| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 CrAccepted-AOC | ₹4.0 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹4.2 Cr+₹14.5 L (3.59%)Rejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹4.2 Cr+₹14.5 L (3.59%) | L2 | Rejected-Finance Not Being Lowest |
| 3 | L3₹4.4 Cr+₹35.1 L (8.68%)Rejected-Finance | ₹4.4 Cr+₹35.1 L (8.68%) | L3 | Rejected-Finance Not Being Lowest |
| 4 | L4₹4.5 Cr+₹49.4 L (12.2%)Rejected-Finance SCF 134 1ST FLOOR ROSE GARDEN COMPLEX GT ROAD BATHINDA 151001 PUNJAB | BATHINDA | BATHINDA | PUNJAB | 151001 | ₹4.5 Cr+₹49.4 L (12.2%) | L4 | Rejected-Finance Not Being Lowest |
| 5 | L5₹4.6 Cr+₹50.8 L (12.6%)Rejected-Finance | ₹4.6 Cr+₹50.8 L (12.6%) | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹4.2 Cr
EMD Value
₹5.0 L
Closing Date
25 Mar 2023, 6:00 pmClosed
CE Bathinda Zone
HQ Chief Engineer Bathinda Zone Bathinda Mil Stn - 151004
CONSTRUCTION OF SECURITY WALL WITH LIGHTING ARRANGEMENTS AND 02 NOS GUARD ROOM AT SRI GANGANAGAR MIL STATION
2023_MES_577232_1
CE BTZ/SGNR/TOKEN-31 OF 2022-23
Open Tender
Civil Works
Lump-sum
457 days
Sri Ganganagar
As per NIT
10 documents required · 10 mandatory
₹2,000
GE Sri Ganganagar
₹5.0 L
Yes
29 Apr 2023
25 Jan 2023
27 Mar 2023
25 Jan 2023
25 Mar 2023
20 Mar 2023
Amount
Lump sum price worked out by the tenderer for “BUILDING /STRUCTURE WORKS" as listed in Schedule ‘A’ Section - I
Lump sum price worked out by the tenderer for “INTERNAL ELECTRIFICATION WORKS" as listed in Schedule ‘A’ Section - II (Part-I)
Sch 'A' Sec - II (Part-II), (INTERNAL ELECTRIFICATION WORKS)
Material and labour for concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green etc colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Galvanised iron sunken terminal box (Min 1.6mm thick sheet, Min 60mm deep, suitable size) concealed in wall, including 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of switches / socket / regulator etc, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switches/ socket / regulator shall be measured and paid separately under appropriate item of BOQ/Sch 'A').
All as per above Srl item No. 04 but for one socket out let 5 Amps point controlled by one switch (on same board) complete all as specified and as directed by Engineer-in-charge. (switches, sockets etc. shall be measured and paid separately under appropriate item of BOQ/Sch A).
All as per above Srl item No. 04 but for one socket out let 5 Amps point controlled by one switch (on independent board and not below the any other switch board) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ/Sch A).
Material and labour for concealed Point wiring for one socket out let 15/16 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Galvanised iron sunken terminal box (Min 60mm deep, suitable size ) concealed in wall, including 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of switches / socket, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ).
Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to 280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of 'B' class insulation, single phase, minimum 30W (± 10%), Temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 No blades, anti suicide down rod minimum length 200mm including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable size from ceiling rose to fan complete all as specified. Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
Supply and fixing exhaust fan (heavy duty) steel body, AC single Phase 230V, 50 Cycle per second, size 300mm sweep with blades and frame including self closing GI louvers off mode protection against birds etc mounted in suitable opening arrangement and connecting up and including three core PVC Insulated PVC Sheathed copper conductor flexible cable1.0 Sqmm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 12 Way 240V, suitable for mounting MCB/Isolator, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB’s shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing MCB ‘B’ curve suitable for 230 volts AC supply, 40 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge
Supply and fixing MCB ‘B’ curve suitable for 230 volts AC supply, 06 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge
Supply and fixing blanking plate suitable for any type of DB complete all as specified and as directed by Engineer-in-charge.
Supply and fixing LED lamp minimum 3 star rated 9/10 W LED B-22 base complete all as specified and directed by Engr-in-Charge with following specifications (a) Lumen system efficacy of lamp should be minimum 100 Lumen per watt. (b) Input Voltage range : 160 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.90 (e) CRI : Minimum 80
Supply and fixing LED complete fitting batten and rod, T-8 Retro LED tube polycarbonate housing 1 x 20 Watt, appx 4 feet long, with decorative box linear LED lighting fixture with CRCA housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) CRCA pre coated housing with coloured plastic end cap. (h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : Minimum 6000K (m) CRI : Minimum 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing LED light fitting 1 x 10 Watt, appx 2 feet long with decorative ultra ceiling square profile linear LED lighting fixture with extruded polycarbonate environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) CRCA pre coated housing with plastic end cap. (h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : Minimum 6000K (m) CRI : Minimum 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing energy efficient LED security light fitting of 25W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing light grade 25mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 40x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Subtotal
Lump sum price worked out by the tenderer for “ INTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Section - III (Part-I)
Sch 'A' Sec - III (Part-II), ( INTERNAL WATER SUPPLY WORKS)
Supply and fixing hand shower (health faucet) chromium finished including 1.2 meter long 8mm dia flexible tube and including wall hook and fixing material complete all as specified and as directed by Engineer-in-charge.
Subtotal
Lump sum price worked out by the tenderer for “PATH WORK" as listed in Schedule ‘A’ Section - IV (Part-I)
Sch 'A' Sec - IV (Part-II), (PATH WORK)
Supply and laying/fixing 60 mm thick (M-35 grade) precast interlocking tile/paving block factory casted (made by using PVC/ Rubber moulds on Vibrating Table Machine) using grey cement and no pigment, any shape haxagon / trigular / zigzag / I-shaped etc, as directed, confirming to relevant IS, laid over and including 25mm thick layer of sand cushining and filling the interstices etc with sand complete all as specified and as directed.
Supply and laying factory made kerb stone of M-25 grade cement concrete laid in position to the required line, level and curvature, jointed with cement mortar (1:3) (1 cement:3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and as directed.
Subtotal
Lump sum price worked out by the tenderer for “SECURITY CUM PERIMETER WALL WORK" as listed in Schedule ‘A’ Section - V (Part-I)
Sch 'A' Sec - V (Part-II), (SECURITY CUM PERIMETER WALL WORK)
Supply and fixing concertina coil with punched tape of 600mm dia having 50 rounds per 6 meter length, with wire diametre 2.5mm dia and blade size 15mmx12mmx0.5mm, spacing of blade 26mm, concertina coil shall be fixed over wall complete all as specified and as directed.
Material and labour for 25mm thick preformed bitumen filler board in crumple joints complete all as specified and as directed.
Subtotal
Lump sum price worked out by the tenderer for “SEWAGE DISPOSAL WORK" as listed in Schedule ‘A’ Section - VI (Part-I)
Sch 'A' Sec - VI (Part-II) (SEWAGE DISPOSAL WORK)
Supply and laying DWCPE (SN8) drain pipes 150mm nominal dia as per IS-16098 (Part-II), laid in trenches on bed including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by Engineer-in-Charge. Note : Excavation, earth work, bedding and pedestal /anchorage if required shall be measured & paid separately under appropriate item of BOQ/Sch A.
Material and labour for granular sub base of kankar or laterite to DWC drain pipes, spread/laid in trenches in layers not exceeding 10cm thick, levelled and rammed including watering complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LLDPE septic tank of capacity 10 users (minimum 5000 ltr) designed to carry sewage and sullage water, including excavation and earth work in any type of soil, installed over and including 100mm thick PCC (1:4:8) type D-2 over 100mm stone hard core including all necessary fittings for connecting to inlet and out let, complete all as specified and as directed.
Soakage well of size 1.20 m dia and 3.0 m effective depth for excavation, in any type of soil, foundation in PCC (1:3:6), walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonry in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size for 5 users complete all as specified and as directed.
Subtotal
Lump sum price worked out by the tenderer for “EXTERNAL ELECTRIFICATION WORKS" as listed in Schedule ‘A’ Section - VII (Part-I)
Sch 'A' Sec - VII (Part-II), EXTERNAL ELECTRIFICATION WORKS
Supply and fixing 1 meter long hot dip galvanised single arm bracket made up of 40NB dia GI pipe suitable to mount on octagonal pole having top dia 70mm including fixing material complete all as specified and as directed.
Supply and fixing energy efficient LED street light fitting of 45W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver complete fitting with all accessories and following specifications, complete all as specified and as directed :- (a) Lumen system efficacy of luminaire should be minimum 105 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : Minimum IP65. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Morethan 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) Note :- Bracket for fixing and cable for connection shall be measured and paid separately under appropriate item of BOQ
Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 3x1.5 Sqmm 1100 Volt , draw through steel conduit for connection to street light from junction box complete all as specified and as directed. Note: Steel conduit shall be measured and paid separately under appropriate item of BOQ
Supply and erecting factory made 9 meter long hot dip galvanised (as per relevant IS with average coating thickness 65 micron) octagonal poles with 155mm dia at bottom and 70mm dia at top A/F made up of 3mm thick HT sheet alongwith foundation type base plate of size 250x250x16mm, foundation bolt 4 Nos of M24x750mm high 'J' type EN8 grade, with inbuilt junction box suitable for incoming 3 phase LT cable 16Sqmm 4 core (opening Door with Hinge and locking arrangements) having 6A SP 'B' class MCB fixed on bakelite sheet and stud type connector inside the pole, the pole shall be adequately strengthened at the location of the door to compensate for the loss in section including excavation and PCC (1:2:4) type B1 for foundation and grouting the bolts as per manufacturers instructions including marking pole number in letters & figures of size not less than 10cm height with red colour enamel paint complete all as specified and as directed. Note:- (i) Srl number will be issued by Engineer-in-Charge.
Material and labour for boring of holes under main road pavement, hard standing or any othe situation by manual mean for accommodate 50mm bore GI tube in the drilled holes, including returning, filling in the end working space including removal of surplus soil and making good the surface complete all as specified and as directed. Note ; (GI pipe and cable shall be measured and paid separately)
Supply and laying GI tubing light grade of size 50 mm bore, ISI marked, including fittings (elbow, tee, socket etc) laid in trenches, under road, insert under holes for cable protection complete all as specified and as directed. (Note:- Excavation and earthwork, boring hole as required shall be measured and paid separately under respective item of Sch.)
Supply and fixing of automatic Street Light control Switch using Infrared Sensor based NATURAL SWITCH for automatic switching of Street Lights. Nature Switch operation should be based on Natural Light Lux* level, required illuminance Level for Switching ON is ≤ 30 Lux and for Switching OFF ≥ 10 Lux. The Sensor should have part night operation facility of minimum 4 hrs. to max. 12 hrs. The circuit should be suitable enough to take three-Phase load of 5 KW with 3 Nos Contactors, 3 Nos incoming MCBs & 3 Nos outgoing MCBs of 16-20 Amps each & Circuit wiring (Copper) of min. 10 sqmm complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI medium grade pipe upto test point or upto main switch board or metallic bodies of electric equipment, fixing with 02 Nos nuts and bolts. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Sand cushioning, with dry and clean river sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and as directed. Note:- (i) Punned thickness shall be considered for payment purpose
Subtotal
Lump sum price worked out by the tenderer for “EXTERNAL WATER SUPPLY WORK " as listed in Schedule ‘A’ Section - VIII (Part-I)
Sch 'A' Sec - VIII (Part-II), EXTERNAL WATER SUPPLY WORK
Material and labour for boring of holes under main road pavement, hard standing or any othe situation by manual mean for accommodate 25mm bore GI tube in the drilled holes, including returning, filling in the end working space including removal of surplus soil and making good the surface complete all as specified and as directed. Note ; (GI pipe and cable shall be measured and paid separately)
Material and labour for Cutting of existing GI pipe for alterations or additions for inserting and including fittings like tee, union, socket etc of suitable size including screwing existing steel tubing (or lengthening screw on pipe to form connector complete all as specified and as directed. NOTE:- Necessary earth work as required shall be measured and paid separately under respective item of Sch.)
Subtotal
Lump sum price worked out by the tenderer for “EXCAVATION AND EARTHWORK " as listed in Schedule ‘A’ Section - IX
Jasraj & Company
RAJENDER ENTERPRISES
ENGINEER CONSTRUCTION PVT. LTD.
BHULLARCONSTRUCTIONS
Pawansut Infra Projects Private Limited
Onkar Nath Bhalla And Sons Contractor Pvt. Ltd.
M/S Shiv Shakti Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .