| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.5 CrAccepted-AOC | ₹1.5 Cr | 1 | Accepted-AOC being lowest |
| 2 | 2₹1.6 Cr+₹9.2 L (6.16%)Rejected-Finance | ₹1.6 Cr+₹9.2 L (6.16%) | 2 | Rejected-Finance other than lowest |
| 3 | Rejected-Technical | - | - | Rejected-Technical not enlisted in a(ii) category |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
13 Jan 2020, 6:00 pmClosed
Chief Engineer Lucknow Zone
HQ CE Lucknow Zone 17 carriappa Road Lucknow 226002
PROVISION OF SEWER LINE AND ALLIED WORKS FOR KLP ACCN 508 ABW (PHASE-II OF II PHESES ) AT CHHEOKI ALLAHABAD
2019_MES_294449_1
CELZ/ALD/T-04 of 2019-20
Open Tender
Civil Works - Others
Lump-sum
180 days
CHHEOKI ALLAHABAD
As per NIT
7 documents required · 7 mandatory
₹1,000
GE(P) Allahabad
₹2.2 L
Yes
11 Feb 2020
2 Nov 2019
15 Jan 2020
2 Nov 2019
13 Jan 2020
12 Dec 2019
Amount
Sch 'A' Part-I (Building Work) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Construction of Plant operator room complete all as shown on drawings and specified.
Total amount of Sch 'A' Part II (Site clearance, excavation and earth work)
Total amount of Sch 'A' Part III (Internal Water Supply)
Total amount of Sch 'A' Part IV (Internal Electrification)
Total amount of Sch 'A' Part V (SEWAGE COLLECTION SYSTEM)
Total amount of Sch 'A' Part VI (WASTE WATER STABLIZATION POND (OXIDATION TANK))
(Provisional sum of Rs 1,60,000.00) for :- (i) Provn of soak pit in ordinary soil, foundation in PCC 1:3:6, wells of honey combed and solid in M-25 conc, brick work in CM, RCC cover slab in M-25 filling with brick bats complete of size : 1.80 m diameter x 3.0 m effective depth all as per details shown in drawing No. TD-576 - Sh 1/2 & 2/2. - (06 Nos)
Schedule 'A' Part - VII (Miscellaneous Items for B/R & E/M Works) Note - This Schedule is not pre-priced by MES and the pre - priced rate indicated as "Rs 0.00 under col.5 signifies this fact only.
SEWAGE NETWORK LLDPE Sedimentation tank conventional designed to carry sewage and sullage water, with and including vent shaft, connection etc for 20 users complete all as per manufacturer instruction and as specified and directed. MAKE :- Sintex, plasto, SFMC, supreme.
INTERNAL ELECTRIFICATION Point wiring complete for One light/Fan/Exhaust Fan point controlled by one switch with PVC insulated and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of required colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
Point wiring complete for one 5 Pin 5 Amp switch Socket outlet point on an independent board, with PVC insulated and unsheathed FRLS CABLE 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed MS boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of required colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
Point wiring complete with PVC insulated and unsheathed, FRLS cable 2.5 sqmm (nominal area), ISI marked, stranded copper conductor single core including ISI marked 20mm dia PVC conduit concealed in wall and MS conduit in roof/floor slab & ceiling, pressed GI concealed MS boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete, including 2.5 Sqmm, FRLS cable PVC insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty pipe shall be used without any extra cost.
Exhaust Fan high quality plastic body, resistant to colour change with anti static properties (ventil air) 200 mm sweep 35 watt with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side (outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable rubber insulated from ceiling rose to exhaust fan motor complete all as specified and directed.
Energy saving sleek and light weight LED batten with high brightness 20 watt LED rod retrofit type with a nominal system output of 85 lim/watt(min) with PF not less than 0.9 providing homogenous illumination, suitable for surface mounting with 4000 K integrated high efficiency LED drive>85% non corrosive complete all as specified and directed.
Energy saving 2 feet LED batten with high brightness 9 Watt LED retrofit rod with a nominal system output of 85 lim/watt(min) with PF not less than 0.9 providing homogenous illumination, suitable for surface mounting with 4000K integrated high efficiency LED drive>85% non corrosive complete all as specified and directed.
Energy saving pressure die-cast aluminium IP 66 roadway luminaire with high power 14 WATT LED with a nominal system output of 85 lum/watt(min) with PF not less than 0.9 as light source with toughened glass including two core flexible copper wire of 1.5 sq mm from ceiling rose to the connector of fitting, connection wires not to be more than 2.5 in length and made out of GI tubing 35/40 mm dia/suitable dia light grade bend to shape security light fitting with necessary MS clamps 35/40 mm wide and 6 mm in thickness in suitable length not more than 30 cm and Max length of pipe 1.5 Mtr long with one code of anti corrosive primer and two coats aluminium paint including nuts, bolts and washers complete all as specified and directed. Make Philips cat part No BRP042 LED 14 CW MR S1 PSU GR or equivalent model of makes mentioned in Appendix 'D'.
Ceiling fan 1200 mm sweep single phase 230V AC, five star rating and ISI marked alongwith steel down rod and connecting up the fan to ceiling rose including provn of three core flexible copper cable of size 1.5 Sqmm not less than 0.5 mtr long for connection complete all as specified and directed. Make: Bajaj model Electra 50 or equivalent model of makes mentioned in Appendix 'D'.
MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, powder coated complete without MCB and with enclosure blank plates for unused way suitable for 4 way complete all as specified and directed.
MCB single pole 6 amp rating 'B' Series, 10 KA, 240 Volts, AC complete all as specified and directed.
MCB SPN, 16 amp rating 'B' Series, 10 KA, 240 Volts, AC complete all as specified and directed.
Supply, laying, jointing and commissioning of LT XLPE cable PVC insulated, PVC sheathed, armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor passing through pipe/road crossing in ducts, on poles, trenches etc of size 10 Sqmm 2 core complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground.(earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr. below ground level connecting to galvanised earth lead wire 4.0 mm dia upto 7.5 meters long connected by means of bolts, check nuts and washers of GI and earth strip protected by provision of GI pipe medium grade, 15 mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron 40 x 40 x 3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hard / dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection and testing on completion complete all as specified and directed. Note: (i) The cost of excavation and earth work, PCC pit and pit covers, funnel and watering pipe, wire mesh, charcoal dust and common salt, 40mm dia, medium grade, GI pipe as protection to GI Strip and GI Strip as 32 x 6 mm (main earthing lead from earth electrode to test point length not less than 7.5mtrs) shall be deemed included in the unit rate for earthing. (ii) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
SEWER COLLECTION SYSTEM Cast iron sluice valve of size 100 mm heavy duty both ends flanged class PN 1.6, ISI marked with high tensile brass spindle, cast iron hand operated wheel and cap top, nuts, bolts, washers including 3 mm thick rubber gasket joints etc complete all as specified and directed.
Construction of fly ash brick masonry valve pit chamber of size 900 mm X 900 mm X 900 mm (internal dimensions) including necessary excavation & earth work, 100 mm thick PCC (1:4:8) type D-2 as in foundation, 230 mm thick fly ash brick work in cement mortar (1:4), 12 mm thick rendering in cement mortar (1:4) on internal surface of valve pit and mild steel sheet cover of 6 mm thick and angle iron of size (50 x 50 x 6) mm frame around of valve pit, sheet welded on all four corners, locking arrangement with pad lock of size 50 mm brass, 6 leavers and in duplicate key (Make - Godrej ) or equivalent make as approved by GE complete including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface complete all as specified and directed.
Granular class-B type bed to DWC pipe including packing under and haunching against the sides of pipes after they are laid & tested with local sand complete all as specified and directed.
DWC pipe Class-SN8 (Structured Wall polyethelene Piping systems) of 150 mm internal dia (Pipe with online/offline coupler and elastomeric sealing ring) with non-smooth External Annular Corrugated and Smooth Internal Surfaces (Double Wall) for non-pressure underground Sewerage & Drainage application confirming to IS:16098-2013 including all materials, labours, T&P required for proper completion of work complete all as directed and specified.
DWC pipe Class-SN8 (Structured Wall polyethelene Piping systems) of 200 mm internal dia (Pipe with online/offline coupler and elastomeric sealing ring) with non-smooth External Annular Corrugated and Smooth Internal Surfaces (Double Wall) for non-pressure underground Sewerage & Drainage application confirming to IS:16098-2013 including all materials, labours, T&P required for proper completion of work complete all as directed and specified.
Supply, align & Install the precast, pre-channeled, pre-benched circular reinforced concrete manholes with S.F.R.C. cover (heavy duty, HD-20 grade designation) of size 1.0 M internal dia at bottom and 0.56 m dia at top and 0.8 M deep Type-I manhole conforming to I.S. 12592 and collector DWC inlet 150/200, DWC outlet 150/200 pipes & future pipes connecting over granular sub base as specified and shown on drawing no. STD/173, sheet no. 1/1. The manholes shall be precast with M-30 concrete grade building in with end caps where shown or necessary, including cost of all materials labours and T&P incl Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS :10910 on 12mm dia steel bar conforming to IS :1786 having minimum cross section as 23X25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification marks to be visible even after fixing including fixing in manhole with 23x23x15 cm cement conctrete block 1:3:6 using 20 mm graded aggregate complete all as directed and specified. MAKE:- KK SPUN INDIA LTD, NPCA, BHRC PIPE INDUSTRIES, KK MANHOLE AND GRATING CO. Pvt. LTD.
All as per item no. 8.20 here-in-before of circular type manhole type-I but depth more than 0.8 m upto 2.0 m complete all as directed and specified. Note:- Various manholes of different depths are to be provided at site as per site requirement. The tenderer shall quote rates for per meter of depth beyond 0.8m. Actual payment shall be made based on actual depth provided at site for one meter depth or part thereof for each manhole. Tenderer should note this aspect while quoting rates against this item.
All as per item No 8.20 here-in-before but size of manhole 1.20 M internal dia at bottom and 0.56 m dia at top and 1.0 M deep Type-II manhole as per drawing no. STD/172, sheet no. 1/1.
All as per item no. 8.22 here-in-before of circular type manhole type-II but depth more than 1.0 m upto 2.8 m complete all as directed and specified. Note:- Various manholes of different depths are to be provided at site as per site requirement .The tenderer shall quote rates for per meter of depth beyond 0.8m. Actual payment shall be made based on actual depth provided at site for one meter depth or part thereof for each manhole. Tenderer should note this aspect while quoting rates against this item.
All as per item No 8.20 here-in-before but size of manhole 1.50 M internal dia at bottom and 0.56 m dia at top and 1.3 M deep Type-III manhole as per drawing no. STD/171, sheet no. 1/1.
All as per item no. 8.24 here-in-before of circular type manhole type-III but depth more than 1.3 m upto 4.2 m complete all as directed and specified. Note:- Various manholes of different depths are to be provided at site as per site requirement .The tenderer shall quote rates for per meter of depth beyond 0.8m. Actual payment shall be made based on actual depth provided at site for one meter depth or part thereof for each manhole. Tenderer should note this aspect while quoting rates against this item.
Trenchless boring under road, pavement hard standing by using trenchless technology with ultra sounding technology with machine for pipe upto 200mm dia complete all as directed and specified
M/s NSA Engineering Corporation
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .