Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
12 Oct 2024, 6:00 pmClosed
MMD PRAVEEN NANDIKATTI GE AF SARSAWA
Garrison Engineer (AF) Sarsawa, Distt. Saharanpur (U.P)
REPAIR/MAINT OF INTERNAL ELECTRIC WIRING, LIGHT FITTING AND FIXTURES SUBMAIN WIRING, COOLING/HEATINGAPPLIANCES AND LT SUPPLY/ DISTRIBUTION SYSTEM OF LT LINE AND ALLIED WORKS OF EXTERNAL ELECTRIFICATION, DG SET IN PTS UNIT OLD AND NEW CAMPS AREA SARS
2024_MES_666310_2
8124/SAR-T-40/2024-25
Open Tender
Civil Works
Item Rate
330 days
GE(AF) SARSAWA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (AF) SARSAWA
₹90,000
Yes
25 Jan 2025
21 Sept 2024
19 Oct 2024
21 Sept 2024
12 Oct 2024
28 Sept 2024
21 Sept 2024 - 28 Sept 2024
Amount
Taking down carefully copper / aluminium point wiring light / fan, socket or power point complete including fittings such as switches, sockets, ceiling rose, bell push bell buzzer lamp holder bracket etc. removing from site and making good disturbed surface of wall, floor etc complete all as specified and as directed.
M & L for replacement of concealed point wiring complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit ISI marked medium grade not less than 20 mm dia, with MS stove enamelled sunken boxes (normal and modular type as required) including earth dolly with plastic laminated sheet top cover (cover plate with frame in case of modular) of approved make and colour including 1.5 sqmm multi stranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and directed for the followings :- One light / fan point controlled by one way switch
All as per item No 02 here in before but One 5 Amp socket outlet on independent board.
All as per item No 02 here in before but One 5 Amp socket outlet on same board.
All as per item No 02 here in before but One bell/buzzer point controlled by one bell push
All as per item No 02 here in before but One light point controlled by two 2-way switch
All as per above item No-2 here in before but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed.
M&L for replacement of point wiring in casing caping on sufraces of wall/ceiling floor etc complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade with PVC rectangular block of suitable size including 1.5 sqmm multi stranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and as directed for the followings :- One light / fan point controlled by one way switch
All as per above item No-8 here in before but One 5 Amps socket out let point controlled by one 1-way switch on independent board.
All as per above item No-8 here in before but One 5 Amps socket out let point controlled by one 1-way switch on same board.
All as per above item No-8 here in before but One bell/buzzer point controlled by one bell push
All as per above item No-8 here in before but One light point controlled by two 2-way switch
All as per above item No 8 here in befor but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed.
M & L for replacement of existing conduit point wiring complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade drawn through existing conduitwith MS stove enamelled sunken boxes (normal and modular type as required) including earth dolly with plastic laminated sheet top cover ( cover plate with frame in case of modular) of approved make and colour including 1.5 sqmm multi stranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and directed for the followings :- One light / fan point controlled by one switch.
All as per above item No-14 here in before but One bell point controlled by one bell Push
All as per above item No-14 here in before but One 5 Amps socket out let point controlled by one switch on independent board.
All as per above item No-14 here in before but One 5 Amps socket out let point controlled by one switch on same board.
All as per item No. 14 but with 2.5 Sqmm nominal cross sectional area electric cable for 15 Amps socket outlet point controlled by one switch on independent board complete.
S&F in replacement switch piano type 5 amp one way ISI Marked complete all as specified and directed by Engineer-in-Charge.
S&F in replacement switch piano type15 Amps one way ISI Marked complete all as specified and directed by Engineer-in-Charge.
S&F in replacement piano type socket outlet 5 pin 5 Amps flush type complete all as specified and directed by Engineer-in-Charge.
S&F in replacement piano type socket outlet 2-in-1, 6 pin 5 amp and 15 amps all as specified and directed.
S&F in replacement socket outlet 6A-2/3 Pin combined 2 module modular type complete all as specified and directed.
S&F in replacement socket outlet 6A/16A-2/3 pin combined 2 module modular type complete all as specified and directed.
S&F in replacement switch 6 amps modular type one one way complete all as directed.
S&F in replacement switch 16 amps modular type one one way complete all as directed.
S&F in replacement piano type electronic fan regulator Step type complete all as specified and directed.
S&F in replacement piano type bell push flush type 5 amp one way ISI Marked complete all as specified and directed.
S&F in replacement modular type bell push 6 amp one module ISI Marked complete all as specified and directed.
S&F in replacement Bell, DING DONG AC 230 Volts single pole type complete all as specified and as directed.
S & F in replacement of Lamp holder bakalite type with back plate suitable for batten fittings complete all as specified as directed
S&F in replacement of ceiling rose surface bakelite 63 x50mm three terminals complete all as specified and as directed.
S & F in replacement of sub main wiring with PVC insulated, FRLS unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 4.0 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directed with and including one run of 4.0 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed. Note: (i) Two runs of 4.0 sqmm cable and one run of 4.0 sqmm cable of earth continuity conductor and conduit shall be a unit length.
S & F in replacement of sub main wiring with PVC insulated, FRLS, unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 6.0 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directed with and including one run of 6.0 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed. Note: (i) Two runs of 6.0 sqmm cable and one run of 6.0 sqmm cable of earth continuity conductor and conduit shall be a unit length.
S & F in replacement of Regid non-metallic PVC conduit 25 mm (external dia) ISI marked (on surface) incl of all accessories and all fittings such as Tees bends, elbows, reducers, bell mouth, tube ends and fixing accossories such as couplers lock nuts, saddles, pipe hook etc complete all as specified and as directed.
S&F in replacement of sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 12 ways 240 V including fixing in new location with connection of circuit and submain as per site requirement complete all as specified and as directed . Note- (a) MCBs are to be measured and paid seperately. (b)Make of MCBs and DB should be same.(c) Extra circuit length where DBs are to be shifted from existing location to new location shall deemed to be included in the quoted rate. Make-Havells/Indoasian/Legrand,
S&F in replacement of sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 8 ways 240 V including fixing in new location with connection of circuit and submain as per site requirement complete all as specified and as directed . Note- (a) MCBs are to be measured and paid seperately. (b)Make of MCBs and DB should be same.(c) Extra circuit length where DBs are to be shifted from existing location to new location shall deemed to be included in the quoted rate.
S&F in replacement of sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 4 ways 240 V including fixing in new location with connection of circuit and submain as per site requirement complete all as specified and as directed . Note- (a) MCBs are to be measured and paid seperately. (b)Make of MCBs and DB should be same.(c) Extra circuit length where DBs are to be shifted from existing location to new location shall deemed to be included in the quoted rate.
S&F in replacement of single pole and neutral enclosure concealed with 2 pin and metal earth plug and socket complete with one single pole MCB 25 Amp complete all as specified and as directed.
S&F in replacement of Double door concealed three phase distribution board 4 way loadline VTPN when MCCB to be used as incomer and made out of CRCA sheets 1.6 mm thick, phosphatised powder coated with Bus Bar 200 Amps, 415 V, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks , poly layer for protection complete all as specified and directed (Note:-(a) MCCB and MCBs are to be measured and paid for seperately. (b) Make of MCBs and DB should be same.
S&F in replacement of Double door concealed distribution board 4 way TPN when MCB to be used as incomer powder coated with Bus Bar 200 Amps, 415 V, Earth Stud, Din Rail, complete all as specified and directed (Note- (a) MCBs are to be measured and paid seperately. (b)Make of MCBs and DB should be same.)
S&F in replacement MCB SP 5 to 32 Amps, 240 volts curve 'B',breaking capacity 10KA, all as specified.
S&F in replacement MCB SPN 16 to 40 Amps, 240 volts, curve 'B', breaking capacity 10 KA, all as specified.
S&F in replacement MCB SPN 50 to 63 Amps, 240 volts, curve 'B', breaking capacity 10 KA, all as specified.
S&F in replacement MCB TPN 63 Amps, 415 volts, curve 'B', breaking capacity 10 KA, all as specified.
S&F in replacement MCCB , 125 Amps, 4Pole with adjustable thermal setting and rupturing capacity 16 kA complete all as specified and directed.
S & F In replacement of modular switch 2 way, 6 Amp,1 module ISI Marked complete all as specified and as directed.
S & F in replacement of modular Fan Regulator fan step regulator,120W- single module ISI Marked complete all as specified as as directed.
S & F In replacement of Piano type switch 2 way, 5 Amp,1 module ISI Marked complete all as specified and as directed.
S&F in modular blanking plate, 1 module ISI Marked complete all as specified and as directed.
S&F in replacement metal flush box 3 module all as specified and directed.
S&F in replacement metal flush box 6 module all as specified and directed.
S&F in replacement metal flush box 8 module all as specified and directed.
S&F in replacement for white cover plate with frame, 3 module all as specified and directed.
S&F in replacement for white cover plate with frame, 6 module all as specified and directed.
S&F in replacement for white cover plate with frame, 8 module all as specified and directed.
Supply and fixing in repair of Earthing to DBs with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead 4.0 sqmm galvanised iron wire by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead shall be protected by GI pipe 15 mm dia medium grade and connected to distribution board including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and as directed.
M & L in repair for Earth continuity conductor or main earthing lead of 4.0 Sqmm galvanized iron wire, buried in ground or fixed to wall in and including 15 mm bore GI pipe medium grade for protection of earth wire complete all as specified and directed.
S&F in replacement enviroment friendly,ultra modern,energy saving surface mounted decorative 10 Watt LED bulkhead fitting modular type with polycarbonate housing ,high efficient LEDs with opal diffuser and IP65 protectio, lumen efficacy 85 lm/watt with colour temerature 6500K, THD≤ 20 CRI>80,2.5 kV surge protection all as specified and directed.
S&F 9 watt LED bulb with B22 Base cap, 1200 lumens ,Colour rating Index 80,colour temp F 6500K,satrtup time less than 2 sec,In built surge 3.0 kV, voltage range 140V to 270 V , Lamp life 15000 hours complete all as specified and directed.
S&F 12 watt LED bulb with B22 Base cap, 1200 lumens ,Colour rating Index 80,colour temp F 6500K,satrtup time less than 2 sec,In built surge 3.0 kV, voltage range 140V to 270 V , Lamp life 15000 hours complete all as specified and directed.
S&F in replacement of enviroment friendly indoor decorative 20 Watt LED Polycarbonate Batten with opal diffuser , operating voltage range 140v to 270 V, Driver efficiency 88%, lumen efficiency =100 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 2.5 Kv, isolation=3.75, and with zero mercury content including all accessaries all as specified and directed.
S&F in replacement of enviroment friendly indoor decorative 9/10 Watt LED polycarbonate Batten with opal diffuser , operating voltage range 140v to 270 V, Driver efficiency 88%, lumen efficiency =100 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 2.5 Kv, isolation=3.75, and with zero mercury content including all accessaries all as specified and directed.
S & F in replacement enviroment friendly recess/surface mounting 36 watt LED flat panel 2'x2' fabricated CRCA sheet steel duly powder coated housing cool white with high efficient LEDs & glare free opal diffuser PF>0.95 , lumen efficacy>100 lm/W, THD<10% operating range 220v to 240V,CRI>80 including connection with existing wire and all accessaries all as specified and directed.
S & F in replacement enviroment friendly recess/surface mounting 24 watt LED flat panel 1'x1' fabricated CRCA sheet steel duly powder coated housing cool white with high efficient LEDs & glare free opal diffuser PF>0.95 , lumen efficacy>100 lm/W, THD<10% operating range 220v to 240V,CRI>80 including connection with existing wire and all accessaries all as specified and directed.
S&F in replacement of enviroment friendly indoor decorative 5/6 Watt LED polycarbonate Batten with opal diffuser , operating voltage range 140v to 270 V, Driver efficiency 88%, lumen efficiency =100 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 2.5 Kv, isolation=3.75, and with zero mercury content including all accessaries all as specified and directed.
S & F in repair plastic laminated bakelite sheet cover of Hylam brand including cutting holes for switches, sockets etc as pre requirement including fixing with machine screws and washer complete of following sizes:- 10" x 12" size
All as per above item No-67 here in before but 8" x 10" size
All as per above item No-67 here in before but 8" x 6" size
All as per above item No-67 here in before but 7" x 4" size
All as per above item No-67 here in before but 4" x 4" size
M&L for Shifting of existing electric Energy Metrer from existing location to directed location including box and connecting to existing submain circuit complete all as specifed and directed
S&F in replacement of Energy meter Box Flame retardent polycarbonate body including all fixing arrangement like DIN rails mounting plate connection boxes fastning screw protection plate extra suitable to accomodate single Phase energy meter with locking arragement complete all as specified and directed.
Taking down electric energy meter of any size and type and deposite to MES store yard complete all as specified and directed.
Supply and fixing in replacement microprocessor based single phase electronic tamper proof energy meter of rating 10 to 60 Amps, AC 240 Volts, 50 Hz covered with toughened glass cover with optical comunication port confirming to IS 13779 complete all as specified and directed
M&L for flame proof wiring with single core PVC insulated and unsheathed 1100 volt grade FRLS electric cable with multi stranded copper conductor of size 2.5 Sqmm phase and neutral drawn in and including ERW rigid steel stove enameled black conduit heavy duty ISI marked of size 20mm dia on surface/wall/ceiling including all flame proof conduct fittings and accessories such as tees junction boxes, bends duly tested by CMRI Dhanbad suitable for one light /fan point controlled by one flame proof rotary switch SP one way and including drawing continuous earth wire FRLS PVC insulated unsheathed 1100v grade cable with stranded copper conductor of size 2.5 Sqmm and connected to earth dolly complete all as specified and directed by Engrs-in-Charge.
Supply and fixing flame proof/weather proof direct entry type rotary switch single pole on & OFF rotary motion switch in cast aluminum alloy LM-6 enclosure epoxy powder coated single pole 230Volts 10 Amps, AC ON/OFF switch operated externally by Knob having 02 Nos of M-20 cable entries, earthing terminals suitable for mounting on Wall/Steel structure etc all as specified and directed. Make : Flexpro/Sudhir/Baliga/Shyam.
Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed size. Note :- (a) All fittings shall be ISI marked and shall have approval of CMRI Dhanbad . (b) Original Test certificate of Manufacturer shall be produced by Contractor .
M&L for fixing PVC gang box for mounting one switch and one socket of 5 Amps including all accessoriese complete all as specifies and directed.
M&L for fixing PVC gang box for mounting one switch and one socket of 15 Amps including all accessoriese complete all as specifies and directed.
Supply and fixing of PVC Casing capping 20/25mm ISI marked all as specified and as directed by Engineer-in-charge.
S&F in replacement of Cable PVC insulated unsheathed single core 1100V FRLS grade stranded flexible copper conductor of size 1.5 sqmm complete all as specified and directed.
Supply and fixing in replacement of Cable PVC insulated unsheathed single core 1100V FRLS grade stranded flexible copper conductor of size 2.5 sqmm complete all as specified and directed.
Supply and fixing in replacement of Cable PVC insulated unsheathed twin core of 23/0.0076 size flexible copper conductor complete all as specified and directed.
Supply and fixing in replacement of Cable PVC insulated unarmoured three core 1100V FRLS grade stranded flexible copper conductor of size 2.5 sqmm complete all as specified and directed.
Supply and fixing 25 mtr long 2.5 cm wide and atleast .125 mm wall thickness self adhesive PVC insulated electrical tape roll of good quality complete all as specified and directed.
Supply and fixing in replacement of PVC round shape junction box cover of suitable size including fcomplete all as specified and as directed.
Taking down light fittings of any type any size any location complete all as specifed and directed.
Taking down DB including old U/s MCB/MCCB of any size any type from any location complete all as specifed and directed.
S&F in replacement of recesses/suface mounted with ring square/round shape slim downlighter of 12 watt capacity with colour temperature cool day white/warm white as per requirement , Lumens 120, CRI more than 80 as per sample and site requirement including all accessore complete all as specified and directed.
S & F in replacement enviroment friendly recess/pendent mounting 36 watt LED flat panel 2'x2' fabricated CRCA sheet steel duly powder coated housing cool white with high efficient LEDs & glare free opal diffuser PF>0.95 , lumen efficacy>100 lm/W, THD<10% operating range 220v to 240V,CRI>80, Colour Temerature 3500/4000 K (Warm White) including connection with existing wire and all accessaries all as specified and directed.
S & F in repair PVC rectangular block for mounting switches, sockets , fan regulator etc with 3 mm thick plastic laminated sheet cover of following sizes:- 250 x 200 x 50 mm size
All as per above item No-92 here in before but 200 x 150 x 50 mm size
All as per above item No-92 here in before but 175 x 100 x 50 mm size
All as per above item No-92 here in before but 100 x 100 x 50 mm size
S&F in replacement of old unserviceable decorative type wall mounted with new wall comet light fitting without LED bulb pin type B22 cap complete all as specified and directed. Make- Philips 30575 or equivalent
S&F in replacement of 09 watt 2 star LED bulb with B22 /B27 Base cap as required, 1200 lumens ,Colour rating Index 80,colour temp warm white ,satrtup time less than 2 sec,In built surge 3.0 kV, voltage range 140V to 270 V , Lamp life 15000 hours complete all as specified and directed.
S&F in replacement metal flush box 4 module all as specified and directed.
S&F in replacement for white cover plate with frame, 4 module all as specified and directed.
S&F in replacement metal flush box 12 module all as specified and directed.
S&F in replacement for white cover plate with frame, 12 module all as specified and directed.
S&F in replacement of enviroment friendly indoor decorative 5/6 Watt LED round shape downlighter recess/suface mounted operating voltage range 140v to 270 V lumen efficiency =100 lm/watt , THD≤ 20 CRI>80 , colour temperature warm white, including all accessaries all as specified and directed. Make- Crompton/Syska/orient
M&L and T&P for attending complaints related to ceiling Fan, exhaust fan, wall fan, padestal fan etc any sweep, any type, any make fixed at different locations including taking down and refixing, cleaning all dirt, dust etc, replacement of connection lead/wire checkinng for loose connections in circuit, oiling and greasing split pins & other minor items,unserviceable screws assembly,bearing, re-fixing and testing to make it functional complete all as specified and as directed. Note :- 1. Cost of capacitor, connecting wire,regulator,ball bearing ,gun metal bush,ceiling rose etc shall be measured and paid under relevent item . 2.Cost of petty stores such as grease, lubricating oil ,lock nut , cross pin, check nuts,rubber seal etc are deemed to be included in quoted rate.
M&L and T&P for attending complaints related to Geyser any capcity Inspection and maintenance of water heater (Geyser) of capacity, 25 lt to 50 litres including performing the following task at different locations at AF Stn Sarsawa. (a) Removing Geyser & flow unit & heating element & cleaning the inner, tank with suitable acid/Replacement of defective connection lead . (b) Checking and setting of thermostat between 50 to 55 degree Celsius (c) Check working of NRV stop cock, pressure release valve and servicing carefully to make it functional (d) Repairing of earthing connection, power switch, socket connection replacement of indicator lamp to make it functional (e) Examine water leakage and rectifying as required and replacement of rubber washer gasket etc to make it functional (f) Inspect over flow vent pipe, safety valve and remove blockage if required to make it functional. (g) Any other item required for making Geyser serviceable will be measured & paid seperately under respective items. Common Notes for Item No -103 &104 (a) At least 01 electrician with 01 helper for day to day complaint rectification of Fan and Geyser at PTS old and New camp Sarsawa.(b) Contractor must insure sufficient store and T&P for geyser such as pipe wernch,screw driver etc and T&P for fan repair such as bearing puller, Plier,Tester screw driver etc for attending complaint and stationary such as complaint slips, Registers etc.(c) Obtain user signiture on complaint slip and register & submitting the records to the office of Engr-in-charge.
M&L for Taking out of burnt coils of ceiling fan in replacement of all coils of ceiling fan motor, AC, 230 volt of 1200/1400 mm with super enamel copper winding wire of proper gauge, weight etc (having same nos of turns), winding using insulating materials varnishing, heating, baking, replacement of bearing, bush, shaft etc, re-assembling the fan after making it functional and testing ,maintain the speed of fan complete all as specified and as directed
All as per Serial Item No 105 here in above but exhaust fan upto 450mm size/sweep
All as per Serial Item No 105 here-in-above but Wall Mounting fan upto 750mm size/sweep
All as per Serial Item No 105 here-in-above but Pedestal fan of any sweep/size.
All as per Serial Item No 105 here-in-above but cabin fan of any sweep/size.
M&L for spray painting of ceiling fan ,exhaust fan wall mounted,Pedustal fan of any size any type with one coat of synthetic enamelled paint after cleaning and making good the old damaged paint all as directed by Engineer- in Charge.
Fan capacitor up to 1.5 MFD complete all as specified and as directed. Make- Tibcon/Bajaj/Havells
Fan capacitor 2.5 MFD complete all as specified and as directed. Make- Tibcon/Bajaj/Havells
Fan capacitor 3.15 MFD complete all as specified and as directed. Make- Tibcon/Bajaj/Havells
Fan capacitor 4 MFD complete all as specified and as directed. Make- Tibcon/Bajaj/Havells
Ball bearing/shaft suitable/as per exciting sample for exhaust fan, ceiling fan and pedestal fan/wallmounted fan/cabin fan etc complete all as specified and as directed. MAKE : NBC, SKF or equivalent
Gun metal bush for ceiling fan of any size/make/sweep complete all as specified and as directed
Gun metal bush for exhaust fan of any size/make/sweep complete all as specified and as directed
Supply and fixing ‘U’ clamps for hanging ceiling fan with all nuts & bolts, washer, suitable size with rubber real complete all as specified and as directed
Supply and Fix in repairs ceiling fan canopy with nut and bolt of suitable size all as directed and specified.
Supply and fix in replacement of down rod for ceiling fan made out of 15 mm dia MS pipe complete with holes, slotted or threaded from 0.75 mtr to 1.5 mtr long all as specified and directed.
S & F nuts, bolts, washers, in any shape or size as directed including one coats of synthetic enamel paint over a coat of red oxide primer, complete all as directed .
S & F in replacemenmt of Fan blade for ceiling fan 1200/1400 mm sweep as per existing model complete all as specified and directed.
S & F replacement of Fan blade for Exhaust fan metal type any sweep as per as per existing model complete all as specified and directed.
S & F replacement of Fan blade for wall mounted fan any sweep as per as per existing model complete all as specified and directed.
S&F in replacement of metallic exhaust fan louvers of any shape (square or round as per site requirement ) upto 450 mm sweep complete all as specified and directed.
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed by Engr-in-Charge.
S&F exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, 1400 RPM, blades, and frame and louver complete all as specified and as directed by Engr-in-Charge.
Supply & fix wall mounting fans 230 volts single phase oscillating 400 mm sweep suitable for wall mounting complete all as specified and as directed by Engr-in-Charge.
S&F plastic body ventilation fan 250 mm 50 Hz , 240 volt 1250 RPM with copper wound motor including all fixing accessories complete all as specified and directed.
Geyser flow unit / assembley made out of stainles steel as per matching shape/size or as per sample( Normal or modular type) suitable for 25 to 50 litres capacity including safety valve as directed by Engr-in-charge.
copper heating element of rating 1.5 KW to 2 KW to geyser 25 to 50 litres capacity, any type,as per matching shape/size or as per sample( Normal or modular type) make complete all as specified and as directed
Thermostat as per sample suitable for 50/25 litres capacity of geyser complete all as specified and directed.
Flexible SS braided connection havey duty stain steel 15 mm dia, length up to 750 mm long with union at both ends for 15 mm dia pipe complete all as specified and as directed
Red and green indicator lamp as per existing size and shape complete all as specified and directed.
Plug top, 3 pin, 15Amps all as specified and as directed. Make-Anchor/cona/havells
Supply and fixing modular type AC box operated with 20 Amp single pole MCB including 15 amp modular socket complete all as specified and directed by the Engr-in-charge. Make : - Legrand/Havells/ Indo asian
Anchor bolt type fastner brass size 10mm upto 150mm length complete all as specified and directed.
Dismantling the flow unit, inlet,outlet pipe of Geyser & taking out to repair the inner copper/steel tank of capacity 25/35/50 letres storage capacity by brazing at different spots after cleaning rusted leaking places and making tank leak proof including refixing, re-assembling & testing complete all as specified and as directed
Material and labour for painting of geyser 25 to 50 litres capacity with synthetic enamel spray paint with two coats of paint over one coat of red oxide primer including preparation of old surfaces complete all as specified and as directed
Supplying & Fixing of non return valve Brass metal vertical type size 15 mm complete all as specified and as directed
Supply & Fix for insulation of 25 to 50 Ltrs geyser as per existing insulating material in existing quantity for each geyser complete all as specified and as directed by Engineer-in charge.
S&F in replacement of Sheet metal enclosure factory made shutter type distribution board 2way (when MCBs are to be used) single pole and neutral, 240 Volts, with 200 Amp rated busbar, IP 43/IK09 (MCBs are to be measured & paid separately) complete all as specified and directed.
Supply & Fix in replacement of stainless steel water storage tank for upto 50 Ltrs capacity geyser as per existing gauge and shape complete all as specified and as directed by Engineer-in charge.
Supply & Fix in replacement of outer body 18 gauge complete with bottom and top cover as per matching to existing type and size for upto 50 Ltrs capacity geyser. Complete all as specifed & directed
Supply and fix electric water heater, storage type with Glass lined MS tank outer body made out of ABS & PP, heating element of 2 KW storage capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, SS connection piece of suitable length etc complete all as specified and as directed by Engr-in-Charge.
S&F microprocessor based single phase electronic tamper proof static energy meter of rating 10 to 40 Amps, AC 240 Volts, 50 Hz covered with toughened glass cover with optical comunication port confirming to IS 13779 complete all as specified and directed
S&F in replacement of metal clad plug top 240 volts 20 Amps with two phase and neutral pins and one earth pin complete all as specified and directed
S&F in replacement of metal clad socket 240 volts 20 Amps to fix two phase and neutral pins and one earth pin complete all as specified and directed
M&L for making arrangement for fixing of exhaust fan on steel/Aluminium frame window/ making opening in brick wall as per site requirement and also making good to disturbed surfaces as per matching to existing complete all as specified and directed.
Repair and Maintenance of split/Window type AC's of capacity 1.5/2 TR comprising of the following tasks installed at different locations including testing complete all as specified and directed by Engineer-in-Charge.(a) Inspecting and checking the Indoor/outdoor units for noise free operation (b) Checking the electrical connection for tightness (c) Cleaning the condenser with cleaning agent followed with pressurized water and cleaning the cooling coil with air blower.(d) Greasing/Oiling of condenser fan motor and blower motor. (e) Checking for any refrigerant leakage. (f) Checking for serviceability of remote control unit.
Supply and fixing in replacement of starting relay for split type AC units of capacity 2 TR as required at site complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of starting relay for split type AC units of capacity 1.5TR as required at site complete all as specified and directed by Engineer-in-Charge. Make- (1) Hitech (2) Sriram or equivalent
Supply and fixing in replacement of starting capacitor 80-100/100-120 mfd for split type A/C's of capacity 2 TR complete all as specified and directed by Engineer-in-Charge. Make- (1) Tibcon (2) Tesla (3) Epcos
S/F in replacement of running capacitor 30/36 mfd for split/window type AC unit as required at Site and as directed by Engineer-in-Charge. Make- (1) Tibcon (2) Tesla (3) Epcos
Taking out and refixing after rewinding including replacement of bush/ bearings of condenser fan motor of split type AC units of capacity 1.5/2 TR complete all as specified and directed engineer-in-Charge.Make- (1) Hitech (2) Sriram or equivalent
Taking out and refixing after rewinding including replacement of bush/ bearings of blower motor of split type AC units of capacity 1.5/2 TR complete all as specified and directed engineer-in-Charge.
Disconnecting and taking down burnt compressor of capacity 2TR from split type AC unit and Supply and Fix new with charging of refrigerent after dehydration testing and vaccumming one as per existing model complete including testing all as specified and directed by Engr-in-Charge.
Disconnecting and taking down burnt compressor of capacity 2TR with CFC free Refrigerent (R410a,R32,R134a) from split type AC unit and Supply and Fix new with charging of refrigerent after dehydration testing and vaccumming one as per existing model complete including testing all as specified and directed by Engr-in-Charge.
Disconnecting and taking down burnt compressor of capacity 1.5 TR with CFC free Refrigerent (R410a,R32) from split type AC unit and Supply and Fix new with charging of refrigerent after dehydration testing and vaccumming one as per existing model complete including testing all as specified and directed by Engr-in-Charge.
Disconnecting and taking down burnt compressor of capacity 1.5 TR from split type AC unit and Supply and Fix new with charging of refrigerent after dehydration testing and vaccumming one as per existing model complete including testing all as specified and directed by Engr-in-Charge.
M&L for detecting the cause of leakage in any type/capacity of 1.5 tonne AC and ensuring the complete system leak proof and charging of refrigerant gas with appropriate quantity as directed including testing for smooth functioning complete all as specified and as directed. Notes :-(i) Dismantling of serviceable compressor , and re-installation of serviceable compressor after repairing are deeemed to be included in the quoted rates Gas and cost .
Supply & Fixing in replacement of new remote control unit (cordless) with PCB for 1.5/2 TR split type A/C unit complete all as specified & directed by engineer-in-charge.
Supply & Fixing in replacement new blower motor as per sample and existing model for split type A/C unit complete all as specified & directed by engineer-in-charge.
Supply & Fixing in replacement of air filter for split type A/C units of capacity 1.5/2 TR complete all as specified and directed by Engr-in-charge.
Material and Labour for providing sleeve type insulation 9mm thick for any dia copper tubing from Indoor to outdoor units complete all as specified and directed by Engr-in-charge.
Supply and charging CFC free Refrigerant (R410a,R32,R134a) to any type of AC complete all as specified and directed by Engr-in-Charge
Supply and charging R22 Refrigerant to any type of AC complete all as specified and directed by Engr-in-Charge
S&F in replacement the new swing motor of existing model sample for split type AC 1.5/ 2TR unit complete all as specified and directed by Engr-in-Charge
M&L in replacement of copper tubing 10mm outer dia suitable for AC 2TR capacity complete all as specified and directed by Engr-in-Charge Make - (1) total line of carrier (2) met tube (3) diamond
All as per item No 169 but here in before but 15mm outer dia complete all as specified and directed by Engr-in-Charge Make - (1) total line of carrer (2) met tube (3) diamond
Repair & maintenance of water coolers of any capacity comprising of the following tasks at different location complete all as specified and directed by Engineer-in-Charge. (a) Inspection, taking down, opening, dismantling, decaling, brushing cleaning of storage tanks (b) Examination water tightness, leak proof of storage tank after cleaning.(c) Carry out operation of all stop cock, push cock, float valve etc. (d) Inspect overflow and remove blockage if any. (e) Check and correct earth continuity of electric items (f) Check thermostat and test its functioning (g) Inspect drain pipe and remove blockage if any (h) Check and correct all electrical wiring & test its functioning (i) Testing of water cooler after repair
M&L for detection/rectification of leakage of gas in the system and gas charging in the system with appropriate quantity of gas including testing for smooth functioning of water cooler of any capacity complete all as specified and as directed at site by Engineer in charge. Note:- (i) Unserviceable condensing coil if required shall be measured and paid separately. (ii) The cost of dismantling of unserviceable compressor if required deemed to be included in unit rate. (iii) Compressor shall be measured and paid separately under respective items of Sch "A"
Supply & fixing in replacement of thermostat switch for existing model sample as required at site complete all as specified and directed by Engr-in-Charge.
Supply and Fixing in replacement fan motor capacitor 2.5/3.15mfd. complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of overload protector for compressor of water cooler of any capacity as reqd at site complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of starting relay as required at site for water coolers of any capacity complete including connecting, testing complete all as specified and directed by Engr-in-Charge.
Disconnecting and rewinding of condenser motor single phase of 1/16 HP for water coolers & refixing the same with clamps bolts, nuts and rubber bushes including connecting, testing complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of CP push cock ISI marked 15mm base complete all as specified and directed by Engr-in-Charge
Supply and fixing in replacement of starting capacitor 100/120 mfd for compressor complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement of new condenser motor single phase of 1/16 HP as required at site for water cooler with clamps, bolts, nuts & rubber bushes complete including connecting testing complete all as specified and directed by Engr-in-Charge.
S&F in replacement of water cooler compressor reciprocating type (hermetically) sealed for any capacity as required at site water cooler complete all as specified and as directed.
Repair & maintenance of voltage stabilizer of capacity upto 5 KVA comprising of the following tasks at different location complete all as specified and directed by Engr-in-Charge. (a) Rewinding of Transformer copper coil with new copper wire as per existing gauge (b) Time delay relay-01 No. c) Cut out relay-01 No. (d) printed citcuit relay- 01 No.
S&F in repair/replacement of voltage stabilizer of 5 KVA capacity complete all as specified and directed by Engr-in-Charge. NOTE- Old stabilizer will be deposited to MES store.
Dismantling of Split type AC 1.5/2.0 TR capacity from position after including disconnecting all connections between indoor and out door units,shifting,backup refrigerant for reuse and install at a place where directed carefully,including cutting on wall,making hole and make good disturbed surface properly matching surface,inspecting,servicing and refilling refrigerant and testing complete all as directed by Engr-In-Charge.
S&F in repair/replacement of indoor unit of 1.5/2 TR capacity split AC 230 Volts single phase all as specified and directed.
S&F PCB card suitable for existing split type AC 1.5/2 Tonne AC of any make/model complete all as specified and as directed.
S&F PCB suitable for 5 KVA voltage stabilizercomplete all as specified and as directed at site by Engineer in charge.
S&F new transformer in replacement of burnt out transformer of 5 KVA voltage stabilizer complete all as specified and as directed at site by Engineer in charge.
Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide & not exc 1.5 mtr deep and getting out for taking out/laying cable, poles & stay etc complete all as specified and directed by engr-in-charge.
Returning, filling in including spresding leveling watering and well ramming in layers not exceeding 25cm thick after the cable have been laid and tested complete all as specified and directed by Engr-in-Charge..
Removal of excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.
M & L for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying ( total 23 cm ) and compaction till 18 cm thick for measurement purpose complete all as specified and directed .
Material labour for common burnt clay bricks, sub class 'B' grade laid in trenches for protection of UG cables perpendicular to the direction of the cables complete all as specified and as directed by Engr-in-Charge
M & L for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation of pole or similar works complete all as specified and directed.
M & L for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete for fixing of pole complete all as specified and directed.
M & L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for copings of poles/stay/panels complete all as specified and directed.
M&L Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armourend aluminium conductor cable of size 240 sqmm to 300 sqmm .
M&L Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armourend aluminium conductor cable of size 240 sqmm to 300 sqmm .
S&F Danger notice plate of 1.6mm thick mild steel sheet vitreous enameled white with letter figures and conventional skull and bones in signal red colour and fix with MS clamp for HT size 25 X 20 Cm and taking out of us one complete all as specified.
M& L for Disc type insulator, porcelain, vitreous, white, brown or green insulator ( Single disc assembly ) of size 145 mm height, 255 mm dia ball socket type for working pressure 11 kv volts grade including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut and taking out of U/S one complete all as specified.Make -PACTIL / MADRAS PORCELAIN / NGEF / JAIPURIA / BHEL .
Supply & fix lightening arrestor linear resistance type distribution class 9 KV RMS suitable for 11 KV system pole mounting type conforming to IS - 3070 Part-I including taking down existing U/S one . Make - BHEL / CG /BHARAT BIJLEE / OBLUM / PRAGATI .
S/F drop out fuse assembly complete set with Insulator-06 Nos and connected accessories for 11000 V grade of 400 Amp s capacity including taking down U/S DO fuse assmbly.Make - BHEL / JAIPURIA / RASHTRIYA / MEI .
Expulsion fuse single pole capacity of Voltage 11KV and current up to 25 Amps.
Ditto as per item No 202 but capacity of Voltage 11KV and current above 25 & upto 50 Amps.
Ditto as per item No 202 but capacity of Voltage 11KV and current above 50 & upto 100 Amps.
Taking down and repairing/overhauling of air break gang operated switch with DO fuse unit 200 Amp/400 Amp capacity triple pole mechanically operated mounted on insulators and steel frame installed vertically / horizontally , replacement of broken/worn-out components, oiling and greasing of mechanical moving parts, smoothing and polishing of electric contacts with providing conducting jelly of contacts refixed the same after repair including proper allienment complete all as directed. ( Note:- Warn out component/ insulators shall be measured and paid separately)
Supply only following components to incorporated for repair of air break gang operated switch :- Female contact or fixed contact heavy duty and high conductive metal complete capacity 200A/400 Amp11 KV Make Rastriya/Jaipuria or equivalent
All as per above item No-207 here in before but Male contact or Moving contact heavy duty and high conductive metal complete capacity 200A/400Amp 11 KV . Make Rastriya/Jaipuria or equivalent
All as per above item No-207 here in before but Tinned copper flexible jumper 200A/400A Make Rastriya/Jaipuria or equivalent
All as per above item No-207 here in before but Fixed top contact & Fixed bottom contact 11 KV 400 Amp for DO fuse unit. Make Rastriya/Jaipuria/equivalent
All as per above item No-207 here in before but Fiber glass tube with metalic fittings both ends suitable for DO fuse 11KV Make Rastriya/Jaipuria/ equivalent
All as per above item No-207 here in before but Supply only mild steel jumper carrier as per sample. Make Rastriya/Jaipuria or equivalent
All as per above item No-207 here in before but Supply only back connector plate as per sample.
All as per above item No-207 here in before but Supply only post insulator 11 KV as per sample.
Disconnect HT & LT connections from any type of transformers indoor/outdoor, plinth/ pole mounted in any location in the restricted areas of PTS shifting to workshop for carry out any repair works, as directed install back in original location including re-connection of HT & LT supply system of capacity complete all as specified and directed. 200 KVA
All as per above item No-215 here in before but dry type 315 KVA Note:- (a) Required tools & plant including lifting arrangement, transport etc shall be included in the rate quoted. (b) Any damage occurred during lifting/ transporting, the firm will be responsible to rectify such defect free of cost.
Shifting of trolly mounted transformer to the site and disconnecting the defective transformer from HT and LT side connection and connecting the trolly mounted stand by transformer by making neccessary HT /LT side connection properly for temporary basis and disconnecting the same after repair of removed /issolated transformer and connecting work shop repaired transformer complete all as specified and as directed.
Repair / Servicing / maintenance of transformer 11 / .433 KV indoor / outdoor type , plinth / pole mounted type including the following work services :- (a) Disconnecting transformer from electric system and providing electric power to user from alternative arrangement including taking out from existing position . (b) Decanning of transformer oil , opening top cover , disconnecting of all internal connections , lifting and taking out of core assemble , LT / HT bushsing , Tap changer etc ,cleaning and inspection of core and winding , segrigetion of serviceable and unsv items , removing of sludge and cleaning tank and cooling pipes / fins /tanks with pressure water and drying the tank complete . © Replacing Unsv LT / HT bushing by replacing rubber / cork oil seals and damage terminal rod & replacement of Transformer cover gasket of rubber cork sheet . (d) Re installation of TFR including reassembling of core / winding assebly complete including replacement of unsv parts , repair the defective parts and tighting of all loose / sparks wire / nut bolts etc and refixing the to the existing position , connecting with HT/LT cables and earthing strip and testing complete including necessary Transportation ( If required ) to the work shop and back and including Dehyderation and refilling of existing or new transformer oil of required quantity . Transformer capacities 200 KVA
All as per above item No-218 here in before but Transformer of capacity 315 KVA NOTE FOR ITEM NO 218 :- (i) Dehydration of oil and new Transformer oil shall be measured and paid seperately . (ii) Transportation of TFR measured and paid seperately . (iii) HT & LT Busing , Tap Changer will be measured & Paid separataly. (iv) In case HV / LV Winding found damages then Contactor shall be made serviceable with new winding and the same will be measured and paid seperately . (v) The rate of corck sheet & Packing Material for following cap of TFR are included in coated rate for 200 KVA transformer.
Removing of existing damage insulating material from LV Winding , Cleaning the winding and reinsulating the LV Winding with approved grade and make of insulating paper and heating the coil in the heat chamber to obtained desired result of insulating resistence complete and re-installation .
Material and winding of HV side copper winding with super enammeled copper wire of existing size , gauge and weight of approved grade wire including necessary insulating material and heating the coil in the heat chamber to obtained desired result of insulating resistence complete and re-installation .
Material and winding of LV side copper winding with existing size / type and weight of copper strip winding of approved grade including rapping of insulating tap and insulating material and heating the coil in the heat chamber is obtained desired result of insulating material . NOTE FOR ITEM NO 220 & 222: - (i) Contractor shall be open the core assrmbly and segrigatted the serviceable / unser winding and shown to the EIC before and after incorportation to the TFR . (ii) Actual weight of the new winding shall be measured and paid . (iii) In case of damages of the LV Windings and required re insulation of LV Winding then shall be measured and paid seprrately .
Supply and replace of silica gel cristal complete all as specified and directed.
Supply and fixing in repalcement of heavy duty breather assembly with Silica jel cristal for Transformer as per existing shape and size complete all as specified and directed.
Supply and fixing of new temprature guage ( 0 degree to 120 degree C ) range dial temprature as directed including taking down old unserviceable guage.
M & L for transformer oil level indicator assembly complete with iron frame, glass, rubber packing sheet, nuts, bolts and washers etc as per existing.
M&L for Synthetic insulating rubber mat of size 2 m x 1m x 2.5 mm thick with ISI mark suitable for 11 KV rating in red colour complete all as specified and directed .
Materials and labour for removing the burnt out/ damaged LV bushes with porcelain insulator and replace with Brass LV bushes, nuts , check nuts, rubber washer etc complete as per the existing size / model, for transformers of capacity complete all as specified and directed. 200 KVA
All as per above item No-228 here in before but 315 KVA
Materials and labour for removing the burnt out/ damaged HV bushes with porcelain insulator and replace with Brass HV bushes, nuts , check nuts, rubber washer etc complete as per the existing size / model, for transformers of capacity complete all as specified and directed. 200 KVA
All as per above item No-230 here in before but 315 KVA
Dehydration of 11 KV existing transformers oil minimum three cycles to achieve dielectric strength up to 60 KV in 2.5 mm gap electrode including toping up of oil if required at site . Note for item no - 221 (i) Dehydration of transformer oil shall be carried out at site and contractor shall be taken the testing result before and after dehydration of oil and shown to the EIC at site and maintain necessary documents for record . (ii) Dehydration Machine with all T&P & Transformer oil testing machine for dehydration of Transformer oil and necessary transportation for the machines is arrange by contractor . (iii) Oil required for topping up the transformer stabilizer will be measured & paid separatly
Supply and topping up of new low viscosity transformer oil from sealed drums confirming to IS 335-1993 Part-II after testing the correct dielectric strength up to 60 KV at 2.5 mm gap duly de-hydrated complete all as specified and directed.
Off load Tap changer switch of existing model / type of Transformer of capacity 200 KVA .
Off load Tap changer switch of existing model / type of Transformer of capacity 315 KVA . NOTE FOR ITEM NO 234 to 235 :- (i) Fixing charges will be includede in item quOted in 209 .
M&L for preparation of old painted surfaces steel by brushing/changing stain, greasy spots with thinner and apply two coats of spray painting with super enameled smokes grey colour paint of approved make by Dept.for indoor/outdoor transformer installed at various different locations complete all as specified and directed at site. 200KVA
All as per above item No-236 here in before but CSS 315 KVA
Calibration of Protective relay programmable type in CSS panel with carrying out secondary injection test, set the relays in accordance with the supply agency Protection/Tripping range so as to trip the MES breaker before tripping the fault to supplier grid/ system. All parameter in MES breaker tripping setting in relays shall be arranged in such away that any fault occured in the feeders after the recieving station must not transfer to the suppliers system.
Supply and install capacitor metalized poly propylene ultra heavy duty (LTXL) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% complete all as specified. Make : L & T , neptune ,Epcos & equivalent of other approved makes. 25 KVAr
All as per above item No-239 here in before but 10 KVAr
All as per above item No-239 here in before but 5 KVAr
All as per above item No-239 here in before but 3.5 KVAr
All as per above item No-239here in before but1.67 KVAr .
Supply and fix in repair 3 phase 24 -240 Volts AC/DC supply over current + earth fault relay with high set having define time characteristics and last 30 trips data recording with date and time as well as password protection complete including necessary electric connections and testing all as directed as specified.
M&L supply and fix in repair heavy duty Contractor for three phase capacitors including necessary connections all as directed for the following capacity 3 pole power contactor type MNX-110.
All as per above item No-245 here in before but 3 pole power contactor type MNX-70.
All as per above item No-245 here in before but 3 pole power contactor type MNX-32.
All as per above item No-245 here in before but 3 pole power contactor type MNX-18.
All as per above item No-245 here in before but MCB TP of 63 ams of C series .
All as per above item No-245 here in before but Unsheathed single core Copper wire of 10sqmm .
Maintenance / repairs to APFC panels, 3 phase AC 415 V, by skilled technician and replacement of unserviceable spares as specified below for capacities 60 to 100 KVAR including replacement of short circuited copper conductor cables with appropriate gauge PVC insulated stranded copper conductor cables and cleaning of all moving contacts of relay contactors, tightening of all terminals and testing afer repairs to ensure serviceability and corrected output at specified power factor all as specified and directed at site.
M & L for Earthing to OH/Sub stn with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead GI wire 4 mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.5 of MES Schedule pt-I 1991, GI earth lead wire protected by GI pipe 15mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete Note : Main earth lead beyond 7.5 meter shall measured and paid saperatly.
M & L Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw.
M & L for Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground
Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground.
Supply & Fix shock treatment chart standard size with diagrams and illustrations dully framed properly laminated including hooks for fixing/ fastening. The detail illustrations shall be in Hindi & English all as directed and as specified.
Supply and fix in repair ACB 4 pole 415 volts , 800 amps , AC 50 Hz with breaking capacity 50 KA conforming to IS/IEC-60947-2 with themal magnetic release and manual drawout type ( Thermally adustable type ) inclding electrical connection as per site requirement complete all as specified and directed . Make - L&T / ABB / Siemence .
M&L Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armourend aluminium conductor cable of size 240 sqmm to 400 sqmm . Make - Rayche / DENSION / M SEAL .
Supply , laying & testing in repair for XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 16 Sqmm nominal cross section x 2 core.
All as per item no. 259 but Size 25 Sqmm X 3.5 core
All as per item no. 259 but Size 35 Sqmm X 3.5 core
All as per item no. 259 but Size 70 Sqmm X 3.5 core
All as per item no. 259 but Size 400 Sqmm X 3.5 core
All as per item no. 259 but Size 120 Sqmm X3.5 core
All as per item no. 259 but Size 240 Sqmm X3.5 core
Supply and fixing of GI tubing, light grade, 40 mm bore with all fitting lais in trenches / pole / wall for protection of cables in repairs complete.
Supply and fixing of GI tubing, light grade, 80 mm bore with all fitting lais in trenches / pole / wall for protection of cables in repairs complete.
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material of tubular sleeve version and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 25 to 50 sq mm complete . Make- RAYCHEM / Denson /MSS/M Seal
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material of tubular sleeve version and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 70 to 150 sq mm complete .Make- Recmay / Denson /MSS/M Seal
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material of tubular sleeve version and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 185 to 400 sq mm complete .Make- Recmay / / Denson /MSS/M Seal
Supply and fixing steel tubular pole, swaged, complete with cast iron base plate, finial taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC including numbering of poles with two coats of synthetic enamel paints, type 410-SP-31 (9 meter long) complete, Including disconnecting and taking out old damage PCC pole all as directed . Note for item no -Earth work and PCC shall be measured and paid separately as these respectively.
Supply and fix ON load four pole changeover switch with front handle of 4 pole 415 volt 50 Hz 250 amps in SS Enclosure and Conforming to IS/IEC : 60947-1 & 3 complete all as directed .
Supply and fix ON load four pole changeover switch with front handle of 4 pole 415 volt 50 Hz 200 amps in SS Enclosure and Conforming to IS/IEC : 60947-1 & 3 complete all as directed .
Supply and fix ON load four pole changeover switch with front handle of 4 pole 415 volt 50 Hz 125 amps in SS Enclosure and Conforming to IS/IEC : 60947-1 & 3 complete all as directed
Supply and fix ON load four pole changeover switch with front handle of 4 pole 415 volt 50 Hz 100 amps in SS Enclosure and Conforming to IS/IEC : 60947-1 & 3 complete all as directed .
S&F Danger notice plate of 1.6mm thick mild steel sheet vitreous enameled white with letter figures and conventional skull and bones in signal red colour and fix with MS clamp for LT size 20 X 15 Cm fix in repairs complete all as specified.
Supply only Aluminium lugs of any type complete all as per of sample of following sizes :- 16 Sqmm
All as per above item No-277 here in before but 25 Sqmm
All as per above item No-277 here in before but 50 Sqmm
All as per above item No-277 here in before but 70 Sqmm
All as per above item No-277 here in before but 95 Sqmm
All as per above item No-277 here in before but 120 Sqmm
All as per above item No-277 here in before but 150 Sqmm
All as per above item No-277 here in before but 240 Sqmm
Supply & Fixing in repair including making connection testing and commissioning of new MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA. Note: (a) make of MCCB shall beas per appx"D" any other make as per the make in the existing plannel board or exactly suitable to the existing frame size. In case only one particular make is procuring by the bidder necceasry alteration required to fix the same at no extra cost shall be done by the bidder .(b) Type of MCCB weather with operating knob or handle type shall be procured as per site requirement.
All as per above item No-285 here in before but MCCB TP 160 Amps, 36 KA with Adjustable thermal setting ( 80 to 100 %) complete.
All as per above item No-285 here in before but MCCB TP 250 Amps, 36 KA with Adjustable thermal setting ( 80 to 100 %) complete.
All as per above item No-285 here in before but MCCB TP 125 Amps, 36 KA with Adjustable thermal setting ( 80 to 100 %) complete.
All as per above item No-285 here in before but 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA.
All as per above item No-285 here in before but 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA.
All as per above item No-285 here in before but but 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA.
M & L Air termination of Lighting conductors, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed .
M & L Air termination, single pointed, copper rod 12mm dia and 300mm long complete all as specified and directed .
M&L for inspection , servicing and repair of DG sets with B check of the following capacities including minor repairs and replacement of worn out spares such as fuel filter, hose pipes, injector nozzles, cut out, electrical wiring, self starter, dynamo / alternator and tightening of nut bolts, washers, tappet adjustments, cleaning of head assembly including and de-carbonising, inlet and exhaust valves, grinding of valve seats, changing of lubricating oil, etc; complete including testing on load all as directed. 125/100 KVA capacity
All as per above item No-294 here in before but 250KVA Capacity Notes for srl item No.- 294 (i) Spares incl E/Oil required shall be measured and paid seperately under respective items of Schedule. (ii) The POL required for for carrying out test after repairs will be issued by the department. (iii) Testing of DG sets up to working load will be carried out after carrying out repairs to the entire satisfaction of the Engr-In- Charge. (iv) The rate quoted includes for all essential materials which are not otherwise specified in this schedule but are required to ensure smooth functioning of the DG Sets. (v) All T&P, manpower and transport required to carry out the work at site including loading , un-loading etc; will be provided by the contractor. Cost of the same is deemed to be included in the quoted rates. (vi) All additional spares oil filter, air cleaner, oil pump repair kit, V- belt, Oil pipes, fuel pipe, water pump, head gasket kit,etc as required will measured and paid seperately.
Supply and fix in replacement oil pipe (Copper flexible tube) with check nuts for DG sets of any make / capacity complete all as specified and as directed.
Supply and replace 'V' belt as per sample for DG sets of following capacity:-125/100 KVA capacity
All as per above item No-297 here in before but 250 KVA Capacity
Supply and replace fuel flexible pipe, FIP to Filter, heavy duty with check nuts and benjo bolts, for DG sets of capacity upto 250 KVA.
Supply and replace air cleaner filter assembly complete suitable for DG set of of following capicity :- 125/100 KVA capacity
All as per above item No-300 here in before but 250 KVA Capacity
S & F in repair oil pressure gauge compleete all as specified and as directed.
S & F in repair temperature gauge compleete all as specified and as directed.
S & F in repair lub oil filter for DG sets of any make / capacity compleete all as specified and as directed.
S & F in repair fuel filter for DG sets of any make / capacity compleete all as specified and as directed.
S & F in repair ignition switch, 12 V with keys compleete all as specified and as directed.
Dismantling and taking down radiator assembly from engine of DG Set for repairs including de-scaling, bracing of inner tubes and body as required to plug leakages, repairs to radiator frame and tank including cutting and removing deteriorated inner tubes, chamber, frame etc. and re-constructing the same with same material in original size and shape, cleaning / straightening of fins and re fixing after repairs including replacement of worn out nut bolts, washers, aluminium water elbow, radiator cap, radiator beds etc; and pressure testing for leakage complete all as directed for capacity :- 125/100 KVA capacity
All as per above item No-307 here in before but 250 KVA Capacity
Supply and fixing in replacement, radiator assembly complete including all accessaries such as radiator core comprising copper tubes, fins, upper and lower tanks, radiator frame, inlet and outlet pipes, radiator cap etc,complete all as directed for capacity. Make - Kirloskar or eqivalent 125/100 KVA DG set .
All as per above item No-309 here in before but 250 KVA DG Set
Supply and replace of maintanance free unserviceable battery 12 V, 150 AH with initial charging and testing compleete all as specified and as directed. Make: Amaron/Exide/Microtek.
Supply and replace of maintanance free unserviceable battery 12 V, 90 AH with initial charging and testing compleete all as specified and as directed. Make: Amaron/Exide/Microtek.
M & L for cleaning of fuel tank of DG sets emptying the fuel carefully and removing all sedimented particles including scales using wire brushes and kerosene including replacement of worn out transparent fuel level indicating tube including necessary fixing arrangements and marking fuel levels on the tank using white synthetic enamel paint all as specified and directed. 125/100 KVA capacity
All as per above item No-313 here in before but 250 KVA Capacity
M&L for replacement of battery terminal of brass suitable for 12V, 90 AH to 150 AH battery all as specified and directed.
M&L for replacement of battery lead, copper conductor, single core, 25 Sq mm, multi stranded, PVC insulated with suitable terminals at both ends of lengths as per site requirements all as specified and directed.
Supply and fixing in repairs rubber hose pipe kit complete for radiator suitable for DG Sets of following capacity:- 125/100 KVA capacity
All as per above item No-317 here in before but 250 KVA Capacity
Supply and fillling coolent suitable for DG set complete all as specified and directed. Make-: Castrol / Servo / HP
Supply in replacement, Engine oil, multi grade 20 W 40 or equivalent grade of make : Castrol / Servo / HP
M&L for attending complatints of street light, flood light, mounted at any height in pole/hanger in old/new camp of PTS by checking connection , serviceability of fittingd, SMC boxes , MCB, thimbles or any other minor fault complete all as specified and directed. Note- (a) Arrangement of Ladder shall be done by contractor. (b) Arrangement of hydra or other T&P for attending complaints of Hanger light shall be done by contractor.(c) one electrician and one helper shall be deployed at PTS for attending Street light complaints till the completion of Contract.
Supply and fixing LED type street light 35 watt 230 watt volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed.
Supply and fixing LED type street light 60 watt 230 watt volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed..
Supply and fixing LED type street light 90 watt 230 watt volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed..
Supply and fixing LED type flood light 70 watt 230 watt volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed..
Supply and fixing LED type flood light 100 watt 230 watt volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed..
Supply and fixing LED type flood light 120 watt 230 watt volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed..
Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 class protection with aluminium die cast housing cum heat sink circular canopy and clear acrylic cover for 360 degree indirect uniform glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total system lumen not less than 3200 lumens lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed..
Supply and fixing LED Bollard 10 watt 230 watt volts AC outdoor type with decorative for 360 degree indirect light IP 65 class protection with aluminium die cast housing cum heat sink circular at the top and opaque acrylic cover for 360 degree indirect uniform glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total system lumen not less than 3200 lumens lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed. Note- Earth work and PCC shall be included in quoted rate.
S&F in replacement of PVC SMC boxes with hinged door fixing of size 333mmx233mmx120 mm with MS clamp made to shape with necessery nut bolts and washers complete comprising of Aluminium busbar 63 Amps capacity of suitable size mounted over porcelain insulator with nut bolts & washers incl MCB 6 Amps and making incoming and outgoing connections by taking out loops of cable of any size incl necessary excavations and other civil works all as specified and directed. Make- 1.Sintex 2.Universal 3.SMS
S&F in Rep/Replacement of cable PVC insulated unarmored for connection 2.5 Sqmm 3 core copper conductor duly drawn from junction box to street light fitting on poles in PVC Flexible pipes complete all as specified and directed.
M&L for scrapping of surface of steel tubular poles of any size with emery paper and painting of poles with one coat of primer and two coats of aluminium paint of approved make incl writing pole nos on white backgrounds with black paint , complete all as specified and directed.
S&F driver circuit of any make or any model on existing LED street light luninatrie of wattage 45 to 120W complete all as specified and directed.
S&F driver circuit of any make or any model on existing LED Flood light luninatrie of wattage 60 to 180W complete all as specified and directed.
S&F surge protector of any make or any model on existing LED street/Flood light luninatrie of wattage 45 to 120W complete all as specified and directed.
M & L for replacement of street light bracket made out of 40 mm dia light grade GI pipe bend to shape not less than 1.8 mtr length along with 02 Nos fixing clamps properly shaped and fabricated out of 50 x 5 mm thick MS flat nut & bolts duly painted with 2 coats of aluminium paint over 1 coat of red oxide complete all as specified and as directed.
Comprehensive, preventive and periodical maintance of 32 nos Motorised outdoor camera ( 5 MP and 2 Mp) electrically operated including DVR system , stand , HDMI cable , Recording Device , storage device with reliable and efficient operating condition by regularly examine all the parts and other electrical parts including complete servicing of any make and size by using techniques and expertise consultancy including replacement of any type of spares parts electrical or electronic as and when required all as directed and specified to the entire satisfaction of Enginee-in-Charge. Note- (i) Agency Rep will visit once in a month for entire period of contract and report for checking / replacement of Parts shall be submitted to Engr-in-Charge. (iii) Contractor has to submit the AMC documents to the Engr-in-Charge within 15 days from the award of contract. Failing which shall attract the penalty of Rs 500.00 Per day. (iv) AMC shall be done through OEM or any expert agency in the field.
Attending complaints of no water / leakage of water by removing float valve, water meter, stop cock etc or GI/composite tubing of size 15mm to 20mm bore upto 0.3 mtr length including all GI fittings like elbow, socket, Tee, Nipple, bend, union etc and making new threads as required at site including excavation,return refilling and removing soil & earth work etc. complete all as specified and directed.
All as per item No 338 but for 25mm bore
All as per item No 338 but for 40mm bore
All as per item No 338 but for 50mm bore
All as per item No338 but for 80mm bore NOTE for Ser item No 338 to 342 : - (i) The cost of GI pipe upto 0.3 mtr and GI fittings shall be included in the quoted rated. (ii) Excavation and earth work required shall be measured and paid seperately. (iii) Complaints of urgent nature will be attended round the clock including Sunday & holiday to restore the water supply. (vi) Dewatering of accumulated water using engine driven pump set etc is deemed to be included in quoted rate. (v) Complaints given to contractor shall be rectified within 24 hrs. (vi) A penality of Rs 500/- per complaint will be charged for not attending the complaints and complete all as specified and directed.d within 48 hours. (vii) Contractor will arrange all the T&P/Diesel pumps for dewatering where ever required.
Material and labour of Run lead joints in repair including extracting old lead while removing the old joint to the following bores of water Supply Lines with spigot & socket ends including necessary earth work excavation in soft loose soil up to 1.5 mtr width and 1.5mtr depth returning and filling and well ramming including watering as required complete all as specified and directed by Engr-in-Charge. Note:- (i) The Joints are meant for laying new / old pipe & fittings and where Independent leaking joints to be ordered. (ii) Old lead as retrived may be used by the contractor under this item. Additional lead as required shall be arranged by the contractor. (iii) Excavation and earth work for independent joints shall be measured and paid separately. Pipe of 80mm bore
All as per above item No-343 here in before but Pipe of 100mm bore
Run lead joint to the following bore CI pipe with spigot & socket ends complete all as specified & directed. Pipe of 80mm bore
All as per above item No-345 here in before but Pipe of 100mm bore
All as per above item No-345 here in before but Pipe of 150mm bore
Supply and fixing 'D' joint complete set including nuts/bolts and rubber ring for repair to GI/ CI / DI pipe line of following size complete all as specified. Note:- Exc and earth Work shall be measured and paid separatly. Pipe of 50 mm bore
All as per above item No-348 here in before but Pipe of 80 mm bore
All as per above item No-348 here in before but Pipe of 100 mm bore
All as per above item No-348 here in before but Pipe of 150 mm bore
Lifting / taking out the defective submersible pump motor set of any capacity and description / make, any depth from bore well by lifting tolls , chain pulley etc all as required carefully, by disconnecting / dismantling all electric connections, column pipes of size 100 mm etc and transporting the defective pump motor set to workshop, lowering the same /repaired/ new serviceable submersible pump or motor set to the existing location including replacing the rubber packing/ GI nut bolts of the column pipes etc of suitable size where ever required complete all as specified and as directed by Engr-in-charge.
M&L and T&P for rewinding of submersible motor 15 Hp complete all as specified and as directed by Engineer-in-Charge.
M&L and T&P for repair of submersible pump 15 Hp including seals, bush, bearings impellers etc complete all as specified and as directed by Engineer-in-Charge.
S&F in repair/replacement of submersible cable with size 4 Sqmm 3 core all as specified and directed
Comprehensive, preventive and periodical maintance of 10 nos electrically operated RO of capcity upto 15 LPH installed at SG to be maintained round the clock as described here-in after in reliable and efficient operating condition by regularly examine all the filters , pumps , tanks ,all filters such as sediment filter, carbon filter, RO membrane, post carbon filter, UF hollow fibre membrane and FRT, UV filter and other electrical parts including complete servicing of existing RO of any make and size by using techniques and expertise consultancy including replacement of spares parts such as all the filters , pumps , tanks ,all filters such as sediment filter, carbon filter, RO membrane, post carbon filter, UF hollow fibre membrane and FRT, as and when required all as directed and specified to the entire satisfaction of Enginee-in-Charge. Note- (i) Agency Rep will visit once in a month for entire period of contract and report for checking / replacement of Parts icluding TDS level shall be submitted to Engr-in-Charge. (ii) Entire kit shall be replaced once in a contract period for each RO and report shall be submitted to Engr-in-charge. (iii) Contractor has to submit the AMC documents to the Engr-in-Charge within 15 days from the award of contract. Failing which shall attract the penalty of Rs 500.00 Per day. (iv) AMC shall be done through OEM or any expert agency in the field and parts/Kit shall also be procured from perticular make of RO. only. (v) The cost of Minor repair and parts such as wire, grease, thimbles, connectors,pipe upto 0.5 RM length, bends, elbow etc shall be included in quoted Rate.
S&F in replacement of RO membrane 4040 suitable for industrial RO plant complete all as specified and directed.
S&F in replacement of wonded cartage 2020 suitable for industrial RO plant complete all as specified and directed.
S&F in replacement of MGF media suitable for industrial RO plant complete all as specified and directed.
S&F in replacement of Activated carbon 900iv suitable for industrial RO plant complete all as specified and directed.
Supply & Mixing antiscalant/antifoulant for use in industrial RO plant to minimize acid feed for scale control with pale yellow to yellow colour , pH 2.0 to 4.0 specific gravity 1.10 to 1.20 soluble in water non -flammable complete all as specified and directed.
SUBHASH CHAND CONTRACTOR (BID ID -3129309)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .