Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹46.7 L+₹2.9 L (6.67%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 bidder | |
| 3 | L3₹49.4 L+₹5.7 L (13.0%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 bidder | |
| 4 | L4₹51.5 L+₹7.7 L (17.7%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 bidder |
Tender Value
₹46.7 L
EMD Value
₹93,400
Closing Date
24 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 862 EWS
GE 862 EWS PIN-913862 C/o 56 APO
Special repairs to Bldg No T35 and T36 at Jhanger, T15A at Narian, And/Altn of LT overhead line to UG cable and connected items at 80 Bde Camp and certain minor works of AGE B/R Dett-A under GE 862 EWS
2022_MES_541741_1
GER-36/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS
As per tender docuemts
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹93,400
Yes
17 Sept 2022
29 Jul 2022
26 Aug 2022
29 Jul 2022
24 Aug 2022
12 Aug 2022
Amount
Sch 'A' Part-I (B/R works) Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing rubbish off the premises complete all as specified and directed.
M&L for vitrified tiles light shade (premium quality) 10 mm thick (square/ rectangular) polished, area of each tiles n exc 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface, laid over and including 15 mm thick screed bed in cement mortar (1:4) complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 350x250x7mm or 450x350x7mm thick, (premium quality) on vertical surface such as dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 10 mm thick backing layer of cement plaster in cement mortar (1:4) complete all as specified and as directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (premium quality) Square/rectangular, area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 15mm thick screed bed in cement mortar (1:6) complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floor and paving n exc 15 cm thickness below or above the ground level complete all as specified and directed.
M&L for 50mm thick PCC type C-2, (1:3:6) (using 40mm graded stone aggregate) as in plinth protection, laid in slope 1:12 from outer edge of the wall, finished even and fair, laid in alternate bays including providing 6mm wide joints throughtout thickness of plinth protection in concrete bays and in between walling and plinth protection, joints filled mastic filling comprising of one part of heated bituminous 85/25 and 3 parts of sand (all by weight) complete all as specified and directed.
Taking down chowkhats or frames (without taking off shutters from the frames) n.exc 1.5 Sqm each and removing to store complete all as specified and directed
Taking down shutteror frames exc 2 Sqm and removing to store complete all as specified and directed.
S&F for factory made 2nd class hard wood 35 mm thick plain framed panelled shutters (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F for factory made 35 mm thick 2nd class hard wood glazed and skelton shutters open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed.
M&L for stone walling of random rubble masonry, uncoursed, well bonded, bedded and soilidly hearted, built in cement mortar (1:6), complete all as specified and directed.
M&L for stone walling of random rubble masonry (except stones, using old unserviceable stone after cleaning), uncoursed, well bonded, bedded and soilidly hearted, built in cement mortar (1:6), complete all as specified and directed.
M&L for extra over stone walling for hammer dressing to face stones and dressing of face beds with maximum depression on face from straight edge held against the dressed surface n exc 20 mm for lime or sand stone and joints, as specified, of random rubble walling, uncoursed or brought upto courses complete all as specified and directed.
Taking down cement plaster, any description on brick or stone or cement concrete surfaces including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 20 mm thick in cement mortar (1:6) on stone masonry finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 20 mm thick in cement mortar (1:4) on stone masonry (external surface) finished even and smooth without using extra cement complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for Use & waste of formwork to sides and soffits of floor of roof beam, shelfs, plinth beam etc and similar works in rough finished flat surface of concrete complete all as specified and directed.
M&L for Use & waste of formwork to soffits of suspended slab such as roof slab, floor slab, landing and similar works in rough finished flat surface of concrete complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for mild steel TMT bars 6mm to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends as in stirrups, spacers and binders including binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for reinforced Cement concrete (1:1 ½ :3) of nominal mix (using 20 mm graded stone agg.) in beams, deck slab, shelfs, plinth beams, etc complete all as specified and as directed.
S&F for factory made MS tubular Box type window (double rebate and double shutter) of MS rolled steel section conforming to IS-1038 and shall be ISI marked manufactured by ISI approved manufacturer, openable frames shall be fabricated of sections as approved by Engr-in-Charge, corner welded to form a solid fused welded joint, handles shall be of z section welded with openable frame box steel section used in outer frame, shutter frame and central frame shall be ERW secton of 16 gauge with fixing lugs to be fixed as per provision of IS-1038 except that top lugs shall not be provided , all shutters of windows shall be provided with 4 Nos friction free hinges, 2 Nos 75 mm tower bolts to each leaf of window one at top and one at bottom welded on 3 mm thick steel sheet piece of suitable size which shall be in turn welded to z section of steel window to provide suitable arrangement of using tower bolt. Glazed, gauzed window , mild steel casement stays 300 mm with hinged joint and two plates with studs complete all as specified with all fittings and fixtures without glazing bars including 3mm thick sheet glass ordinary quality and stainless steel wire mesh of 0.36mm nominal dia and average width of aperture 1.4 mm etc complete all as specified and directed.
M&L for framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290, Gde E-165 complete all as specified and directed.
S&F for 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.
S&F for Second class hard wood(Hollock) small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary labours; articles n exc 200 cu. cm each, complete all as specified and directed.
M&L for plain cement concrete type B-1 , 1:2:4 (using 20mm graded stone aggregate) as in coping, benching, hold fasts, water troughs, bed block, surface channel and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
S& F for stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperature 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F for 150 mm long extruded aluminium anodised handles fabricated type anodised complete all as specified and directed.
S&F for 200mm long aluminium anodized barrel tower bolts extruded section all as specified and directed.
S&F for 200mm long aluminium alloy, anodised, sliding door bolt, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
M&L for preparation of new steel surface exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified.
M&L for preparation of new wooden surface exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of cement primer complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of wall care putty complete all as specified and directed.
M&L for preparation of newplastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
M&L for 100mm thick PCC (1:4:8), type D-2 using 40mm graded stone aggregates as in sub base of floors and mass concrete etc complete all as specified and directed.
S&F for Curtain rod of wooden finishes of 25mm dia fency type complete including hanging hooks/brackets/end caps of length 1.5 mtr to 1.8m each complete as in repair all as specifed and directed.
M&L for 4mm thick designer cement fibre ceiling board in ceiling fixed with screw as per manufacturers instructions , laid over and including hot dipped galvanised iron in post grid with 24mm wide T section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33 mm thick galvanised steel sheet of size 24 x 32 x 300 mm spaced at 12 mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of GI wire 4 mm dia to be fixed by approved rawl plug, level adjusters and screws etc. The last hanger at the end of each main runner shall not be greater than 450 mm from adjacent wall flush fittings of 1200 mm long screws Tee with (double stiching) to interlocked between main runners at 600 mm centre to centre from 1200 x 600 mm modules cross tee longer than 600 mm modules to be formed by fittings 600 mm long cross tee, tee perimeter wall angle shall be of 0.45 mm thick galvanised steel of size 19 x 19 mm and 300 mm long of white colour all as per insturctions including dismantling of existing board etc complete all as specified and directed.
Taking down aluminium doors/ window /partition of any type including all fittings and fixtures complete all as spricified and directed by Engr-in-Charge.
S&F for anodised aluminium frame for doors/ windows/ ventilators with one or more rebates including joining cleat for fixing including powder coating n.less than 50 micron any colour etc. complete all as specified and directed.
M&L for Anodised aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, mortice lock, 1 No, floor door stopper, anodised aluminium snap beading, screws etc including powder coating of any colour (thickness of powder coating not less than 50 micron) complete all as specified and directed.
S&F for sheet glass 5.5 mm thick, ordinary quality and fixed with aluminum & rubber beading in square exc 0.5 sqm in each pane complete all as specified and directed.
M&L for pre laminated 12mm thick interior grade both side decorative choice lamination fixed to aluminium doors or similar works as pannel inserts complete all as specified and directed.
S&F for Rotational moulded polythylene water storage tank (ISI marked multilayer) with float valve, plastic lid cover, double layered, cylindrical vertical with closed top, hoisted and fixed in position of capacity 500 ltrs including dismantling old unserviceable tank and making connections inlcuding suitable GI wash out, over flow, nipple and including 15mm bore ball brass valve with union (two nos each) screwed for iron pipe and fixed complete all as specifed and directed.
M&L for 15mm dia bib tap cast copper alloy with crutch or butterfly handle, chromium plated, fancy type, screwed for iron pipe complete as in repair as in repair all as specified and directed.
S&F for vitreous China water closet (squatt pan) Orrisa pattern 580x440 mm size pan, white, with front or back inlet with integral 'foot rests including PCC bedding in (1:2:4) and making good disturbed floor connecting to trap and flush pipe as in repair complete all as specified and directed.
S&F for PVC low level flushing cistern 10 ltrs capacity white with inlet ball valve, float valve and handle including providing & fixing MS angle iron brackets, PVC flush pipe complete as in repair all as specified and as directed.
S&F for 15 mm bore galvanised iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors after taking down old unserviceable GI pipe of 15mm dia with all fittings etc complete all as specified and directed.
S&F for 20 mm bore galvanised iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors after taking down old unserviceable GI pipe of 20mm dia with all fittings etc complete all as specified and directed.
S&F for 100 mm dia grating (CP) with waste hole complete all as specified and directed.
S&F for Brass chromium plated shower rose 125mm with or without swivel joints, any size inlcuding fixing to steel pipe or union complete as in repair all as specified and directed.
S&F for Brass chromium plated tubular towel rail 20 mm dia "D" type 60 cm long between flange aluminium anodised complete as in repair all as specifed and directed.
S&F for stop valve, cast copper alloy, screwed for high pressure with crutch or butterfly handle, screwed suitable for 15mm bore iron pipe or for union both ends as in repair complete all as specified and directed.
S&F for 15mm stop valves, cast copper alloy screwed down high byut fancy type, chromium plate pressure with long shank and cup and fixed (concealed type) complete all as specified and directed.
S&F for PVC connection 15 mm x 450 mm including PTMT nuts at both ends screwed for iron pipe of 15 mm bore complete all as specified and directed.
M&L for 15mm dia gun metal, gate/globe valve with iron wheel head screwed on both sides for iron pipes complete as in repair all as specified and directed.
M&L for 20mm dia gun metal, gate/globe valve with iron wheel head screwed on both sides for iron pipes complete as in repair all as specified and directed.
S&F for 110mm dia PVC (SWR) pipes type 'B' single socketed in any length with rubber ring joints, laid in trenches or in floor after taking down old unserviceable pipe complete all as specified and directed.
S&F for 75mm dia PVC (SWR) pipes type 'B' single socketed in any length with rubber ring joints, laid in trenches or in floor after taking down old unserviceable pipecomplete all as specified and directed.
S&F for 75mm dia PVC (SWR) pipes type 'B' single socketed in any length with rubber ring joints as in wall fitted with clamps after taking down old unserviceable pipecomplete all as specified and directed.
M&L for 110mm dia PVC SWR bends complete all as specifed and directed.
M&L for 75mm dia PVC SWR bends complete all as specifed and directed.
S&F for PVC (SWR) junction single (Single 'Y') equal or unequal 110mm complete all as specified and directed.
S&F for 75mm dia PVC (SWR) vent cowl complete all as specified and directed.
S&F for PVC(SWR) floor trap 75 mm bore complete as in repair all as specified and directed.
S&F for soap dish fixed with including chromium plated brass screws and wooden plastic cleats complete all as specified and directed.
S&F for vitreous China wash basin, white, flat back, size 550x 400mm including 15mm bore pillar tap cast copper alloy, PVC connection 15mm length 450mm, low density PVC waste pipe complete as in repair all as specified and directed.
S&F for Vitreous china bowl urinal flat back of size 465x355x265mm white (minimum) including, waste pipe, coupling, floor trap, incuding necessary fitting complete as in reapir all as specified and directed by the Engineer-in-Charge.
S&F for push type any colour high pressure of PTMT screwed for iron pipe and fixed suitable for urinals(minium weight 15mm-50 gms) complete all as specified and directed.
M&L for 3.0 mm thick frosted sheet glass ordinary quality and glazing with oil putty and steel pins or wooden beads in squares not exceeding 0.50 square metre in each pane, complete all as specified and directed.
S&F for 15mm bore pillar tap fancy type cast copper alloy with chromium plated screwed down, screwed for iron pipe or for brass ferrule and fixed complete as in repair all as specified and directed.
M&L for preparation of old decorated brick/concrete plastered/un-plastered surfaces by brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and applying one coat of cement base paint etc complete all as specified and directed.
M&L for preparation of old decorated brick/concrete plastered/un-plastered surfaces of walls, pillars, cornices etc by brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and applying distempering with two coats of oil emulsion distemper incl one coat of wall care putty 1.5mm thick etc complete as diercted by GE all as specified and directed.
Dismantling of wrought iron or mild steel work of any tyoe and size not otherwise provided complete all as specified and directed
Dismantiling of framed trusses n.exc 10 mtr span of any type complete all as speicfied and directed
S&F for Roof trusses (framed), trussed, purlins, cranes gantries, , rails and fastening and heavy brackets framing (beam, tea, angle, channel or flat section) including distance pieces, cleats, etc. conforming to Fe-410-W (Gde - E-250) quality A complete all as specified and directed.
Fixing only for Roof trusses (framed), trussed, purlins, cranes gantries, , rails and fastening and heavy brackets framing (beam, tea, angle, channel or flat section) including distance pieces, cleats, etc. complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nanital or similar pattern roof coverings complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coated GI based corrugated steel 0.50mm thick of approved colour having tensile strength 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coated GI based plain steel 0.50mm thick of approved colour having tensile strength 550 MPa as in ridges, hips, valley gutters, fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed.
M&L for preparation of old plastered steel surfaces applying one coat of synthetic enamel paint of any discription having width or girth exc 10cm complete all as specified and directed.
M&L for 40mm cement concrete 1:2:4, type B1 (using 20mm graded aggregates) as in top surface of hardstanding etc. complete all as specified and directed.
Taking down chowkhats or frames exc 1.5 Sqm and n.exc 4 Sqm each (without taking off shutters from the frames) and removing to store complete all as specified and directed
S&F for mild steel work as in wind ties and similar work oincluding necessary drilling and bolting confermint to Fe-410-O of Fe310-o complete all as specified and directed.
S&F for mild steel screw bolts (machine made) with hexagonal or square head at one end and screwed the other with washers of length exc 5cm and n exc 10 cm and slote 6 to 20mm dia complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar (1:6) on fair faces of brick or concrete surface, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar (1:4) on brick masonry (external surface) finished even and smooth without using extra cement complete all as specified and directed.
S&F for pressed steel door frame of size 125x60 mm with one or more rebates incl necessary fixing lugs, hinges, lock and strike plate etc including back filling to chowkhats in PCC (1:3:6) type C-0 using 12.5mm graded stone agregate complete all as specified and directed.
S&F for 100mm long butt hinges medium weight cold rolled mild steel complete all as specified and directed.
M&L for Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21100mm long (2 no.) suitable handle (1no.) complete all as specified and directed.
S&F for door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg Aluminium (extruded section) body complete all as specified and directed.
S&F for brass mortice lock vertical type 100mm long with 4 levers complete all as specfied and directed.
Sufrace excavation not exceeding 30cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed.
M&L for Brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for RCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in slab supported on walls, beams and columns in floor, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for 20mm thick granite of any type machine cut bedded and jointed with gray cement slorry and pointed with white cement including grinding and polishing complete all as specified and directed.
S&F for sink with drainage board made out of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in CM to dwarf wall or including fixing cantilever brackets and connecting union to pipe, over all size 915mm x 460mm, bowl size 410mm x 330mmx 160mm complete all as specified and directed.
S&F for 32mm dia waste coupling of PTMT (half or full threaded) (Minimum weight 32mm-45gms/40mm-60 gms) complete all as specified and directed.
M&L for PCC (1:4:8), type D-2 using 40mm graded stone aggregates as in sub base of floors, mass concrete pole/stay complete all as specified and directed.
M&L for reinforced Cement concrete type B1, 1:2:4 (using 20 mm graded stone agg.) in foundation inlcuding rafts, fotings, foundation beams, plinth beams, base for columns etc basement slab under reamed piles and mass concrete complete all as specified and as directed.
M&L for reinforced cement concrete type B-1, 1:2:4 (using 20mm graded crushed stone aggregate) as in column, pillars, piers, struts etc complete all as specified and directed.
M&L for formwork to sides of columns, post, struts, piers and stenchions for fair finished surface complete all as specified and directed.
Sch 'A' Part-II (E/M works) Taking down carefully copper/ aluminum point wiring (light, fan, socket or power) complete, including all fittings such as switches, ceiling roses, pendants, regulators sockets etc.) removing material from the site and making good the disturbed surfaces of walls, floor or ceiling etc. to match with existing specifications complete all as specified and directed.
M&L for point wiring for one light point/fan/bell/buzzer point controlled by one-one way switch with 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor unsheathed in and including non metalic rigid PVC casing & caping of 25mm width (Medium grade double locking system) complete with all acessories including PVC sunk box ISI marked for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly including making good the diturbed surfaces compete all as specified and directed. (Note:- Three run of copper conductor of required size and one run of casing capping measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth)
Description all as per Serial item No 107 above but for one 5 pin 6 Amp socket outlet on same board controlled by one 6 amp switchcomplete all as specified and directed.
Description all as per Serial item No 107 above but for one 5 pin 6 Amp socket outlet on independent board controlled by one 6 amp switch complete all as specified and directed.
Description all as per Serial item No 107 above but for one 6 pin 16/6 Amp socket outlet independent with 2.5 sqmm PVC insulated FRLS multistraind copper cable with 2.5 sqmm single core multistraind FRLS copper cable as earthling lead complete all as specified and directed.
M&L for Switch piano, flush type single pole, one way 6 Amp, 240 volts complete all as specified and directed.
M&L for Socket outlet 2 in 1 , 3 pin 5 amp 230 volts flush type complete all as specified and directed.
S&F for switch piano flush type single pole one way 15 amps 240 volts complete all as specified and directed.
M&L for switch outlet combination 2 in 1, 5 &15 Amp 230 volts flush type complete all as specified and directed.
M&L for Ceiling rose two to three terminal (65 x 50mm), PVC/ polycarbonate insulated body complete all as specified and directed.
M&L for Ceiling fan regulator elctronic, stepped type, hum free suitable to control speed of fan from 0 to 100% rotary type five step 240 volts AC complete all as specified and directed.
M&L for lamp holder insulated body PVC/ Polycarbonate type with back plate suitable for batten/angular/pendent fittings including LED lamp 9watt complete all as specified and directed.
M&L for LED Tube light fitting, complete with 1x 20 watts, 220V, AC decorative box type with driver, holder in and including LED tube light connection complete prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core and connector block etc and necessary fixing arrangement at any height complete as in repair all as specified and directed. (Make :- Havells cat No LHEXARP7SN1W020 or equivalent in Crompton/Philips).
M&L for sheet metal enclosure MCB distribution board, double door single pole and neutral with IP-66 protection single phase 240 volts 04 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete as in repair all as specified and directed. (Note:- MCBs will be measured separately.)
M&L for MCB single pole, 240 volts any rating from 5 to 40 amps, 'C' series/curve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
M&L for MCB single pole & neutral 240 volts any rating from 5 to 40 amps, 'C' series/curve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
S&F for LED street light fitting 30 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, parismatic polycarbonate cover with individual LED lense with IP 65 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting and after taking down old unserviceable light fittings of any type complete as in repeir all as specified and directed (Make:- Crompton, Model No FREEDOM NEO LSTS-30-CDL-M or Havells, Cat No ENDURA PEARL NEO SL30WLED757PASYTOPC)
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
M&L for 40mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls for protection complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2009 including testing on completion complete all as specified.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth not exceeding 10sqm on plan for foundation, laying of cable and foundation of poles stays and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in trenches including spreading, leveling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing of excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and directed.
M&L for dry sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm deep after laying and stretching jointing and testing the cable complete all as specified and as directed. (Note: Punned thickness of sand shall be measured and paid).
M&L for brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat, size 230mm x 115mm x 75mm, complete all as specified and as directed.
Supply, install, commissioning and testing vertical storage water heater (geyser) 5 star rated as per BEE norms electricity operated suitable for 230 volts, 50 hz, AC supply system complete with porcelen/ glass coated insulated heating element, copper tank, external thermostat and docorative of capacity 25 Ltrs, including 01 No. CP connection for hot water and 01 No PVC connection for cold water including fixing on suitable bolts and nuts complete all as specified and directed.
S&F for environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head 10 watt 6000 K inbuilt LED luminaire comprising of high brightness LEDs, IP54 protection including connecting electricaly using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm complete as in repair all as specified and directed. (Make :- Havells Cat part No HEXAFT10WLED857SSYMBOPC or equivalant of Crompton Greaves /Philips)
S&F for exhaust fan of 450mm sweep, heavy duty, 1200 RPM electrical operated 230 Volts AC single phase with metal body with all accessories and louver etc complete all as specified and directed.
M&L for GI bracket pipe of size 40mm dia light grade of 1.2 mtr long bent to shape hot or cold suitable for street street light fitting and making the one end of GI pipe bracket suitable for fixing of street light fittings of any type and the GI bracket shall be fixed on wall/pole surfaces by providing suitable MS iron 25x4 mm clams 2 Nos of 25 cm long duly to the bracket pipe and painting to MS clamps and fixing with necessary suitable nuts, bolts and washers complete as in repair all as specified and directed.
Dismantling of overhead ACSR conductor of any size including removing of PG clamps, jumpering etc and removing unserviceable conductor from site complete all as specified and directed.
Dismantling of old unserviceable stay assembly including stay wire complete with necessary demolition of concrete excavation and earth work as reqd and removing the same from site complete all as specified and directed.
Dismantling of old unserviceable LT (PCC) concrete pole of any size with necessary demolition of concrete foundation including excavation earth work as reqd complete all as specified and directed.
Dismantling of cross arms of MS channel of angle section etc complete fixed on RCC/steel tubular poles carefully including separating and setting a side serviceable cross-arms for reuse in the work and removing unserviceable cross arms compete all as specified and directed
Dismantling of insulators of any type & size from position including separating insulators complete all as specified and directed.
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 10 sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 25 sqmm 4 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 50 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 95 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 120 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
M&L for 50mm dia galvanized steel tubing light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls for protection complete all as specified and directed.
M&L for steel tubular swaged poles errected to truly vertical position with 6mm thick mild steel base plate of size 300mm x300mm, welded to Pole, B-118 finial taper plug, bolts, nuts and screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II, type 410-SP-31 (9m long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint internally and portion embedded in concrete, making five black and white bands at lower portion of pole each 300mm wide at 300mm spacing alternately and marking pole number. with black paint at suitable height including taking down old unserviceable broken steel pole of 9 mtr long complete all as specified and directed. (Note :- Necessary excavation of earth work, removing, returning filling in, PCC foundations of poles, coping etc shall be measured and paid separately)
M&L for PCC 1:3:6 (nominal mix) type C-1 using 20mm graded crushed stone aggregates, as in all around the pole and including necessary formwork complete all as specified and directed.
M&L for PCC 1:2:4 (nominal mix) type B-1 using 20mm graded crushed stone aggregates, as in coping of poles and the like complete including weathering, slightly round or chamfered angles and throating including necessary formwork complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and depth exceeding 1.5m but not execding 3m depth for foundation of poles/stays and getting out in soft / loose soil complete all as specified and directed.
Complete removal of existing paint from the steel tubular swaged pole of 9 mtr height without removing accessories and preparation of surfaces for repainting the poles with and including two coats of synthetic enamel paint upt 1.50mtr height having alternative white and yellow strips of 30cm height each, including one coat of aluminium paint to the remaining part of pole (i.e above 1.50 mtr height) and its corss arms bracing, support and all steel members complete etc all as specified and directed.
M&L for PVC junction box of size 300mm x 250mm x 150mm weather proof fixing arrangement etc using suitable clamps nuts, bolts etc for accommodating and four strip aluminium bus bar of (capacity 63 Amp, inlcuding and mounted on epoxy insulator 01 setand MCB SP 10 Amps -01 No comple all as specified and directed.
S&F for LED street light fitting 45 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, parismatic polycarbonate cover with individual LED lense with IP 65 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting complete as in repair all as specified and directed (Make:- Crompton, Model No FREEDOM NEO LSTS-45-CDL-M or Havells, Cat No ENDURA PEARL NEO SL45WLED757PASYTOPC)
Cutting/trimming of tree branches under OH HT electric line including cleaning upto 2.00 mtr horizontal distance on both sides of OH electric line from ground level of the poles including removing all creepers small bushes etc of under OH line upto 60 mtr each sapn and depositing the cut branches upto 50mtr from the pole including taking shut down in writing with all safety measure as per electric rules complete all as directed by Engineer-in-Charge. (Note :- Materials/T&P like Axes, rope, gloves,safety harness etc. and the like will be provided by the contractor without any extra cost )
Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m deep below normal ground level connected to and including 25X4mm thick galvanised iron strip by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mmc/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion complete all as specified and directed. (Note:-Earth strip and protection pipe upto board is included in the rate quoted)
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
M/S. Choudhary Dewan Chand And Sons
M/s Anil Engineers & Builders
M/S Narinder Pal Choudhary
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .