Loading…
Loading…
Tender Value
₹6.6 L
EMD Value
₹13,950
Closing Date
3 Sept 2026, 11:00 am7d left
EXECUTIVE ENGINEER ELECTRIC NGZ
OFFICE OF THE EXECUTIVE ENGINEER ELECTRIC NGZ
Upgradation of Lighting arrangement and other allied assets in Dy. Commissioner Office and Visitor Lobby in Zonal Office Building Najafgarh under Najafgarh zone.EEE/NGZ/MCD/2026-27/24-05
2026_MCD_288980_5
EEE/NGZ/MCD/2026-2027/24
Open Tender
Electrical Works
Percentage
60 days
NAJAFGARH ZONE
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹13,950
26 Aug 2026
26 Aug 2026
3 Sept 2026
26 Aug 2026
3 Sept 2026
26 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient (temperature). 2.0 TR with 5 Star BEE Rating | - | Metre | 57,396 | - |
| 2 | S/I/T/C of 5 KVA Voltage Stabilizer having input voltage 150V-270V and output voltage 195-245V | - | Each | 3,992 | - |
| 3 | S/I/T/C of stand for split AC | - | Each | 788 | - |
| 4 | S/I/T/C of copper pipe for split AC | - | Per Meter | 838 | - |
| 5 | S/I/T/C of Drain Pipe | - | Per Meter | 106 | - |
| 6 | S/I/T/C of 3 Core, 4 Sqmm. Electrical wire for Air Conditioner | - | Per Meter | 158 | - |
| 7 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. | - | Each | 1,806 | - |
| 8 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group A | - | Each | 1,704 | - |
| 9 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | - | Metre | 311 | - |
| 9.1 | b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire | - | Metre | 373 | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.24 MB
DNIT2405.pdf
Tender Documents • 6.97 MB
MakeCondCircular.pdf
Other Document • 10.69 MB
GCC.pdf
Other Document • 1.97 MB
BOQ_337080.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].