Loading…
Loading…
Tender Value
₹56.9 L
EMD Value
₹1.1 L
Closing Date
19 Jun 2026, 1:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TECHNICAL
15 conditions · 4 needing a document upload
Clause Regarding GST: (a) All the Bidders/tenderers should ensure that they are GST Compliant and their quoted tax Structure are as per GST LAW.(b) Tenderer Should Furnish their GSTIN numbers representing the States in Which they are registered GST, along with address of Registered Office.(c)The Contract is under GST Act and rules as applicable time to time.
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. Annual Contractual Turnover Data for the Previous 3/4 Years should be submitted as per Annexure-IX.(Annexure- VIB of Tender Documents)
39 conditions · 11 needing a document upload
Check List: The tenderer(s) would fill up the check list, as per Annexure-XXIII to ensure that they are submitting the complete tender offer.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Shifting of CLS panel to New EI Building at 7 Nos of Stations (SPGN, SLGR, AGI, NCH,TTB, NTSK,TSK).
LV-T-14-TSK-926-R~NFR
LV-T-14-TSK-926-R
Open
Works - General
12 Months
Tinsukia, Assam
₹0
₹1.1 L
19 Jun 2026
29 May 2026
5 Jun 2026
17 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 56,86,010.1 | ||
| — | 2.00 | — | — | ||
| Supply of automatic changeover control and distribution panel of 150 Amp capacity as per RDSO specification No. TI/SPC/PSI/CLS/0025 or latest, suitable for operation with 25 kVA Auxiliary Transformer (AT), comprising of sheet steel cubicle type floor/wall mounted enclosure with powder coated finish, degree of protection as per specification, complete with incoming and outgoing MCCBs/MCBs, automatic changeover arrangement with electrically and mechanically interlocked contactors, control relays, timer relays, under/over voltage protection, phase failure protection, indicating lamps for all phases and supply status, ammeter, voltmeter with selector switch, energy meter (if required), push buttons, selector switches, control wiring with ferrules, terminal blocks, cable glands, earthing bus bar, space heaters, ventilation arrangement, danger and instruction plates, name plates, internal wiring, hardware, fasteners and all other accessories, including factory testing, inspection, packing, forwarding, supply at site, and guarantee/warranty, complete in all respects and ready for installation and operation. | — | — | — | 3,89,256.76 | |
| — | 2.00 | — | — | ||
| Erection, fixing, testing and commissioning of automatic changeover control and distribution panel of 150 Amp capacity as per RDSO specification No. TI/SPC/PSI/CLS/0025 or latest, suitable for operation with 25 kVA Auxiliary Transformer (AT), including shifting to site, positioning, leveling and anchoring on foundation/frame, interconnection with incoming and outgoing power cables, termination with proper lugs and glands, earthing connection, checking of wiring, calibration of relays and meters, functional testing of automatic changeover operation under simulated supply conditions, trial run, rectification if any, and handing over in healthy working condition, complete in all respects. | — | — | — | 9,253.34 | |
| — | 7.00 | — | — | ||
| Shifting of existing CLS panel to new EI building/Location Hut by dismantling, re- installation, re-termination of cables and testing & commissioning for satisfactory operation, complete in all respects, including providing and connecting required cables as per field supervisor. | — | — | — | 73,500 | |
| — | 2.00 | — | — | ||
| Supply, fitting and fixing of on-load changeover switch of 4 pole, 100 Amp capacity, suitable for 3 phase, 4 wire, 415 V, 50 Hz AC system, conforming to IS/IEC 60947, housed in robust sheet steel enclosure with powder coated finish and minimum IP-42 protection, complete with terminals, neutral link, earthing provision, mechanical interlocking arrangement, and clear ON-OFF- ON position indication, along with labeling, mounting accessories and all necessary hardware for safe and reliable manual changeover operation, complete in all respects. | — | — | — | 30,300 | |
| — | 3500.00 | — | — | ||
| Supply, laying and testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 185 mm.sq. 2 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988 . For laying of cable Excavation of earth depth 0.75 Mtrs. into breadth 0.5 Mtrs. below the ground level and a layer of sand of 0.075 Mtrs. thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of sand of 0.075 Mtrs. thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. The Cable is from Transformer to Panel. | — | — | — | 36,75,000 | |
| — | 800.00 | — | — | ||
| Supply, laying and testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 70 mm.sq. 2 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. . For laying of above cable by digging of trench and excavation of earth to depth 0.75 Mtrs. and breadth 0.5 Mtrs. below the ground level and a layer of sand of 0.075 Mtrs. thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of sand of 0.075 Mtrs. thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. The cable route markers should be provided along the route of cables to indicate their presence so that damage/accident are Not caused by inadvertent digging. Cable To be drawn by , Suitable GI clamps through Structure/Wall /Cable Tray /GI pipe for Sub- power supply of building as per direction of Engineer Incharge at site. | — | — | — | 3,77,600 | |
| — | 2600.00 | — | — | ||
| Supplying and laying of size 120 mm dia (OD-120 mm & ID-103 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. | — | — | — | 9,56,800 | |
| — | 7.00 | — | — | ||
| Supply, fitting, fixing of thermoplastic cable junction box IP/65 protection with metric knockouts for cable entry suitable for cable size 70/185 SQ mm with 4 nos of terminals. Junction box size(300x450x 170)mm (LxBxH) with OEM fitted Terminals. The junction box to be suitably fixed on wall of washing pit with suitable sixe MS clamp , nuts amd bolts etc. as per direction of supervisor incharge at site | — | — | — | 1,74,300 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
AnexxuresSectionVIINew.pdf
ATTACHMENT
TenderDocument926-R.pdf
ATTACHMENT
GCCACS11_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .