Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.5 LAccepted-AOC LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹33.0 L+₹35,325.50 (1.08%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹36.7 L+₹4.1 L (12.4%)Rejected-Finance H NO 283 PHASE 3 KRISHNAPURAM MISROD HOSHANGABAD ROAD BHOPAL MP PIN 462046 | BHOPAL | BHOPAL | MADHYA PRADESH | 462046 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹39.9 L+₹7.3 L (22.3%)Rejected-Finance 84 A VIJAY NAGAR COLONY LALGHATI PO NAYAPURA BHOPAL 462032 | 462032 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹40.9 L+₹8.2 L (25.3%)Rejected-Finance CIVIL LINE MATATILA ROAD TALBEHAT DISTT LALITPUR U P | TALBEHAT | LALITPUR | U P | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹50.0 L
EMD Value
₹99,980
Closing Date
26 Dec 2023, 6:00 pmClosed
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
REPAIR MAINT OF HIGH MAST LIGHT STREET LIGHTS TIMER PANEL LT CABLE POLE BOXES ETC AND REPAIR MAINT OF LT PANELS LT CABLES OH LINES AND ALLIED WORKS AT SI LINES AND REPAIR MAINT OF PERIMETER LIGHTS AND ALLIED WORKS UNDER GE BHOPAL
2023_MES_623328_2
8220/E8
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
BHOPAL
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE BHOPAL
₹99,980
Yes
15 Mar 2024
1 Dec 2023
28 Dec 2023
1 Dec 2023
26 Dec 2023
14 Dec 2023
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
Labour only for attending day to day complaints for repairing of street light, security light, post top lantern of any size/ wattage including tighting loose electric connection, carbon deposition and any other minor defects required for its smooth functioning at Bairagarh Military Station by deputing skilled and qualified electrician alongwith helper at any time of the day as per site requirement complete all as specified and directed. Note:- (i) It is compulsary to to attend maximum five nos complaints in a day within 24 hrs after intimation or receiving reciept of complain slip by JE/ AGE otherwise penalty of Rs 250.00 per day for non-attending the complaints will be levied on contractor. (ii) Complaints will be reported on daily basis with complaint register. (iii) Other minor items such as insulating tape, screws, small pieces of electrical cables PVC insulated copper multistranded conductor of size 2.5 Sqmm three core upto length of 1.5 m etc as required to attend the complaint is included in quoted rates. (iv) Any major items required for replacement will be paid seterately under respective item of Schedule 'A'.
S&F of integral LED Street light luminaire of not less than 45 W, luman efficacy not less than 110 lm per watt, comprising of die cast alluminium housing, enclosed with glass cover in frame, IP-66 protection suitable for voltage range should be 170 to 240 Volts with glass cover and with all fixing arrangement, nuts, bolts and washer connecting to electric system with 2.5 sqmm PVC aluminium stranded conductor 2 core minimum 2.0 m length, on pole including testing complete all as specified and directed.
S&F of integral LED Street light luminaire of not less than 60 W, luman efficacy not less than 125 lm per watt, comprising of die cast alluminium housing, enclosed with glass cover in frame, IP-66 protection suitable for voltage range should be 170 to 240 Volts with glass cover and with all fixing arrangement, nuts, bolts and washer connecting to electric system with 2.5 sqmm PVC aluminium stranded conductor 2 core minimum 2.0 m length, on pole including testing complete all as specified and directed.
S&F of integral LED Street light luminaire of not less than 70 W, luman efficacy not less than 125 lm per watt, comprising of die cast alluminium housing, enclosed with glass cover in frame, IP-66 protection suitable for voltage range should be 170 to 240 Volts with glass cover and with all fixing arrangement, nuts, bolts and washer connecting to electric system with 2.5 sqmm PVC aluminium stranded conductor 2 core minimum 2.0 m length, on pole including testing complete all as specified and directed.
S&F of integral LED Street light luminaire of not less than 90 W, luman afficacy not less than 125 lm per watt, comprising of die cast alluminium housing, enclosed with glass cover in frame, IP-66 protection suitable for voltage range should be 170 to 240 Volts with glass cover and with all fixing arrangement, nuts, bolts and washer connecting to electric system with 2.5 sqmm PVC aluminium stranded conductor 2 core minimum 2.0 m length, on pole including testing complete all as specified and directed.
S&F of integral LED flood light luminaire of 100 W, high efficiency as per IS-16107, IP-66 degree of protection with pressure diecast alluminium housing and toughened glass and with all fixing arrangement, nuts, bolts, washer and clamps for fixing and connecting to electric system with 2.5 sqmm PVC aluminium stranded conductor 2 core minimum 2.0 m length, on pole inclduing testing complete all as specified and directed.
S&F of integral LED flood light luminaire of 120 W, high efficiency as per IS-16107, IP-66 degree of protection with pressure diecast alluminium housing and toughened glass and with all fixing arrangement, nuts, bolts, washer and clamps for fixing and connecting to electric system with 2.5 sqmm PVC aluminium stranded conductor 2 core minimum 2.0 m length, on pole inclduing testing complete all as specified and directed.
S&F of integral LED flood light luminaire of 150 W, high efficiency as per IS-16107, IP-66 degree of protection with pressure diecast alluminium housing and toughened glass and with all fixing arrangement, nuts, bolts, washer and clamps for fixing and connecting to electric system with 2.5 sqmm PVC aluminium stranded conductor 2 core minimum 2.0 m length, on pole inclduing testing complete all as specified and directed.
S&F of integral LED flood light luminaire of 200 W, high efficiency as per IS-16107, IP-66 degree of protection with pressure diecast alluminium housing and toughened glass and with all fixing arrangement, nuts, bolts, washer and clamps for fixing and connecting to electric system with 2.5 sqmm PVC aluminium stranded conductor 2 core minimum 2.0 m length, on pole inclduing testing complete all as specified and directed. Notes for ser items Nos. 2.00 to 9.00:- Contractor will produced original manufacturer test certificate and warranty card for two years for all lighting luminaires.
S&F in replacement of polycarbonate thermoplastic weather proof junction boxes IP-65/66 for street lights size of approx size not less than 210 x 155 x 102 mm with metric knock outs for cable entry, weather proof for outdoor installation, glands and with 4 terminals, terminal rating 32 Amps for three phase and neutral mounted with locking arrangement including fixing to the poles by means of suitable size of clamps, nuts and bolts with and including 01 no SP, MCB, 6-32 Amps,10KA complete all as specified and directed.
S&F in repairs LED driver suitable for 45-60 Watt existing LED security/street lights of any make and model complete all as specified and directed.
S&F in repairs LED driver suitable for 70-90 Watt existing LED security/street lights of any make and model complete all as specified and directed.
S&F in repairs LED driver suitable for 100-200 Watts existing LED flood light of any make and model complete all as specified and directed.
S&F in replacement cable PVC insulated and PVC sheathed size 2.5 Sqmm three core stranded aluminium conductor complete all as specified and directed.
S&F in repairs bracket made of GI, light grade, pipe 1.2 mtr long of 32mm bore, bend to required shape as per site requirment and fixed to pole with flat iron 40x5 mm (02 Nos) clamps, bolts, nuts, washers including painting two coats of aluminium paint over a coat of primer complete all as specified and directed.
M&L for preparation of old painted surfaces of LT steel poles and applying a coat of aluminium paint on all steel surfaces such as channels, angles, etc; of any description and zebra marking on pole with black paint up to one meter height above PCC coping including pasting of radium reflector band / strips of 5 cm wide in green (02 Nos) and white (01 No) colour at a height of 1.25 mtr from coping of pole with and including writing the pole number in black colour on yellow background on the pole and a coat of cement base paint on PCC coping of poles complete all as specified and directed.
M&L for trimming of tree branches up to 2.0 meter clearance all around HT/LT overhead lines and depositing where directed at a distance not exceeding 50 mtr complete all as specified directed. Note: The item will be measured in span length of approx 30 mtrs between poles.
M&L for MCB, SP, 6 - 32 Amp, "C' curve, 240 V, 10 KA complete all as specified and directed.
S&F in repairs contactor, 25 Amp, triple phase, 415 V, as per IS-13947-4-1, suitable for nature time switch model swadeep -02 complete all as specified and directed.
S&F in repairs contactor, 16 Amp, single phase, 240 V, as per IS-13947-4-1, suitable for nature time switch model swadeep -02 complete all as specified and directed.
S&F in repairs sensor for automatic street light control panel, single phase as per existing make on ground including testing for automatic functioning of street light on timer complete all as specified and directed.
S&F in repairs sensor for automatic street light control panel, three phase as per existing make on ground including testing for automatic functioning of street light on timer complete all as specified and directed.
Dismantling of old unserviceable LT, PCC pole including necessary excavation, earth work etc. complete all as specified and directed.
M&L for replacement of steel tubular swaged poles with steel base plate 300x300x6mm, final taper plug, bolts, nuts and screws as specified type 410 SP-31, 9.0 mtr long including excavation, earth work etc including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30 cm wide circular bands with black & white paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in white paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
M&L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in coping to new/existing PCC/steel poles, earthing pits and similar work incluidng necessary formwork complete all as specified and directed.
M&L for PCC 1:4:8, type D-2 (using 20mm graded stone aggregates) as in foundation, filling in and mass concrete for foundation bed concrete in stays /poles or similar work complete all as specified and directed.
Taking out old unserviceable cable from trenches of any size complete all as specified and directed. Note: Excavation, earthwork required for taking out cable from trenches will be measured and paid seperately.
Supplying, laying, commissioning and testing of under ground LT cable, XLPE insulated screened PVC bedded, galvanized steel strip armored, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 core complete all as specified and directed.
Supplying, laying, commissioning and testing of under ground LT cable, XLPE insulated screened PVC bedded, galvanized steel strip armored, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core complete all as specified and directed.
Supplying, laying, commissioning and testing of under ground LT cable, XLPE insulated screened PVC bedded, galvanized steel strip armored, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 4 core complete all as specified and directed.
Supplying, laying, commissioning and testing of under ground LT cable, XLPE insulated screened PVC bedded, galvanized steel strip armored, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 4 core complete all as specified and directed.
Supplying, laying, commissioning and testing of UG LT cable XLPE insulated screened PVC bedded, galvanized steel strip armored, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 4 core complete all as specified and directed.
Supplying, laying, commissioning and testing of UG LT cable XLPE insulated screened PVC bedded, galvanized steel strip armored, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 2 core complete all as specified and directed.
Excavation in trenches in hard dense soil not exceeding 1.5 mtr wide and n.exe 1.5 mtr depth including getting out complete all as specified and directed.
Excavation in trenches in hard/dense soil exceeding 1.5 mtr wide and n.exc 3 mtr depth including getting out complete all as specified and directed.
Excavation in trenches in soft disintegrated rock n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable pipe and getting out complete all as specified and directed.
Returning filling in including spreading, leveling, and well ramming, in layers not exceeding 25 cm each layer of any kind of soil complete all as specified and directed.
Removing surplus excavated material from site to a distance not exceeding 50 mtrs and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand filling in trenches with clean, dry sand, unwashed including gently pouring around ground cable complete all as specified and directed. Note: Punned thickness will be measured and paid.
M&L for cable cover, class LV, type-1 flat, size 250mmx150mmx40mm for cable protection laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed.
M&L for replacement of GI tubing 80 mm dia, light grade, with all fittings as required for passing through cables under the floor, along the wall or along to pole and fixed in position complete all as specified and directed.
M&L for replacement of GI tubing 50 mm dia, light grade, with all fittings as required for passing through cables under the floor, along the wall or along to pole and fixed in position complete all as specified and directed.
M&L for replacement of GI tubing 40 mm dia, light grade, with all fittings as required for passing through cables under the floor, along the wall or along to pole and fixed in position complete all as specified and directed.
S&F of integral LED Solar Street light consisting of solar photovoltaic module battery, battery management system, control electronics, LED driver, PIR sensor, inter connecting cables and pole mounting piece integrated into the luminaire as a single unit. The system must comprises of solar street light with IP-65 protection having a system wattage of 27-29 watt with not less than 4500 lumen output, high efficiency mono-crystalline solar panel, highly efficient MPPT based charge controller and 12.8 V, 30 lithium ferro phosphate battery LED lumen efficacy shall be aleast 175 Lm/W with suitable LED driver the luminaire shall be hosued in IK-08 impact reistance certified alluminium pressure die-cast housing with anticorrosive coating and must have a UV stabilized polycarbonate cover, the luminaire shall have a specially designed pole mounting piece that enabled lateral as well as post top mounting and installation at varying from 0 to 15 degrees for optional light distrinution . The fixture proposed must have passed LM 79 & LM 80 reports along with the sample from a certified NABL laboratory complete all as specified and directed. Make Phillips / Bajaj / Wipro.
M&L for steel wire rope for high mast lights as per site requirement complete all as specified and directed.
S&F in repairs 11 watts LED aviation light having die cast aluminium housing with red polycarbonate dome for better illumination, integral LED driver, IP 65 protection, operating voltage range 100-270 V AC to be mounted on highmast pole only, with all connected accessories complete all as specified and directed.
M&L for overhauling of not less than 16 meters height high mast lighting system by degreasing and cleaning of double drum winch, gear box, wire rope, clamps, bobbin arrangement, power tool motor, mechanical torque limiter, lowering the mast head assembly, degreasing and cleaning the pulley, docking arm etc and applying new grease / lubricating oil for all mechanical moving / rotating parts, checking all the electrical parts such as timer panel, all cable connections in control panel, motor, junction box, flood light fittings and aviation obstruction light fitting etc, rectifying the defects, renewing the defective components etc including testing for proper functioning complete all as specified and directed. Note: Replacement of flood light fittings, aviation obstruction light, control cable, steel wire rope, timer panel components and rewinding of motor if required at site will be measured and paid seperately under respective items of Schedule 'A'.
Dismantling and taking down solar light fitting of wattage 11 to 36 watt with solar panel assembly, solar battery assembly, light controller, fixture mounting bracket for checking its serviceablity including carrying minor repair work and painting pole with 2 coats of synthetic enamel paint complete all as specified and directed. Note: Any major items required for replacement will be paid seterately under respective item of Schedule 'A'.
S&F in repairs solar panel assembly complete with panel, light controller, MPPT charge controller, brackets etc; suitable for 11 to 36 Watt solar street light of existing make and making necessary electric connection complete all as specified and directed.
S&F in repairs solar light assembly suitable for 11 to 36 Watt solar street light as per existing make including making necessary electric connection and GI bracket as per site requirement complete all as specified and directed.
S&F in repairs solar light lithium ferro phosphate battery suitable for 11 to 36 Watt solar street light as per existing make including making necessary electric connection complete all as specified and directed.
S&F in replacement of cross arms, bracings, supports, clamps and back plate fabricated from structural sections including nuts, bolts, and washers, bending hot or cold, drilling holes for bolts of any size and painting with two coats of aluminum paint over one coat of red oxide primer including preparation complete all as specified and directed.
S&F in replacement of polymer pin type insulator GI washer and one GI nut for 1100 Volt grade complete all as specified and directed.
S&F in replacement of polymer disc insulator ball and socket type with tension clamp and accessories suitable for conductor single disc assy working pressure 1100 volts complete all as specified and directed.
S&F in repairs MCCB, 4 pole, 415 Volts, adjustable type, 160 Amps, 50Hz, 36KA complete all as specified and directed.
S&F in repairs MCCB, 4 pole, 415 Volts, adjustable type, 200 Amps, 50Hz, 36KA complete all as specified and as directed.
S&F in repairs MCCB, 4 pole, 415 Volts, adjustable type, 250 Amps, 50Hz, 36KA complete all as specified and as directed.
S&F in repairs MCCB, 4 pole, 415 Volts, adjustable type, 400 Amps, 50Hz, 36KA complete all as specified and as directed.
Supply & straining the ACSR conductor including binding wire, tape and jumper including taking out unservicable conductor complete all as specified and directed.
M&L for re-streching of loose over head ACSR conductor of any type/GI wire and repairong of broken conductors and adding additional conductor of required length (if required) in place of old and burnt conductor of any size on existing poles with proper sagging including winding with wire (old conductor shall be reused where required for repairing broken length of conductor) complete all as specified and directed. Note:- Five lines together will be measured as one span from pole to pole or approx 30 m.
S&F in replacement cable saperator heavy duty made of plastic with PVC clamps heavy duty three phase separator complete all as specified and directed.
S&F in replacement cable saperator heavy duty made of plastic with PVC clamps heavy duty two phase separator complete all as specified and directed.
S&F in repairs of cradles (hexagonal/rectangular) fabricated with galvanised steel wire of 4 mm dia complete all as specified and directed.
M&L for earthing complete with galvanised steel plate earth electrode 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earthing strip of dimension 32X6 mm by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including testing complete all as specified and as directed Note: Necessary excavation to be measured and paid seperately.
S&F for providing GI strip of 32x6 mm size and making proper arrangements for connection between earthing and transformer/ other equipment complete all as specified and directed.
S&F in repairs 1100 Volts grade heavy duty cable PVC insulated aluminum conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart with 4 mm steel suspension wire, one twin core cable flat or circular of size of aluminum conductor 6 sq mm stranded conductor complete all as specified and directed.
S&F in repairs 1100 Volts grade heavy duty cable PVC insulated aluminum conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart with 4 mm steel suspension wire, one twin core cable flat or circular of size of aluminum conductor 10 sq mm stranded conductor complete all as specified and directed.
Repairing of outdoor type LT panel board mounted on angle / PCC floor of any size with and including replacement of unserviceable switch/control gears, connector, indicator lamps, panel door lock and other minor repairs including rewiring and extension of incoming and out going cables (cable excluded) by opening of loops/making joints and providing cable lugs /thimbles as reqd including repairing rusted part of sheet metal door with existing size MS sheets by necessary arc/gas welding and removing all dirt, dust etc. with air blower and painting complete panel board with two coats of synthetic enamel spray painting over a coat of red oxide primer including writing identification works complete all as specified and directed, panel is comprising of the following items:- (a) MCCB 100 A to 400 A, 3/4 pole 415 Volt -04 to 06 Nos (b) Indicator Lamp RYB LED type with fuse.-01 set (c) Aluminium bus bar RYB & N of 200 A size -01 set (d) Amp / Volt Meter 02 Nos (e) MCB TPN/SPN/SP mounting on bus bar -01 to 6 Nos Note: (i) Cost of providing aluminium thimbles, earth and neutral link, insulator, hylem sheet, any type of screws or any other minor spares of any type as required at site is deemed to be included in the quoted rate. (ii) MCCB, MCB, aluminium bus bar, indicator lamp, Amp / Volt meter or any other major parts required for relacement shall be measured and paid serately in relevent item.
S&F in replacement LED type indicating Lamp for indication of RYB complete all as specified and directed.
S&F in replacement aluminium bus bar rating 200 Amps, 25/6 mm including making hole suitable for panel with tape insulation of suitable colour in phase RYB & neutral in black colour complete all as specified and directed.
M&L for preparation of old painted surface of F/P box / LT panel after taking out all incoming and out going cables and removing all dirt, dust etc with the help of air blower and painting complete panel board with two coats of synthetic enamel spray painting over a coat of red oxide primer including writing of identification mark and the re-connecting all cable with suitable lugs /thimbles as reqd with and including replacement of transparent PVC sheet with rubber gasket for window with existing size complete all as specified and directed Note: Cost of thimbles, PVC sheet and gasket, any type of screws and other minor parts are deemed to be included in the quoted rate.
M&L for preparation of old painted surfaces on iron gate, rolling shutter, change over switches and similar items and applying one coat of synthetic enamel paint complete all as specified and directed.
S&F in repairs mild steel work in framed work of required sections for repairing of gates, grills, framed guard bars, gratings, ladders, MS clamps etc; with ends of bars shouldered and/ or riveted, or forged into spikes complete all as specified and directed
M&L for precast cement concrete 1:2:4 type B-1 (using 20 mm graded aggregate) as in cover slab for earth pits etc; complete all as specified and directed. Note: Reinforcement shall be measured seperately.
S&F of mild steel TMT bars 6 to 8 mm dia bars, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
S&F in replacement of old unserviceable lugs after cutting the worn out /faulty cable end from LT pillar/panel box and making cable lead by providing aluminium lugs including crimping with crimping tools in the existing LT cable upto 50 Sqmm, 3.5 core upto including necessary connection complete all as specified and directed.
All as per item No 78.00 here-in-before but aluminium lugs for cable from 70 to 120 Sq mm.
Deduct Schedule of credit (calculation will be done off line) Rs. 114824.00
PRADEEP TIWARI CONTRACTOR
M/s logitech solution
POONAM ELECTRIC INDUSTRY
HARNAM SINGH ANIL SINGH
M/s AKG Engineers & Contractors
Raj Contruction
HRK ENGINEERING CORPORATION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .