Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.7 LAccepted-AOC 47A C3 OLD DAMU NAGAR PULIAKULAM COIMBATORE 641 045 | COIMBATORE | COIMBATORE | TAMIL NADU | 641045 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹33.3 L+₹4.6 L (16.1%)Rejected-Finance 41B 1H JAYANTIPUR PREETAM NAGAR ALLAHABAD | L2 | Rejected-Finance Other than Lowest bidder | |
| 3 | L3₹34.1 L+₹5.4 L (18.8%)Rejected-Finance 0 | L3 | Rejected-Finance Other than Lowest bidder | |
| 4 | L4₹34.2 L+₹5.5 L (19.0%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest bidder | |
| 5 | L4₹34.2 L+₹5.5 L (19.0%)Rejected-Finance HIG 40 TYPE B DEV PRAYAGAM ADA COLONY JHALWA PRAYAGRAJ U P 211015 | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211015 | L4 | Rejected-Finance Other than Lowest bidder |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
1 Jan 2022, 6:00 pmClosed
GE (AF) Bamrauli
GE (AF) Bamrauli
MAINTINANCE OF E/M WORKS UNDER GE (AF) BAMRAULI
2021_MES_494068_1
8709/E8
Open Tender
Civil Works
Works
180 days
GE (AF) Bamrauli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Bamrauli
₹54,000
2 Apr 2022
11 Dec 2021
3 Jan 2022
11 Dec 2021
1 Jan 2022
27 Dec 2021
Amount
Taking down carefully LT Cable of any size any type and refix in into cable ducting /tray/trenches incluing disconnect and connect the cable with LT Panel as specified and directed by Eng-in-Charge.(Note:- (a) Cable ducting/tray/Earth work shall be measured and paid separately .(b) making hole and filling the hole on wall with PCC (1:2:4) type BO (Using 12.5mm graded stone aggregade, 15mm thick rendereing in cement mortar (1:3) good the disturbed surface with existing colour matching are inclusive in quoted rate(c) minor parts like lugs ,nut bolts required for connection is including in quoted rate)
S & F DLP UPVC trunking compartmant of 150x50 mm size with all accessories with cover clip on seperates partitions lef tright top internal angle, flat angle, rasie function cover to body joints mosaic clip & supprot from mosaic isolation bracket 2 mm thick plastic complete all as directed by Engr-in-Charge
Supplying and fixing of following sizes of Hot dip Galvanized CABLOFIL wire mesh cable trays. It shall be manufactured with a longitudinal 'T- welded' safety edge.Trays shall be constructed with 50 X 100 mm mesh configuration. All Accessories including couplers (CE25+CE30+BTRCC screw-based combination system or EDRN fast coupling) and mounting accessories (Mechanically tested & supplied by cable tray manufacturer must be used) are required of same finish as per site requirement.Trays should comply to standard EN ISO 14 61: at least 550 h of SST.The deflection of cable tray must be no more than 1/200th of the distance between two supports and tested in accordance with the standard IEC 61537. Wire mesh cable trays must be designed with an optimum span of 1.5 m, taking into account the maximum carrying capacity authorised by the manufacturer. Assemblies with specific fire resistant properties must have an E30-E90 certificate. Supports, brackets or hangers designed, mechanically tested and supplied by the wire cable tray manufacturer to be used. Make : Legrand/Panduit/Compscope or equivalant as approved by GE.
Cable Tray Hot Dip Galvanised ( 54mmx150mm)
Cable Tray Hot Dip Galvanised ( 54mmx300mm)
Supply and fixing in replacement XLPE cable Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 4 core complete all as specified and directed.
Supply and fixing in replacement XLPE cable Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 4 core complete all as specified and directed.
Supply and fixing in replacement XLPE cable Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 4 core complete all as specified and directed.
Excavation in trenches/Pits in any type of soil(soft/loose/hard/ dense soil), n.exc. 1.5M wide and n.exc. 1.5M deep and getting out complete, all as specified & directed .
Returning filling in with the earth obtained from Item No 9 here-in-before including spreading, leveling and well ramming in layers n.exc. 25cm thick complete all as specified & directed.
Supply and spreading clean and dry sand (unwashed) in trenches around the cable for cushioning all as specified & directed
Removal of surplus excavated material to a distance n.exc. 50 Mtr and depositing where directed at a level n.exc. 1.5 Mtr above starting point complete all as specified & directed
Supply and laying sub class 'B' bricks (Old Size) laid flat in trenches as cable covers all as specified and directed
S&F Pipes galvanized, pipe 40 mm bore dia“Light Grade”, including fittings complete all as specified and directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Aluminium conductor cable of size 70 to 150 sqmm,Indoor/Outdoor type
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 185 to 240 sqmm,Indoor/Outdoor type
Supply & fixing in replacement and testing of bus-bar chamber out door type single door made of 3.15 mm thick sheet factory made of size 45x30x15 cm fixing inside the existing wall with , 4 Nos copper strip mounted on insulator, 200 Amps, IC, 460 mm long including all incomming and out going connections with lugs of any size, with RYB indicator and PCC work etc. complete all as directed by engr-in-charge.
Supply & fixing in replacement and testing of bus-bar chamber out door type single door made of 3.15 mm thick sheet factory made of size 45x30x15 cm fixing inside the existing wall with , 4 Nos copper strip mounted on insulator, 400 Amps, IC, 460 mm long including all incomming and out going connections with lugs of any size,with RYB indicator and PCC work etc. complete all as directed by engr-in-charge.
Attending day to day complaints and rectifying any type of daily complaints of blockage/ cleaning at Central Sewage Plant and routine maintenance of water supply Installation in general shift alongwith cleaning of grass/ hurbs at undermention sewage Installations and water supply installation under GE (AF) Bamrauli including Sunday and Holiday complete all as specified and directed by Engineer-in-Charge. Note: T&P should be provided by the contractor and deemed in quoted rate. (a) Central Sewage Treatment Plant South Camp (i) Aeration tank -01 No (ii) Clarifier -01 No (iii) Sand filter bed -01 No (iv) Sludge sump -01 No (v) Oxidation pond - 02Nos (b) Sewage Installation at Happy Home (i) Sludge sump with motor -01 No (c) Sewage Installation at VIP Lane (i) Sludge sump with motor -01 No (d) Sewage Installation at Sangam Vihar (i) Sludge sump with motor -01 No
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material.
Bharat Trading Company
A S ENTERPRISES
M/S SURISONS
R K CONSTRUCTION COMPANY
M/S SWASTIK BUILDERS
chauhan construction
M/S SATISH KUMAR
M/S KESRI WORKERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .