Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.6 LAccepted-AOC | ₹9.6 L Quoted ₹9.7 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹10.0 L+₹32,450 (3.36%)Rejected-Finance | ₹10.0 L+₹32,450 (3.36%) | L2 | Rejected-Finance Not being for lowest |
| 3 | L3₹10.4 L+₹74,100 (7.67%)Rejected-Finance | ₹10.4 L+₹74,100 (7.67%) | L3 | Rejected-Finance Not being for lowest |
| 4 | L4₹10.6 L+₹88,750 (9.18%)Rejected-Finance | ₹10.6 L+₹88,750 (9.18%) | L4 | Rejected-Finance Not being for lowest |
| 5 | L5₹10.6 L+₹94,545 (9.78%)Rejected-Finance 02 JAMEEWAR COMPLEX RING ROAD HANUMAN NAGAR GONDIA MAHARASHTRA 441614 | GONDIA | MAHARASHTRA | 441614 | ₹10.6 L+₹94,545 (9.78%) | L5 | Rejected-Finance Not being for lowest |
| Sl No | Description | Qty | Unit | ANSARI REFRIGERATION L7 | M/S R S Traders L5 | HIMANSHU TRADERS L3 | Krishna Enterprises L8 | M/S VIJAY SINGH L6 | OASIS CONTRACTORS BUILDERS & SUPPLIERS L2 | YOU SEE CONSTRUCTION L4 | M/S A M ENTERPRISES L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for Servecing cleaning / soldering to leakage portion of geyser (water heater) in any specifications/ cap/ make/model etc after opening body chemical disclearing to all vest matrials of water heating unit, heating element ,water storage tank , inlet/ out let pipe etc all including replacement of minor spare such as indication lamp, top plug, inter connection pipe etc other required minor spare (if required), mounting bolt titing / fixing properly for making functional properly included re-assembling/ fixing and re-connected as per existed etc all as directed. Note: . 1. Quotated rate shall be included cost of taking down and refixing the same. | 300 | Job | 500 ₹1,50,000 | 458 ₹1,37,400 | 500 ₹1,50,000 | 450 ₹1,35,000 | 461 ₹1,38,300 | 400 ₹1,20,000 Lowest | 450 ₹1,35,000 | 400 ₹1,20,000 Lowest |
| 2.00 | Supply and fixing in replacement to copper base plate assmebly with inlet and outlet pipe with packing, nuts, bolts and washer suitable for 25 Ltrs storage capacity. Note- 1.Quotated rate shall be included cost of taking down and refixing the same. | 50 | Each | 300 ₹15,000 Lowest | 595 ₹29,750 | 750 ₹37,500 | 750 ₹37,500 | 761 ₹38,050 | 730 ₹36,500 | 750 ₹37,500 | 750 ₹37,500 |
| 3.00 | Supply and fixing in replacement to copper base plate assmebly with inlet and outlet pipe with packing, nuts, bolts and washer suitable for 50 Ltrs storage capacity. Note- 1.Quotated rate shall be included cost of taking down anf refixing the same. | 15 | Each | 400 ₹6,000 Lowest | 625 ₹9,375 | 750 ₹11,250 | 750 ₹11,250 | 761 ₹11,415 | 752 ₹11,280 | 750 ₹11,250 | 750 ₹11,250 |
| 4.00 | Supply & fixing in position indicating lamp for geysers rectangular /round type complete as directed by Engineer-in-Charge. | 80 | Each | 50 ₹4,000 Lowest | 140 ₹11,200 | 80 ₹6,400 | 80 ₹6,400 | 89 ₹7,120 | 90 ₹7,200 | 80 ₹6,400 | 80 ₹6,400 |
| 5.00 | Supply and fixing in replacement to water heating element for 1.5 KW capacity in round / angular/triangle shape with packing complete . Note- 1.Quotated rate shall be included cost of taking down and refixing the same. | 100 | Each | 450 ₹45,000 Lowest | 820 ₹82,000 | 850 ₹85,000 | 780 ₹78,000 | 950 ₹95,000 | 900 ₹90,000 | 950 ₹95,000 | 900 ₹90,000 |
| 6.00 | Supply and fixing in replacement to water heating element for 2 KW in round / angular/triangle shape with packing gas cut complete. Note- 1.Quotated rate shall be included cost of taking down anf refixing the same. | 20 | Each | 1,200 ₹24,000 | 800 ₹16,000 | 800 ₹16,000 | 750 ₹15,000 Lowest | 890 ₹17,800 | 905 ₹18,100 | 890 ₹17,800 | 920 ₹18,400 |
| 7.00 | Supply and fixing in replacement to water heating element for 3 KW capacity in round / angular shape with packing gas cutt complete. Make : Balisco/ Roxy/ Bajaj/ Theta Note- 1.Quotated rate shall be included cost of taking down anf refixing the same. | 10 | Each | 2,200 ₹22,000 | 830 ₹8,300 | 850 ₹8,500 | 750 ₹7,500 Lowest | 900 ₹9,000 | 905 ₹9,050 | 900 ₹9,000 | 950 ₹9,500 |
| 8.00 | Supply and fixing in replacement to water storage copper tank cap 25 Lts with all tech specification as per existed complete. Note- 1.Quotated rate shall be included cost of taking down and refixing the same. | 50 | Each | 1,500 ₹75,000 | 1,320 ₹66,000 Lowest | 1,600 ₹80,000 | 1,600 ₹80,000 | 2,100 ₹1,05,000 | 1,800 ₹90,000 | 2,100 ₹1,05,000 | 2,000 ₹1,00,000 |
| 9.00 | Supply and fixing in replacement to water storage copper tank cap 50 Lts with all tech specification as per existed complete.Note- 1.Quotated rate shall be included cost of taking down and refixing the same. | 12 | Each | 1,800 ₹21,600 | 1,360 ₹16,320 Lowest | 1,800 ₹21,600 | 1,700 ₹20,400 | 2,000 ₹24,000 | 2,100 ₹25,200 | 2,000 ₹24,000 | 2,400 ₹28,800 |
| 10.00 | Supply and fixing in replacement to thermostate asssembly manually adjustment type setting range with 35 to 100 CC for fixing upto 50 Ltrs capacity. | 150 | Each | 250 ₹37,500 | 232 ₹34,800 Lowest | 340 ₹51,000 | 290 ₹43,500 | 375 ₹56,250 | 340 ₹51,000 | 375 ₹56,250 | 350 ₹52,500 |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
10 Aug 2026, 6:00 pmClosed
AGE (I) AF Manauri
AGE (I) AF Manauri
REPAIR/MAINT OF ELECTRIC WATER HEATER APPLIANCES AT 24 ED UNDER AGE (I) AF MANAURI
2026_MES_769315_2
8000/40/E8
Open Tender
Civil Works
Item Rate
270 days
Manauri Prayagraj
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE (I) AF MANAURI
₹19,000
Yes
11 Sept 2026
27 Jul 2026
12 Aug 2026
27 Jul 2026
10 Aug 2026
3 Aug 2026
27 Jul 2026 - 31 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for Servecing cleaning / soldering to leakage portion of geyser (water heater) in any specifications/ cap/ make/model etc after opening body chemical disclearing to all vest matrials of water heating unit, heating element ,water storage tank , inlet/ out let pipe etc all including replacement of minor spare such as indication lamp, top plug, inter connection pipe etc other required minor spare (if required), mounting bolt titing / fixing properly for making functional properly included re-assembling/ fixing and re-connected as per existed etc all as directed. Note: . 1. Quotated rate shall be included cost of taking down and refixing the same. | 300 | Job | - | - |
| 2 | Supply and fixing in replacement to copper base plate assmebly with inlet and outlet pipe with packing, nuts, bolts and washer suitable for 25 Ltrs storage capacity. Note- 1.Quotated rate shall be included cost of taking down and refixing the same. | 50 | Each | - | - |
| 3 | Supply and fixing in replacement to copper base plate assmebly with inlet and outlet pipe with packing, nuts, bolts and washer suitable for 50 Ltrs storage capacity. Note- 1.Quotated rate shall be included cost of taking down anf refixing the same. | 15 | Each | - | - |
| 4 | Supply & fixing in position indicating lamp for geysers rectangular /round type complete as directed by Engineer-in-Charge. | 80 | Each | - | - |
| 5 | Supply and fixing in replacement to water heating element for 1.5 KW capacity in round / angular/triangle shape with packing complete . Note- 1.Quotated rate shall be included cost of taking down and refixing the same. | 100 | Each | - | - |
| 6 | Supply and fixing in replacement to water heating element for 2 KW in round / angular/triangle shape with packing gas cut complete. Note- 1.Quotated rate shall be included cost of taking down anf refixing the same. | 20 | Each | - | - |
| 7 | Supply and fixing in replacement to water heating element for 3 KW capacity in round / angular shape with packing gas cutt complete. Make : Balisco/ Roxy/ Bajaj/ Theta Note- 1.Quotated rate shall be included cost of taking down anf refixing the same. | 10 | Each | - | - |
| 8 | Supply and fixing in replacement to water storage copper tank cap 25 Lts with all tech specification as per existed complete. Note- 1.Quotated rate shall be included cost of taking down and refixing the same. | 50 | Each | - | - |
| 9 | Supply and fixing in replacement to water storage copper tank cap 50 Lts with all tech specification as per existed complete.Note- 1.Quotated rate shall be included cost of taking down and refixing the same. | 12 | Each | - | - |
| 10 | Supply and fixing in replacement to thermostate asssembly manually adjustment type setting range with 35 to 100 CC for fixing upto 50 Ltrs capacity. | 150 | Each | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.66 MB
Tender40.pdf
Tender Documents • 1.11 MB
BOQ_875073.xls
BOQ • 0.31 MB
LISTOFMAKE40.pdf
Additional Documents • 0.96 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .