| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹4.2 LQualified Make: LIFESECURE
Model: Lifesecure, LS-324 E 173 SECTOR 4 DSIIDC INDUSTRIAL AREA BAWANA DELHI 110039 NORTH WEST DELHI DELHI 110039 | NORTH DELHI | DELHI | 110039 | Make: LIFESECURE
Model: Lifesecure, LS-324 | L1 | Qualified | |
| 2 | L2₹4.3 L+₹12,320 (2.94%)Qualified Make: FIRE SQUAD
Model: FIRE SQUAD & FSW-SP-9 257 257 AGGARWAL CITY MALL PLOT NO 3 ROAD NO 44 PITAMPURA DELHI NORTH WEST DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | Make: FIRE SQUAD
Model: FIRE SQUAD & FSW-SP-9 | L2 | Qualified | |
| 3 | L5₹4.8 L+₹55,616 (13.3%)Qualified Make: SHOOTFIRE
Model: SHOOTFIRE_MSFE_SP_9_WATER 19 20 VARDHMAN INDUSTIRAL ESTATE LBS MARG VIKHROLI WEST MUMBAI MAHARASHTRA 400083 | MUMBAI SUBURBAN | MAHARASHTRA | 400083 | Make: SHOOTFIRE
Model: SHOOTFIRE_MSFE_SP_9_WATER | L5 | Qualified | |
| 4 | L7₹4.9 L+₹72,160 (17.2%)Qualified Make: LIFEGUARD
Model: (United Fire Equipment's Pvt. Ltd) Lifeguard LG-109 AMBALA HARYANA 134003 | AMBALA | HARYANA | 134003 | Make: LIFEGUARD
Model: (United Fire Equipment's Pvt. Ltd) Lifeguard LG-109 | L7 | Qualified | |
| 5 | L8₹4.9 L+₹72,512 (17.3%)Qualified Make: Safeguard
Model: SAFEGUARD 347 DEEPALI PITAMPURA DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | Make: Safeguard
Model: SAFEGUARD | L8 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
7 Jul 2018, 10:00 amClosed
Portable Fire Extinguishers IS 15683 Average Turn Over of Last 3 Years 40 Lakh (s) Experience with Gov. Required 3 Year (s) Portable Fire Extinguishers IS 15683 ( 352 ) Technical Specifications Specification Specification Name Values Allowed Values Generic Conformity to Standard IS:15683:2006 With Latest Amdmnt. - Type Stored Pressure Stored Pressure
Gas Cartridge Type Extinguishing Media Water Based Water Based
Foam Based
Powder Based
Carbon Dioxide Based
Clean Agent Expellant Medium N2 Based (Stored Pressure) CO2 Cartridge Based
N2 Based (Stored Pressure)
CO2 Extinguishing Medium Constructional Foam Based Extinguishing Media NA - Powder Based Extinguishing Media NA - Clean Agents Based Extinguishing Media NA - Foam Based Fire Extinguisher Capacity(Ltrs) NA 2
4
6
9
NA Powder Based Fire NA 1
2
NA 1/4 Extinguisher Capacity (Kg) Carbon Dioxide Based Fire Extinguisher Capacity (Kg) NA 2
3
4.5
NA Water Based Fire Extinguisher Capacity 9 9 Clean Agents Fire Extinguisher Capacity (Kg) NA 2
NA Weight of Filled Portable Fire Extinghuisher (Kg) 12.5 Rechargebale true - Color Coding Red - Fire Extinguisher Suitable for Class -A Fire true - Fire Extinguisher Suitable for Class -B Fire false - Fire Extinguisher Suitable for Class -C Fire false - Fire Extinguisher Suitable for Class -D Fire false - Fire Extinguisher Suitable for electrical Fire false - Performance Operating Temperature (° C) +5° C to + 55° C - Test pressure/Burst Pressurire Extinguisher except CO2 for water/Foam/Powder type fire extinguisher Test Pressure >=20 Bar
Burst Pressure >=55 Bar - Test pressure/Burst pressure for CO2 type Extinguisher (write NA if not applicable) 35 - Discharge Range for Extinguisher (Meters) >=2 for Class-A - Effective Discharge Time for Fire Extinguisher
Min (Seconds) 45 2/4 Fire Rating for Class -A Fire Extinguisher 4A - Fire Rating for Class -B Fire Extinguisher NA - Certification BIS Marking Yes - CM/L No.* with Validity Period CM/L 2927672 DT:-13/10/2018 - Availability of Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to specification YES - Test Report No. 842516 - Test Report Date 14/10/2014 - Name of the Lab FTRL - Address of the Lab DELHI - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Poonam Sangwan 181201
10 Inf DOU PIN - 909010 C/o 56 APO Akhnoor 352 15 EMD Required No ePBG Required No
244766
GEM/2018/B/34809
Portable Fire Extinguishers IS 15683
15 days
Jammu And Kashmir; Jammu
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Portable Fire Extinguishers IS 15683 Average Turn Over of Last 3 Years 40 Lakh (s) Experience with Gov. Required 3 Year (s) Portable Fire Extinguishers IS 15683 ( 352 ) Technical Specifications Specification Specification Name Values Allowed Values Generic Conformity to Standard IS:15683:2006 With Latest Amdmnt. - Type Stored Pressure Stored Pressure | - | - | - |
| Gas Cartridge Type Extinguishing Media Water Based Water Based | - | - | - |
| Foam Based | - | - | - |
| Powder Based | - | - | - |
| Carbon Dioxide Based | - | - | - |
| Clean Agent Expellant Medium N2 Based (Stored Pressure) CO2 Cartridge Based | - | - | - |
| N2 Based (Stored Pressure) | - | - | - |
| CO2 Extinguishing Medium Constructional Foam Based Extinguishing Media NA - Powder Based Extinguishing Media NA - Clean Agents Based Extinguishing Media NA - Foam Based Fire Extinguisher Capacity(Ltrs) NA 2 | - | - | - |
| 4 | - | - | - |
| 6 | - | - | - |
| 9 | - | - | - |
| NA Powder Based Fire NA 1 | - | - | - |
| 2 | - | - | - |
| NA 1/4 Extinguisher Capacity (Kg) Carbon Dioxide Based Fire Extinguisher Capacity (Kg) NA 2 | - | - | - |
| 3 | - | - | - |
| 4.5 | - | - | - |
| NA Water Based Fire Extinguisher Capacity 9 9 Clean Agents Fire Extinguisher Capacity (Kg) NA 2 | - | - | - |
| NA Weight of Filled Portable Fire Extinghuisher (Kg) 12.5 Rechargebale true - Color Coding Red - Fire Extinguisher Suitable for Class -A Fire true - Fire Extinguisher Suitable for Class -B Fire false - Fire Extinguisher Suitable for Class -C Fire false - Fire Extinguisher Suitable for Class -D Fire false - Fire Extinguisher Suitable for electrical Fire false - Performance Operating Temperature (° C) +5° C to + 55° C - Test pressure/Burst Pressurire Extinguisher except CO2 for water/Foam/Powder type fire extinguisher Test Pressure >=20 Bar | - | - | - |
| Burst Pressure >=55 Bar - Test pressure/Burst pressure for CO2 type Extinguisher (write NA if not applicable) 35 - Discharge Range for Extinguisher (Meters) >=2 for Class-A - Effective Discharge Time for Fire Extinguisher | - | - | - |
| Min (Seconds) 45 2/4 Fire Rating for Class -A Fire Extinguisher 4A - Fire Rating for Class -B Fire Extinguisher NA - Certification BIS Marking Yes - CM/L No.* with Validity Period CM/L 2927672 DT:-13/10/2018 - Availability of Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to specification YES - Test Report No. 842516 - Test Report Date 14/10/2014 - Name of the Lab FTRL - Address of the Lab DELHI - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Poonam Sangwan 181201 | - | - | - |
| 10 Inf DOU PIN - 909010 C/o 56 APO Akhnoor 352 15 EMD Required No ePBG Required No | - | - | - |
Exempted
7 Jul 2018
23 Jun 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_244766.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .