Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAdmitted-Finance 0 | ₹32.4 L | L1 | Admitted-Finance |
| 2 | L2₹33.3 L+₹83,580 (2.58%)Admitted-Finance 00 VILL RATI KA NAGLA SIKANDRA RAO ROAD INDUSTRIAL HATHRAS UTTAR PRADESH 204212 | HATHRAS | UTTAR PRADESH | 204212 | ₹33.3 L+₹83,580 (2.58%) | L2 | Admitted-Finance |
| 3 | L3₹36.0 L+₹3.6 L (11.1%)Admitted-Finance FLAT NO 402 4TH FLOOR BLDG NO 31 HANSGEET CO OP HSG SOCIETY PANT NAGAR GHATKOPAR E MUMBAI 400 075 | MUMBAI SUBURBAN | MAHARASHTRA | 400075 | ₹36.0 L+₹3.6 L (11.1%) | L3 | Admitted-Finance |
| 4 | L4₹38.2 L+₹5.7 L (17.7%)Admitted-Finance | ₹38.2 L+₹5.7 L (17.7%) | L4 | Admitted-Finance |
| 5 | L5₹54.7 L+₹22.3 L (68.8%)Admitted-Finance 10 SHANTI VIHAR RUDRAPUR UDHAM SINGH NAGAR UTTARAKHAND 263153 | UDAM SINGH NAGAR | UTTARAKHAND | 263153 | ₹54.7 L+₹22.3 L (68.8%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S VIJAY SINGH L2 | DKS ENGINEERING WORKS L4 | M/S Amar Enterprises L5 | A S ENTERPRISES L1 | RAMESH ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00In replacement of Supply, laying and testing of cable XLPE insulated, screened PVC bedded, galvanised steel stripped or wire armoured electric cable heavy duty with stranded aluminium conductor , 11KV grade of following size complete all as specified and directed. Note :- (i) Old cable and joint kit retrieved under this item shall be contractor property and necessary amount as per schedule of credit shall be deducted from contractor due payment. (ii) Excavation, earth work, cable joint, sand cushioning, protection cover and pipe shall be measured and paid for separately under respective items of this schedule | ||||||||
| 1.01 | -do- 95 Sqmm X 3 core | 180 | RM | 930 ₹1,67,400 | 980 ₹1,76,400 | 1,000 ₹1,80,000 | 700 ₹1,26,000 Lowest | 1,050 ₹1,89,000 |
| 1.02 | -do- 120 Sqmm X 3 core | 200 | RM | 1,060 ₹2,12,000 | 1,350 ₹2,70,000 | 1,150 ₹2,30,000 | 900 ₹1,80,000 Lowest | 1,145 ₹2,29,000 |
| 1.03 | -do- 185 Sqmm X 3 core | 150 | RM | 1,360 ₹2,04,000 | 1,450 ₹2,17,500 | 1,450 ₹2,17,500 | 1,200 ₹1,80,000 Lowest | 1,410 ₹2,11,500 |
| 2.00 | Excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre deep and getting out in soft/loose soil complete all as specified and directed. | 150 | Cum | 80 ₹12,000 Lowest | 80 ₹12,000 Lowest | 150 ₹22,500 | 100 ₹15,000 | 300 ₹45,000 |
| 3.00 | Returning filling in foundation / trenches including spreading leveling, watering and well ramming in layers not exceeding 25cm thick in soil complete all as specified and directed by Engineer-in-Charge. | 95 | Cum | 30 ₹2,850 Lowest | 50 ₹4,750 | 100 ₹9,500 | 40 ₹3,800 | 210 ₹19,950 |
| 4.00 | Removing surplus soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point.Complete all as specified and directed. | 55 | Cum | 30 ₹1,650 | 50 ₹2,750 | 50 ₹2,750 | 20 ₹1,100 Lowest | 190 ₹10,450 |
| 5.00 | M&L for Sand cushioning for under ground cable with locally available sand for protection of cable 8cm before laying cable and 15cm deep over the cable including spreading and consolidations, complete.
Note :- Punned thickness will be measured and paid. | 36 | Cum | 430 ₹15,480 | 450 ₹16,200 | 150 ₹5,400 Lowest | 450 ₹16,200 | 630 ₹22,680 |
| 6.00 | Supply and laying un-reinforced precast concrete cable cover class HVP type 2 with peak size 450 mm x 180 mm x 40 mm complete all as specified and directed by Engineer-in-Charge. | 2,500 | Each | 28 ₹70,000 Lowest | 40 ₹1,00,000 | 35 ₹87,500 | 35 ₹87,500 | 42 ₹1,05,000 |
| 7.00Material and labour for maintenance of power transformer /step down transformer 11 KV of different capacity including following :- (a) Oil leakage checked and necessary rectification, (b) All loose connection (power & control) are checked and rectification, (c) IR value of HV to body, LV to body & HV to LV to be checked by megar with submit. Note :- (i) All the work shall be done as per instruction by the Engr-in-charge. (ii) Obtaining a shutdown and a work permit is mandatory before performing any work on distribution/ Power Transformer. (iii) Plug made/mention in registr of IR value. | ||||||||
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
20 Aug 2026, 6:00 pmClosed
CWE (AF) BAMRAULI
HQ CWE (AF) BAMRAULI
REPAIR MAINT OF 33 KV MAIN RECEIVING STATION AND 11 KV STATION INCL PREVENTIVE MAINT OF TRANSFORMER RMU VCB AND CONNECTED WORKS OF EXTERNAL ELECTRIFICATION SYSTEM AT AF STATION BAMRAULI
2026_MES_780402_1
87619/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BAMRAULI
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE (AF) BAMRAULI
₹80,000
7 Sept 2026
23 Jul 2026
27 Aug 2026
23 Jul 2026
20 Aug 2026
6 Aug 2026
23 Jul 2026 - 30 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1In replacement of Supply, laying and testing of cable XLPE insulated, screened PVC bedded, galvanised steel stripped or wire armoured electric cable heavy duty with stranded aluminium conductor , 11KV grade of following size complete all as specified and directed. Note :- (i) Old cable and joint kit retrieved under this item shall be contractor property and necessary amount as per schedule of credit shall be deducted from contractor due payment. (ii) Excavation, earth work, cable joint, sand cushioning, protection cover and pipe shall be measured and paid for separately under respective items of this schedule | |||||
| 1.01 | -do- 95 Sqmm X 3 core | 180 | RM | 2.25 | ₹405 |
| 1.02 | -do- 120 Sqmm X 3 core | 200 | RM | 3.25 | ₹650 |
| 1.03 | -do- 185 Sqmm X 3 core | 150 | RM | 4.25 | ₹637.5 |
| 2 | Excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre deep and getting out in soft/loose soil complete all as specified and directed. | 150 | Cum | 5.25 | ₹787.5 |
| 3 | Returning filling in foundation / trenches including spreading leveling, watering and well ramming in layers not exceeding 25cm thick in soil complete all as specified and directed by Engineer-in-Charge. | 95 | Cum | 6.25 | ₹593.75 |
| 4 | Removing surplus soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point.Complete all as specified and directed. | 55 | Cum | 7.25 | ₹398.75 |
| 5 | M&L for Sand cushioning for under ground cable with locally available sand for protection of cable 8cm before laying cable and 15cm deep over the cable including spreading and consolidations, complete.
Note :- Punned thickness will be measured and paid. | 36 | Cum | 8.25 | ₹297 |
| 6 | Supply and laying un-reinforced precast concrete cable cover class HVP type 2 with peak size 450 mm x 180 mm x 40 mm complete all as specified and directed by Engineer-in-Charge. | 2,500 | Each | 9.25 | ₹23,125 |
| 7Material and labour for maintenance of power transformer /step down transformer 11 KV of different capacity including following :- (a) Oil leakage checked and necessary rectification, (b) All loose connection (power & control) are checked and rectification, (c) IR value of HV to body, LV to body & HV to LV to be checked by megar with submit. Note :- (i) All the work shall be done as per instruction by the Engr-in-charge. (ii) Obtaining a shutdown and a work permit is mandatory before performing any work on distribution/ Power Transformer. (iii) Plug made/mention in registr of IR value. | |||||
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
tenddocu.pdf
Tender Documents • 0.78 MB
BOQ_874163.xls
BOQ • 1.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .