| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-AOC 15 CP COLONY MORAR GWALIOR MP 474 006 | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | ₹17.7 L Quoted ₹18.9 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹19.0 LRejected-Finance HOSUE NO 202 NEW RAM VIHAR COLONY PINTO PARK MORAR GWALIOR 474005 MP | GWALIOR | MADHYA PRADESH | 474005 | ₹19.0 L | L2 | Rejected-Finance BEING OTHER THAN L1 |
| 3 | L3₹19.2 LRejected-Finance | ₹19.2 L | L3 | Rejected-Finance BEING OTHER THAN L1 |
| 4 | L4₹20.7 LRejected-Finance ADARSH COLONY GOLE KA MANDIR GWALIOR MP | GWALIOR | MADHYA PRADESH | 474001 | ₹20.7 L | L4 | Rejected-Finance BEING OTHER THAN L1 |
| 5 | L5₹26.2 LRejected-Finance | ₹26.2 L | L5 | Rejected-Finance BEING OTHER THAN L1 |
| Sl No | Description | Qty | Unit | M/S Rakesh Verma L3 | m/s varsha traders L5 | M/S KAPIL CONSTRUCTION CO L9 | Akarsha Enterprises L8 | keerti enterprises L6 | KP ELECTRICAL AND AUTOMATION L2 | M/S uneversal agency L4 | M/s Anupam Construction Co. L1 | SHRI HARI CONSTRUCTION L7 | M/s Yashika Enterprises L10 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M & L for checking ,repairing & fixing Street lights/flood lights/tower lights/highmast lights/parts & other connected work as directed in tech area daily and repairing of lights found unserviceable during checking or as per directed by JE/Engr-in-Charge/men on complaint cell including rectification of fault of cable/lights etc by deploying skilled Electrician, helper with all tools & plants, ladder, gaskets safety arrangements and including providing minor materials like insulation tap and connected material by contractor to make light almost 100% serviceable complete all as specified and directed.
NOTES :-
(i) Replacement of spares and connected items shall be measured and paid as supply only under the relevant item of the schedule
(ii) Replacement of unserviceable spare parts/ accessories of the light fittings and replacement of brackets required for defective light fittings shall be measured and paid separately at supply only rates under relevant items of this schedule.
(iii) Replacement of screws, nuts, bolts and consumables shall be deemed to be included in the rate quoted and no extra payment shall be allowed.
(iv) The contractor or his representative will attend to unserviceable street light/faulty complaints and ensure the fault is rectified as soon as possible. A copy of the report will be submitted to the Engineer-in-Charge.
(v) All the T&P shall be provided by the contractor
(vi) Contractor should provide a labourer/supervisor every day at a site or the perimeter of the Tech area to check the serviceability of all the street lights and maintain a register duly signed by JE/Engr-in-Charge. The fault should be rectified within 24 hrs by the contractor failing which a penalty @ 500.00 per complaint will be recovered from work done statement till rectification | 3,000 | Each Job | 40 ₹1.2 L | 70 ₹2.1 L | 65 ₹1.9 L | 50 ₹1.5 L | 50 ₹1.5 L | 40 ₹1.2 L | 70 ₹2.1 L | 30 ₹90,000 | 27 ₹81,000 | 50 ₹1.5 L |
| 2.00Supply only in repair Driver for LED lights of different capacities complete all as specified and as directed.- | |||||||||||||
| 2.01 | Driver for 70/72watts LED | 50 | Each | 200 ₹10,000 | 200 ₹10,000 | 398 ₹19,900 | 350 ₹17,500 | 440 ₹22,000 | 200 ₹10,000 | 350 ₹17,500 | 250 ₹12,500 | 400 ₹20,000 | 250 ₹12,500 |
| 2.02 | Driver for 90 watts LED | 50 | Each | 200 ₹10,000 | 200 ₹10,000 | 428 ₹21,400 | 350 ₹17,500 | 540 ₹27,000 | 250 ₹12,500 | 350 ₹17,500 | 300 ₹15,000 | 500 ₹25,000 | 250 ₹12,500 |
| 2.03 | Driver for 100-120 watts LED | 20 | Each | 250 ₹5,000 | 200 ₹4,000 | 550 ₹11,000 | 400 ₹8,000 | 580 ₹11,600 | 300 ₹6,000 | 500 ₹10,000 | 350 ₹7,000 | 600 ₹12,000 | 300 ₹6,000 |
| 2.04 | Driver for 150 to 200 watts LED flood light | 10 | Each | 300 ₹3,000 | 200 ₹2,000 | 640 ₹6,400 | 450 ₹4,500 | 760 ₹7,600 | 400 ₹4,000 | 600 ₹6,000 | 375 ₹3,750 | 700 ₹7,000 | 300 ₹3,000 |
| 3.00 | Supply only and testing new generation energy saving & environmental friendly long life versatile pressure die cast aluminium housing LED Street light luminaires with IP-66 70 Watt LED as light source suitable for pole dia 54 mm (max) inlcuding making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5 Sqmm complete all as specified and directed by Engr-in-charge.
Note:- Fixing cost will be paid vide Item No 01 above | 40 | Each | 1,350 ₹54,000 | 3,000 ₹1.2 L | 2,390 ₹95,600 | 1,850 ₹74,000 | 2,700 ₹1.1 L | 1,600 ₹64,000 | 1,500 ₹60,000 | 2,250 ₹90,000 | 2,900 ₹1.2 L | 2,300 ₹92,000 |
| 4.00 | Supply only testing new generation energy saving & environmental friendly long life versatile pressure die cast aluminium IP-66 roadway luminaire 90 Watt LED with high power LED as light source suitable for pole dia 63 mm (max) inlcuding making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5 Sqmm complete all as specified and directed by Engr-in-charge.
Note:- Fixing cost will be paid vide Item No 01 above | 25 | Each | 2,300 ₹57,500 | 3,800 ₹95,000 | 2,930 ₹73,250 | 2,450 ₹61,250 | 2,800 ₹70,000 | 2,100 ₹52,500 | 2,000 ₹50,000 | 2,500 ₹62,500 | 3,200 ₹80,000 | 3,000 ₹75,000 |
| 5.00 | Supply only connecting and testing new generation energy saving & environmental friendly long life versatile pressure die cast aluminium IP-66 roadway luminaire 120 Watt LED with high power LEDas light source suitable for pole dia 63 mm (max) inlcuding making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5 Sqmm complete all as specified and directed by Engr-in-charge.
Note:- Fixing cost will be paid vide Item No 01 above | 19 | Each | 1,500 ₹28,500 | 4,500 ₹85,500 | 3,930 ₹74,670 | 3,250 ₹61,750 | 4,000 ₹76,000 | 2,300 ₹43,700 | 2,200 ₹41,800 | 3,250 ₹61,750 | 3,900 ₹74,100 | 4,000 ₹76,000 |
| 6.00 | Supply only in repair energy saving, environmental friendly, long life, exclusive innovative die cast aluminium IP-66 flood light 120 watt capacity with high power LEDs
as light source including making connection with three core PVC insulated and PVC sheathed copper conductor cable complete all as specified and directed by Engr-in-charge.
Note:- Fixing cost will be paid vide Item No 01 above | 10 | Each | 1,500 ₹15,000 | 2,500 ₹25,000 | 4,260 ₹42,600 | 3,250 ₹32,500 | 4,400 ₹44,000 | 2,600 ₹26,000 | 2,600 ₹26,000 | 3,000 ₹30,000 | 3,300 ₹33,000 | 3,500 ₹35,000 |
Updated dates
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
12 Feb 2026, 6:00 pmClosed
GE(AF) TA GWALIOR
GE (AF) TA GWALIOR-474020
REPAIR REPLACEMENT OF STREET LIGHTS SECURITY LIGHTS WATCH TOWER LIGHTS AND CONNECTED WORKS INSIDE TECH AREA OF AFS GWALIOR
2026_MES_748675_1
8900/1638/GWL/E8
Open Tender
Electrical and Maintenance Works
180 days
GWALIOR
Please ref tender documents
7 documents required · 7 mandatory
₹500
GE(AF) TA GWALIOR
₹70,000
Yes
28 Feb 2026
15 Jan 2026
19 Feb 2026
15 Jan 2026
12 Feb 2026
29 Jan 2026
M & L for checking ,repairing & fixing Street lights/flood lights/tower lights/highmast lights/parts & other connected work as directed in tech area daily and repairing of lights found unserviceable during checking or as per directed by JE/Engr-in-Charge/men on complaint cell including rectification of fault of cable/lights etc by deploying skilled Electrician, helper with all tools & plants, ladder, gaskets safety arrangements and including providing minor materials like insulation tap and connected material by contractor to make light almost 100% serviceable complete all as specified and directed. NOTES :- (i) Replacement of spares and connected items shall be measured and paid as supply only under the relevant item of the schedule (ii) Replacement of unserviceable spare parts/ accessories of the light fittings and replacement of brackets required for defective light fittings shall be measured and paid separately at supply only rates under relevant items of this schedule. (iii) Replacement of screws, nuts, bolts and consumables shall be deemed to be included in the rate quoted and no extra payment shall be allowed. (iv) The contractor or his representative will attend to unserviceable street light/faulty complaints and ensure the fault is rectified as soon as possible. A copy of the report will be submitted to the Engineer-in-Charge. (v) All the T&P shall be provided by the contractor (vi) Contractor should provide a labourer/supervisor every day at a site or the perimeter of the Tech area to check the serviceability of all the street lights and maintain a register duly signed by JE/Engr-in-Charge. The fault should be rectified within 24 hrs by the contractor failing which a penalty @ 500.00 per complaint will be recovered from work done statement till rectification
Driver for 70/72watts LED
Driver for 90 watts LED
Driver for 100-120 watts LED
Driver for 150 to 200 watts LED flood light
Supply only and testing new generation energy saving & environmental friendly long life versatile pressure die cast aluminium housing LED Street light luminaires with IP-66 70 Watt LED as light source suitable for pole dia 54 mm (max) inlcuding making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5 Sqmm complete all as specified and directed by Engr-in-charge. Note:- Fixing cost will be paid vide Item No 01 above
Supply only testing new generation energy saving & environmental friendly long life versatile pressure die cast aluminium IP-66 roadway luminaire 90 Watt LED with high power LED as light source suitable for pole dia 63 mm (max) inlcuding making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5 Sqmm complete all as specified and directed by Engr-in-charge. Note:- Fixing cost will be paid vide Item No 01 above
Supply only connecting and testing new generation energy saving & environmental friendly long life versatile pressure die cast aluminium IP-66 roadway luminaire 120 Watt LED with high power LEDas light source suitable for pole dia 63 mm (max) inlcuding making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5 Sqmm complete all as specified and directed by Engr-in-charge. Note:- Fixing cost will be paid vide Item No 01 above
Supply only in repair energy saving, environmental friendly, long life, exclusive innovative die cast aluminium IP-66 flood light 120 watt capacity with high power LEDs as light source including making connection with three core PVC insulated and PVC sheathed copper conductor cable complete all as specified and directed by Engr-in-charge. Note:- Fixing cost will be paid vide Item No 01 above
Supply only in repair energy saving, environmental friendly, long life, exclusive innovative die cast aluminium IP-66 flood light 150 watt capacity with high power LEDs as light source including making connection with three core PVC insulated and PVC sheathed copper conductor cable complete all as specified and directed. Note:- Fixing cost will be paid vide Item No 01 above
Supply only in repair integral LED flood light luminaries, 60 watts installed at pole or any location ranging height from 3m to 16 m height , with scondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66 with mounting GI pipe light grade bracket 40mm dia, 1.5m long bent to shape as required and all accessories and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable , including all accessories and fixing the light fitting to walls/ ceiling etc complete all as specified and directed.Note:- Fixing cost will be paid vide Item No 01 above
Supply and fixing in repair PVC insulated and PVC sheathed three core Aluminium conductor of size 2.5 Sqmm for connecting from bus bar box to street light fittings/ OH line to street light fitting complete all as specified and directed.
(a) 16 Sqmm, 4 core
(b) 25 Sqmm, 4 core
Returning, filling in, including spreading, levelling watering and well ramming in layers n.exc 25cm in soft/loose soil etc complete as specified and directed.
Removing of surplus excavated soil not exceeding 50 M distance and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M & L for power cable route marker pre-cast RCC of size 1000mm x 300mm x 50 mm with top curved portion, 8 mm dia round bar reinforcement, emboshing of letter (MES-LT CABLE) both faces of pre-cast during casting of RCC pre-cast, applying two coats of external emulsion paint with primer approved colour and painting of emboshed surface with black colour including fixing of route marker with proper PCC (1:3:6) foundatiuon complete all as specified and as directed.
S&F in repair factory fabricated Busbar Chamber outdoor type made out of 3.15 mm thick CRCA sheet with powder coating of size not less than 1.00 x 0.45 x 0.90 for set of 04 copper busbar 400 Amps rating , supported with suitable size heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral, The Chamber shall be fixed 60 cm above the normal ground level complete with PCC foundation (1:2:4 ) type B2 and fixing arrangement with angle iron 50 x 50 x 6 mm complete all as specified and directed by Engr in charge.
Supply and lay in repair double-walled corrugated (DWC) HDPE duct pipe of 50 mm bore conforming to IS, approved colour, complete with fittings for cable protection.
M&L for Horizontal directional drilling (HDD) Boring of holes under road, pavement, hard standing, Runway/ PTT by trenchless technology using ultrasonic technique and necessary machine including privison of HDPE pipe of sie not less than 100 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP – 31), 09 mtr long, complete with cast iron base plate, pole cap/finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole and 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint and numbering of the poles shall be done with synthetic enameled painted letter of shape & size complete all as specified and directed including taking down the old unserviceable poles. Note: Necessary excavation, PCC work shall be measured and paid seperately.
M&L for preparation of old painted surfaces of LT steel tubular pole/strut, of any description and in any position 9.00/8.50 Mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, GI pipe bracket of street/security light, anti climbing devices etc and providing three Nos radium band strips complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) for foundation of poles struts & stay assembly etc complete all as specified and as directed.
M&L for PCC (1:3:6) type C1 in coping of poles etc (using 20mm graded coarse aggregate) including fair finishing the exposed surface even and smooth without using extra cement and necessary form work for coping of poles all as specified and directed for the following
Supply only in repair PVC insulated and PVC sheathed twin core Aluminium conductor of size 4.0 Sqmm for connecting from bus bar box to street light fittings/ OH line to street light fitting, complete all as specified and directed. Note : Fixing shall be measured in item no 01.
Supply and fix three Phase Street Lights Dual Automation System Outdoor application to switch ‘ON’ & ‘OFF’ street lights automatically ‘ON’ at sunset i.e. at 40 Lux ± 5 Lux & switch ‘OFF’ on day break at 80 Lux ± 5 Lux with additional features of Pre-programming the switching with LCD Display for the entire year & By-pass mode for manual operation facility. For energy conservation lights on II nd & III rd Phase to switch off automatically one by one on the desired interval. Capacity 25 kVA including necessary copper cable wiring complete all as specified and as directedincluding taking down the old unserviceable timer switch.
Material and labor in repair for maintenance and water-free Conductive Concrete earthing system earthing complete with 100 mm dia of earth enchasing with cement including 17.2 mm solid copper rod electrode with 65 mmx10mm copper bonded flat on top along with providing required holes as shown indrawing to connect the earthing strip, buried directly in ground vertically to a depth not less than 3.14 meter below normal ground level and in160 mm dia bore hole by drilling through any type of soil using mechanical hydraulic boring/drilling machine/Manually after inserting of main earth electrode in the boring hole, rest space to be filled by the excavated soil. The copper bonded electrode is to be connected with 25 mmx3mm copper strip using a copper/brass nut bolt of size 8 mm with copper washer near the top end of the earth electrode is to be connected to Copper strip 25mmx3mm as main earthing lead using copper /brass bolt, nuts, washers, check nuts and strip firmly, earth lead to be connected to earth test point. PCC 1:3:6 type C-1 using 20mm graded stone aggregate for inspection chamber (earth pit ) of size 300mmx300mm internal with 100 mm thick at side i.e. total 500mmx500 mm outer side & 300 mm depth with precast RCC 1:2:4 type B-1 using 20mm graded stone aggregate, 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia round bar handle etcincluding necessary earth work complete all as specified and directed. Note: (i) The cost of earth lead up to and including 7.5 metres only from the top of the earth electrode is deemed to be included under this item, and additional earth lead, if any required, shall be measured and paid for separately under the appropriate item of Sch A.
M&L in repair for earthing complete with copper Earth Plate 600mm X 600mm X 3.15mm buried directly in ground vertically to a depth not less than 3.10 meter below normal ground level (with top edge of earth plate not less than 2.10 mtr below ground level), connecting to copper strip 32mm x 6mm main earth lead by means of tinned copper / brass bolts , nuts, check nuts and washers besides brazing at all joints all as directed and connected to earth test point all as specified and testing on completion with and including necessary excavation and earth work in any type of soil, earth electrode, earthing lead from electrode to test point, made of phosphorous brongze/gun metal of size 75mmx75xmmx25mm dril and screwed including 03 Nos 8mm dia 25mm long hexagonal head screwed, adequate quantity of charcoal dust & common salt in alternate layers of 100mm thick all around the plate, under and above the plate and returning, filling of earth spread levelled, watered and compected to required level, PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast 40mm thick RCC cover of (1:2:4) type B-1 (using 20mm graded stone aggregate), rainforced with 8mm dia TMT bars 3 Nos both way with 12mm dia MS round bar handle, GI medium watering pipe 25mm dia with funnel and wire mesh and 40 mm bore GI light grade earth lead protection pipe complete all as specified and directed . NOTE : (i) The cost of earth lead and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are deemed to be included under this item and additional earth lead , if any, required at site shall be measured and paid for separately under appropriate item of Schedule `A’. (ii) Any joint in earth lead from earth electrode to test point shall not be allowed/permitted.
S&F in repair epoxy insulator on wall/RCC pillar with fasteners at any location, including hangar roof, complete all as specified and directed.
S&F in repair GI funnel with wire mesh for watering the earth pit made to shape and size with using PGI sheet minimum 1.0mm thick and fixed in position complete all as specified and directed.
S&F HDPE DWC flexible pipe of Size 40mm external & 33 mm internal dia (ISI marked) including required clamps/couplers to be fix at 1.5 mtr interval on wall to fix the pipe properly and smooth suitable for insulation & protection of GI /copper /aluminium strip of any size complete all as specified and directed.
S&F HDPE DWC flexible pipe of Size 50mm external & 38 mm internal dia (ISI marked) including required clamps/couplers to be fix at 1.5 mtr interval on wall to fix the pipe properly and smooth suitable for insulation & protection of GI /copper /aluminium strip of any size complete all as specified and directed. including taking down the old unserviceable pipe.
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth in soft / loose soil and getting out for removing / laying of pipe lines complete all as specified and directed
M&L for marker fabricated with 14 gauge MS sheet of size 300mmx180mm rectangular with 20 mm square hollow bar 60 cm long duly painted of colour as directed for writing ER value, date of testing and due date for testing, Earth pit No etc complete all as specified and directed including taking down the old unserviceable marker. Note : Required PCC work with sufficient digging to support & fix the marker is included in this item .
M&L for painting on earth pit & cover with two coats of approved color cement-based paint complete all as specified and directed.
Labour only for rep/maint of of existing tilted/embeded earth pit by digging not exceeding 3 feet deep around earth pit , filling by nearby soil & re-adjusting the earth pit in proper manner ,all as directed .
Disconnecting & taking up or down existing unserviceable / deshaped, aluminum / GI earth strips or taking down conductors of any size and in any position at any location in any height of the building and hangar stacking properly the serviceable strips for re-use in the work including making good the distrurbed surfaces to match with the existing surfaces complete all as specified and directed.
Supplying, fixing & connecting aluminium earth strip 25 mm x 3mm as in roof conductors / down conductor fixed on walls / roofs with saddels/epoxy insulator including screws required at site including taking down old strip complete all as specified and directed.
Supply and fixing earth continuity conductor or main earthing lead 32x6mm GI strip/earth lead, laid in pipe/fixed on walls or any other position including jointing by welding washers at every joint including taking down old strip complete all as specified and directed.
Supply and fixing earth continuity conductor or main earthing lead 32mm x 6mm, copper strip/earth lead, laid in pipe/fixed on walls or any other position including jointing by welding or brazing at every joint including taking down old strip complete all as specified and directed.
Supply and fixing earth continuity conductor or main earthing lead 20mm x 3mm, copper strip/earth lead, laid in pipe/fixed on walls or any other position including jointing by welding brazing at every joint including taking down old strip complete all as specified and directed.
Supply and fixing earth continuity conductor or main earthing lead 25mm x 3mm, copper strip/earth lead, laid in pipe/fixed on walls or any other position including jointing by welding or brazing at every joint including taking down old strip complete all as specified and directed.
Supply and fixing earth continuity conductor or main earthing lead 25mm x 3mm, Aluminium strip fixed on wall on batten or racess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other position including jointed by Aluminium nuts, bolts and washers complete all as specified and directed.
Supply & fixing in repair light grade, 40mm dia GI tubing with all fittings fixed on walls/ poles/ in trenches as in earth lead protection pipe complete all as specified and directed .
Supply & Fixing in repair GI water tubing, light grade, 40mm bore, 1.2 mtr long duly threaded on one side for fixing socket as in Air termination stand / post at roof top of hangers/bldgs complete all as specified and directed. Note : (i) GI socket & PCC/ brick masonry block for fixing of GI pipe post shall be measured and paid for separately under appropriate item of Schedule `A' (ii) GI pipe 1.2 mtr will be in a single length & no joint will be allowed.
All as per item here-in-before but 40 mm bore, 0.6 metre long
Material & labour for GI water tubing, light grade, 50mm bore, 1.2 mtr long, duly threaded on one side for fixing socket as in Air termination stand/post at the roof top of hangers/bldgs, including taking down the unserviceable pipe complete all as specified and directed. Note : (i) GI socket & PCC/ brick masonry block for fixing of GI pipe post shall be measured and paid for separately under appropriate item of Sch 'A’. (ii) GI pipe 1.2 mtr will be in a single length & no joint will be allowed.
Supply & fixing GI water tubing, light grade, 50mm bore, 0.6 mtr long duly threaded on one side for fixing socket as in Air termination stand / post at roof top of hangers/bldgs including taking down the old unserviceable pipe compete all as specified and directed. Note : (i) GI socket & PCC/ brick masonry block for fixing of GI pipe post shall be measured and paid for separately under appropriate item of Sch `A'. (ii) GI pipe 0.6 mtr will be in a single length & no joint will be allowed.
M & L in repair for providing test point terminal block for earthing complete all as specified and directed
Supply and Fixing GI socket 40mm bore , on vertical pipe post / stand including taking down the old unserviceable socket complete all as specified and directed.
Supply & fixing GI reducer (50mm x 40mm bore ), on vertical post / stand including taking down the unserviceable reducer complete all as specified & directed.
Supply & fixing aluminium gutka 40mm dia having internal thread of 12mm dia and external thread of 40mm dia and fixed on GI socket including taking down the unserviceable gutka complete all as specified and directed.
Supply and fix aluminium Air termination rod single pointed at top and properly threaded at bottom end, 12mm dia and 1200 mm long including taking down the unservicable Air termination rod complete all as specified and directed.
Supply and fix aluminium Air termination rod single pointed at top and properly threaded at bottom end, 12mm dia and 300 mm long, including taking down the unserviceable Air termination rod, complete all as specified and directed.
M & L for PCC 1:2:4 for block, type B-I using 20mm graded stone aggregate for block size 150 mm x 100mm X 150mm, set in Cement Mortar 1:4, with and including necessary form work and all exposed surfaces finished even and smooth without using extra cement including removal of old broken unserviceable PCC block at site complete all as specified & directed. Note : An epoxy insulator shall be fixed on the PCC block with the help of rawal plug & screw to support and fixing the down conductors / earth strips.
M &L in repair for PCC 1:2:4 for & around lightening conductor pipe on roof of building, type B-I using 20mm graded stone aggregateof size 350mm x 350mm X 350mm, set in Cement Mortar 1:4, with and including necessary form work and all exposed surfaces finished even and smooth without using extra cement including removal of old broken unserviceable PCC / block at site complete all as specified & directed. Note : contractor is responsible to arrange his own T&P for carrying the PCC material on roof of any building .
M & L in repair for earth pit of internal size 300mmx300mmx300mm with wall thickness 100mm casting at site with and including PCC base 500X 500X100mm made of PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast 40mm thick RCC cover of (1:2:4) type B-1 (using 20mm graded stone aggregate), rainforced with 8mm dia TMT bars 3 Nos both way with 12mm dia MS round bar handle etc.including removal of old broken unserviceable earth pit from site complete all as specified & directed.
M & L in repair for earth pit cover, pre cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate, 320mm x 320mm x 40mm thick, cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia MS round bar handle with and including necessary form work complete all as specified & directed.
Mild steel screw bolts (machine-made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n, etc 15cm long and dia of 11 to 15mm
Please Enable Macros to View BoQ information
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
tender1638.pdf
Tender Documents • 0.85 MB
BOQ_838448.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid