Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.4 CrAccepted-AOC 302 SIDDHIVINAYAK APPT A WING MUMBAI K K MARG JACOB CIRCLE MUMBAI CITY MAHARASHTRA 400 011 | MUMBAI | MAHARASHTRA | 400011 | ₹3.4 Cr | 1 | Accepted-AOC Being the lowest and reasonable tender. |
| 2 | 2₹3.8 Cr+₹37.6 L (11.0%)Rejected-Finance 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400708 | THANE | MAHARASHTRA | 400708 | ₹3.8 Cr+₹37.6 L (11.0%) | 2 | Rejected-Finance Not being the lowest tender. |
| 3 | 3₹3.8 Cr+₹41.2 L (12.0%)Rejected-Finance 11 A KUTCHERY ROAD BALUGANJ AGRA U P 282 001 | AGRA | AGRA | UTTAR PRADESH | 282001 | ₹3.8 Cr+₹41.2 L (12.0%) | 3 | Rejected-Finance Not being the lowest tender. |
| 4 | 4₹3.9 Cr+₹43.1 L (12.5%)Rejected-Finance B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | ₹3.9 Cr+₹43.1 L (12.5%) | 4 | Rejected-Finance Not being the lowest tender. |
| 5 | 5₹3.9 Cr+₹47.3 L (13.8%)Rejected-Finance D NO 55 41 18 1 DOCTOR S COLONY SEETHAMMADHARA VISAKHAPATNAM PIN 530013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | ₹3.9 Cr+₹47.3 L (13.8%) | 5 | Rejected-Finance Not being the lowest tender. |
Tender Value
₹5.2 Cr
EMD Value
₹5.8 L
Closing Date
23 Jul 2024, 6:00 pmClosed
CE Navy Mumbai
Headquarters, Chief Engineer (Navy) Mumbai, Shahid Bhagat Singh Marg, Colaba Mumbai 400 005
ADDITION ALTERATION AND SPECIAL REPAIRS TO CERTAIN BUILDINGS AT NCHC POWAI
2024_MES_659720_1
87931/E8
Open Tender
Civil Works
Item Rate
639 days
POWAI
As Per Tender Documents
8 documents required · 8 mandatory
₹3,000
GE(NW) BHANDUP
₹5.8 L
Yes
27 Nov 2024
14 Jun 2024
26 Jul 2024
14 Jun 2024
23 Jul 2024
9 Jul 2024
14 Jun 2024 - 20 Jun 2024
Amount
Consultancy for structural audit of buildings
Visual inspection and photography performing a visual survey of the building and recording/ maping on drawing to assess extent of spelled concrete, cracked concrete, honey combing, reinforcement corrosion, delaminated concrete etc. taking photographs and videos to collect evidence of damage to structure.
Ultrasonic pulse velocity test for RCC structure in accordance with IS:516 Part-5: 2018 Section 1 by portable ultrasonic non destructive digital test equipment including chipping out plaster at strategic locations.
Rebound hammer test:- Rebound hammer test in accordance with IS 516 Parts : 2018 Section 4 by portable rebound hammer eauipment at strategic locations.
Core test:- Core cutting and compression test for RCC structure in accordance with IS:516 on RCC members. 70mm core cutting in reinfrocement concrete, core filling by speialized epoxy material/micro concrete with bond coat at strategic locations.
Reinforcement mapping:- Reinforcement mapping test on RCC members to assess covers, spacing of bars including approximate diameter at strategic locations.
Chemical test for RCC structure in accordance with IS 456-2000 using ready made kits and reagents. Sample collected will be from half cell/ carbonation powder. (i) Determination of PH value. (ii) Determination of water soluble sulphates. (iii) Determination of water soluble chloride contents at strategic locations.
Half cell potential test for RCC structure in accordance with IS: 516 Part 5: 2018 section 2 half cell potential to assess the probablity of corrosion of reinforcement at strategic locations.
Carbonation test for RCC structure in accordance with IS : 516 Part 5 : 2018 section 3 carbonation test to measure extent of carbonation from the concrete surface at strategic locations.
Carrying out pull out test at site including drilling hole up to 200 mm in column bear at all heights and levels cleaning the hole with water pressure jet inserting steel bars of max 750 mm length filling hole by Hilti chemical grout of HIT RE 500 or any other techno-commercial equivalent in makes as mentioned in Particular Specifications for different bar dia all as specified and directed.
To check & confirm present status of structure on basis of NDT results and visual inspection.
To provide recommendation for structure repairs and technical specification. Prepairing bill of quantites for the repairs etc all as specified and directed.
Vetting of report from lIT/ NIT.
B/R Portion
Material & Labour for chipping, removing carefully concrete work by low impact hammer, breaker without damaging the structure and cleaning and disposal of debris out side the MoD land etc complete as directed by Engineer-in-charge. Note: Hard concrete should not be removed by force.
Cleaning the existing reinforcement with wire brush/ rotary wire brush to make surface free from rust scales, loose material, dirt etc. complete and providing, applying two coats of alkaline rust converting primer confirming to ASTMB-117, on the existing rebars and allowing it to react with rust for 6 hrs and form a corrosion resistant, insoluble and adherent protective layer, including cleaning the reinforcement, wirebrushing to remove loose rust spalls, with time interval of 1 hour between the coats.
Providing and application of hitech concrete penetrating, water based, organic, Bi-polar, calcium nitrite free, migratory corrosion inhibitor on concrete surface having pH 9.5 which migrates to a virtual extent of 100 mm inside concrete through pores, to inhibit the corrosion process on embedded steel at both anodic and cathodic ends by depassivating the electro-chemical reaction in that region thereby protecting rebar on all sides.
Providing and application of full and unbroken coating of anticorrosive protective zinc rich epoxy coating on exposed reinforcement in two coats with time interval of minimum 1 hours between each coat including mixing of both components by weight as per manufacturer's specifications, brush application, curing to form a anticorrosive protective coating with high mechanical strength to cementitious repair works, etc complete.
Mixing and applying SBR latex modified cementitious bond coat using cement 2.2 kg per square metre on prepared concrete surfaces of parent material complete all as specified and as directed by the Engineer-in-charge. (Note: SBR latex shall be paid for separately).
Material & Labour for providing Polymer Bonding Agent of make Fosroc (NITOBOND-SBR) or any other techno-commercial equivalent in makes as mentioned in Particular Specifications, as approved by the GE followed by flexible polymer based putty (1 cement : 1.2 fine sand : 20% polymer by weight of cement : water as required) on cracks after cutting the cracks to a 'V' shaped groove upto 10 mm wide and 10 mm deep in structural RCC members, finished with spatula etc. complete all as specified and directed by the Engineer-in-charge.
Mixing and applying SBR latex modified cement mortar 20 mm thick in cement sand mortar in proportions of 1:3 (1 part cement and 3 parts quartz aggregate) with polymer admixed in proportions as approved, including trowelling with wooden tools on prepared concrete surfaces of parent material complete all as specified and as directed by the Engineer-in-charge. (Note: Rate includes the rate of steel scaffolding. No separate payment Shall be paid for scaffolding) (Note: SBR latex shall be will be measured and paid separately as supply only).
Mixing and applying SBR latex modified cement mortar 30 mm thick in cement sand mortar in proportions of 1:3 (1 part cement and 3 parts quartz aggregate) with polymer admixed in proportions as approved, including trowelling with wooden tools on prepared concrete surfaces of parent material complete all as specified and as directed by Engineer-in-charge. (Note : Rate includes the rate of steel scaffolding. No separate payment shall be paid for scaffolding). (Note: SBR latex will be measured and paid separately as supply only).
Rebuilding the section of damaged RCC elements to required size avg thickness upto and including 50 mm by providing and casting with microconcrete of grade M-40 or above including providing and fixing of watertight shuttering of minimun 12 mm thickness with supporting framework, all lead lift, mixing, placing, deshuttering, levelling the surface by grinding off cementitious slurry or construction joint differences if any to satisfaction of the Engineer-in-charge, etc. complete.
Rebuilding the section of damaged RCC elements to required size avg thickness beyond 50mm upto and including 70 mm by providing and casting with microconcrete of grade M-40 or above including providing and fixing of watertight shuttering of minimun 12 mm thickness with supporting framework, all lead lift, mixing, placing, deshuttering, levelling the surface by grinding off cementitious slurry or construction joint differences if any to satisfaction of the Engineer-in-charge, etc. complete.
Taking down loose material by chiselling, chipping from beam, stair, column, railing, pardi walls, ceiling, etc. cleaning the surface and applying presure guniting in CM 1:3, 30mm thick including use and waste form work and providing welded wire mesh size 100 x 100 mm of GI wire 3, finishing the guniting surfaces in cement compound 2% by weight of cement and finishing even and fair / smooth as required without using extra cement to match the existing all as specified and directed by the Engineer-in-charge.
Material & Labour for mild steel CRS TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-charge.
Material & Labour for mild steel CRS TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-charge.
All as per item No 27 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed by the Engineer-In-charge.
Taking down cement or cement lime plaster on brick or stone walls, any description, including raking out joints, hacking for key, scrubbing down with water, etc including disposal of debris out side the MoD land etc complete all as specified and directed by the Engineer-in-charge.
Taking down chowkats or frames, exc 1.5 sqm but not exc 4 sqm each with shutters (without taking off shutters from the frame) including taking down of hold-fasts by cutting/chasing etc. from existing surfaces and also grills/guard bars (where exists), complete all as specified and directed by the Engineer-in-charge.
Taking down chowkats or frames, not exc 1.5 sqm each with shutters (without taking off shutters from the frame) including taking down of hold-fasts by cutting/chasing etc. from existing surfaces and also grills/guard bars (where exists), complete all as specified and directed by the Engineer-in-charge.
Taking down shutter exc 1 sqm but not exc 2 sqm each and refixing in the same opening after easing and adjusting complete all as specified and directed by the Engineer-in-charge.
Demolition of cement concrete in ground floors (un-reinforced) and paving not exc. 15cm thickness (below or above ground level) including removing debris outside MoD land complete all as specified and directed by the Engineer-in-charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete and removing the retrieved debris outside MoD land, complete all as specified and directed by the Engineer-in-charge. Note: (i) Before quoting the tender, the bidders are advised to ascertain the distance outside MoD land at which the excavated material/ debris are to be disposed off. No extra claim what-so ever shall be entertained on this account. (ii) This item shall be considered as per the requirement at site.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles including disposal of debris out side the MoD land etc complete all as specified and directed by the Engineer-in-charge.
Material & Labour Brick work with sub class 'B' brick and of class designation 35 (min. compressive strength 35 kg/sqcm) straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and directed by the Engineer-in-charge.
Providing and applying sand face 20 mm thick plaster with ready mix prepacked proportioned dry mix mortar, blended with PP fibers on other than fair faces of brick wall or concrete surfaces additives, on external surfaces including transporting of material, mixing, curing, etc. complete all as specified and directed by the Engineer-in-charge. MAKE: M/s ACC Accoplast/ M/s Ultratech Readiplast/ M/s Magicrete Magicplast/ CK Birla's AEROCEN
Providing and applying fair finish 15mm thick plaster with ready mix prepacked proportioned dry mix mortar fair faces of brick wall or concrete surfaces additives, on internal surfaces including transporting of material, mixing, curing, etc. complete all as specified and directed by the Engineer-in-charge. MAKE: M/s ACC Accoplast/ M/s Ultratech Readiplast/ M/s Magicrete Magicplast/ CK Birla's AEROCEN
Providing and applying fair finish 10mm thick plaster with ready mix prepacked proportioned dry mix mortar fair faces of brick wall or concrete surfaces additives, on ceiling including transporting of material, mixing, curing, etc.complete as per direction of Engr-in-charge. MAKE: M/s ACC Accoplast/ M/s Ultratech Readiplast/ M/s Magicrete Magicplast/ CK Birla's AEROCEN
Material & Labour for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper including application of 3mm thick wall care putty and one coat of primer for smooth finish using airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 metre. The spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in Particular Specifications and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface all as specified and directed by the Engineer-in-charge. Note:- Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer.
Material & Labour for preparation of new plastered surfaces of ceiling and applying two coats of oil bound distemper including application of 3mm thick wall care putty and one coat of primer for smooth finish using airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 metre. The spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in Particular Specifications and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface all as specified and directed by the Engineer-in-charge. Note:- Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer.
Material & Labour for complete removal of wall existing treatment by scraping with mechanical wall sander having CAT Part Trucare series H-01 with variable speed control 1500-2700 RPM (having mechanical vacuum mechanism) sanding pad of 180 mm having dia of 7"/9" to make the surface free from dust, loose paint etc. by skilled labour including water proof cement based putty @ 1 kg (undiluted) per sq metre of average thickness 2 mm in two coats (applying not less than 1 mm thick in one coat) over the plastered/old painted wall after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacume mechanism) having rpm not less than 1500, sanding pad of 240 Grit or above to make the surface free from dust etc. by skilled labour and applying two coat of oil emulsion distemper @1 litres (undiluted) /10 sqm diluted with water in 2:1 ratio applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in both the coats of paint as per manufacturer instructions all as specified & directed by the Engineer-in-charge.
Material & Labour for complete removal of ceiling existing treatment by scraping with mechanical wall sander having CAT Part Trucare series H-01 with variable speed control 1500-2700 RPM (having mechanical vacuum mechanism) sanding pad of 180 mm having dia of 7"/9" to make the surface free from dust, loose paint etc. by skilled labour including water proof cement based putty @ 1 kg (undiluted) per sq metre of average thickness 2 mm in two coats (applying not less than 1 mm thick in one coat) over the plastered/old painted wall after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacume mechanism) having rpm not less than 1500, sanding pad of 240 Grit or above to make the surface free from dust etc. by skilled labour and applying two coat of oil emulsion distemper @1 litres (undiluted) /10 sqm diluted with water in 2:1 ratio applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in both the coats of paint as per manufacturer instructions all as specified & directed by the Engineer-in-charge.
Material & Labour for two coats of acrylic paint exterior grade weather coat, antifungal (100% Acrylic) over one coat of primer including prepartion of newly plasterd surfaces of walls etc on external surfaces all as specified and directed by the Engineer-in-charge. Note: The aforesaid treatment shall be got executed by the contractor from the authorised applicator of the manufacturer(s) and also necessary authenticated documents on account of above shall be submitted by the contractor to the GE.
Material & Labour for preparation of old undecorated surfaces of walls, soffit fascias or chajjas etc and applying one coat of weather proof Acrylic based paint (100% Acrylic) exterior grade over a coat of primer complete all as per manufacturer's instructions all as specified and directed by the Engineer-in-charge. Note: The aforesaid treatment shall be got executed by the contractor from the authorised applicator of the manufacturer(s) and also necessary authenticated documents on account of above shall be submitted by the contractor to the GE.
Supply & Fixing 2nd class hard wood plain, solid straight chowkats and frames, wrought framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed by the Engineer-In-charge.
Supply & Fixing 2nd class hard wood 35mm thick factory made plain framed, panelled shutters (two panels) with lock rail and panel of 9mm BWP commercial or 12mm veneered particle board with commercial veneer on both faces. The size of rail and stile as per IS 1003 (Part-I) kiln seasoned and chemically pressured treated complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing 2nd class hardwood 35mm thick skelton shutters, open rebated and prepared to receive wire mesh edge of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing mesh etc, sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and directed by the Engineer-In-charge.
Supply & Fixing stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube, as shown in drg for SI No. 8095 on serial page No. 180 in SSR-2020 (Part 2), complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing factory made solid Panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet with free EPS shall be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, as per specification & drawing for SI No.8080 on serial page No.176 in SSR-2020 (Part 2), complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing bands, straps, supports or stays for rainwater, hold fasts, etc. and similar small articles made out of mild steel flat etc. of grade Fe-290 Gde-E-165 complete all as specified and directed by the Engineer-in-charge.
Material & Labour for PCC 1:2:4 type B1 cement concrete as in bed blocks, hold fasts etc. including provision of necessary form work, complete all as specified and directed by the Engineer-in-charge.
Material & Labour for preparing new wood or wooden surfaces over 10 cm of width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by the Engineer-in-charge.
Material & Labour for preparation of old wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint all as specified and directed by the Engineer-in-charge.
Supply & Fixing Aluminium anodised frame for door, windows, ventilators etc. with one or more rebates including joining cleat for fixing etc.fixed type/louvered window or ventilator without sash bar, aluminium including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, sliding rollers, rubber gasket etc. complete all as specified and directed by the Engineer-in-charge. Note: a) Glazing shall be measured seperately. b) Item shall be paid as per weight of aluminium section. c) The rate quoted shall be inclusive of neoprene beading, glazing clips, screws, etc., as required which shall not be measured for arriving the weight. d) The rate shall be inclusive of the locking arrangement including complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing surface area. Note: - The size of aluminium section shall be as per HQ CE(N) MZ TD Drawing No. TD/2021/01 to 05 and Sill to be provided as per HQ CE(N) MZ TD of Sill Type 'A' and 'B' repectively. The contractor shall provide Granite stone slab (The rate of granite shall be paid seprately under respective item) with width equal to the thickness of wall all around the window opening any cutting required to jamb and sill to accommodate the aluminium window shall be done including make good the disturbed surfaces shall be include in the quoted rate againt the item.
Supply only 5.5 mm thick sheet glass, pin head type and glazing with oil putty in square not exceeding 0.5 sqm in each pane etc. complete all as specified and directed by the Engineer-in-charge.
Supply only 5.5 mm thick glass ordinary quality in plain exc 0.50 sqm each pane including rubber beading or gasket for aluminium section complete all as specified and directed by the Engineer-in-charge.
Supply only 5.5 mm thick figured glass/pin headed type and glazing with oil putty in square not exceeding 0.5 sqm in each pane, fixed in aluminium ventilator, complete all as specified and directed by the Engineer-in-charge.
Supply only stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm, complete all as specified and directed by the Engineer-in-charge.
Taking down aluminum window shutter with frame of any size carefully and refixing the same in position after repair of building, replacing rubber bead, worn-out handles and replacing existing broken aluminum section/glass/wire cloth/bakelite sheet, if any, and making window shutter serviceable, complete all as specified and directed by the Engineer-in-charge. Note: Aluminum section / glass / wire cloth / bakelite sheet, handle etc shall be measured and paid separately as supply only. Fixing by element of these items shall be deemed to be included in quoted rate.
Supply & Fixing mild steel framed work such as grills, gratings etc, with ends of bars shouldered or rebated or forged into spikes, framed guard bars, barred iron doors, railings, framework of water tanks and similar work conforming to Fe-290 Grade-E-165, complete all as specified and directed by the Engineer-in-charge.
Material & Labour for aluminium anodised grill with suitable aluminium anodised frame section manufactured by M/S Deco grill pattern DG-102 (7.5mm thick and aparture 50mm) or any other techno commercial equivalent in repair complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing 100mm size SS butt hinges medium weight fixed with SS screws complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing stainless steel grade 304, 150 mm long barrel tower bolt fixing complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing stainless steel grade 304, 300 mm long SS sliding door bolt plate type decorative with bright bolt not less then 12 mm dia with and incl min of 6 bolt and nuts, four on bolt plate and two on staple fixing complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing stainless steel grade 304, 150 mm decorative type pressed handle fixing complete all as specified and directed by the Engineer-in-charge.
Material & Labour for 75mm thick PCC (1:3:6 ) type C-2 using 40 mm graded stone aggregate as in plinth protection laid in panels, finish the top surfaces even and smooth complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing in repairs Nahani trap with grating including jointing to waste pipe of 75mm dia in and including cement concrete type B1 (1:2:4), complete all as specified and directed by the Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), including disposal of debris out side the MoD land etc. complete all as specified and directed by the Engineer-in-charge.
Material & Labour for glazed Vitrified tiles of size 600mmx600mmx8-9mm thick in floors over and including 15mm thick screed bed in cement mortar (1:6) set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by Engineer-in-charge.
Material & Labour for glazed Vitrified tiles of size 600mmx600mmx8-9mm thick in skirting over & including 10mm thick cement plaster in cement mortar (1:4) and pointed in white or coloured cement to match complete all as specified and as directed by the Engineer-in-charge.
Material & Labour for non skid ceramic digital coloured ceramic tiles 7 to 8 mm thick of size 400mm x 400mm in floors etc. set and jointed in neat cement slurry over 15 mm thick screed bed in cement mortar 1:6 and pointed in white or coloured cement to match complete all as specified and directed by the Engineer-in-charge.
Material & Labour for digital coloured ceramic tiles 300x450x7-8 mm thick in vertical surfaces (including designed borders) such as skirting and dados set and jointed in neat cement slurry pointed in coloured cement to match over rendering 10 mm thick on fair faces of brick work in CM (1:4) complete all as specified and directed by the Engineer-in-charge. Note:- Rate of Designer border in vertical surface shall be deemed to be included into quoted rate.
Material & Labour for 25 mm thick PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in sub base floor / pavings complete all as specified and directed by the Engineer-in-charge.
Demolition of lime concrete or lean concrete from sunken floor including floor tiles, hacking of surfaces after cleaning with wire brush (floor and adjoining walls) and disposing off debris outside MoD land complete all as specified and directed by the Engineer-in-charge.
Material & Labour for filling of lean concrete 1:5:10 type E2 (using 40 mm graded stone aggregates) in sunken portion, as per requirement complete all as specified and directed by the Engineer-in-charge.
Treatment of sunken floor slab comprises of the following specifications and all as specified:
(i) Material and labour for cleaning of the sunken /lowered portion of the RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chiesel out any mortar sticking to the surface and brooming / washing completely. 40 mm avg thick PCC 1:2:4 type B-0 using 12.5 mm graded aggregate as in padding concrete to achieve proper slope including 50 mm dia 350 mm long medium grade GI pipe spouts with wire guage on inside mouth to be fixed. (ii) Rendering of uneven surfaces with 10 mm thick using factory manufactured pre mix / ready mix mortar addition and including WPC of UltraTech WP+ 200 or other equivalent @ 200ml per bag of mortar fill it with water and check dampness and seepage. where dampness and seepage noticed nozzles shall be fixed and grouting carried out. (iii) All junctions points of side walls where CI/GI pipes are passing through shall be sealed with epoxy putty (iv) After drying putty wash the slab and sides of sunken portion with water and make it clean and clear (v) Material and labour for applying two coat of polymer modified cementious water proofing coating as per manufactures instructions to bottom and vertical sides up to finished flooor level +100 mm height. The thickness of two layer shall be 1 mm. When the second layer is still sticky, coarse sand spry shall be carried out or vertical and bottom surface of the sunken portion all as specified and directed. (vi) Plaster the bottom and sides up to bottom of the skirting with minimum 20 mm thick using factory manufactured pre mix / ready mix mortar addition and including WPC of UltraTech WP+ 200 or other equivalent @ 200ml per bag of mortar including rounding of corners and junctions sloping towards spout. Note:Test the water proofed area (ponding test) by filling water for atleast 72 hours and tested for leakage seepage and to the entire satisfaction of GE . Test shall be done in presence of reps of PMG and record for each sunken slab shall be maintained. the treatment shall be carried out by authorised applicators of chemicals. (vii) All pipes laid in sunken portion shall be covered with 50 mm thick PCC 1:2:4 all around after painting with anticorrossive black japan paint
Taking up or down steel tubing and connections including cleaning for refixing or removal of 20 mm bore including complete all as specified and directed by the Engineer-in-charge.
Taking up or down steel tubing and connections including cleaning for refixing or removal of 25 mm bore including complete all as specified and directed by the Engineer-in-charge.
Taking up or down steel tubing and connections including cleaning for refixing or removal of 40 mm bore including complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing of CPVC pipes SDR 11 & plain CPVC SDR 11 Fittings of size 20mm outer diameter (including special fittings like brass elbow, brass tee, male threaded brass adaptor, female threaded brass adaptor, etc. required for fixing of bib tap, stop valve, etc.) fixed on the surfaces of walls/ceiling/laying over floors, complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing of CPVC pipes SDR 11 & plain CPVC SDR 11 Fittings of size 25mm outer diameter (including special fittings like brass elbow, brass tee, male threaded brass adaptor, female threaded brass adaptor, etc. required for fixing of bib tap, stop valve, etc.) fixed on the surfaces of walls/ceiling/laying over floors, complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing of CPVC pipes SDR 11 & plain CPVC SDR 11 Fittings of size 40mm outer diameter (including special fittings like brass elbow, brass tee, male threaded brass adaptor, female threaded brass adaptor, etc. required for fixing of bib tap, stop valve, etc.) fixed on the surfaces of walls/ceiling/laying over floors, complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing in repairs vitreous china wash down, white, European type, 1st quality, water closet pan (pedestal pattern) with 'P' or 'S' trap including plastic seat cover to match with colour of WC, closed pattern with flat bottom & cover including connecting to trap and flushing pipe, anti-syphonage pipe etc and screwed with ms screws complete all as specified and directed by the Engineer-in-charge. Make & Model : EWC "CONVENTIONAL" CAT part No. S1053102 of CERA and seat cover "CAJOL" CAT Part No. B1510123 or any other techno-commercial equivalent in makes as mentioned in Particular Specifications.
Supply & Fixing in repairs 10 litres capacity, PVC valveless, low level, syphonic type, white, plastic twin flushing cistern with inlet, ball valve, float and handle including brackets, flush pipe of polyethylene of low or high density or PVC, 32mm dia complete all as specified and directed by the Engineer-in-charge. Make: Model 'COMPASS' CAT Part No. B1020106 of CERA or any other techno-commercial equivalent in makes as mentioned in Particular Specifications.
Supply & Fixing wash basins, vitreous china, white, flat back, of size 450mm x 300mm or nearest size conforming to model 'CALBURT' CAT Part No. S2020137 of CERA or any other techno commercial equivalent in Jaquar, Perryware or Hindware with and including cast iron brackets [embedded in wall upto 110 mm depth with and including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate or fixing on wall with and including rawl plug and screws], 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings, including painting of fittings and brackets, sealing gap between wall and table top basin with silicone sealant, cutting and making good the walls wherever required and connecting to supply pipes, waste pipes, waste fittings etc. with silicone sealant complete all as specified and directed by the Engineer-in-charge. Make : CALBURT' CAT Part No. S2020137 of CERA or any other techno-commercial equivalent in makes as mentioned in Particular Specifications.
Supply & Fixing in repair 15 mm bore pillar taps swan neck cast copper alloy, with capstan heads, chromium plated, screwed down, fancy type high pressure, with or without lettered 'HOT or COLD' with long screwed sunk and fly nuts complete all as specified and directed by the Engineer-in-charge. Make:- Cera CAT Part No. F 2008105 or any other techno-commercial equivalent in makes as mentioned in Particular Specifications.
Supply & Fixing in repair 15 mm bore fancy type concealed stop cock (regular body) cast copper alloy screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-charge. Make:- Cera Cat Part No F 1015361 or any other techno-commercial equivalent in makes as mentioned in Particular Specifications.
Supply & Fixing in repair 15 mm bore fancy type bib taps long body cast copper alloy 15mm bore with fancy chromium plated screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by the Engineer-in-charge. Make:- Cera Cat Part No F 1015151 or any other techno-commercial equivalent in makes as mentioned in Particular Specifications.
Supply & Fixing in repairs PVC connectors of 15 mm size with PTMT nuts of length 450 mm length complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing in repairs brass chromium plated, shower rose, 125mm size, complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing towel rail 600mm long of PTMT (minimum weight 190 grams) fixed with and including chromium plated brass screws and wooden/plastic cleats, complete all as specified and directed by the Engineer-in-charge.
Supply and fixing 32mm dia high density polyethylene pipes (HDPE) of pressure rating 6 kgf/sqcm of fixed to wall, ceilings or floors for draining out the waste water from Kitchen Sink, WHB etc including socket, tee, bend etc & screw complete all as specified and directed by Engineer-in-charge.
Supply & Fixing in repair 15 mm bore fancy type health faucet with SS hose complete all as specified and directed by the Engineer-in-charge. Make:- Cera CAT Part No. F 8030106AB or any other techno-commercial equivalent in makes as mentioned in Particular Specifications.
Supply & Fixing in repair CP corner glass with brass bracket screws etc complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing in repair CP soap dish complete all as specified and directed by the Engineer-in-charge. Make:- Cera CAT Part No. F 5002106 or any other techno-commercial equivalent in makes as mentioned in Particular Specifications.
Supply & Fixing in repair toilet paper holder having minimum dia of rod 5mm and with SS plate complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing 160 mm bore UPVC Rain Water Pipe type 'A', single socketed, in any length with and including rubber ring joints, fixed to wall with dash through fasteners and rain water bracket suitable for 160mm pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01 including taking down existing RWP of any description, complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing 160 mm bore UPVC (SWR) Bends/Shoes with and including rubber ring joints, complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing machine cut cudappa stone slab 20-25mm thick over cement screed bed CM 1:4 10 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab complete all as specified and directed by the Engineer-in-charge.
Material & Labour for 18-20mm thick granite (of any type) work (table rubbed and Z-black polished) as in jambs, pillars, door and windows-cill, cooking platform, jambs, wash basin platform and the like in cement mortar (1:4) including pointing in white / coloured cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting of oval shape for fixing of counter wash hand basin etc. over and including 10mm thick rendering/screed in CM 1:4 on fair faces of brick/concrete surfaces complete all as specified and directed by the Engineer-in-charge.
Material & Labour for 18 to 20 mm thick Udaipur green Slab (table rubbed and Polished) including molding of edges in single piece as in window cills, jambs and the like over and including 15mm thick cement mortor screed bed in cement mortar 1:4, also including pointing with white cement (1:2) using marble dust with admixture of pigment to match with the shade of stone slab, complete all as specified and directed by the Engineer-in-charge.
Material & Labour for machine cut pre-polished kota stone slab as in flooring, steps, window cill and jams etc or similar work 20-25mm thick in single piece with round nosing over and including screed bed or bedding layer of mortar 20 mm thick for laying floor finishes laid and jointed with grey cement slurry mixed with pigment in cement mortar (1:6) to match the shade of the slab including rubbing and polishing complete all as specified and directed by the Engineer-in-charge. (Note : The rate includes the cost of cement screed bed)
Material & Labour machine cut pre-polished kota stone slab in riser of steps, skirting, dado and pillar or similar work 20-25mm thick laid over and including screed bed or bedding layer of 20mm thick for laying floor finishes laid and jointed with grey cement slurry with pigment in cement mortar (1:6) to match the shade of the slab including rubbing and polishing complete all as specified and directed by the Engineer-in-charge. (Note : The rate includes the cost of cement screed bed)
Material & Labour for three numbers of serration as in treads of steps in single piece kota stone for staircase complete all as specified and directed by the Engineer-in-charge.
Material & Labour for half rounding to edges of stone slabs as in steps and other similar situations, complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing pre-painted colour coated galvalume aluminum zinc coating GI based corrugated style pattern steel sheet 0.50mm thick having tensile strength not less than 550 MPa fixed to steel frame using L or J bots with washer in roofs including making good joint frame and sheets, complete all as specified and directed by Engineer-in-charge.
Material & Labour for providing cement concrete 1:2:4 type B0 (using 12.5mm graded aggregate) as in roof kerbs of mud stops, rounded or chamfered on edges including cutting groves in wall and making good complete all as specified and directed by the Engineer-in-charge.
Taking down CI soil, waste and vent pipes of any length and any size including fittings including cutting of holes wherever required complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing 110 mm bore PVC (SWR) soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls with dash through fasteners and rain water bracket suitable for 160mm pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01.
Supply & Fixing 110mm PVC (SWR) bends complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing PVC (SWR) branch piece, Single (single Y) equal or unequal for 110 mm bore access door eye complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing 110mm bore PVC (SWR) vent cowl complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing 75 mm bore PVC (SWR) soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls with dash through fasteners and rain water bracket suitable for 160mm pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01.
Supply & Fixing 75mm PVC (SWR) bends complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing PVC (SWR) branch piece, Single (single Y) equal or unequal for 75 mm bore access door eye complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing 75mm bore PVC (SWR) vent cowl complete all as specified and directed by the Engineer-in-charge.
Material & Labour for preparing of new steel surfaces of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by the Engineer-in-charge.
Material & Labour for preparing new plastered surfaces of wall and applying three coats of white wash complete all as specified and directed by Engineer-in-charge.
Material & Labour for preparing old plastered surfaces of wall and applying one coat of white wash complete all as specified and directed by Engineer-in-charge.
Dismantling of roof terracing cement / brick concrete (un-reinforced) and existing water proofing treatment of any thickness in any position and of any portion from top of roof of building, cleaning surface of roof with wire brush / mechanical brush and with water thoroughly to remove all dust / dirt and loose particles to expose base concrete roof slab and removal of rubbish / demolished material outside of MoD land complete all as specified and directed by the Engineer-in-charge.
Material & Labour for PCC 1:2:4 type B0 using 12.5 mm graded aggregate with 2% by weight of cement or as per manufacturer's instructions, water proofing as in levelling course, haunching, coping and similar works over RCC roof surface and RCC over head tank top surface including rounded or chamferred on edges and formwork etc. finished smooth with using extra cement all as specified and directed by the Engineer-in-charge. Note: Water proofing compound will be measured & paid seperately.
Material & Labour for application of 7 layer of waterproofing system on leaking roof by thorough surface preparation, opening and filling of cracks, application of absorption coat of thermacool WP51, application of sandwich coat of elastomeric (Thermacool WP51 + cement) waterproofing layer with 80 GSM non woven fibre mesh, application of 3rd coat of elastomeric (Thermacool WP51 + cement) waterproofing layer and top coated with two coats of thermacool 0.3C elastomeric, waterproofing solar IR heat reflective coating having a min. service life of 10 years complete all as specified and directed by the Engineer-in-charge.
Supply only polymer based water proofing compound.
Supply & Fixing in repair rotational moulded polythylene water storage tanks, double layered (ISI marked) of 2000 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I, including provision of necessary fittings for connecting the overflow, drain out, inlet and outlet pipes, complete all as specified and as directed by the Engineer-in-charge.
Supply & Fixing in repair/replacement of gun metal globe or gate valves 40 mm size, with iron wheel head, screwed both ends for iron/CPVC pipe and fixed complete all as specified and directed by Engineer-In-charge.
Supply & Fixing in repair/replacement of gun metal globe or gate valves 25 mm size, with iron wheel head, screwed both ends for iron/CPVC pipe and fixed complete all as specified and directed by Engineer-In-charge.
Supply & Fixing in repairs Ball brass valves of size 20 mm bore high pressure, polythene float and fly nut, screwed for iron pipe or brass frame etc, complete al as specified and directed by the Engineer-in-charge.
Supply & Fixing in repair sinks made of stainless steel with drainage board, 1mm thick, kitchen or laboratory, with plugs, waste pipes, washers and wastes coupling; including bedding in cement mortar on to dwarf wall or including provision of fixing cantilever CI brackets and connecting union to pipe, also including PVC waste pipe, overall size 915mm x 460mm with bowl size 410mm x 330mm x160mm, complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing in repairs stainless steel plate rack 0.63mm thick stainless steel sheet overall size stainless steel plate rack 31” x 31” x 10” kitchen rack all as specified and as directed by the Engineer-in-charge.
Supply & Fixing of 18 mm thick Celuka ply prelaminated both side with decorative choice of laminations to make kitchen cabinet Shutter/ drawer front shutters in double panel including matching edge beading on exposed face of board edges complete as per specifications and as directed by the Engineer-in -charge.
Supply & Fixing 40mm continuous (piano) hinges, mild steel, bright finish or electro-galvanised complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing locks, cupboard, grade I, brass size 50 mm 2 lever and 2 keys fixed complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing stainless steel grade 304, 100 mm decorative type pressed handle fixing complete all as specified and directed by the Engineer-in-charge.
Material & Labour for 50 mm magnetic catches and fixed complete all as specified and directed by the Engineer-in-charge.
Material & Labour for injecting chemical Glyphosate (4% concentration) of 20 ml or till refusal by making cut/injection in the stem of plant or roots at 30mm and spraying with solution 25 ml Glyphosate (4% concentration diluted with 1 ltr of water) and removing the plant/vegetation complete all as specified and as directed by the Engineer-in-charge.
Material & Labour for providing and injecting chemical emulsion for post construction anti-termite treatment along the external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sqm of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete all as specified and directed by the Engineer-in-charge.
Material & Labour for providing and injecting chemical emulsion for post construction anti termite treatment along the external wall below concrete or masonary apron using chemical emulsion at 2.25 litre per linear meter including drilling and plugging holes etc with white cement and match the surface to existing apron complete all as specified and directed by the Engineer-in-charge.
Material & Labour for treatment of soil under existing floors in junction with wall (internally) using chemical emulsion @ 1 litre per hole at 300mm center to center and 300mm deep including drilling and plugging 12mm dia holes with cement mortar 1:2 or white cement to match the existing floors complete all as specified and directed by the Engineer-in-charge.
Material & Labour for post construction treatment of voids in masonry using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors all as specified and as directed by the Engineer-in-charge.
Material & Labour for post construction treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same with sealing compound complete all as specified and directed by Engineer-In-charge.
Material & Labour for providing precast cement concrete louvres and jallies, type B0 1:2:4 (using 12.5mm graded aggregate) 35mm thick (measured solid), including all mouldings but excluding frame set in cement mortar 1:4 complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing in repairs for 20mm dia curtain rods anodised alumininium alloy, powder coated with fixing brackets, stops, rollers, etc. complete all as specified and directed by the Engineer-in-charge.
Supply only approved SBR Latex polymer for bonding coat. Note: Rate shall be in terms of solid contents of polymer.
Internal Electric Supply
Material & Labour for taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition sepertately) and making good disturbed surfaces of walls, floors etc. Note: Serviceable tube lights etc shall be kept under safe custody and refixed as directed.
Material & Labour for taking down fan, sealing cable end, dismantling blades and removing fan and blades to store MES store yard.
Material & Labour for taking down old unserviceable MCB DBs including MCBs.
Material & Labour for point wiring complete with proper colour coding using, 1100 Volts grade, 1.5 Sqmm, PVC insulated FRLSH, unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked concealed wiring drawn in PVC conduit and including (minimum 20 mm dia) fixed under the surfaces of wall, ceiling etc with all accessories, fittings, PVC junction boxes etc, also including 1.5 Sqmm, PVC insulated, FRLSH, unsheathed, 1100 Volts multi stranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed: Note: In ceiling portion and in case of columns coming in way of concealed conduit, casing caping of suitable size shall be used. No extra cost shall be paid for the PVC casing capping item.
(a) One light point controlled by one switch
(b) One fan/exhaust fan point controlled by one switch
(c) One 3 pin socket outlet 5 amps on the same board with other switches
(d) One 3 pin socket outlet 5A controlled by switch on independent board
(e) One bell point controlled by one switch
(f) One light point controlled by two 2 way switch, complete
Material & Labour for point wiring using proper colour coding with 1100 Volts grade, 2.5 Sqmm PVC insulated, FRLSH, unsheathed, wire confirming to IS-694, Part-II, ISI marked with multistranded copper conductor concealed wiring drawn in PVC conduit and including (minimum 20 mm in dia) fixed under the surfaces of wall, ceiling etc with all accessories, fittings, PVC junction boxes etc, also including 2.5 Sqmm, PVC insulated, FRLSH, unsheathed, multistranded, copper conductor 1100 Volts grade, green color, continuous earth wire connected to common earth dolly for 15 Amps, 3 Pin, socket outlet independent complete all as specified and directed by the Engineer-in-charge. Note: (i) Modular Metal Flush Box, cover plate and frame shall be measured and paid separately. (ii) In ceiling portion and in case of columns coming in way of concealed conduit, casing caping of suitable size shall be used. No extra cost shall be paid for the PVC casing capping item.
Supply & Fixing Bell, AC, 230 Volts, Ding dong, ISI marked, single pole, complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing ISI marked Modular switch piano type 5 Amp single pole one way 1 Module complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing ISI marked Modular switch piano type 5 Amp single pole Two way 1 Module complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing ISI marked Modular switch piano type 15/20 Amp single pole one way 1 Module complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing ISI marked ceiling rose surface backelite, three terminal complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing ISI marked Modular bell push 5 Amp piano type single pole 230 volts one way 2 Module complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing ISI marked Modular socket outlet 2 in 1, 3/5 pin 5 Amps multipurpose flush type 2 Module complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing ISI marked Modular socket multipurpose 15 Amp ,2 in 1 , 5 pin flush type 2 Module complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing ISI marked Modular ceiling fan step type regulator,120 watt, socket type 230V,2 Module complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing Modular AC Box With 20A SP MCB, Metal Enclosure & Unbreakable Heavy Duty With ISI Plug Top complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing Modular White cover plate with frame 8 Module.
Supply & Fixing Modular White cover plate with frame 6 Module.
Supply & Fixing Modular White cover plate with frame 4 Module.
Supply & Fixing Modular White cover plate with frame 3 Module.
Supply & Fixing Modular White cover plate with frame 2 Module.
Supply & Fixing Rectangular GI Metal Flush Box 8 Module.
Supply & Fixing Rectangular GI Metal Flush Box 1 Module.
Supply & Fixing Metal Flush Box 6 Module.
Supply & Fixing Metal Flush Box 4 Module.
Supply & Fixing Metal Flush Box 3 Module.
Supply & Fixing Metal Flush Box 2 Module.
Supply & Fixing Metal Flush Box 1 Module.
Supply & Fixing Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings type 230 Volts AC 50 Hz.
Supply & Fixing LED Bulb 9/10 Watt 230 Volts AC 50 Hz complete all as specified.
Supply & Fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing LED indoor decorative aluminum extruded LED batten integrated type tube light fitting, suitable and including wattage 20W, rated input voltage 140V AC - 270V AC, driver efficiency 88%, Lumens efficiency 100 lm/W, starting voltage 90V, THD<=20, color rendering index (CRI) 0.80, color temperature 6500K, no harmful radiations, inbuilt surge protection 2.5 kV, isolation 3.75 kV, zero mercury content, complete with all accessories internally complete with all accessories internally prewired and including connected up with twin core twisted flexible copper conductor cable with suitable sizes complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing LED indoor decorative aluminum extruded LED batten integrated type tube light fitting, suitable and including wattage 10W, rated input voltage 140V AC - 270V AC, driver efficiency 88%, Lumens efficiency 100 lm/W, starting voltage 90V, THD<=20, color rendering index (CRI) 0.80, color temperature 6500K, no harmful radiations, inbuilt surge protection 2.5 kV, isolation 3.75 kV, zero mercury content, complete with all accessories internally complete with all accessories internally prewired and including connected up with twin core twisted flexible copper conductor cable with suitable sizes complete all as specified and directed by the Engineer-in-charge.
Taking down unserviceable building security light fitting and Supply and fixing pressure die cast housing with epoxy powder coated dark graphite grey colour finish. Prismatic polycarbonate cover with individual LED lenses IP65 35 watt, AC 240 Volts 50 HZ complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing MCB DB, 08 way, SPN, double door, 230 Volts, fixed concealed/ surfaces on the wall, making all connections, complete all as specified and directed by the Engineer-in-charge. Note: Quoted rate shall be deemed to include for provision of copper bus bar of 200 Amps rating complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing MCB, SPN 32 Amps rating, 10KA, ‘B” curve type, 230 Volt, and connecting the incoming and out going cables by using copper lugs pin type complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing MCB SP 6-32 Apms,’B’ curve type, 240 Volts complete all as specified and directed by the Engineer-in-charge.
Material & Labour for Taking down sub-main wiring and Supply & Fixing for sub main wiring complete with Two runs of 4 Sqmm single core PVC insulated unsheathed,heavy duty, 1100 Volt grade multistranded copper conductor cable (FRLS) and drawer through and including concealed PVC conduit (minimum 25 mm dia) under the surfaces of the walls etc with all accessories, fittings etc and including one run of PVC insulated and unshethed copper conductor 4.00 Sqmm single core cable (FRLS) as earth continuity conductor, connected with earth dolly and mains all as specified & directed. Note: Three run of 4 Sqmm PVC cable and one run of PVC conduit will be measured as one unit length (AC Connection). Note: In ceiling portion and in case of columns coming in way of concealed conduit, casing caping of suitable size shall be used. No extra cost shall be paid for the PVC casing capping item.
Material & Labour for Taking down submain wiring and Supply & Fixing for sub main wiring complete with Two runs of 6 Sqmm single core PVC insulated unsheathed,heavy duty, 1100 Volt grade multistranded copper conductor cable (FRLS) and drawer through and including concealed PVC conduit (minimum 25 mm dia) under the surfaces of the walls etc with all accessories, fittings etc and including one run of PVC insulated and unshethed copper conductor 6.00 Sqmm single core cable (FRLS) as earth continuity conductor, connected with earth dolly and mains all as specified & directed. Note: Three run of 6 Sqmm PVC cable and one run of PVC conduit will be measured as one unit length.(From Meter to Room DB). Note: In ceiling portion and in case of columns coming in way of concealed conduit, casing caping of suitable size shall be used. No extra cost shall be paid for the PVC casing capping item.
Disconnecting the incoming and out going cable connection and dismantling the unserviceable conventional type industrial meter board and removing from site for further disposal. Design fabricating supplying and fixing indoor type horizontal panel for 08 nos smart prepaid meter of tentative size 160mm x 262mm x 99mm mounting, vermin and weather proof totally inclosed cubical type front operated double door seperate compartment with transparent acrylic sheet for taking meter reading, fabricated out of minimum 2 mm thick CRCA sheet duly treated with seven tank process and painted epoxy powder coated siemens grey colour and with industrial type built in locking arrangement. The meter box shall be factory made from a reputed pannel fabricators (CPRI approved manufacturers). The panel shall be wall/floor mounting type and to be fixed with all necessary fixing arrangements such as angle iron brackets and frame or iron angles 3 mm thick. The panel to be pre-wired with PVC insulated copper conductors for monitors and Copper busbar with heat shrinkable sleeves of capacity 200Amps for connecting the incoming MCCB and out going MCB and including digital type multifuction meter with the following items complete all as specified (Meter panel)
(a) Copper busbar 200 Amps for phases and neutral duly sleeved with heat shrinkable insulation using colour code for R Y B &N set of 4- 01 Set. (b) MCCB, TPN, 100 Amps 415 Volts 16 KA- 01 No incomer) (c) MCB SPN, 32 A, 230 Volt, 10KA, ‘B’ curve -08 Nos (out going) (d) MCB,SP, 6 A, 230 Volt, 10KA,‘B’ curve -01 Nos (out going) (e) Indicator lamp complete with lamp holder LED type set of 03-01 set (g) VAF+ PF meter CL-0.5, input Voltage-50-520 VAC, CT 1A/5 A, Parameter VLL,VLN,A, F& PF digital type meter of size 96mm x 96mm - 01 No
M&L including taking down existing earthing and in lieu M&L for new earthing complete with galvanized earth plate electode 600 x 600 x 6mm thick buried directly in ground, earth pit not less than 2.25 meters deep below ground level, connected to and including galvanised earth wire 4mm dia to the extent upto 7.5 metre as earth lead by means of bolts, nuts etc, with provision of charcoal and salt all as per electrical plate No 5 of SSR Part I, including water arrangement with GI pipe 20mm bore (medium grade), earth lead protection pipe 15mm bore light grade with bends, elbow etc. from earth plate to test point, excavation and earth work, returning, filling, ramming and removing of soil to a distance not exc 50 metre, making PCC 1:2:4 type B-1 pit (Earth chamber) with RCC 1:2:4 cover 50mm thick reinforced with XPM and testing on completion including making test point on wall as per SSR specifications complete all as specified and directed by the Engineer-in-charge. (Note: Cost of GI earth wire and protection pipe upto 7.5 metre shall also be deemed to be included in the quoted rate)
Supply & Fixing Exhaust Fan 300 mm sweep 900 RPM Metal body single phase 230 Volts complete all as specified and directed by the Engineer-in-charge. Note:- Making of Holes in wall of exhaust fan shall be included in above quoated rates( Kitchen)
Road /Path
Material & Labour for 100 mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base floor / pavings complete all as specified and directed by the Engineer-in-charge.
Material & Labour for coloured glazed chequered liquid glossy finish cement concrete tiles 30cm x 30cm x 25cm thick With mixture of grey and white cement in equal proportions and no pigment set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles complete all as specified and directed by the Engineer-in-charge.
Material & Labour for screed bed or bedding layer of mortar, 20 mm thick, in cement mortar 1:6, for laying floor finishes/tiles complete all as specified and directed by the Engineer-in-charge.
Material & Labour for Machine pressed (LAQUER FINISH) cement concrete factory made coloured glazed interlocking paver block any shape and size confirming to IS 15658 -2006 of 60mm thickness, M-35 Grade, machine pressed of pattern and colour as approved by GE set with gray cement and no pigment complete all as specified and directed by the Engineer-in-charge.
Material & Labour sand filling under floors or in foundation including watering and consolidation complete all as specified and directed by the Engineer-in-charge.
External Water Supply
Supply and lay pipe in repair galvanized, “Medium class”, 40 mm dia. including fittings complete all as specified and directed by the Engineer-in-charge.
Supply and lay pipe galvanized, “Medium class”, 25 mm bore including fittings all as specified and directed ( Branch pipe from 40mm riser to PVC tank )
Supply and lay pipe galvanized, “Medium class”, 20 mm including fittings all as specified and directed bore (Branch pipe from 40mm riser to PVC tank )
Supply & Fixing in repair gun metal gate valve with ISI marked iron wheel head of size 40 mm with external threaded both ends for connecting to pipe line including complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing in repair gun metal gate valve with ISI marked iron wheel head of size 25mm with external threaded both ends for connecting to pipe line including complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing Float valves of 25mm dia, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing Float valves of 20mm dia, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and directed by the Engineer-in-charge.
Excavation in trenches n.exc 1.5 m wide and n. exc 1.5 m in depth and getting out in soft/loose soil for removing/laying of cables complete all as specified and as directed by Engineer-in-charge.
Returning, filling including spreading , leveling , watering and well ramming in layers n.exc 25 cm complete all as specified and as directed by the Engineer-in-charge
Removing excavated material (any type) and disposing it outside Ministry of Defence Land complete all as specified and directed by the Engineer-in-charge. Note: (i) Before quoting the tender, the bidders are advised to ascertain the distance outside MD and at which the excavated material/ debris are to be disposed off. No extra claim what-so ever shall be entertained on this account. (ii) This item shall be considered as per the requirement at site.
MUKESH CONSTRUCTION CO (BID ID -3071629)
S. C. Mangla and Co. (BID ID -3072230)
Vishal Builders (BID ID -3063449)
PMR CONSTRUCTIONS (BID ID -3072294)
Parmatma Enterprises (BID ID -3071187)
Star Construction Co. (BID ID -3063819)
haresh n hingorani (BID ID -3055965)
Joy builders (BID ID -3063261)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .