10 tonne/ Sqm at 2.00 metre depth duly approved by GE - 01 Job (iv) Casting of suitable foundation with RCC M-25 mix concrete for panel as per manufacturers recommendations. (v) Supply and fix integral aviation obstruction light comprising of aluminium housing with polycarbonite enclosures - LED type - 02 Nos Make : Bajaj Cat No. BGAV 302 LED or equivalent in makes mentioned in Appendix 'A' here-in-after. (vi) Supply and installaton of control panel (KIOSK) (out door, double door) with 63 Amps capacity tripple pole & neutral (TPN) MCB incomer housing suitable for circuit for operation of mast including suitable control circuit for power tool motor complete as per manufacturer recommendations - 01 Job (vii) All necessary Excxavation and earthwork in any type of soil including returning, filling and removal of surplus soil to distance not exceeding 50 metre completed all as specified and directed by Engineer-in-Charge. (viii) Contractor shall submit Manufacturer guarantee certificate for a period not less than 05 years.
M&L for Construction of brick masonry valve pit of internal size 90cm x 90cm x 90cm including necessary excavation and earth work in soft/loose soil, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6 mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock complete all as specified and directed by Engineer - in - Charge Note :- (i) Brick wall shall be 23 cm thick built in cement mortar (1:4) (ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450mm from top shall be 20mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds. (iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls. (iv) PCC coping shall be 15 cm thick in cement concrete ( 1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC. (v) Three coats of white wash to internal surfaces of valve pit. (vi) Depth of valve pit shall be reckoned from the top of PCC in foundation.
S&F street light pole box of size not less then 300x200x105mm, made of high quality thermo plastic polystyrene, weather proof, dust, jet water proof, chemical, acid corrosion, impact, insulated & shock proof IP 65 for outdoor Installation with internallly embedded gasket (PUR) including MCB SP 6 Amps 01 No along with left side hinge door (notch arrangement not acceptable) & premoulded knockout all sides including back of the base must. The box fitted with 16 sqmm stud type terminal - 04 Nos including Elimex stud type TB 4 Nos complete all as specified and directed by Engineer-in-Charge. Note :- (i) Cost of flat iron clamp is deemed to included in unit rate of this items. Nothing extra shall be paid on this account. (ii) Size of junction box for different mafufacturer may slightly varried from size mentioned in description of item. Contractor has to provide junction box as per cat No mentioned against make of junction box. where cat No is not mentioned against any make, in that case junction box of size mentioned in description has to provide, if exact size of junction box is not available, then next higher size junction box has to be provided. Nothing extra shall be paid on this account.
S & F pre-stressed cement concrete pole, 9 metre long of cross section 102mm x 172mm at top and 102mm x 279mm at bottom, class 10, complying with requirements of IS-1678-1998 erecting truly in vertical position including painting of poles with two coats of synthetic enamel paint over a coat of primer in alternate strip of 30cm each in black and yellow colour up to 1.5 metre height from top of PCC pedestal/coping of poles including numbering of poles with synthetic enamel paint black in 80mm high letters over 150mm x 200mm yellow base made from synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. Note : PCC for foundation and earth work shall be measured and paid for separately.
M&L for road cutting for laying of water supply pipe lines upto 100 mm dia including returning filling in and making good surface with sub base, WBM, and premixed carpet etc. complete all as directed by Engineer-in-charge .
S&F 15mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors / trenches complete all as specified and directed by Engineer-in-charge.
S&F gun metal globe or gate valve 40mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge.
M&L cutting existing GI water main pipe line in position of 100mm bore and making connection of new pipe line of 40mm bore with & including fitting as required including excavation & earth work in any type of soil complete all as directed.
M&L for making connection from existing GI water pipe line of size 15mm bore and insertion of GI Tee of size 15x15x15mm including earth work making joints and jointing material etc complete all as specified and directed by Engineer-in-charge.
S&F 15 mm bore bib tap, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-charge.
S&F 15mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-charge.
S&F 450mm long PVC connection hot and cold type suitable for 15 mm bore with PTMT nuts on both sides complete all as specified and directed by Engineer-in-charge.
M&L for point wiring complete with 1.5 sqmm (nominal cross sectional area) FRLSH PVC insulated multistandard unsheathed copper conductor cable with colour coding drawn in and including concealed PVC rigid conduit medium grade 20mm dia with accessories such as pipe hooks, elbows, junction box, terminated in existing sunken box and covered with new 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including cutting chases in wall for conduits and making good the disturbed surfaces of wall and including 1.5 sqmm PVC insulated unshethed multistandard copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point, fan point, bell point controlled by one switch complete all as specified and directed by Engineer-in- charge.
All as per Srl item No. 24 above, but wiring with cable of cross sectional area 2.5 Sqmm (nominal area) multi-stranded copper conductor FRLSH, PVC unsheathed cable 1100 Volts shade for one switch socket combination 6 pin, 5/15 Amps on independent board including 2.5 Sqmm PVC insulated multistandard unsheathed copper conductor wire as earth continuity to common earth dolly.
S&F switch piano flush button 5 Amps single pole, one way complete all as specified and directed by Engineer-in-charge.
S&F ceiling rose surface bakelite 65mmx50mm with two or three terminal complete all as specified and directed by Engineer-in-charge.
S&F electronic fan regulator suitable for ceiling fan 1200mm/1400mm sweep, socket size, rotary type complete all as specified and directed by Engineer-in-charge.
S&F sheet metal plug & socket DB, SP, with a two pin and earth plug with socket, 230 Volts with & including one MCB SP ‘C’ Curve 10 kA, 20 Amps complete all as specified and directed by Engineer-in-charge. Make of DB :- Legrand Cat part No 507811or equivalent in makes mentioned in Appendix 'A' here-in-after. Make of MCB :- Legrand Cat Part No 408593 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F street light bracket made out of 32mm dia GI pipe light grade 1.2m long , bent to shape at 120 degree angle from vertical fixed along pole with and including two number of clamps made out of Flat iron 25mm x 6mm with nuts, bolts ,washers etc. duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge.
Supply, fixing and testing LED Street / Security light fitting of 60 Watt, 5700K - 6500 K (including LED drive and internally prewired) complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminum alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with IP -65 / 66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 300 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distortion THD(I) less than 15% ,cool white colour and lamp starting time should not be more than 10 second including 10 KV surge protection in built or external. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection, no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degree Centigrade to 50 degree Centigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 100 lumens per watt and must be certified by the LM-79 test report and including connection for street light from pole box with 1.5 Sqmm, 3 core PVC insulated stranded copper conductor FRLSH cable, 1100 Volts grade ISI marked including addition / alteration in bracket (if required) for fixing light fitting complete all as specified and directed by Engineer-in- charge. Make :- Syska Cat part No. SSK-SLF-F-60W-WL / Crompton Cat Part No LSTP-60-CDL-M / Havells Cat part No. ENDURA PEARLNEOSL60WLED757PASYTOPC / Wipro cat part No LR02-671-XXX-57-G2 or equivalent in philips.
Notes for srl Item No 31 :- (a) Tenderer shall submit test report of LED street light fitting from Government accredited test laboratory for LM - 79 and LM - 80 . (b) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. Contractor shall obtain warranty from the manufacturer of product on their letter head and submit the same to deparment alonwith his letter head. The product will be replaced free of cost in the following case :- (i) Manfacturing defects (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (c) All LED light/luminare must meet the provision laid down in IS - 16101 , 16102 Part -I/II ,16103 Part -I , 16104 ,16105 ,16106 , 16108/2012 and 15885 Part -II / Section 13. (d) Scope of work shall include supply and fixing street light fittings on street light bracket fixed on poles, If street light fitting requires to fixed on existing street light bracket and any addition alterration required in bracket for fixing street light, In that case cost of additional / alteration is included in the unit rate of this item, which also includes needful T & P and required accessories such as 1.5 sqmm, 3 core PVC insulated stranded copper conductor cable for connection from pole box to light fitting etc complete including making connection, testing etc complete .No extra payment is admissible on this account. (e) Light fittings shall be provided with 10 KV surge protection as mentioned in description of item. If 10 KV surge protection is not provided in light fitting for which cat part is mentioned in BOQ. Contractor has to provide light fitting with 10 KV surge protection without any extra cost to department. (f) Contractor shall write CA No on street light fitting with synthetic enamel paint which should be visible from ground level. Cost of the same is included in the unit rate of this item nothing shall be extra paid on this account.
S&F three phase automatic street light switch suitable for 5 KW load complete with Infrared sensor based NATURE SWITCH for automatic switching of street / security lights with three number two pole power contractors 40 Amps (Type - MU40-2P, Cs90119) with coil voltage 220 / 240 V and incoming MCBs single pole - 03 Nos, outgoing MCBs single pole - 03 Nos of rating 32 Amps & circuit wiring with single core multi stranded of size 10 Sqmm. Lighting switch operation should be based on natural light lux level. Required illuminance level for switching ON is < 30 Lux and for switching OFF > 10 Lux. The sensor should also have part night operation facility for 4,5,6,........11 & 12 hours. The sensor along with suitable power contactor (S), Incoming -outgoing MCB's should be enclosed in a Rust proof, electric shock proof, termite proof and FR grade thermoplastic polycarbonate enclosure with hinged lid confirming to IP66 protection class 2. The circuit should also have provision for manual operation (i.e. sensor By-pass option). The enclosure should be platform mounted and structure (made out of angle iron 40mm x 6mm minimum height 600mm from ground level) must be grouted in PCC (1:2:4) type B-1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm complete all as specified and directed by Engineer in charge. Make :- KAKATIYA ENERGY SYSTEM PVT LTD or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F in replacement three phase load 5 KW automatic street light switch using NATURE SWITCH for automatic switching of (ON/OFF) of all 3 phase of street / security lights and digital timer switch (L&T make or equivalent) for switching (ON/OFF) 2 phase (out of 3 phases) at pre-defined timing during night including contractors, 3 Nos incloming -outgoing MCBs of 20-25 Amps each & copper circuit wiring of minimum 10 sqmm. automatic switch ON of all 3 phase as at DUSK based on LUX (30 LUX) level of natural light. Automatic switch OFF all street light as DAWN based on the LUX level (10 lux of natural light). First phase (red) to operate full night, second phase (yellow) and 3rd phase (blue) can be switched OFF at a pre-define time during night (Say 11:00 PM) and switched ON again at a pre-defined time during early morning (Say 4.00 AM) before finally switching OFF automatically at DAWN. Bypass option for bypassing both sensor and timer. The infrared sensoned based nature switch along with digital timer should be enclosed in a Rust proof, electric shock proof, termite proof and FR grade thermoplastic polycarbonate enclosure with hinged lid (hensal make or equivalent junction box) confirming to IP66 protection class 2. The circuit should also have provision for manual operation (i.e. sensor By-pass option). The enclosure should be platform mounted and structure must be grouted in PCC (1:2:4) type B-1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm complete all as specified and directed by Engineer in charge. Make :- KAKATIYA ENERGY SYSTEM PVT LTD or equivalent in makes mentioned in Appendix 'A' here-in-after.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 40mm dia upto earthing test point/equipment fixed with required number of mild steel clamp made out of 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade of length 2.25 metre and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mmthick pre-cast RCC (1:2:4) type B-0 cover with 40mm x 40mm x 3mm MS angle iron frame, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 including taking down old earthing complete all as specified and directed by Engineer-in-charge. Notes :- (i) GI strip upto earth test point/equipment is included in this item. (ii) Outer edge of earth pit shall be 1.5 metre away from the outer edge of PCC chamber. (iii) Minimum weight of reinforcement for earth pit cover shall be 1 kg .
S&F water storage heater (geyser) of 25 ltr capacity, energy saving 5 star rating complete with fire retardant cable and 3 pin plug 15/16 Amp, including grouting 4 Nos bolts in PCC (1:2:4) block in wall and making good the disturbed surfaces matching with existing including making connection to elerctric supply complete all as specified and directed by the engr-in-charge. Make :- Havells Product code GHWAMJSIV025 (Model Monza Digi) or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply ,installation, testing and commissioning Refrigerator Direct cool, double door, capacity 360 ltrs , three star rating complete including electric connection complete all as specified and directed by Engineer-in-Charge. Make :- LG Mode No GL-T402JPZU or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F exhaust fan 300 mm sweep,900 RPM, metal body, trans air, with louver shutter suitable for operation on 230 volts, single phase , AC and connecting up including 2 core,1.0 sqmm PVC insulated & PVC sheathed copper conductor flexible cable drawn in flexible conduit complete all as specified & directed by Engr-in-charge. Make :- Havells Model No Terbo Jet SP or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F ceilling fan 1200mm sweep five star rating and making electric connections with 0.60RM long flexible cable of size 23/0.0076 mm complete all as specified and directed by the engr-in-charge complete all as specified and directed by Engineer-in-charge. Make : Havells Model No ES-50 Premium 5 or equivalent in makes mentioned in Appendix 'A' here-in-after. Note :- (i) MES No with stencil shall be marked on ceiling fan body using synthetic enamal paint. Cost of the same is included in the unit rate of this item.
M&L for Cutting holes in brick walls built in cement mortar for exhaust fan and making good dismantled portion complete all as specified and directed by Engineer-in-charge.
Supplying, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 70 sq mm 3.5 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
All as per item No 40 above but cable of cross sectional area 16 sq mm 4 core
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable and water supply / sewage pipe line etc. in soft / loose soil & getting out including taking out old brick or precast cable cover complete all as specified and directed by Engineer-in-Charge.
All as per serial item No. 42 here-in-above but depth exc 1.5 mtr & not exc 3mtr
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
M&L for dry sand (Tibba sand) and punning for cushioning to underground cable complete all as specified and directed by Engineer-in-charge Note: - For payment purpose thickness after punning shall be measured.
M & L for brick protection with old size sub class 'B' bricks laid flat, length of bricks across the route of underground cable all as specified and directed by Engineer-in-Charge.
S&F 100mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors / trenches complete all as specified and directed by Engineer-in-charge.
All as per item No 48 above but 40mm bore tubing
S&F Galvanized iron tubing, 50mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge. Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ (ii) Cost of flat iron clamp if required is included in the unit rate of this item. Nothing extra shall be paid on this account.
All as per item No 50 above but 32mm bore tubing
All as per item No 50 above but 15mm bore tubing
S&F Cast iron non return valve / reflux valve with rubber seat flanged type with by pass arrangement suitable for 100mm bore pipe, ISI marked, class PN-1.6 conforming to IS- 5312/2004 with stainless steel spindle, CI gate with brass nuts, bolts, washers and jointing with necessary ruber gasket etc complete all as specified and directed by Engineer-in-charge.
S&F GI flanged bend of size 100mm bore with gasket and nut bolts complete all as specified and directed by Engineer-in-charge.
Submersible UPVC column pipe 4" (113mm, 3mtr length) medium grade complete all as specified and directed by Engineer-in-charge. -------------------------------------------------------------------- Note :- A sum of Rs. 18100/- will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 30 (Schedule of Credit) of Tender documents.
Gupta Suppliers
GURDEEP SINGH AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .