Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹33.8 LAccepted-AOC | L-1 | Accepted-AOC Accepted being L-1 | |
| 2 | L-2₹36.2 L+₹2.1 L (6.15%)Rejected-AOC R O Y K PURA QAZIGUND ANANTNAG 192221 J K | ANANTNAG | JAMMU AND KASHMIR | 192221 | L-2 | Rejected-AOC Not accepted being L-2 | |
| 3 | L-3₹38.1 L+₹4.0 L (11.7%)Rejected-AOC | L-3 | Rejected-AOC Not accepted being L-3 | |
| 4 | L-4₹41.3 L+₹7.2 L (21.0%)Rejected-AOC | L-4 | Rejected-AOC Not accepted being L-4 | |
| 5 | L-5₹43.2 L+₹9.1 L (26.6%)Rejected-AOC BRAJANATHCHAK TOWNSHIP HALDIA HALDIA HALDIA | MEDINIPUR EAST | WEST BENGAL | 721605 | L-5 | Rejected-AOC Not accepted being L-5 |
Tender Value
₹30.5 L
EMD Value
₹61,000
Closing Date
28 Mar 2022, 10:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PARTAPUR
GE PARTAPUR
PROVN OF OPEN TRAINING SHED WITH PATHWAY AT BASE CAMP AND SPECIAL REPAIR TO BLDG T-45 (OR LIVING) INCLUDING REWIRING AT OMP AT KHALSAR UNDER GE PARTAPUR
2022_MES_512728_1
GE/P-71/2021-22
Open Tender
Civil Works
Works
180 days
GE PARTAPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE PARTAPUR
₹61,000
Yes
18 Apr 2022
9 Mar 2022
29 Mar 2022
21 Mar 2022
28 Mar 2022
21 Mar 2022
60 days
Amount
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in hard and dence soil, complete all as specified and as directed by Engineer-in-charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth and getting out in hard and dence soil, complete all as specified and as directed by Engineer-in-charge.
M& L filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled, and blinded with earth and rammed including watering , complete all as specified and as directed by Engineer-in-charge.
M & L Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface , complete all as specified and as directed by Engineer-in-charge.
Providing PCC type C2 1:4:8 using 40 mm graded crushed stone aggregate as in foundation etc, complete all as specified and as directed by Engineer-in-charge.
M&L for Pre-cast cement concrete Type C1, 1:3:6 (using 20mm graded crushed stone aggregate) block masonry with solid blocks, exc. 10 cm in width and setting in CM 1:6, complete all as specified and as directed by Engineer-in-charge.
M & L Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, complete all as specified and as directed by Engineer-in-charge.
M& L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips , complete all as specified and as directed by Engineer-in-charge.
Same as per item No 8 above, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, complete all as specified and as directed by Engineer-in-charge.
M & L for RCC M-30 as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed by Engineer-in-charge.
M & L for RCC M-30 as in columns, pillars, piers, posts and struts , under-reamed piles and mass concrete complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter , complete all as specified and as directed by Engineer-in-charge.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions, complete all as specified and as directed by Engineer-in-charge.
M & L for Vitrified coloured ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bed or bedding layer of mortar for laying floor finishes in CM 1:4 , complete all as specified and as directed by Engineer-in-charge.
M&L for glazed ceramic coloured tiles vertical surfaces (300x200mm) x 7mm thick on vertical surfaces such as skirting, dado or risers or steps etc. set and jointed in cement slurry and pointed in white or coloured cement to match the surfaces etc, complete all as specified and as directed by Engineer-in-charge.
Providing cement concrete type C-1, 1:3:6 ( using 20mm graded cresded stone aggregate), 75 mm thick as in plinth protection laid in bays not exceeding 2 Sqm each and finishing even and fair on top without using extra cement with 6mm wide joints throughout the thickness of plinth protection in concrete bays and in between the walling and plinth protection, filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand ( all by weight), complete all as specified and as directed by Engineer-in-charge.
M&L for rendering 15mm thick on fair faces of brick work or concrete surface finished even and smooth (without using extra cement) in CM 1:4 including watre proofing compound, complete all as specified and as directed by Engineer-in-charge.
M&L preparing plastered or unplastered new surface, and applying two coats of cement base paint over a coat of white wash on walls, complete all as specified and as directed by Engineer-in-charge.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and as directed by Engineer-in-charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point , complete all as specified and as directed by Engineer-in-charge.
M& L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and as directed by Engineer-in-charge.
M&L for 75 mm thick PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate as in sub base , complete all as specified and as directed by Engineer-in-charge.
M&L sand filling under floors or in foundation including watering and consolidation, complete all as specified and as directed by Engineer-in-charge.
M&L machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment , complete all as specified and as directed by Engineer-in-charge.
Demolition of tiles of any description or thickness in floors, complete all as specified and as directed by Engineer-in-charge.
M&L for 25mm thick plain cment concrete 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in floor , complete all as specified and as directed by Engineer-in-charge.
M & L for non skid ceramic tile 7 to 8mm thick (square / rectangular) area of each tile exc 0.11 Sqm but not exc 0.18 Sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement match, 15mm thick screed bed or bedding layer of mortar for laying floor finishes in CM 1:6, complete all as specified and as directed by Engineer-in-charge.
Dismantling wall and ceiling board (fibre, pulp, insulation etc) or insulation board/slabs/ blanket any thickness including cover filllets, complete all as specified and as directed by Engineer-in-charge.
M&L pre-laminated particle board 9mm thick, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination as in wall, fixed with screws to timber frame work, complete all as specified and as directed by Engineer-in-charge.
M&L pre-laminated particle board 9mm thick, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination as in ceiling, fixed with screws to timber frame work, complete all as specified and as directed by Engineer-in-charge.
Dismantling timber framed in fillets, rails, posts rafters, purlines, etc under 40 Sq cm in section, complete all as specified and as directed by Engineer-in-charge.
M&L second class softwood plain filllets, rectangular in section, clean swan, secured with nails exc 13 and n.exc 25 Sqcm, complete all as specified and as directed by Engineer-in-charge.
M&L second class softwood plain fillets, rectangular in section, clean swan, secured with nails exc 3 and n.exc 6 Sqcm, complete all as specified and as directed by Engineer-in-charge.
Dismantling of plain of corrugated steel sheeting any gauge, thickness including Nainital or similar pattern roof covering, complete all as specified and as directed by Engineer-in-charge.
S&F Galvanised MS sheeting of 0.63mm thick corrugated ISI Marked and made of shakti with two cougation side laps and fixed with J hooks two framed work with PVC and steel washers as in roof & wall with Zinc coating of 275, complete all as specified and as directed by Engineer-in-charge.
S&F plain, galvanised MS sheeting of 0.63mm thick in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275, complete all as specified and as directed by Engineer-in-charge.
Takingdown chowkats or frames with shutters (without taking offf shutters from the frames) not exc. 1.5 sqm each, complete all as specified and as directed by Engineer-in-charge.
S&F steel windows with side hung shutters including projecting type hinges with steel handles and steel peg stay complete all without glazing bars devetailed or welded, complete all as specified and as directed by Engineer-in-charge.
S&F for sheet 3.0mm thick, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of newly steel surface of any description not other wise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of old painted surface of any description not other wise described, over 10cm width or girth and applying two coats of synthetic enamel paint, complete all as specified and as directed by Engineer-in-charge.
Taking down carefully damaged copper/aluminum point wiring (light/fan/socket or power) complete including fixture and fittings such as switches, ceiling roses, cassing & capping, pendants, sockets, light fitting etc and making good disturbed surfaces of wall/roof , complete all as specified and as directed by Engineer-in-charge.
Taking down of MCB DB/TPN 4way/12way including mcb sp and spn and making good of wall , complete all as specified and as directed by Engineer-in-charge.
M&L for Point wiring with 1.5 Sqmm (nominal area) copper conductor FRLS cable (multi-stranded) PVC insulated and unsheathed electric cable 1100 volts drawn through PVC casing and caping of suitable size (as per conductor run) with all fittings and accessories and including PVC insulated unsheathed electric cable 1100 volts 1.5 Sqmm (multi-stranded) copper conductor single core (green colour) as continuous earth wire connected to common earth dolly including 50mm deep box made out of 2nd class hard wood board of suitable size and shape and other boxes for mounting light fittings etc covered with 3mm thick plastic laminated Hylum ISI marked for following complete all as specified and directed by Engr-in-Charge. Note:- Screw used for fixing TW baords, casing and caping ceiling rose, square blocks etc should be nickel cadmium screws.
One light point controlled by one 5 Amps one way switch
One 3 pin socket outlet 5 Amps on independent board
One 3 pin socket outlet 5 Amps on same board
M&L point wiring for power point with 4.0 sqmm (nominal area) copper conductor FRLS cable ( multi-stranded) PVC insulated and unsheathed cable conductor 1100 Volts drawn through PVC casing capping of suitable size(as per conductor run) with all fittings and accessories and including PVC insulated unsheathed electric cable 1100 volts 2.5 Sqmm (multi-stranded) copper conductor single core (green colour) as continuous earth wire connected to common earth dolly including 50mm deep box made out of 2nd class hard wood board of suitable size and shape and other boxes for mounting light fittings etc covered with 3mm thick plastic laminated Hylum ISI marked for following complete all as specified and directed by Engr-in-Charge. Note:- Screw used for fixing TW baords, casing and caping ceiling rose, square blocks etc should be nickel cadmium screws.
S & F Switch piano flush button single pole one way 5 Amps, 240 Volts complete all as specfied and directed by Engr-in-Charge.
S&F switch socket combination 3 pin, 5 Amps, 2 in 1 flush type (multipurpose) suitable for 2 pin / 3 pin plug complete all as specified and directed by Engir-in-Chage.
S&F switch socket combination 2 in 1, 3 pin, 5/15 Amps, flush type (multipurpose). Complete all as specified and directed by Engr-in-Charge.
S&F surface and wall mounted LED batten with polycarbonate housing and integrated electronic driver tube light fitting 22W, 4 ft long, 220 Volts , and connecting to ceiling rose with three core twisted flexible copper cable of suitable size complete all as specified and directed.
S&F Ceiling rose surface backelite ISI marked with 3 terminal including connecting and testing complete all as specified and directed.
S&F MCB DB sheet enclosure,Double door type, single pole and neutral 240V with 200 Amp rated bus bar suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete confirming to IP 42/43 without MCB and with enclosure blank plates for unused way suitable for 8 way complete all as specified and directed.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning all as specified and directed.
Supply and fixing MCB SPN 240V, 10KA 'C' curve 40 Amp current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick burried directly in ground not less than 2.25m deep below normal ground level (with the top edge of the plate not less than 1.50 m below the normal ground level) connected to GI earth wire 4 mm by means of GI bolts, nuts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I connected to earthing test point with and including necessary excavation and earth work in any strata PCC pit 1:3:6 type C-1, 20mm bore medium grade GI pipe for watering 15mm bore light grade pipe for GI wire protection and funnel including 40mm thick RCC slab cover and testing on completion all as specified and as directed.
Taking up the existing cables from trenches of any size all as specified and directed.
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 10 sqmm 2 core complete all as specified and directed.
Sand cushioning for under ground cable 8 cm before laying the cable and 15 cm after laying and streching the cable complete all as specified and directed by Engineer-in-Charge.
M&L Un-reinforced precast factory made concreate cable covers, class LV type-I, with flat size 250x150x40 mm Complete all as specified and directed.
Supply and fixing IP 65 villa solar LED gate light 1 watt (LED solar pillar light ) with build in solar panel LED light and lithium battery with charger controller. Make- Havells cat no : VILLA 1W 5700K solar gate light
M/S BHAT ENGINEERS
M/S LIBE & CO
M/S GEE AAR and SONS ENTERPRISES
M/S MA CONSTRUCTION Co
osho traders
Rampal Singh Contractor
M/S MUNEER HASSAN AKHON
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .