Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.5 LAccepted-AOC 28 GREEN PARK PO BELGHARIA KOLKATA WEST BENGAL 700 056 | 24 PARAGANAS NORTH | WEST BENGAL | 700056 | L1 | Accepted-AOC Being Lowest bidder | |
| 2 | L2₹46.7 L+₹2.3 L (5.06%)Rejected-Finance | L2 | Rejected-Finance Being Higher Bid Value | |
| 3 | L3₹47.9 L+₹3.5 L (7.76%)Rejected-Finance 1 1 MEREDITH STREET KOLKATA 700072 INDIA | KOLKATA | WEST BENGAL | 700072 | L3 | Rejected-Finance Being Higher Bid Value | |
| 4 | L4₹48.0 L+₹3.5 L (7.93%)Rejected-Finance | L4 | Rejected-Finance Being Higher Bid Value | |
| 5 | L5₹48.7 L+₹4.2 L (9.54%)Rejected-Finance 28 H TOLLYGUNGE CIRCULAR ROAD KOLKATA 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L5 | Rejected-Finance Being Higher Bid Value |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
1 May 2025, 11:00 amClosed
GARRISON ENGINEER
GE I R and D Chandipur Post Chandipur PIN 756025
REPAIRS TO ROOF TREATMENT SUNKEN FLOORS TREATMENT AC SHEETS FLOORING TILING AND CERTAIN ALLIED WORKS AT BALASORE AND NILGIRI AND REPAIRS TO DBS MCBSSUB MAIN AND POINT WIRINGSUMMER APPLIANCESEARTHING
2025_MES_703489_1
8137/A/E8
Open Tender
Civil Works
Item Rate
180 days
GE I R AND D CHANDIPUR
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE I R AND D Chandipur
₹90,000
Yes
9 Jul 2025
3 Apr 2025
2 May 2025
3 Apr 2025
1 May 2025
17 Apr 2025
Amount
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises.
M&L rendering 10 mm thick cement plaster in CM (1:4) on fair faces of brick work for fixing of wall tiling complete all as specified and directed.
M&L for 15 mm thick screed bed or bedding layer of mortar in CM (1:6) for laying floor finishes for non skid ceramic and grinaite tiles complete all as specified and directed.
M&L Glazed ceramic coloured tiles 450X 300X 7mm thick set coloured tiles as in dado, skirting and vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles complete all as specified and directed.
M&L Non Skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exc 0.11 sqm in floors etc set & jointed in neat cement slurry and pointed in coloured cement complete all as specified and directed.
M&L Non Skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exc 0.18 sqm in floors etc set & jointed in neat cement slurry and pointed in coloured cement complete all as specified and directed.
Ditto all as per item 6 but in skirting complete all as specified and directed.
M&L for vertified ceramic tiles 8 to 9 mm thick light shade (Square/ rectangular) polished area of each tiles not exceeding 0.36 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified.
Ditto all as per item 8 but in skirting complete all as specified and directed.
S&F fixed in repairs Grating doom 125 mm dia size of PTMT (minimum weight 40gms) complete all as specified and directed.
S&F PVC connection of 15mm size with PTMT nuts of length 600mm long complete all as specified and as directed.
S&F in repairs 10 Liters capacity, low level flusing cistern, PVC, white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia including brackets and connections to pipe complete all as specified and as directed.
S&F in repairs wash down water closet (EWC) complete white with plastic water closet seat black closed pattern with flat bottom anc cover and mild steel chromium plated or aluminised hinging device and flush pipe of polythelene of low or density or PVC 32mm dia for low level flushing cistern complete all as specified and directed.
S&F in repairs Vitreous china Squatting pan Orissa pattern of size 580mx440mm white with integral foot rests (excluding flushing cistern and flush pipe) complete including concrete bedding complete all as specified and directed.
S&F vitreous china wash basin, white, flat back size 550x400mm, incl cutting for and pinning in ends of brackets or erecting stand but excl taps, pvc conections but incl brackets, waste pipe, waste coupling in repairs
S&F in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls including necessary brackets clamps or laid in trenches complete all as specified and as directed.
S&F in repairs 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls including necessary brackets clamps or laid in trenches complete all as specified and as directed.
S&F in repair 75mm bore PVC (SWR) junction single (Single "T") equal or unequal with access door complete all as specified and as directed.
All as per item No 18 above but 110mm complete all as specified and as directed.
S&F in repairs 75mm bore PVC (SWR) bends of any radius complete all as specified and as directed.
All as per item No 20 above but 110mm complete all as specified and as directed.
Taking down of steel tubing 15mm dia of pipe and connections complete all as specified.
All as per item No 22 above but 20 mm complete all as specified and as directed.
Supplying and laying of 20 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified
All as per item No 24 above but 25mm outer dia complete all as specified and as directed.
Cutting chases, pinning in. making good to facings where required & pointing in cement mortar CM (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing etc., and making good, cutting not exc 15 cm girth complete all as specified and as directed.
S&F in repair 15mm dia fancy type CP bib taps, cast copper alloy with crutch or butterfly handle, screwed down fixed in repairs.
S&F in repairs 15mm dia fancy type CP pillar taps, cast copper alloy with capstan head, chromium plated screwed down fixed high pressure, long screwed shanks and fly nuts, screwed for iron pipe in repairs.
S&F in repairs 15 mm dia CP concealed type stop valves/ angular stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or unions in repairs.
Dismantling timber scantlings 40 sq. cm and over in section, in any position
Taking down asbestos cement corrugated or semi corrugated sheet in roof covering complete all as specified and directed
S&F for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240
M&L for applying two coat of synthetic enamel paint on new steel surface over a coat of red oxide incl preparation of surface of any description over 10 cm width or girth.
M&L 0.50 mm thick pre painted galvalume aluminium zinc coating GI based corrugated steel sheet of any colour as in roof covering with self tapping screws as specified.
M&L 0.50 mm thick pre painted galvalume aluminium zinc coating GI based Plain steel sheet of any colour as in roof covering with self tapping screws as specified.
Taking out existing roof treatment and taking out existing plaster and wire brushing and cleaning the existing surface with water etc and removing rubbish to a distance not exceeding 1.50 Km all as specified and as directed..
M&L for 25mm thick PCC (1:2:4), type B-0, (using 12.5mm graded stone aggregate) complete all as specified.
M&L for 3mm thick APP modified non-woven polyester reinforced bituminous membrane with mineral slate granules and flexible at -2 °C (Sika shield P 24 MG or equivalent) water proofing membrane weight not less than 3 Kg/sqm including one coat of bituminous primer for bitumen membrane @ 0.4 lit/sqm over plaster surface. Over the primer coat the membrane shall be laid using butane torch and sealing all the joints etc complete all as specified and directed. Note : The laying of membrane shall be got done through the authorised applicator of the manufacturer.
M&L for rendering 15 mm thick on brick work or concrete surfaces in cement mortar (1:4) finished surfaces even and smooth with WPC complete all as specified and as directed. (Note : WPC shall be measured and paid separately)
M & L for removing the plant from walls & roof of the building with complete roots, applying recommended chemicals to prevent further growth as directed, making good the disturbed surface with PCC 1:2:4 and CM 1:3 and applying surface finishs to match the existing surface including removal of debris etc outside the premises complete all as rqd and specified.
Demolition of brick work built in cement mortar incl quoin, arches etc complete all as specified and directed.
M&L for brick work with flyash bricks old size, straight or curved on plan exc 6 m mean radius built in cement mortar CM (1:6) etc complete all as specified & directed.
All as per item No. 42 but except bricks (bricks obtained from item No - 41)
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
M&L rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar CM (1:6) and finished even and smooth without using extra cement complete all as specified.
M&L for 5 mm thick cement plaster in cement mortar CM (1:3) of ceiling, finished even and smooth with out using extra cement complete all as directed.
M&L for rendering 15 mm thick on brick work or concrete surfaces in cement mortar CM (1:4) finished surfaces even and smooth complete all as specified and as directed.
M&L three coats of white wash on newly plastered surfaces of ceiling including preparation of surfaces complete all as specified and as directed.
M&L for preparation of new plastered surfaces of walls applying 1mm thick wall care putty to achieve smooth surface rubbing with sand paper and applying two coats of acrylic distemper over a coat of alkali-resiatant primer complete all as specified and directed.
M&L for Finishing walls with Acrylic Smooth exterior coat paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Demolition of cement concrete of any description and in any position not otherwise specifically provided for and removing rubbish to a distance not exceeding 1.50 Km complete all as specified and as directed.
M&L for rendering 10mm thick in cement mortar CM (1:4) on internal wall brick / concrete surfaces, finished even and smooth without using extra cement
M & L for applying evenly a priming/tack coat with bituminous primer at 10 Kg per 10 Sq.m complete all as specified.
M&L for Sand filling under sunken floors or in foundations including watering and consolidation all as specified and directed.
M&L for PCC (1:5:10) type E-2, using 40mm graded aggregate as in filling in Sunken floor complete all as specified and as directed.
M&L for 30mm thick PCC (1:2:4), type B-0, using 12.5mm graded aggregate as in sunken floor flooring complete all as specified and as directed.
Supply only integral water proofing compound (ISI marked) of approved make.
Disconnecting existing 500 or 1000 ltr tanks, setting aside (or lowering if required) for repairs and sifting to other place incl all required dammaged part of tanks, cleaning, etc. and hoisting if required reconnecting and re-fixing in position.
Demolition of unserviceable RCC over head tank (reinforcement cut as required to facilitate demolition) concrete of any description and in any position not otherwise specifically provided and remove the debris from the site complete all as specified and directed.
M&L 75 mm thick Cement concrete type C-1, (1:3:6) (using 20mm graded aggregate) with water proofing compound for PVC water tanks complete all as specified and directed.
Dismantling water tanks of capacity exc 250 and n. exc 500 ltrs capacity.
S&F 500 litre capacity rotational moulded polythylene tripple layer water storage tank with cover and suitable locking arrangement (cylindrical vertical with closed top) hoisted and fixed in position all as per specified in SSR part-I.
S&F PVC ball valves high pressure with polythene float and fly nut complete, screwed for iron pipe of 20mm bore all as directed.
S&F in repair 20 mm CPVC Ball Valve (Gate Valve) all as per specified and directed.
S&F in repair 25 mm CPVC Ball Valve all as per specified and directed.
S&F MCB DB made of sheet steel phosphatised, powder painted double door with bus bar, neutral link, earth bar and din rail of SPN 4 way, 240 Volts fixed in wall,making good disturbed surfaces, including taking out old DB with fittings & fixtures complete all as specified. OTES: MCBs shall be measured and paid in revelant items.
S&F MCB DB made of sheet steel phosphatised, powder painted double door with bus bar, neutral link, earth bar and din rail of SPN 8 way, 240 Volts fixed in wall,making good disturbed surfaces, including taking out old DB with fittings & fixtures complete all as specified. NOTES: MCBs shall be measured and paid in revelant items.
S&F MCB DB made of sheet steel phosphatised, powder painted double door with bus bar, neutral link, earth bar and din rail of SPN 12 way, 240 Volts fixed in wall,making good disturbed surfaces, including taking out old DB with fittings & fixtures complete all as specified. NOTES: MCBs shall be measured and paid in revelant items.
S&F MCB DB TPN 4 way having degree of protection as per IP 42 or above with metal door (double door) 415 Volts complete copper bus bar with neutral link with provision for MCB TPN as incomer and MCB SPN MCBs as outgoing with blanking plates, required size cable lugs etc fixed in wall,making good disturbed surfaces, including taking out old DB with fittings & fixtures complete all as specified.all as directed by Engr-in-Charge NOTES: MCBs shall be measured and paid in revelant items.
Taking down Sub main /Sub circuit wiring of any type and size including conduit / casing capping / batten wiring complete all as directed.
M&L for Circuit/Submain wiring using three runs of FRLSH grade PVC insulated unsheathed, multistranded, copper conductor cable of size 6 Sqmm to be drawn in and including PVC concealed conduit 25 mm dia (medium grade). Note: Three runs of 6 Sqmm copper wire and one run of conduit pipe shall be measured as one unit.
All as per Sl Item No 71 above but in PVC casing caping (medium duty) of size not less than 20 mm width
M&L for Submain/Sub circuit wiring using three runs of FRLSH grade PVC insulated unsheathed, multistranded, copper conductor cable of size 4 Sqmm to be drawn in and including PVC concealed conduit 25 mm dia (medium grade). Note: Three runs of 4 Sqmm copper wire and one run of conduit pipe shall be measured as one unit.
All as per Sl Item No 73 above but in PVC casing caping (medium duty) of size not less than 20 mm width
Taking down carefully copper /aluminium point wiring (light, fan ,socket or power) complete, including fixture and fittings such as switches, ceiling rose, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia concealed in wall/ceiling, etc. and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one light / fan point controlled by one 5/6 amps, one way switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
- Ditto - all as per item No. 76 mentioned here in above but for one light point controlled by two way switches.ditto complete all as specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC casing caping (medium duty) of size not less than 20 mm width and accessories, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one light / fan point controlled by one 5/6 amps, one way switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
.-Ditto-All as per item No. 78 above but for 5 Amps independent switch point wiring with 2 x 1.5 mm2 copper conductor cable and 1.5 mm2 copper conductor cable as earth continuity conductor.
- Ditto- all as per item No. 79 above but on same board for 5 Amps switch point wiring with 2 x 1.5 mm2 copper conductor cable and 1.5 mm2 copper conductor cable as earth continuity conductor.
- Ditto - all as per item No. 80 above but for 5 /15 Amps independent switch point wiring with 2 x 4 mm2 copper conductor cable and 4.0 mm2 copper conductor cable as earth continuity conductor.
S&F as inreplacement Switch piano, flush type, single pole, one way 5 Amps, 240V complete all as directed by Engineer-in-Charge. Make:- Anchor/Cona/Havells
S&F as inreplacement Switch piano, flush type, single pole, one way 15 Amps, 240V complete all as directed by Engineer-in-Charge. Make:- Anchor/Cona/Havells
M&L as inreplacement socket outlet 2 in 1, 3 pin, 5 amp flush type controlled by one switch.
M&L as inreplacement socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type controlled by one switch.
M&L as in replacement for switch piano, flush type single pole, two way 5 Amps including connection.
S&F as inreplacement including connection of modular switch one way 6 Amps 1 Module complete all as specified and directed.
S&F as inreplacement including connection of modular switch one way 16 Amps 1 Module complete all as specified and directed.
S&F as in replacement including connection modular socket outlet 2 /3 pin 6 Amps 2 modules complete all as specified and directed.
S&F as in replacement including connection modular socket outlet 2 /3 pin 6/16 Amps 2 modules complete all as specified and directed.
S&F as in replacement including connection modular Fan step regulator, 120W - 2 module complete all as specified and directed.
S&F as in replacement white modular cover plate with frame 6 Module complete all as specified and directed.
S&F as in replacement white modular cover plate with frame 8 Module complete all as specified and directed.
S&F as inreplacement of call bell Dingdong, 230 V AC, single pole
S&F as inreplacement bell push, flush type , 5 Amp
M & L as in replacement ceiling rose PVC poly carbonate, isolated body with three terminals including connection.
M & L as in replacement stepped type electronic fan requlator flush type 230/240 volts complete all as specified
M&L as in replacement lamp holder angular type PVC / Polycarbonate type insulated body with back plate suitable.
S&F in replacement MCCB 4 pole, with fixed thermal & magnetic release of breaking capacity 16 kA, 415 Volts, 63 Amps including necessary lugs,wiring etc.
S&F in replacement MCCB 4 pole, with fixed thermal & magnetic release of breaking capacity 16 kA, 415 Volts, 100 Amps including necessary lugs,wiring etc.
S&F in replacement RCCB 4 pole, of breaking capacity 10 kA, 415 Volts, 63 Amps including necessary lugs,wiring etc.
S&F in replacement Supply and fixing 415V 10KA,four pole MCB 'C' series 80 to 100 AMP current carrying capacity in the DB complete with connection testing and commissioning.
S&F in replacement MCB, SPN. 40-63 Amps rating 240, volt, 'C' series, 10 kA
S&F in replacement MCB, SP, 6-32 Amps, 240 volt, 'C' Series, 10 kA
S&F in replacement Highly robust batten suitable to use with T8 LED Tube type, indoor decorative type luminaire complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed.
S&F in replacement LED T8 Tube with in built driver in pc housing double sided connection of capacity 20 watts all as specified and directed,
S&F in replacement High-quality design LED batten light in extruded aluminium housing with high quality PC diffuser 20 watt with enhances safety and relible ,robust housing structure with decorative end caps complete with all accessories including LED tubelight internally pre-wired with capacity of 100 lumen/watt complete all as specified and directed.
S&F in repair LED Bldg security light fitting 45 Watt with all accessories, LED street light with pressure die-cast housing, high performance polycarbonate optics and IP66 ingress protection. Top opening driver cover for easy maintenance. Efficiency 120 lm/W.,for mounting bracket of 40mm bore GI pipe light grade complete with all accessories including taking down old fitting as directed.
Supply & Fixing of GI pipe bracket of 40 mm dia grade pipe bend to shape of approx length 1.5 mtr including 2 no MS clamp of flat iron size 40×6 mm complete with nut bolt washer all as specified and directed .
Materials and labour for earthing as in repair complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 25 x 4mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed by the Engr-in-Charge.
Material and labour in replacement for Galvanised iron strip 25 x 4 mm burried in ground complete all as specified and directed by the Engineer-in-Charge.
Supply and laying as in replacement 40mm bore GI pipe "light grade" with all fittings and fixed to walls, floor etc complete all as specified and as directed by the Engr-in-Charge.
Cleaning, servicing including carrying out preventive maintenance of summer appliances viz. indoor and out door unit of Split Air conditioners and complete unit of Window Type ACs of following capacities using suitable cleaning solution, chemicals, tools and minor spares viz. screws, washers, insulation tapes, thimbles, PVC fasteners etc. as per site requirement and as directed. Cleaning of the condensor, evaporator, fins and cooling coils shall be done using Blower / Vacuum cleaner, cleaning clothes, nylon brushes etc till scales and dirts are removed including cleaning of drain pipe line and replacement of unserviceable spares if any and ensuring its serviceability by keeping the AC in good working condition all as specified and directed by Engineer-in-Charge. Note :- 1. During servicing work, if any major fault is observed, the machine will be repaired under respective item of the schedule under Supply and fix in repair work, and thereafter servicing will be undertaken and completed. 2. Spares required for repair of unserviceable machines if any will be measured and paid under respective item of this schedule as "Supplied only" items. However, for servicing work, cost of minor spares to be replaced if any and not specified in this schedule viz. screws, washers, teflon seal, rubber bush, insulation tape, copper thimble, copper connecting jack, short length connecting wire, markers etc upto Rs 100 is deem to be included in the rate of the item. 3. Cost of taking down, reinstallation and transportation if required for the servicing / repair work is deem to be included in the price. 4. Servicing and repair work will be carried out within the contract period as and when required as per the site requirement and as directed by Engg-in-Charge.
(a) Split Type AC 1.5 TR Capacity
(b) Window type AC 1.5/2 TR Capacity
All as per item 113 above but for water cooler / refrigerator of any type, size and capacity as described below. The inner water tank of water cooler should be cleaned using bleaching powder and keeping the inner tank clean from bacteria and formation of scales and ensuring its serviceability all as specified and as directed by Engineer-in-Charge.
Supply only thermostat for water cooler of any capacity and existing make.
Supply only relay for any type of water cooler of any capacity and existing make.
Supply only PCB suitable for split type A/C 1.5 TR capacity of and existing make.
Repair of old PCB fitted in existing split type A/C 1.5 TR capacity of any make/ model, opening up for inspection/checking and make sure the serviceability of incoming/outgoing connections etc and reassembling the same with dismantled component after replacement of burnt spare parts and internal wiring complete all as directed and specified by Engineer-in-Charge.
Supply only Digital Display Unit suitable for split / window type A/C 1.5/ 2 TR capacity of existing make.
Supply only Air sensor suitable for split / window type A/C 1.5/2.0 TR capacity of existing make.
Supply only Coil sensor suitable for window / split type A/C1.5/ 2 TR capacity of existing make.
Supply only Running capacitor 45/45+6 mfd for Window / Split type Air conditioner of of any capacity of existing make.
Supply only Running Capacitor capacitor 50/50+5 mfd for Air conditioner 2 Ton Capacity
Supply only capacitor of 6 mfd capacity suitable for all split / wiondow type AC Blower Fan of existing make and model .
Supply only capacitor of 8 mfd capacity suitable for all split / wiondow type AC Blower Fan of existing make and model.
Supply only auto swing motor for indoor unit of split A/C of capacity 2/1.5 TR of any make and model to match with existing design conditions.
Supply only Thermostat for Window AC of capacity 1.5 TR/2.0 TR to match with existing design conditions.
Supply only blower drum suitable for Split/Window type AC of any capacity and to match with existing design conditions..
Supply only PVC Drain pipe of size 1/2" size suitable for Split type AC of existing capacity.
Supply only , main Drain pipe of indoor unit of size 3/4 ", PVC Flexible type suitable for Split type AC of any capacity.
Supply only Rubber Bush for Fan Motor of out door unit of split type AC and Window type AC of existing capacity and any make and model .
M&L for Gas charging with R-22 refrigerant gas for Split / Windows ACs of any make, model and capacity, Refrigerator and Water coolers of any make, Model of any capacity in position or by taking down including leak testing to achieve desired suction pressure and temperature and all as directed by Engg-in-Charge. Note: Leakage or loss of gas due to imperfect workmanship will not be measured. Only the qty of gas utilised as per design of machine will be measured after successful gas charging.
M&L for Gas charging with R-407/R-410/R-410A/R32 refrigerant gas for Split / Windows ACs of any make, model and capacity, Refrigerator and Water coolers of any make, Model of any capacity in position or by taking down including leak testing to achieve desired suction pressure and temperature and all as directed by Engg-in-Charge. Note: Leakage or loss of gas due to imperfect workmanship will not be measured. Only the qty of gas utilised as per design of machine will be measured after successful gas charging.
Supply and fixing in repair, Out door Bracket ISI marked suitable for fixing out door unit of Split type ACs of any make and capacity along with MS clamps, bracings, supports, bolts, nuts & washers, PVC rawl plug etc and making good disturbed surface of wall in CM 1:3 including painting to match with existing surface and all as directed.
M/L for carrying out spray painting complete unit of window type AC of any make, model and capacity after dismantling, and painting on sheet metal enclosers interanally and externally with two coats of synthetic enamel paint of approved make and shade after preparation of surface and writing the MES/SM Nos, re-assembling and reconnecting the AC unit at its installed location complete all as directed.
All as per item 138 above but for outdoor unit of split AC of any capacity make and model.
Repair of voltage stabilizer of any capacity ( 1 to 5 KVA) and make, opening up for inspection/checking serviceability of voltage regulating transformer relays, circuit board, voltmeters, incoming/outgoing connections etc and reassembling the same with dismantled component after replacement of burnt spare parts and internal wiring complete all as directed and specified by Engineer-in-Charge. Note. Replacement of spare parts shall be measured and paid separately under items below :-
Supply only transformer relay of any capacity between 4 to 5 KVA including taking down.
Supply only square/ round type voltmeter of size 2" x 2" for various voltage stabilizers
Supply only transformer relay for various capacity of stabilizers
Supply only circuit board for various capacity of stabilizer
Supply only 3 way connector for voltage stabilizer
Supply & Fix in replacement polythylene soft thermocol of size 180x90x4 cm for window type AC side packing during AC installation
Taking down of RO water purifier (Kent/aquaguard/usha) for repairing, servicing, cleaning etc, replacement of unserviceable parts such as PCB, all filters, membrane, solenoid valve, uv lamp and other minor parts completete all as directed and specified
Taking down geysers carrying for repairing, servicing, cleaning etc, replacement of thermostat, heating element, indicator lamp and thermal cut out incl fixing of PVC cable, sheathed, three core with stranded copper conductor of size 2.5 sqmm and refixing the geysers at location for 25 litres Capacity :- (Note:- Heating element, thermostat etc shall be measured and paid separately as supply only)
Taking down geysers carrying for repairing, servicing, cleaning etc, replacement of thermostat, heating element, indicator lamp and thermal cut out incl fixing of PVC cable, sheathed, three core with stranded copper conductor of size 2.5 sqmm and refixing the geysers at location for 50 litres Capacity :- (Note:- Heating element, thermostat etc shall be measured and paid separately as supply only)
Supply only heating element 1.5 KW, 230 volt round/ triangular in shape ISI marked complete
Supply only heating element 2 KW, 230 volt round/ triangular in shape ISI marked complete
Supply only thermostat ISI marked complete suitable for 25liters capacity geyser
Supply only thermostat ISI marked complete suitable for 50 liters capacity geyser
Supply and replace front PVC grill suitable for window type AC cap 1.5 ton as per existing sample.
Supply and fixing as in replacement for upvc inlet/outlet connector pipe 450mm long for geyser,with brass coupling both ends sutiable to fix inlet/outlet of geyser complete all as specified and as directed by the Engr-in-Charge.
Supply and fixing as in replacement for apparatus plate , including anchor bolt suitable for water storage heater of 25/50 ltrs capacity complete all as specified and as directed.
Rekha Enterprises (BID ID -3288682)
PODDAR SALES CORPORATION (BID ID -3290248)
Rounaq Enterprise (BID ID -3289727)
CONSTRUCTION AND MAINTENANCE ENGINEERING CORPORATION (BID ID -3289729)
K.P Construction Co (BID ID -3290086)
RANA ENTERPRISES (BID ID -3290148)
DS ENTERPRISES (BID ID -3290174)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .