| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAccepted-Finance TAPARIYAN BEHIND MAHARISHI SCHOOL BABINA BABINA RURAL JHANSI UP 284401 | BABINA | JHANSI | UP | 284401 | L1 | Accepted-Finance Being L1 | |
| 2 | L2₹31.3 L+₹3.4 L (12.0%)Rejected-Finance 1010 NANDANPURA BABINA CANTT DIST JHANSI 284401 | BABINA CANTT | JHANSI | UTTAR PRADESH | 284401 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹31.5 L+₹3.5 L (12.7%)Rejected-Finance 763 MAIN ROAD BABINA CANTT JHANSI UP 284401 | JHANSI | JHANSI | UTTAR PRADESH | 284401 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹32.0 L+₹4.0 L (14.4%)Rejected-Finance NEAR PUMP HOUSE ROAD NEAR RED ROSE SCHOOL BABINA CANTT JHANSI DISTT UP 284401 | JHANSI | UTTAR PRADESH | 284001 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹34.5 L+₹6.5 L (23.4%)Rejected-Finance 704 NEW PUMP HOUSE NEAR RED ROSE SCHOOL BABINA JHANSI UP 284401 | BABINA | JHANSI | UP | 284401 | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | M/S RAJ KUMAR SINGH L6 | M/S Ritu Tandon L4 | Ms Vinay constructions L3 | RAHUL ASSOCIATES L1 | M/s Pratham Enterprises L5 | M/S M S Constructions L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.01 | Demolition of PCC/lime concrete (Other than Ground flooors) terracing including felt in any description and in any position over roof etc complete all as specified and as directed by the Engineer-in-Charge. | 9.55 | Cum | 120 ₹1,145.76 | 200 ₹1,909.6 | 150 ₹1,432.2 | 100 ₹954.8 Lowest | 100 ₹954.8 Lowest | 200 ₹1,909.6 |
| 2.00 | M&L for P.C.C 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in padding over roof finished and laid to required slope complete all as specified and as directed. | 9.55 | Cum | 2,900 ₹27,689.2 | 3,200 ₹30,553.6 | 2,500 ₹23,870 Lowest | 2,800 ₹26,734.4 | 2,700 ₹25,779.6 | 3,000 ₹28,644 |
| 3.00 | M&L for Cutting grooves in brick wall 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed. | 100 | RM | 25 ₹2,500 | 35 ₹3,500 | 50 ₹5,000 | 45 ₹4,500 | 50 ₹5,000 | 20 ₹2,000 Lowest |
| 4.00 | M&L, roughening surfaces of old concrete roof by picking ,sweeping clean and washing down with water to remove dust etc and applying a coat of cement slurry @ 3 Kg per Sqm complete all as specified and directed. | 190.96 | Sqm | 55 ₹10,502.8 | 8 ₹1,527.68 Lowest | 20 ₹3,819.2 | 25 ₹4,774 | 70 ₹13,367.2 | 11 ₹2,100.56 |
| 5.00 | M&L for P.C.C 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in coping or roof kerbs on roof chamfered on edge including troweling slightly complete all as specified and as directed. | 3 | Cum | 3,200 ₹9,600 | 4,000 ₹12,000 | 2,800 ₹8,400 Lowest | 3,000 ₹9,000 | 3,000 ₹9,000 | 3,200 ₹9,600 |
| 6.00 | M&L for 10 mm thick rendering in cement mortar 1:4 on concrete surfaces when concrete is stil green finished even and fair including mixing of water proofing compound as per manufacturer instruction etc complete all as specified and as directed.Note :- Water proofing compound shall be measured separately. | 190.96 | Sqm | 80 ₹15,276.8 | 98 ₹18,714.08 | 100 ₹19,096 | 80 ₹15,276.8 | 110 ₹21,005.6 | 65 ₹12,412.4 Lowest |
| 7.00 | Supply only integral water proofing compound complete all as specified and as directed. | 38.78 | Kg | 35 ₹1,357.44 | 70 ₹2,714.88 | 100 ₹3,878.4 | 50 ₹1,939.2 | 70 ₹2,714.88 | 20 ₹775.68 Lowest |
| 8.00 | M&L applying water proofing treatment with the following:-
(i)First coat of bitumen primer conforming to IS-3384 @ 0.3Kg / sqm to be applied on prepared surface till the surface is properly impregnated incuding of removing of existing APP membrane.
(ii) after the application of approved bituminous primer the water proofing memberne minimum weight 3kg/sqm and minimum 3mm thick reinforced with polyesterd non woven fabric (weight not less then 160gms/sqm) shall be laid on the primed surface by torch application method as per manufactured instruction.
(iii) All joints and change in direction should be curved with cement mortar (1:3) mixed with SBR latex @ 200ml per bag on cement and cured well before laying of membrane. | 190.96 | Sqm | 380 ₹72,564.8 | 335 ₹63,971.6 | 330 ₹63,016.8 | 325 ₹62,062 Lowest | 350 ₹66,836 | 380 ₹72,564.8 |
| 9.00 | Taking up or down existing steel tubing 15 mm dia bore and connections including cleaning for refixing or removal to store complete all as specified and as directed | 20 | RM | 1 ₹20 Lowest | 10 ₹200 | 10 ₹200 | 5 ₹100 | 10 ₹200 | 4 ₹80 |
| 10.00 | Taking up or down existing steel tubing 20 mm dia bore and connections including cleaning for refixing or removal to store complete all as specified and as directed | 30 | RM | 1 ₹30 Lowest | 12 ₹360 | 10 ₹300 | 5 ₹150 | 20 ₹600 | 5 ₹150 |
Tender Value
₹47.4 L
EMD Value
₹94,800
Closing Date
26 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Babina
GE Babina Cantt PIN-284401
SPL REPAIR OF BLDG NO. P-85, P-53, P-54, P-55, P56, P-57, P-58 AND P-59 (A AND B VEH GARAGE) IN CERTAIN UNIT AT AGE B/R-I BABINA UNDER GE BABINA
2025_MES_710912_1
8384/E8
Open Tender
Civil Works
Item Rate
180 days
GE Babina
As per tender documents
8 documents required · 8 mandatory
₹500
GE Babina
₹94,800
Yes
3 Sept 2025
28 May 2025
28 Jun 2025
28 May 2025
26 Jun 2025
12 Jun 2025
Amount
Demolition of PCC/lime concrete (Other than Ground flooors) terracing including felt in any description and in any position over roof etc complete all as specified and as directed by the Engineer-in-Charge.
M&L for P.C.C 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in padding over roof finished and laid to required slope complete all as specified and as directed.
M&L for Cutting grooves in brick wall 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed.
M&L, roughening surfaces of old concrete roof by picking ,sweeping clean and washing down with water to remove dust etc and applying a coat of cement slurry @ 3 Kg per Sqm complete all as specified and directed.
M&L for P.C.C 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in coping or roof kerbs on roof chamfered on edge including troweling slightly complete all as specified and as directed.
M&L for 10 mm thick rendering in cement mortar 1:4 on concrete surfaces when concrete is stil green finished even and fair including mixing of water proofing compound as per manufacturer instruction etc complete all as specified and as directed.Note :- Water proofing compound shall be measured separately.
Supply only integral water proofing compound complete all as specified and as directed.
M&L applying water proofing treatment with the following:- (i)First coat of bitumen primer conforming to IS-3384 @ 0.3Kg / sqm to be applied on prepared surface till the surface is properly impregnated incuding of removing of existing APP membrane. (ii) after the application of approved bituminous primer the water proofing memberne minimum weight 3kg/sqm and minimum 3mm thick reinforced with polyesterd non woven fabric (weight not less then 160gms/sqm) shall be laid on the primed surface by torch application method as per manufactured instruction. (iii) All joints and change in direction should be curved with cement mortar (1:3) mixed with SBR latex @ 200ml per bag on cement and cured well before laying of membrane.
Taking up or down existing steel tubing 15 mm dia bore and connections including cleaning for refixing or removal to store complete all as specified and as directed
Taking up or down existing steel tubing 20 mm dia bore and connections including cleaning for refixing or removal to store complete all as specified and as directed
Supplying, fixing, jointing and testing galvanised iron tubing 15 mm dia bore medium grade with all fitting such as bends, elbow, socket, reducer etc and fixed to wall or laid in floor complete all as specified and as directed.
Supplying, fixing, jointing and testing galvanised iron tubing 20 mm dia bore medium grade with all fitting such as bends, elbow, socket, reducer etc and fixed to wall or laid in floor complete all as specified and as directed.
Fixing only old steel tubing and connections 15mm dia bore obtained from taking down against item No 9 herein before in new or old position fixed to wall, ceiling or laid in floor with new fittings
Fixing only old steel tubing and connections 20mm dia bore obtained from taking down against item No 9 herein before in new or old position fixed to wall, ceiling or laid in floor with new fittings complete all as specified and as directed.
M&L for Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cuttingexceeding 10 cm but not exceeding 20 cm girth in brick walls completed all as specified and directed.
Dismantling water tanks and removing to store of steel/PVC of capacity 500 ltr but not exceeding 1000 ltrs complete all as specified and directed.
S & F 500ltr rotational moulded polyethylene water storage tanks, (cylindrical vertical with closed top) hoisted and fixed in position, all as specified in SSR part I-1991 including 20 mm dia GI pipe light grade washout pipe 450 mm long with plug and 20 mm dia GI pipe light grade over flow pipe 600 mm long with fitting and dismantling of existing unserviceable tank and removing from site, complete all as specified and directed.
S&F 20mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minium weight 210 gms ), complete all as specified and directed
S & F in repair 20mm dia Gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises and complete all as specified and as directed.
M&L for non skid coloured ceramic tiles 7 to 8 mm thick (square / rectengular) area of each tile exceeding 0.18sqm but not exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match to floor etc including 15 mm screed bed with CM(1:4) complete all as specified and as directed.
M&L for non skid coloured ceramic tiles 7 to 8 mm thick (square / rectengular) area of each tile exceeding 0.18 sqm but not exc 0.38 sqm, in Skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match to floor etc and including rendering 10mm thick on fair faces of wall or conc surfaces in CM 1:4 finished rough for wall tiling etc complete all as specified and as directed.
M&L for non skid coloured ceramic tiles 7 to 8 mm thick (square / rectengular) area of each tile exceeding 0.11sqm but not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match to floor etc including 15 mm screed bed with CM(1:4) complete all as specified and as directed.
M&L for joint free glazed coloured tiles 350x250x7mm/450x350x7mm thick for work on vertical surface, set & jointed in cement slurry and pointed in white or coloured cement to match etc including rendering 10mm thick on fair faces of wall or conc surfaces in CM 1:4 finished rough for wall tiling complete all as specified and as directed
Demolition of PCC in any description and in any position etc completed all as specified and directed.
M&L for 75mm thick cement concrete type C-1, 1:3:6 (20mm graded aggregate) as in plinth protection finished even and smooth without using extra cement complete all as specified and directed
M&L for 50mm thick cement concrete type B2, 1:2:4 (40mm graded aggregate) as in floor/hardstanding finished even and smooth without using extra cement complete all as specified and directed.
M&L sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L 60 mm thickness M-40 Grade , machine pressed precast concrete Inter locking paver blocksany shape & size with grey cement and pigment conf to IS-15658-2006 laid dry over sand cushion.(Sand cushion shall be measured and paid separately) completed all as specified and directed.
Demolition of Brickwork of stone/boulder masonry, build in lime mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articlesl etc complete all as specified and as directed.
M&L for old size brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cm (1:6),completed all as specified and directed.
M&L, old size brick work with sub class ;B; bricks old size half brick thickstraight or covered on plan exc 6 m mean radius built in CM 1:4 complete all as specified and directed.
Taking down cement plaster on brick or stone wall including raking out joints, hocking for key scrubbing down with water etc complete all as specified and as directed.
M&L for rendering 10mm thick on fair faces of wall even and smooth finish without using extra cement on conc/brick surfaces in CM 1:6, complete all as specified and as directed
M&L renderig 5mm thick in cement mortar 1:3 on ceiling surface and finished even and smooth with out using extra cment complete all as specified and as directed.
M&L for rendering 15mm thick on fair faces of wall even and fair finish without using extra cement on conc/brick surfaces in CM 1:4, complete all as specified and as directed
M & L for preparation of new plastered surface and applying three coat of white wash on ceiling complete all as specified and as directed.
M & L for Preparation of new plastered surfaceof wall and applying two coat of OBD over a coat of putty complet all as specified and as directed.
M & L for preparation of new plastered surface of wall and applying two coats of premium acrylic smooth exterior weather proof paint of required shade (1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and as directed by Engr-in-Charge
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) exc 1.5 Sqm but n exc 4 Sqm each etc complete all as specified and as directed
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) not exc 1.5 Sqm each complete all as specified and as directed.
Taking down shutters of any description exc 1 sqm and n.exc 2 Sqm each complete all as specified and as directed.
S&F Factory Made Solid PVC Moulded Door Shutter With Particle Board Core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing all as directed and specified by Engineer-in-Charge.
S & F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made
S&F aluminum anodized barrel tower bolts of extruded section & fixed 150 mm long etc complete all as specified and as directed
S&F aluminum handles cast type anodized 150 mm size etc complete all as specified and as directed
S & F butt hinges medium weight cold rolled, mild steel and fixed 100 mm size etc complete all as specified and as directed..
S&F but hinges extruded aluminium alloy with galvanised mild steel hing pin, anodised and fixed, type C-21 100 mm size in toilet for PVC doors etc complete.
S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminium alloy complete all as specified and as directed.
S&F Pressed steel frames for doors(125x60) mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified, supplied and fixed etc complete.
Cutting holes in brick walls built in cement mortar for inserting hold fasts and making good dismantled portion in CM 1:3 or cement conc 1:2:4 type B1 as required exc half brick but not exc full brick wall complete all as specified and as directed.
M&L PCC 1:3:6 type C-1 (using 20mm graded stone aggt) as in filling in holes of hold fasts and back filling of chowkats complete all as specified and directed.
S&F of 35mm thick 2nd class Hard wood paneled door shutter factory made (two panel) with lock rail andpanel of 9mm thick BWP commercial ply wood, the size of rail and stile is as per IS 1003 (Part-I), Kiln seasoned and chemically pressure treated completed all as specified and directed.
S&F factory made fabricated 35 mm thick IInd class HW glazed & skeleton shutters open rebated and prepared to receive glass gauge etc. (without sash bars) edges of framing plain chamfered or rounded fitted with cut & mitered beads for security glass/gauge etc. size of members of shutter as specified in SSR Pt I sec 8 Cl 8.20 (a), divided into squares with plain chamfered rounded, mitered and rebated sash bars etc complete all as specified and as directed.
S&F galvanized mild steel wire cloth 0.63 mm nominal dia of wire and avg width of a-pertare 1.40 mm fixed with tinned tacks or galvanized wire staples etc complete all as specified and as directed.
S&F of CRC sheet box type steel ventilator with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded all as specified and directed by Engr-in-Charge..
S&F of CRC sheet box type steel ventilator with steel handle, and steel peg stay, complete with out glazing bars, dovetailed or welded all as specified and directed by Engr-in-Charge..
M&L framed work as grills, gratings, etc with ends of bars shouldered and/ or riveted into spikes; or forged into spikes, framed guard bars; barred iron doors and similar work confirming to Fe 290. Gd-E-165 completed all as specified and directed.
S & F 3 mm thick Figured glass, pin head type and glazing with oil putty in squares in exc 0.5 sq.m in each pane complete all as specified and as directed.
M&L, preparing for new steel surfaces and applying two coats of synthetic enamel paint over one coat of red oxide primer over 10 cm width or girth complete all as specified and as directed.
M&L, preparing for old steel surfaces and applying one coats of synthetic enamel paint over 10 cm width or girth complete all as specified and as directed.
S&F vitreous china wash down water closet pan of pedestal pattern with seat cove and 'P' or 'S' traps including connecting to trap and to flushing pipe etc making good to floor complete all as specified & as directed.
S & F in repair 10 ltrs capacity PVC low level flushing cistern sleek plus single flush of colour star white Make :- Hindwar with inlet, float valve and handle with 32 mm dia PVC pipe 600 mm long complete all as specified and as directed.
S & F in repair Vitreous China Ware Wash hand basin white, flat back, size 550 x 400 mm size (flat back or angle back type) including cutting for and pinning ends of brackets or erecting stand and waste pipe completed all as specified and directed.
S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm etc complete all as specified and as directed.
S&F in repairs 15mm dia Concealed stop Cock regular body 15mm with flange complete all as specified and as directed.
S&F in repair 15mm bore cast copper alloy chromium plated angle cock with flange complete all as specified and as directed.
S&F in repair 15mm bore fancy type chromium plated bib cock long body with flange etc complete all as specified and as directed.
S&F brass CP mixer 15mm dia bore mixing hot & cold water for wash hand basin screwed down for iron pipe and fixed completed all as specified and directed.
S&F in repair PVC floor trap outlet dia 75mm with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and as directed.
S & F CP Towel ring, complete all as specified and directed.
S&F in repair 125 mm Brass chromium plated shower rose with or without swivel joints, any size, including fixing of steel pipe or union and fixed all as directed.
S&F in repair 25 mm dia chromium plate curtain rod with CP brackets and knobs at both end as per sample approved by Engineer-in-charge.
Demolition and breaking up drain pipes (Salt glazed ware, AC/PVC/CI or Reinforced concrete) set in cement mortar in floors or wall in 100mm dia meter complete all as specified and as directed.
S &F of 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors or wall with necessary iron clips and complete all as specified and directed.
S &F of 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors or wall with necessary iron clips and complete all as specified and directed.
S&F PVC (SWR) bends any radius 110mm bore completed all as specified and directed.
S&F PVC (SWR) bends any radius 75mm bore completed all as specified and directed.
S&F PVC (SWR) junction single, (single T) equal or unequal 75mm bore with access door completed all as specified and directed.
S&F PVC (SWR) junction single, (single T) equal or unequal 110mm bore with access door completed all as specified and directed.
S&F PVC (SWR) vent cowl 110mm bore completed all as specified and directed.
S&F MS chromium plated peg set of five fixing with wall completed all as specified and directed.
M&L for 100mm internal dia Salt-glazed stoneware drain pipes laid in trenches and joints completed all as specified and directed.
M&L for concrete bed to drain pipes in PCC (1:4:8) type D-2 including packing under, and hunching against the side of pipe after they are laid and tested for 100mm dia pipe completed all as specified and directed.
M & L for complete removal of existing treatment from surface of wall all as specified and as directed by the Engineer-in-Charge
M & L for applying one coat of putty all as specified and as directed by the Engineer-in-Charge
M & L for applying two coat of oil bound distemper all as specified and as directed by the Engineer-in-Charge
M & L for preparation of old plastered surface of wall and applying two coats of premium acrylic smooth exterior weather proof paint of required shade (1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and as directed by Engr-in-Charge
M&L, Preparing old plastered/unplastered surfaces of ceiling and applying two coat of white wash complete all as specified and directed.
M&L, Preparing old plastered/unplastered surfaces of wall and applying two coat of white wash complete all as specified and directed.
Demolition of Reinforced Cement Concrete of Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work completed all as specified and directed by Engr-in-Charge.
S&F Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips completed all as specified and directed.
M&L for providing precast reinforced cement concrete 1:2:4 type B1 using 20 m graded stone aggregate as in landings, kitchen slab, cover slabs (for men holes etc) chullah hoods,chhajjas water troughs mangers,shelves and similar articles with plain faces completed all as specified and directed.
M&L for cement concrete (1:4:8) type D2 using 40mm graded stone aggregate as in foundations, filling and mass concrete, complete all as specified and as directed.
M&L cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in Coping for drains, complete all as specified and as directed.
M&L cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in surface channels and drains, complete all as specified and as directed.
M&L rendering 10 mm thick in cement mortar 1:4 on Brick masonry surface finished even and fair without using extra cement,complete all as specified and as directed.
M&L for 25 mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) in sub base of floorings completed all as specified and directed.
Dismantling plain or corrugated asbestos cement /CGI sheeting of any thickness as in roof coverings complete all as specified and directed.
M&L for pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws completed all as specified and directed.
M&L for pre-painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws completed all as specified and directed.
Dismantling wrought iron or mild steel work/timber of any description not otherwise provided complete all as specified and as directed.
S&F for Steel work in tubular post, purline, rafters etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.11611979 grade St.-240 complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of wall even and smooth finish without using extra cement on conc/brick surfaces in CM 1:4, complete all as specified and as directed
M & L for preparation of new plastered surface of wall and applying two coats of cement base paint on external wall surface over a coat of alkali resistant primer complete all as specified and as directed.
Demolition of PCC in any description and in any position etc complete all as specified and directed by Engr-in-Charge.
M&L cement concrete work in pavement of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 20 cm to be done as specified and consolidated completed all as specified and directed by Engr-in-Charge.
M&L for forming 12mm thick expansion joints in 200mm thickness slab filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ completed all as specified and directed.
M&L for 75mm thick cement concrete type C-1, 1:3:6 (20mm graded aggregate) as in plinth protection finished even and smooth without using extra cement incuding joints complete all as specified and directed by Engr-in-Charge.
M&L for Cutting holes in brick walls built in cement mortar for inserting hold fasts and making good dismantled portion in CM 1:3 or cement conc 1:2:4 type B1 as required exc half brick but not exc full brick wall complete all as specified and as directed.
M&L PCC 1:3:6 type C-2 (using 20mm graded stone aggt) as in filling in holes of hold fasts and back filling of chowkats complete all as specified and directed.
S&F for steel rolling shutters (Thickness of laths 1.00mm), but gear operated type with chain wheel and hand chain, as specified including top cover, anchoring rod, hasp and staple, Safety lever locks mild steel with 4 levers, Ball bearing for rolling shutters and one shop coat of primer over paint ; erected in position as indicated, complete: push pull completed all connected items all as specified and directed by Engr-in-Charge and incuding taking down of existing shutters.
M & L for preparing old decorated surfaces of wall and applying one coat of white wash on old surface of wall all as specified and as directed by the Engineer-in-Charge
Taking down carefully copper/ aluminium point wiring (light, fan, socket, or power) complete fitting such as switches, ceiling roses pendants, regulators, sockets, light fitting ceiling fan etc to be measured seperately ) removing materials for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperatly) and making good disturbed surface of walls floors etc all as specified and directed. Note-Responsibility after taking down fan/exhaust fan keep in safe custody of contractor and refix the same after before completion of work the rate of same deemed to be included in the item quoated rate.
Taking down carefully existing wooden board , Main switch, MCB DB boxes with MCBs, sheet metal boxes, cut out, etc of any size any capacity from boards complete all as specified and as directed.
Taking down carefully sub main wiring / service connection twin core from wall / LT pole of any size of Aluminum with wooden batten and or through rigid conduit including GI wire and making good the disturbed surfaces of walls, roofs, floors etc complete all as specified and as directed.
M & L for concealed point wiring for One light point controlled by one switch complete with PVC insulated and unsheathed flame retardant low smoke and halogen ( FRLSH ) cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit not less than 20 mm dia, clip, with MS terminal boxes (not less than 1.6 mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including common earth dolly with 3 mm thick plastic laminated sheet top cover of approved make and colour including 1.5 sqmm green multi stranded copper conductor as continuous earth wire with lugs complete including cutting necessary chases on wall / ceiling surfaces for drawing of conduit & cables as required and making good disturbed surfaces of walls with CM 1:3:6 and matching with the existing surfaces including colour washing all as specified and as directed.
Description same as per item No 119 above but for one fan point controlled by one switch & regulator.
Description same as per item No 119 above but for One 3/5 pin 5 Amp socket outlet point controlled by one switch on independent board.
Description same as per item No 119 above but for One 3/5 pin 5 Amp socket outlet point controlled by one switch on same board.
Description all as per item No 119 above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed flame retardant low smoke ( FRLS ) cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with 2.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed.
S&F switch piano flush button type 5 Amp single pole one way complete all as specified and as directed.
S&F socket outlet 2in1, 3 pin, 5 Amp flush type complete all as specified and as directed.
S&F switch piano flush button type 15 Amp single pole one way complete all as specified and as directed.
S&F socket outlet 2in1, 3 pin, 5 Amp and 15 Amp flush type complete all as specified and as directed.
S & F delux Fan Regulator electronic rotary, step type 240 Volt 50 Hz, complete all as specified as directed.
S & F Lamp holder, PVC suitable for batten fittings complete all as specified as directed
S&F ceiling rose,surface polycarbonate 63 x50mm three terminals complete all as specified and as directed.
M & L for Sub main wiring power/circuit using PVC insulated unsheathed FRLS, stranded copper conductor cable 2 Single core of size 4 sqmm, earth continuity conductor of size 4 sqmm to be drawn through in and including PVC conduit 25 mm dia medium grade concealed in walls/roof complete. Notes:- Two wires of 4 sqmm and one wire of 4 sqmm as earth & PVC conduit shall be measured as one unit. Note: (i) New pvc conduit should be used not less than 25 mm dia. (ii) pvc conduit shall be deemed to be included in quoated rate itself. (iii) Cutting, chasing, plastering, painting etc for fixing of PVC ciondutit /pipe are deepmed to be included in quoted rate.
M & L for Sub main wiring power/circuit using PVC insulated unsheathed FRLS, stranded copper conductor cable 2 Single core of size 2.5 sqmm, earth continuity conductor of size 2.5 sqmm to be drawn through in and including PVC conduit 25 mm dia medium grade concealed in walls/roof complete. Notes:- Two wires of 2.5 sqmm and one wire of 2.5 sqmm as earth & PVC conduit shall be measured as one unit. Note: (i) New pvc conduit should be used not less than 25 mm dia. (ii) pvc conduit shall be deemed to be included in quoated rate itself. (iii) Cutting, chasing, plastering, painting etc for fixing of PVC ciondutit /pipe are deepmed to be included in quoted rate.
S&F sheet metal enclosure double door concealed suitable for distribution boards when MCBs to be used having 100 Amp rated bus bar SPN DB 6 ways 240 V complete all as specified and as directed .
S&F sheet metal enclosure double door concealed suitable for distribution boards when MCBs to be used having 100 Amp rated bus bar SPN DB 4 ways 240 V complete all as specified and as directed .
S&F MCB single pole and neutral 32 Amp 240 V ,10KA , 'C' series, complete all as specified and as directed with copper lugs
S&F MCB single pole 6 to 32Amps 240 V,10KA, 'C' series,complete all as specified and as directed
M & L for Sub main wiring power/circuit using PVC insulated unsheathed FRLS, stranded copper conductor cable 2 Single core of size 6 sqmm, earth continuity conductor of size 6 sqmm to be drawn through in and including PVC conduit 25 mm dia medium grade concealed in walls/roof completed all as specified and directed. Notes:- Two wires of 6 sqmm and one wire of 6 sqmm as earth & PVC conduit shall be measured as one unit.
S & F MCCB DB /TPN Vertical type, suitable for 125 amps MCCB as incommer,made of sheet steel , powder coated with Neutral bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts 4 way Double door complete.
Supply and fix MCCB having breaking capacity of of 16 KA 415V, 4 pole having rating capacity of 63 Amp Ics=100% =Icu complete all as specified and as directed.
S&F sheet metal enclosure double door concealed suitable for distribution boards when MCBs to be used having 100 Amp rated bus bar SPN DB 8 ways 240 V complete all as specified and as directed .
Supply and Fixing Exhaust fans AC single phase 230/240V of size 300 mm sweep, 1400 RPM with louvre complete including with all arrangement of making holes on wall, making good and finishing of disturbed surfaces matching with the existing surfaces, necessary fixing arrangement such as fastener bolts, nuts, washers etc, of appropriate size all as specified and as directed
Supply and laying XLPE insulated, armoured heavy duty electric cables with aluminium conductor, 1100 volts grade, cross sectional area 16 X 4 sq. mm completed all as specified and directed.
Excavation in trenches in any type of soil not exe 1.5 mtrs wide and not exe 1.5 mtr in depth for foundation/ laying of pipe/cables etc and getting out incl forming bottom surface to the required level/slope etc complete all as specified and directed .
Returning fitting in soft/loose soil, including spreading levelling watering and well ramming in layers n.exc 25 cm complete all as directed
Removing excavated soils to a distance n.exc. 50 mtrs and depsiting where directed at a level n.exc. 1.5 above the starting point complee all as specified and directed
Supply laying dry clean RIVER sand free from sharp materials, unscreened filling in trenches around under ground cables for cushioning complete all as specified and directed.
Supplying and laying precast concrete cable cover class LV type -I flat size 250x150x40 mm laid parpendicular to the axis of cable in trenches etc complete as directed.
S &F LED tube light fittings decorative ultra slim linear fixture with extruded aluminium heat sink envioromental friendly Energy efficient ready to use pack ,1x20 Watt, 6000 K, 4 feet, surface mounting type extruded pvc, snap on installers and domestic electronic Driver, connector block etc with all accessories internally prewired & including connecting up with 2 core flexible copper conductor cable and mounting clamps complete all as speicified and directed.
Supply and fix LED 35W building security light fitting,5700 K energy saving & environmental friendly long life versatile pressure die cast aluminium IP 66.road way luminare with high power LEDs as light source and electronic driver suitable for pole dia 35 mm including 35 mm dia light grade tube bracket ,bend to shape 1.80 mtr length with two nos of clamps of size 50mm x 6mm with nuts and bolts,washers etcincluding connection with 1.5sqmm threesingle core PVC insulated and PVC sheathed cable stranded copper cable upto ceiling rose and fixing on walls/pole complete all as specified and directed.
M&L pipe galvanised iron of size 50 mm dia, light grade ISI marked, complete with fittings laid in trenches/ fixed with poles etc as protection to cables complete as ditrected by Engineer in Charge
Supply and laying or fixing or passing through HDPE pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel or strip and overall PVC sheathed, 6 sq mm 2 core ISI Marked as per IS 7098 (Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick weithing not less than 17.5 Kg buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg.50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 2009 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) complete all as specified & testing on completion. NOTE:- (I) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate.
M/S M S Constructions (BID ID -3330488)
Ms Vinay constructions (BID ID -3338198)
M/S Ritu Tandon (BID ID -3337860)
M/s Pratham Enterprises (BID ID -3337465)
M/S RAJ KUMAR SINGH (BID ID -3337849)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .