| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.2 LAccepted-AOC 17 KARAMCHARY COLONY UIT ROAD SRI GANGANAGAR RAJASTHAN 335001 | GANGANAGAR | RAJASTHAN | 335001 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹49.6 L+₹6.3 L (14.6%)Rejected-AOC 363 39KA HASSANGANJ BAWLI KUMAR COMPANY 363 39 KA HASAN GANJ BAWLI SAADAT GANJ LUCKNOW SAADATGANJ | L2 | Rejected-AOC OTHER THAN LOWEST | |
| 3 | L3₹51.1 L+₹7.9 L (18.2%)Rejected-AOC HM 324 PHASE IX SAS NAGAR MOHALI PB | L3 | Rejected-AOC OTHER THAN LOWEST |
| Sl No | Description | Qty | Unit | KUMAR AND COMPANY L2 | M/S MATLOOB AHMED L3 | JK ENGINEERS L1 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down Cement plaster or cement lime plaster on brick or stone walls including raking out joints, hacking for key & scrubbing down with water etc including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge. | 480 | SQUARE METRE | 15 ₹7,200 Lowest | 30 ₹14,400 | 15 ₹7,200 Lowest |
| 2.00 | Demolition of cement concrete (reinforced) (reinforcement cut as required to facilitate demolition) as in roofs, floors (other than ground floors) beams, slabs, staircases, landing, chajjas,facia and similar suspended work including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge. | 6 | CUBIC METRE | 500 ₹3,000 | 500 ₹3,000 | 150 ₹900 Lowest |
| 3.00 | Dismantlling Asbestos cement (corrugated,semicorrugated, etc.) sheets in roof coverings in any position complete all as specified and directed by Engineer in Charge. | 1,370 | SQUARE METRE | 15 ₹20,550 Lowest | 50 ₹68,500 | 15 ₹20,550 Lowest |
| 4.00 | Dismantling wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/
blankets, any thickness, including cover fillets complete, all as specified and as directed by Engr-in-charge. | 470 | SQUARE METRE | 15 ₹7,050 | 5 ₹2,350 Lowest | 10 ₹4,700 |
| 5.00 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge. | 230 | SQUARE METRE | 15 ₹3,450 | 30 ₹6,900 | 12 ₹2,760 Lowest |
| 6.00 | Demolition of Cement concrete unreinforced as in Ground Floor and paving n. exc. 15cm thick (above or below G.L.) complete including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge. | 24 | CUBIC METRE | 500 ₹12,000 | 500 ₹12,000 | 200 ₹4,800 Lowest |
| 7.00 | Taking down chowkhats or frames n.exc 1.5 sqm each (without taking off shutter from the frame) and removing from the site including dismantling brick work of hold fasts and making good the dismantled portion in CM 1:3 or PCC 1:2:4 complete all as specified and directed by Engineer-in-Charge. | 35 | EACH | 250 ₹8,750 | 200 ₹7,000 | 100 ₹3,500 Lowest |
| 8.00 | Taking down chowkhats or frames exc 1.5 sqm but n.exc 4 sqm each (without taking off shutter from the frame) and removing from the site including dismantling brick work of hold fasts and making good the dismantled portion in CM 1:3 or PCC 1:2:4complete all as specified and directed by Engineer-in-Charge. | 15 | EACH | 250 ₹3,750 | 300 ₹4,500 | 100 ₹1,500 Lowest |
| 9.00 | Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc, removing rubbish off the premises complete all as specified and directed by Engineer-in-Charge. | 60 | 10 SQUARE METRE | 200 ₹12,000 | 150 ₹9,000 | 50 ₹3,000 Lowest |
| 10.00 | Demolition and breaking up rain water pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar from any situation complete all as specified and directed by Engineer-in-Charge. | 60 | RUNNING METRE | 10 ₹600 Lowest | 20 ₹1,200 | 20 ₹1,200 |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
7 Jul 2025, 6:00 pmClosed
GE CHANDIGARH
GE CHANDIGARH N AREA OLD AIRPORT CHOWK CHANDIGARH 160003
GE/CHD/T-11/2025-26 SPECIAL REPAIRS TO BLDG NO T-286,T-287,T-288,T-53,T-115 TO T-118 AT N AREA UNDER GE CHANDIGARH
2025_MES_711409_1
GE/CHD/T-11/2025-26
Open Tender
Civil Works
Item Rate
180 days
CHANDIGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE CHANDIGARH
₹97,000
Yes
30 Aug 2025
30 May 2025
9 Jul 2025
30 May 2025
7 Jul 2025
25 Jun 2025
31 May 2025 - 10 Jun 2025
Amount
Taking down Cement plaster or cement lime plaster on brick or stone walls including raking out joints, hacking for key & scrubbing down with water etc including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (reinforced) (reinforcement cut as required to facilitate demolition) as in roofs, floors (other than ground floors) beams, slabs, staircases, landing, chajjas,facia and similar suspended work including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge.
Dismantlling Asbestos cement (corrugated,semicorrugated, etc.) sheets in roof coverings in any position complete all as specified and directed by Engineer in Charge.
Dismantling wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete, all as specified and as directed by Engr-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
Demolition of Cement concrete unreinforced as in Ground Floor and paving n. exc. 15cm thick (above or below G.L.) complete including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames n.exc 1.5 sqm each (without taking off shutter from the frame) and removing from the site including dismantling brick work of hold fasts and making good the dismantled portion in CM 1:3 or PCC 1:2:4 complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames exc 1.5 sqm but n.exc 4 sqm each (without taking off shutter from the frame) and removing from the site including dismantling brick work of hold fasts and making good the dismantled portion in CM 1:3 or PCC 1:2:4complete all as specified and directed by Engineer-in-Charge.
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc, removing rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
Demolition and breaking up rain water pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar from any situation complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing and connections of 15mm bore in pipe, including cleaning for re-fixing or removal from site to store complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing and connections of 20mm bore in pipe, including cleaning for re-fixing or removal from site to store complete all as specified and directed by Engineer-in-Charge.
Disconnecting existing tanks of capacity exc. 500 ltr & n. exc. 1000 ltr, setting aside and removing from site complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work or stone/boulder masonary built in cement mortar incl all quions arches, pillar or any other descrption etc including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge.
Supplying & fixing of PVC water storage tank 1000 ltr capacity HDPE triple layered ,white colour cylindrical type fixed and hoisted in position on roof at any height complete with inlet/outlet of 20 mm GI Pipe connection incl locking arrangement, including supplying & fixing of Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe 20 mm dia (Minimum weight 200 mm - 210 gms ) including 20 mm/15 mm tank nipple with inlet and outlet pipe complete Note : (i) Inlet, outlet & wash out pipe will be measured paid for separately. (ii) The quoted rate is inclusive of minimum one union each on inlet and outlet of water tank as per size of pipe shall be provided.
25 mm thick Cement concrete (1:2:4) type B-0,using 12.5 mm graded mechanically crushed stone aggregate as in levelling concrete etc. complete all as specified and directed by Engineer-in-Charge.
75 mm thick, cement concrete type C-2, 1:3:6 using 40 mm graded stone aggregate, finished even & smooth without using extra cement, as in plinth protection, complete all as specified.Plinth protection shall be laid in 1:20 slope and joint filling sealed with bituminous sealing compound grade "A" .
Plain cement concrete (1:4:8) type D-2,using 40 mm graded stone aggregate as in foundations, filling and mass concrete, sub base etc complete all as specified and directed by Engineer-in-Charge.
Reinforced Cement Concrete nominal mix 1:1.5:3 type A-1 using 20mm graded mechanically crushed stone aggregate as in slabs supported on walls, beams and columns in floors,chajjas,drilling ,welding in old steel, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer-in-Charge.
TMT steel bars 10mm dia and over, of grade Fe-500D cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
TMT steel bars 6mm to 8 mm dia and over, of grade Fe-500D cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed by Engineer-in-Charge.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws,hooks etc complete all as specified and as directed by Engr-in-charge.Colour to be decided by GE
Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws,hooks etc complete all as specified and as directed by Engr-in-charge.Colour to be decided by GE
Vitrified ceramic tiles double charged light shade 10 mm thick (Square/rectangular) polished, area of each tiles exceeding 0.36 Sqm but not exceeding 0.72 Sqm, in floor,skirting etc set and jointed with 4 mm spacer and grouting the joint of flooring with epoxy grout mix of organic coated filler of desired shade,hardener ,resin in the ratio of 8:1:2 laid over and including 15mm thick screed bedding layer in CM (1:6) complete all as specified and directed by Engineer-in-Charge.
First quality Non - skid coloured Ceramic tiles 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors etc. set and jointed with 4 mm spacer and grouting the joint of flooring with epoxy grout mix of organic coated filler of desired shade,hardener ,resin in the ratio of 8:1:2 laid over and inculding 15 mm thick screed in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
First quality Non - skid coloured Ceramic tiles 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors etc. set and jointed with 4 mm spacer and grouting the joint of flooring with epoxy grout mix of organic coated filler of desired shade,hardener ,resin in the ratio of 8:1:2 laid over and inculding 15 mm thick screed in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Glazed ceramic coloured tiles 450 x 300 x 7mm thick on vertical surface such as skirting , dado etc. over and including 10 mm thick rendering in CM 1:4 thick set and jointed with 4 mm spacer and grouting the joint of flooring with epoxy grout mix of organic coated filler of desired shade,hardener ,resin in the ratio of 8:1:2 complete all as specified and directed by Engineer-in-Charge.
Machine cut Kota stone slab flooring 20-22 mm thick,SIZE 55 CM x 55 cm laid over & including 20 mm thick screed bed in cement mortar 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (mirror finish) complete all as specified and directed by Engineer-in-Charge.
Machine cut Kota stone slab 20-22 mm thick as in skirting, dado and pillars etc , laid over & including 10 mm thick rendering in cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (mirror finish) complete all as specified and directed by Engineer-in-Charge.
Granite jet black shade, 18-20 mm thick, (table rubbed and polished) in single piece (in one direction) machine cut, machine polished, bedded and jointed with adhesive suitable for granite/stone & pointed with grout of matching shade including necessary cutting over & including 10 mm thick (average thickness) cement mortar (1:3) screed, as in cooking platform, shelves, RCC counters, window cills & similar situations including rubbing,moulding and polishing complete all as specified and directed by Engineer-in-Charge.
Brick work with sub class 'B' bricks, class designation 100, old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
Brick work with sub class 'B' bricks, class designation 100, old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar 1:4 EXCEPT BRICKS complete all as specified and directed by Engineer-in-Charge.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc.,of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & patternover and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed.
Rendering 15 mm thick in cement mortar 1:6, on fair faces of brick or concrete surfaces , trowelled to even and smooth surface without using extra cement, complete all as specified and directed by Engineer-in-Charge.
Rendering 15 mm thick in cement mortar 1:4, on other than fair faces of brick or concrete surfaces mixed with water proofing compound on top layer , trowelled to even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. NOTE: Water proofing compound shall be measured and paid separately.
Supply only liquid water proofing comound ISI Marked complete all as specified and directed.
Preparation of surfaces of walls brooming down, applying one coat of white cement based wall care putty 1 mm thick etc complete all as specified and directed by Engineer-in-Charge.
Preparation of new external surfaces of walls brooming down, applying two coats of cement based paint white or tinted over a coat of primer including properly filling the cracks with putty, etc complete all as specified and directed by Engineer-in-Charge.
Preparation of new plastered surfaces of wall and applying two coats of oil bound distemper on walls over and including a coat of primer and 1 mm wall care puty including preparation of surface complete all as specified and directed.
Complete removal of existing treatment,preparation of surfaces and applying two coats of cement base paint over a coat of primer including properly filling the cracks with putty complete all as specified and directed by Engineer-in-Charge.
Complete removal of existing treatmen,preparation of surfaces of walls brooming down, applying one coat of white cement based wall care putty after applying emery paper or sand paper and applying two coats of oil bound distemper on walls over and including a coat of alkali resistant primer complete all as specified and directed by Engineer-in-Charge.
Factory made Pressed steel frames, confirming to IS, having profile 125 x 60 mm , 1.25 mm thick MS sheet for doors with one or more rebates including necessary fixing lugs, and 100 mm size hinges, lock strike plate, etc., with one shop coat of zinc chromate primer and fixing complete all as specified and directed by Engineer-in-Charge.
Factory made Pressed steel frames, confirming to IS, having profile 105 x 60 mm , 1.25 mm thick MS sheet for doors with one or more rebates including necessary fixing lugs, and 100 mm size hinges, lock strike plate, etc., with one shop coat of zinc chromate primer and fixing complete all as specified and directed by Engineer-in-Charge.
Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles),With Wood free EPS with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification to be fitted in the MS frame welded/scaled to the stiles & rail with suitable PVC sheet beading & jointed together with solvent cement supply & fixing in the frame at site as per specification & drawing.
35 mm thick factory made glazed & Skeleton shutters of 2nd class Hardwood open rebated & prepared to receive glass or gauze etc without sash bar open rebated with edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing glass or guage etc size ofstiles rails etc as specified in sec 8 clause 8.24 (a) of SSR Part-I (2009) complete all as specified and directed by Engineer-in-Charge.
35 mm thick factory made Plain, framed, panelled shutters of 2nd class Hardwood (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkat complete all as specified and directed by Engineer-in-Charge.
Solid PVC door frames of size 50mm x 47 mm made out of 5mm wood grain printed PVC sheet reinforced with MS square tube, and edges will be painted to match with printed sheet, supply & fixing in opening as per specification & drawing complete all as specified and directed by Engineer-in-Charge.
Factory made box type steel windows with pressed steel frame min 1.25 thick complete including mild steel acessories like lugs, door stopper, holdfasts, pintol hinges, handles( minimum One for each shutter), and ISI marked tower bolt 150mm size (minimum 2 for each shutter) etc. with glazing bars and without glazing bars (Double shutter ) dovetailed or welded with one shop coat of zinc chromate primer, complete all as shown on drawing No. TD-276(R), Sheet No 1/4 to 2/4, 3/4, 4R/4 and as specified and directed by Engineer-in-Charge. Note: (i) Fabrication as per TD-276 (R) SH 1/4 to 2/4, 3/4, 4 (R) /4 (ii)Mode of measurement Unit will be for the complete window except Glass/ Gauge but incl fittings, ISI marked iron mongery complete as per TD. (iii) The PCC back filling in chowkhat of window, Grills,Sheet glass and wire gauge will be measured and paid separately against respective items.
Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partition frames (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top,bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle,Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge complete all as specified and directed by Engineer-in-Charge.
Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per drawings and the directions of Engineer-in-Charge
Mild Steel Framed work as in guard bars/grills, gratings, etc.. with ends of bars shouldered/welded and/or riveted, or forged into spikes; framed guard bars/grills conforming to Fe-290 (Gde E-165) complete all as as specified and directed by Engineer-in-Charge.
Aluminium anodised,barrel tower bolts of extruded section with length of bolt 200 mm and dia of bolt not less than 10 mm,ISI marked complete all as specified and directed by Engineer-in-Charge.
Aluminium butt hinges 100 mm long medium weight with stainless steel screws complete ,all as specified and as directed by Engr-in-charge.
300 mm long,Aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified & directed by Engineer in Charge.
150 mm long Aluminium handles, cast type,anodised complete all as specified and directed by Engineer-in-Charge.
100 mm long Aluminium handles, cast type,anodised complete all as specified and directed by Engineer-in-Charge.
Peg stays of aluminium alloy anodised 150 mm complete all as specified and directed by Engineer-in-Charge.
Aluminium body peg set of 6 pegs complete all as specified and directed by Engineer-in-Charge.
25mm dia stainless steel fancy type drapery rod of wall thickness 0.9 mm with fixed brackets,stops and rollers including taking out of old pelmet/bracket, complete all as specified and directed by Engineer-in-Charge.
Stainless steel bracket and stainless steel fancy type fennel complete all as specified and directed by Engineer-in-Charge. Note: The quoted rate includes one pair comprising of two brackets and two fancy type fennels.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with stainless steel wire staples complete all as specified and directed by Engineer-in-Charge.
Sheet glass 4.0 mm thick, ordinary quality and glazing with silicon sealant & spring glazing clips using Silicon for fixing of glass in addition to silicon sealant, in squares not exceeding 0.5 Sq. mtr in each pane, complete all as specified and directed by Engineer-in-Charge.
Sheet glass 5.5 mm thick, tinted and glazing with silicon sealant & spring glazing clips using Silicon for fixing of glass in addition to silicon sealant, in squares not exceeding 0.5 Sq. mtr in each pane, complete all as specified and directed by Engineer-in-Charge.
4 mm thick figured glass pin head type and glazing with silicon sealant in square not exc 0.5 sqm each and using Silicon for fixing of glass in addition to silicon sealant complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in PVC prelaminated Gypsum Ceiling board 9mm thick with and including anodised aluminium snap grid framework for ceiling having grid size 605 x 605 mm comprising of wall angle of size 25 mm x 25 mm x1.3 mm,main runner of size 38 mm x 25 mm x1.3 mm. The grid system shall be suspended at every 1200 mm c/c in both directions by using 3.5 mm dia aqualine wire fixed to purlin or RCC roof with suitable fasteners to withstand the load of grid system with ceiling board complete all as specified and as directed by Engr-in-charge.Colour to be decided by GE
PVC hollow wall panelling 7 to 8mm thick any colour/design approved by engr-in-charge, inclusive of fixing on to wall incl moulding end caps fixed with PVC sleeves and screws as required at site including dismantling of walls and ceiling boards/wall paneling or insulation board any thickness, including cover fillets complete all as specified and directed
Preparation of new or previously untreated wooden surface of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over one coat of pink primer complete all as specified and directed by Engineer-in-Charge.
Preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Preparation of old or previously treated steel and iron surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint, complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in repairs Vitreous China wash down water closet pan (pedestal pattern), white with plastic seat cover (excluding fixing bolts, flushing cistern and flush pipe) and making connections complete all as specified and directed by Engineer-in-Charge.
Vitreous China EWC one piece water closet pan type of size 380 mm x 655mm x700 mm white with and including seat cover,flush cistern 10 ltr capacity,connection pipe,P or S trap (closed pattern incl all necessary accessories like rag bolts,kit/gel gaskets,CP jet with connector pipe ,fixing bolts complete all as specified and directed by Engineer-in-Charge.
10 ltr capacity PVC valveless, syphonic action dual flush type flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, 32 mm dia flush pipe complete all as specified and directed by Engineer-in-Charge.
Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect all as specified and directed by Engineer-in-Charge'.
Supplying and fixing in repairs vitreous china wash hand basin white with pedestal ,flat back of size 550x440mm including galvanised iron brackets , chromium plated waste coupling, waste pipe etc., (incl all waste fittings) complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in repairs 15 mm fancy type chromium plated fancy type bib tap brass long body with flange screwed down high pressure CP cast copper alloy with crutch or butterfly handles screwed down suitable for 15mm bore pipe or union complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in repairs 15 mm fancy type chromium plated fancy type Pillar taps, cast copper alloy, with capstan heads,chromium plated,screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in repairs 15mm bore stop valves/angle valve fancy type cast copper alloy chromium plated screwed down high pressure with crutch or butterfly handle complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in repair waste coupling of PTMT (half or full threaded) suitable for 32 mm discharge pipe (Minimum weight 45gms) complete all as specified and directed by Engineer-in-Charge.
Supply and fixed in repair brass chromium plated, tubular towel rail, 20mm dia, 60cm long between flanges complete all as specified and directed by Engineer-in-Charge.
Chromium plated brass fancy type soap dish holder of approx size 160 x160 x 90 mm, complete all as specified and as directed.
Supply and fixing corner glass shelf assembly comprising of three pieces 5.5 mm thick toughened glass 300x300mm wide bevelled edge/ hatching of edges fixed with stainless steel "D" brackets with railing complete ,all as specified and directed by Engineer-in-charge.
Supplying and fixing in repairs PVC waste pipe 32 mm dia,800 mm long flexible for Sink and WHB complete all as specified and directed by Engineer-in-Charge.
PVC connections 15mm size with PTMT nuts of length 600 mm fixed in repair complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing PTMT Shelf fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) of size 450 mm x 124 mm fixed with stainless steel screws complete all as specified and directed by Engineer in Charge.
Stainless steel grating 100 mm dia with locking system complete all as specified and directed by Engineer-in-Charge.
PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75 mm bore including jointing to waste pipe in cement concrete type B-1 (1:2:4) of size 200 mm x 200 mm x 250mm fixed in repair complete all as specified and directed by Engineer in Charge.
75mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls with and including MS clamps made out of flat iron of size 25 mm x 3 mm including nuts,bolts complete all as specified and directed by Engineer-in-Charge.
110 mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls with and including MS clamps made out of flat iron of size 25 mm x 3 mm including nuts,bolts complete all as specified and directed by Engineer-in-Charge.
PVC(SWR) bends (any radius), for 75 mm bore pipes, with access doors, complete all as specified and directed by Engineer-in-Charge.
PVC(SWR) bends (any radius), for 110mm bore pipes, with access doors, complete all as specified and directed by Engineer-in-Charge.
PVC (SWR) junction single, (Single T) equal or unequal, for 75 mm bore pipes, with access doors, complete all as specified and directed by Engineer-in-Charge.
PVC (SWR) junction single, (Single T) equal or unequa, for 110mm bore pipes, with access doors, complete all as specified and directed by Engineer-in-Charge.
CPVC(SDR-11) of outer dia 25 mm with and including CPVC SDR-11 fittings on walls and ceilings or laying in floors complete all as specified and directed by Engineer-in-Charge.
CPVC(SDR-11) of outer dia 20 mm with and including CPVC SDR-11 fittings on walls and ceilings or laying in floors complete all as specified and directed by Engineer-in-Charge.
CPVC SDR- 11 brass elbow fittings, ISI marked for CPVC pipe outer diameter 20 mm bore complete all as specified and directed by Engineer-in-Charge.
CPVC SDR- 11 brass elbow fittings, ISI marked for CPVC pipe outer diameter 25 mm bore complete all as specified and directed by Engineer-in-Charge.
CPVC SDR- 11 brass TEE fittings, ISI marked for CPVC pipe outer diameter 20 mm bore complete all as specified and directed by Engineer-in-Charge.
CPVC SDR- 11 brass TEE fittings, ISI marked for CPVC pipe outer diameter 25 mm bore complete all as specified and directed by Engineer-in-Charge.
CPVC SDR- 11 brass UNION fittings, ISI marked for CPVC pipe outer diameter 25 mm bore complete all as specified and directed by Engineer-in-Charge.
CPVC SDR- 11 brass UNION fittings, ISI marked for CPVC pipe outer diameter 20 mm bore complete all as specified and directed by Engineer-in-Charge.
CPVC SDR- 11 Tank Adaptor nipple fittings, ISI marked for CPVC pipe outer diameter 20 mm bore complete all as specified and directed by Engineer-in-Charge.
CPVC SDR- 11 Tank Adaptor nipple fittings, ISI marked for CPVC pipe outer diameter 25 mm bore complete all as specified and directed by Engineer-in-Charge.
CPVC SDR- 11 Ball valve fittings, ISI marked for CPVC pipe outer diameter 20 mm bore complete all as specified and directed by Engineer-in-Charge.
CPVC SDR- 11 Ball valve fittings ISI marked for CPVC pipe outer diameter 25 mm bore complete all as specified and directed by Engineer-in-Charge.B156:B157
CPVC SDR- 11 Female Brass Threaded Adaptor (FTA/ FBTA) fittings, ISI marked for CPVC pipe outer diameter 20 mm bore complete all as specified and directed by Engineer-in-Charge.
CPVC SDR- 11 Female Brass Threaded Adaptor (FTA/ FBTA) fittings, ISI marked for CPVC pipe outer diameter 25 mm bore complete all as specified and directed by Engineer-in-Charge.
INTERNAL ELECTRIC SUPPLY WORKS
Taking down Copper/Aluminium point wiring (light, fan, socket or power) complete, any type / size complete with removing all connection and accessories, fittings and fixtures such as switches , sockets, ceiling rose,pendent holder,fan regulator any type , all type of tube light fitting , batten , steel or PVC conduit , casing caping etc compele and making good the disturbed surface of wall , floor etc. complete all as specified and directed by Engineer-in-Charge. Note :-- Rates for cutting/chases in walls and making good disturbed area deemed to be included in the quoted rate
Taking down existing unserviceable sub main wiring with 2 Runs/4 Runs of 2.5/4/6 Sqmm aluminum/copper cable all as directed by Engr-in-charge.
Point wiring using approved colour coding as per IS ,with stranded copper conductor 1.5 sqmm (nominal area ) single core , flame retardant low smoke and low halogen FRLSH PVC insulated unsheathed , 1100 V grade conforming to IS 694 ,marked TEC and FIA approved in and including PVC conduit medium grade ISI marked 20mm dia with all fittings and accessories, concealed type/ surface type (surface type only on ceiling), PVC junction boxes, modular metal sunken/flush boxes of any modules from 2 to 18 Modules with Inner and outer modular cover plates, including FRLSH flame retardant low smoke and low halogen rigid PVC insulated unsheathed stranded copper conductor 1.5 Sqmm (nominal area )single core cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified and directed by Engr-in-charge. Note :- 1. Cutting/chasing of wall etc. deemed to be included in the quoted rate of this item. 2. Modular metal flush/sunken Box along with modular switch/socket cover plate & sheet are inclusive in the item rate quoted. 3. Only switch socket and fan regulators to be measured and paid separately
(a) One light point controlled by one switch or one (Ceiling/ Wall/ Exhaust) fan point ,bell controlled by one switch and regulator
(b) One 3 pin 5 Amps socket outlet on independent board
(c ) One 3 pin 5 Amps socket outlet on same board with other switches
(d) One light point controlled by two, two way switches.
Point wiring using approved colour coding as per IS ,with stranded copper conductor 2.5 sqmm (nominal area ) single core , FRLSH flame retardant low smoke and low halogen PVC insulated unsheathed , 1100 V grade conforming to IS 694 ,marked TEC and FIA approved in and including PVC conduit medium grade ISI marked 20mm dia with all fittings and accessories, concealed type/ surface type (surface type only on ceiling), PVC junction boxes, modular metal sunkun/ flush boxs of any modules from 2 to 18 Modules with Inner and outer modular cover plates, including FRLSH flame retardant low smoke and low halogen rigid PVC insulated unsheathed stranded copper conductor 2.5 Sqmm (nominal area )single core cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified and directed by Engr-in-charge. Note :- 1. Cutting/chasing of wall etc. deemed to be included in the quoted rate of this item. 2. Modular metal flush/sunken Box along with modular switch/socket cover plate & sheet are inclusive in the item rate quoted. 3. Only switch, socket and fan regulators to be measured and paid separately
Point wiring using approved colour coding as per IS ,with stranded copper conductor 4 sqmm (nominal area ) single core , FRLSH flame retardant low smoke and low halogen PVC insulated unsheathed , 1100 V grade conforming to IS 694 ,marked TEC and FIA approved in and including PVC conduit medium grade ISI marked 20mm dia with all fittings and accessories, concealed type/ surface type (surface type only on ceiling), PVC junction boxes, modular metal sunkun/ flush boxs of any modules from 2 to 18 Modules with Inner and outer modular cover plates, including FRLSH flame retardant low smoke and low halogen rigid PVC insulated unsheathed stranded copper conductor 4 Sqmm (nominal area )single core cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified and directed by Engr-in-charge. Note :- 1. Cutting/chasing of wall etc. deemed to be included in the quoted rate of this item. 2. Modular metal flush/sunken Box along with modular switch/socket cover plate & sheet are inclusive in the item rate quoted. 3. Only switch, socket and fan regulators to be measured and paid separately
Modular snap Switch one way 6 Amps one module complete all as specified and directed.
Modular snap Switch two way 6 Amps one module complete all as specified and directed.
Modular snap Switch one way 16 Amps one module complete all as specified and directed.
Modular Socket 6 Amps 5 Pin 2 Module complete all as specified and directed.
Modular Socket 6/16Amps 5 Pin 2 Module complete all as specified and directed.
Modular blanking plate suitable for 1 Module complete all as specified and directed
Modular Bell Push 6 Amps one module complete all as specified and directed.
Modular fan Regulator step electronic type 2 module complete all as specified and directed.
Ceiling rose surface backlite 65 x 20mm size three terminalcomplete all as specified and directed.
Electric bell AC, ding-dong type, 230 Volt, single pole complete all as specified and directed.
Lamp holder, PVC/ Polycarbonate type with back plate with and including one no of LED bulb 15 watt Base-22 retrofit type complete all as specified & directed.
LED lights fitting 1x 20 Watt, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose including 20 watt LED tube rod complete all as specified and directed.
Surface mounted wall mirror LED light 2 feet Compact & sturdy 10 watt LED decorative fixture with anti glare polycarbonate diffuser, multi purpose lighting solution & applications .all accessories & fixtures, internally prewired and connecting by providing copper flexible wire 23/.0076 mm twin core upto fitting, complete all as specified and directed.
10W Bulk head LED luminaries Die cast aluminium alloy body ,heat resistent prismatic glass cover ,with specially designed gasket incl all accessories & fixtures, internally prewired and connecting by provding copper flexible wire 23/.0076 mm twin core upto fitting, complete in all respects complete all as specified and directed by Engineer-in-Charge.
36 watt recessed mounting downlight 2 x2 ft decorative type incl all accessories & fixtures, internally prewired and connecting by provding copper flexible wire 23/.0076 mm twin core upto fitting, complete in all respects complete all as specified and directed by Engineer-in-Charge.
Security Light LED 45 Watt made up of pressure dia cast Alumunium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including sevice bracket of GI pipe 32mm bore medium grade of length 0.9 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting fitting to GI pipe as required as site and making electrical connection, complete all as specified and directed.
Sub main wiring using approved colour coding as per IS with two runs of 10 sqmm PVC insulated, unsheathed cable FRLSH, flame retardant low smoke and low halogen 1100 volts grade , ISI marked with multistranded copper conductor with one run of 10 sqmm (green colour) PVC insulated, unsheathed cable FRLSH, flame retardant low smoke and low halogen 1100 volts grade , ISI marked with multistranded copper conductor as earth wire connected to common earth dolly with thimbles, drawing into & including PVC Concealed conduit ISI marked with all accessories on walls and making good of disturbed surfaces including all conduit fittings, clamps, gutties etc all as specified and directed. Note: (i) Three runs ( main ) of 10.00 sqmm cable together with conduit shall be considered as 1 running meter for payment purpose.
Vertical Distribution Board iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/S 4 way, complete with appropriate size copper bus bar and neutral link complete with one MCCB 3 pole 415 Volts 100 Amps rating with rupturing cap 16 KA and one MCCB TPN 415 Volts 63 Amps rating with rupturing cap 10 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge.
Distribution Board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, 8 way SPN, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc flushed on the existing wall , to match with existing surface and making all necessary connections complete all as specified and directed.
SPN AFDD 16A/32A/40A offering protections for overload, short circuit, Residual current characterisitics TYPE A, Over Voltage protection above 270 AC plus minus 5% & series parallel arc fault. AFDD must be dual test button for AFDD and Earth leakage functions along with single diagnostic LED with blinking patterns for continuous ON, Series Arc, Parallel arc and overvoltage protection complete all as specified and directed.
Portable current residual device (PRCD) 16 A 30mA Euro II all as specified and as directed by Engr in charge.
MCB SPN 40-63 Amp,240 volts,50Hz, 10KA, 'C' series ISI marked as incoming and outgoing controlling circuit all as specified and directed.
MCB SP 6- 32 Amps, 220 volts , 50 Hzs, 10 KA , "C" series, ISI marked all as specified and directed.
Exhaust fan 300 mm sweep metal body, heavy duty, Single phase AC 230/240V, with energy efficient motor, pre lubricated double ball bearing, speed 950 rpm complete with louvers for wall mounting including grouting,making hole in the wall (Square/Round) as feasible grouting and holding down bolts, nuts, washers and provision of flexible copper conductor cable 3 core from ceiling rose to exhaust fan incl cutting of hole of required size for fixing of the exhaust fan complete all as specified and directed
Dismantling of ceiling fans,scrapping of old paint,Painting of ceiling fans complete, in situ with two coats of synthetic enamel paint over a coat of anti- corrosive zinc red oxide by spraying including filling cavities with filler, one coat after cleaning all dust etc,replacement of rubber bush,nuts,bolts,washers,split pin,down rod,copper flexible cable all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.50 meter wide and not exceeding 1.5 meter in depth; for foundation or for shafts, wells, cesspits, manholes, pierholes, etc. not exceeding 10 sq. m on plan and getting out complete all as specified.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick each,excavated soil in soft/loose soil, complete, all as specified and directed by Engineer-in-Charge.
Removing of surplus soil/ excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5m above the starting point complete, all as specified and directed by Engineer-in-Charge.
Clean dry sand laid in trenches/ducts for bedding and cushioning to cable, 8cm in depth before laying the cable and 15 cm in depth after laying the cable including spreading, levelling and consolidation complete all as specified and directed. Note : Consolidated/punned sand shall be measured for payment purpose.
Supply and laying burnt bricks sub class "B" old size for cable protection laid flat length perpenducualr to the axis of cable complete all as specified and direted by Engineer-in-Charge.
Earthing complete with and including galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected with and including galvanised iron or steel earth wire, 4mm dia (No. 8 SWG) by means bolts, nuts, check nuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SSR Part-I (2009) complete all as shown on drawings and as specified and directed by Engineer-in-Charge. Note : The unit rate includes for protecton pipe 15mm and GI earth strip 4mm from top of earth plate upto 7.50 metre above ground level.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 95 sq. mm, 3.5 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 25 sq. mm, 2 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
Note: For the purpose of arriving at net contract sum, the amount of credit schedule i.e Sch 'A' section II (i.e Rs 114173.00 shall be deducted from the total amount arrived.
Total of Schedule 'A' Rs.
KUMAR AND COMPANY (BID ID -3341866)
M/S MATLOOB AHMED (BID ID -3349920)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .