Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹49.1 L+₹87,980.30 (1.82%)Rejected-Finance AWADHI ROAD ADAJAN 1ST 102 DABKA NO 1 1 6 4 C 4TH FLOOR | GANDHINAGAR | L2 | Rejected-Finance Other than lowest. | |
| 3 | L3₹49.9 L+₹1.7 L (3.42%)Rejected-Finance VILL CHOMON ADAMPUR JALANDHAR PUNJAB 144103 UDYAM PB 10 0011450 | JALANDHAR | PUNJAB | 144103 | L3 | Rejected-Finance Other than lowest. | |
| 4 | L4₹50.3 L+₹2.0 L (4.24%)Rejected-Finance | L4 | Rejected-Finance Other than lowest. | |
| 5 | L5₹50.5 L+₹2.2 L (4.64%)Rejected-Finance NEAR RAILWAY CROSSING ADAMPUR DOABA JALANDHAR JALANDHAR PUNJAB 144103 | JALANDHAR | PUNJAB | 144103 | L5 | Rejected-Finance Other than lowest. |
Tender Value
Refer Docs
EMD Value
₹91,400
Closing Date
16 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Adampur
Military Engineer Services AF Stn Adampur 144103
PROVN OF CERTAIN SANCTIONED WORKS IN TECH AREA AT AF STN ADAMPUR
2023_MES_614674_2
GE/AF/ADM-30/2023-24
Open Tender
Civil Works
Item Rate
180 days
Tech area at AF Stn Adampur
Refer NIT and Tender Documents
8 documents required · 8 mandatory
₹500
GE AF Adampur
₹91,400
Yes
21 Dec 2023
1 Nov 2023
17 Nov 2023
1 Nov 2023
16 Nov 2023
2 Nov 2023
Amount
BR WORKS
Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete, all as specified.
Excavation over areas in soft/loose soil not exceeding 1.50 metre deep and getting out complete, all as specified.
Excavation over areas in soft/loose soil exceeding 1.50 metre but not exceeding 3.00 metre deep and getting out complete, all as specified.
Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for foundation, etc. and getting out complete, all as specified.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface in soft/loose soil complete, all as specified.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each, complete, all as specified.
Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified.
Broken bricks hardcore of gauge 80 to 150 mm, loose filling in soakage pits, soakage wells complete, all as specified.
PCC type C-2 (1:3:6), using 40 mm graded stone aggregates as in filling & mass concrete, complete all as specified.
PCC type C-2 (1:3:6), using 20 mm graded stone aggregates in surface channels and drains complete all as specified.
PCC type C-2 (1:3:6), using 40 mm graded stone aggregates in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified.
Cement concrete, type B-1 (1:2:4), using 20 mm graded stone aggregates as in lintels up to 1.5 metre clear span, bed blocks, copings and the like including weathering, slightly rounded or chamfered angles & throating including provision of necessary formwork, complete all as specified.
Precast RCC type B-1 (1:2:4), using 20 mm graded stone aggregates landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including all mouldings but excluding frame, set in cement mortar (1:4) complete all as specified.
Reinforced cement concrete type B-1 (1:2:4), using 20 mm graded stone aggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified.
Brick work using bricks as specified in PS-II clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), complete all as specified.
Brick work using bricks as specified in PS-II clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:4), complete all as specified.
Brickwork with sub-class `B’ bricks in one brick thick honey comb walling built in built in cement mortar (1:3), complete all as specified.
Cutting openings, through brick walls, built in cement mortar for door, window & other openings or enlarging existing openings, converting window into door openings, etc. or cutting out defective bk wk for under-pinning, including providing, fixing & removing shoring, cleaning & stacking bricks, removing surplus serviceable bricks, hardcore, etc., to store & rubbish not exc. 50 m, complete all as specified.
Use & waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) with rough finished surfaces of concrete, complete all as specified.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs and sides of RCC/PCC bands in walls, horizontal or sloping and similar work n exc 10 cm wide complete, all as specified.
Factory made, flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, 30 mm thick, ISI marked, complete all as specified.
Solid PVC wall lining consisting of 5mm thick single side prelam PVC sheet inclusive of solvent cement and fixing at site on PVC frame, PVC strip etc fixing as wall panelling, complete all as specified.
5 mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC framecomplete all as specified.
Aluminium anodised barrel tower bolt of extruded section 150 mm long, ISI marked, complete all as specified.
Aluminium alloy, anodised, ISI marked sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy 250 mm long, complete all as specified.
Double leg aluminium anodised door stopper with rubber foot, ISI marked and fixed to bottom rail of doors with steel screws, complete.
Mild steel works in hand rails, half round or other stock section or core for wooden handrail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) in-cluding all necessary drilling, bolting or riveting, etc., confirming to Fe-290-Gde E-165, complete all as specified.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
Mild steel TMT bars 5 mm and over up to and including 10 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips in stirrups, spacers and binders complete all as specified.
Rolled mild steel as in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, quality confirming to grade Fe-290-Gde E-165, complete all as specified.
Mild steel rolled sections as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming to grade Fe-290-Gde E-165, complete all as specified.
Rolled mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240, complete all as specified.
Steel rolling shutters, gear operated type with bevel gear box and crank handle, as specified including top cover, anchoring rod, hasp and staple; erected in position as in-dicated, with thickness of lath as 1 mm, complete all as specified.
Factory made pre painted pressed steel frames, conforming to IS, having profile 125 mm x 60 mm for doors with one or more rebates made out of 1.25 mm thick mild steel sheet, including necessary fixing lugs, butt hinges, lock strike plate, etc., duly filled with PCC(1:3:6) type C-0 complete, all as specified.
Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
Powder coated aluminium door shutters with styles & rails made out of section size 83-85 mm x 44-45 mm (wall thickness not less than 2 mm) , anodised alumnium glazing snap beading (having wall thickness not less than 0.90 mm), rubber neoprene packing including joining cleats & screws etc as per manufacturers instructions, complete all as specified. NOTES: (a) Each shutter shall have 2 Nos. 200 mm long almn handles and 03 No. 100 mm size stainless steel/almn butt hinges. (b) Glass and other filling materials in panels including wire cloth and almn grill shall be measured & paid for separately under respective item of BoQ. (c) For powder coated aluminum sections minimum thickness of powder coating shall be 50 micron.
Powder coated aluminium window and ventilator shutters side hung type with styles & rails made out of section size 47-48 mm x 44-45 mm (wall thickness not less than 1.58 mm), anodised alumnium glazing snap beading (having wall thickness not less than 0.90 mm), rubber neoprene packing including joining cleats & screws etc as per manufacturers instructions, complete all as specified. NOTES: (a) Each shutter shall have 2 Nos. 125 mm long almn handles and 02 No. 75 mm size stainless steel/almn butt hinges & one no. almn hook & eye. (b) Glass and other filling materials in panels including wire cloth and almn grill shall be measured & paid for separately under respective item of BoQ. (c) For powder coated aluminum sections minimum thickness of powder coating shall be 50 micron.
Powder coated aluminium grill type DG-117 including necessary 'U' clip & screws etc as per manufacturers instructions, complete all as specified.
Plain tinted sheet glass, 5-6 mm thick, ordinary quality and fixed air tight with neoprene packing & almn glazing clips, for aluminium sections, complete all as specified. NOTE: Almn glazing clips & neoprene packing will be measured & paid for under respective item of aluminium door/windows/partition.
Aluminium composite panel sheet 4-5 mm thick, of shade approved by GE, cut to shape and fixed in position as almn door shutter panels/partition, complete all as specified.
Powder coated GI snap grid frame work of size 605mm x 605mm for false ceiling complete with acessories all as specified and shown on serial page No.186 of MES Schedule Part-II.
4 mm thick E-board, multipurpose, decorative type fixed in grid frme work ceilings as panels, complete all as specified.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm of any colour hving tensile strength of 550 Mpa as in roof coverng/ cladding to wall, fixed with self tapping screws comlete all as specified.
Taking down existing water proofing treatment (any no. of layers) from RCC roofs including cleaning the surface including flashings and junction of parapet etc. with wire brushing & water to the entire satisfaction of EIC, complete all as specified.
APP based polymeric membrane 3 mm thick, laid on primed roofs & flashing by forced application using Butane torch and sealing all joints on primed surface by applying hot blown industrial grade bitumen @ 85/25 @ 1.20 kg/Sq.m over a coat of bitumenous primer @ 0.40 litre per square metre over clean RCC/plastered roof surfaces & flashings complete, all as specified.
Cutting out cracks to V-section in existing roofs or terracing up to 25 mm depth, cleaning out, and filling solidly with a tarplastic sealing comound after applying primer, complete all as specified.
25 mm thick, cement concrete type B-0, 1:2:4 using 20 mm graded stone aggregate, finished even & rough, as in sub floors, complete all as specified.
50 mm thick, cement concrete type B-1, 1:2:4 using 20 mm graded stone aggregate, finished even & rough, as in sub floors, complete all as specified.
75 mm thick, cement concrete type C-1, 1:3:6 using 20 mm graded stone aggregate, finished even & smooth without using extra cement, as in plinth protection, and joints shall be sealed with joint sealing comound grade 'A' complete all as specified.
75 mm thick, cement concrete type D-2, 1:4:8 using 40 mm graded stone aggregate, finished even & rough, as in sub floors, complete all as specified.
100 mm thick, cement concrete type D-2, 1:4:8 using 40 mm graded stone aggregate, finished even & rough, as in sub floors, complete all as specified.
Machine cut Kota stone slab flooring 18-22 mm thick, area of each slab not less than 0.30 sq.m, (cut to size in square shape) laid over & including 20 mm thick (average thickness) cement mortar (1:3) screed and jointed with grey cement slurry mixed with matching shade pigment including rubbing and polishing (Granite finish) complete, all as specified.
Granite jet black shade, 15-18 mm thick,as in step, jambs, cooking platform and like, machine cut, machine polished, bedded and jointed with grey cement slurry & pointed with grout of matching shade including necessary cutting over & including 10 mm thick (average thickness) cement mortar (1:4), complete all as specified.
Rounding of / moulding to edges (half round) of stone of any description including rubbing and polishing (Granite finish), complete all as specified.
Glazed ceramic coloured tiles 7mm thick, area of each tile exc. 0.17 Sq.m but n. exc. 0.19 Sq.m on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed with grout of matching shade of tile laid over and including 10mm thick rendering in cement mortar (1:4), complete all as specified.
Non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exc. 0.06 Sq.m but n. exc. 0.11 Sq.m laid in floors etc, set and jointed in neat cement slurry and pointed with grout of matching shade of tile laid over and including 15 mm thick bedding layer in cement mortar (1:4) complete all as specified.
Endura vitrified paving coloured tiles 9 to 10mm thick (square/ rectangular) area of each tile exc. 0.11 Sq.m but n. exc. 0.18 Sq.m laid in floors etc, set and jointed in neat cement slurry and pointed with grout of matching shade of tile laid over and including 15 mm thick bedding layer in cement mortar (1:4) complete all as specified.
80 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of shape approved by GE, made by table vibratory method using PU mould, laid in required pattern over and including 50 mm thick compacted bed of coarse sand, compacting through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete.
Linoleum sheet, plain coloured, 4.50 mm thick, laid in floors with an approved adhesive including stretching, cutting and fitting, sealed down, complete all as specified.
Cement concrete work in pavement/hard-standing of flexural strength 45 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 300 mm or less including use & waste of side forms, over & including a layer of fine sand 25 mm thickness, complete all as specified.
Laying 400 micron HDPE polythene film including all necessary cutting & overlapping after applying evenly a tack coat of industrial bitumen VG-10 @ 2.5 kg per sq. m complete all as specified.
Forming construction/dummy joints 8 mm wide and 110 mm deep, using diamond cutter machine complete all as specified comprising the following: - (i) Cleaning the surfaces intialy with wire/coir brushes and thereafter with compressed air by using compressor to the entire satisfaction of Engineer-in-Charge. (ii) Insert a bond breaker tape and bond breaker [closed cell polyethylene frame rod 10 mm dia] caulked tightly into the base of the sealing groove to prevent the sealant from adhering to the base of slot complete. (iii) Sealed flush the joint to a level of 2-3 mm below the top of the adjacent pavement using polyurethane joint sealent (minimum depth 12 mm) after priming the vertical surface twice @ 0.075 litre (minimum) primer per square metre complete.
Forming construction joints 8 mm wide and 25 mm deep, using diamond cutter machine complete all as specified comprising the following: - (i) Cleaning the surfaces intialy with wire/coir brushes and thereafter with compressed air by using compressor to the entire satisfaction of Engineer-in-Charge. (ii) Insert a bond breaker tape and bond breaker [closed cell polyethylene frame rod 10 mm dia] caulked tightly into the base of the sealing groove to prevent the sealant from adhering to the base of slot complete. (iii) Sealed flush the joint to a level of 2-3 mm below the top of the adjacent pavement using polyurethane joint sealent (minimum depth 12 mm) after priming the vertical surface twice @ 0.075 litre (minimum) primer per Sq.m.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:6) complete all as specified.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:4), mixed with water proofing compound as per manufacturers instructions, complete all as specified.
Supply only water proofing compound, ISI marked, complete all as specified.
Two coats of cement base paint on new plastered wall surfaces, including preparation of surfaces, complete all as specified.
Prepration of new plasterd wall surfaces of any description complete all as specified and applying the following: - (a) Applying wall care putty in two coats & smoothening the surfaces as specified. (preparatory to paint as directed). (b) Two coats of interior acrylic distemper/oil bound distemper over and including a coat of interior primer.
Prepration of new plasterd wall surfaces of height not exc 7.50 metre and applying the following: - (a) Applying wall care putty, in two coats & smoothening the surfaces as specified. (preparatory to paint as directed).complete all as specified. (b) Two coats of exterior acrylic emulson over and including a coat of water based exterior primer in disruptive/camouflaging pattern of four shades complete all as specified. NOTE: RGB value of four shades of disruptive/camouflaging pattern shall be all as shown on Drg No. GE/SK-1/19 sheet 1/2 & 2/2.
Plain sheet glass 4mm thick ordinary quality and glazing with oil putty or wooden beads in squares n. exc. 0.5 Sq.m in each pane complete all as specified.
Figured glass 4mm thick ordinary quality and glazing with oil putty in squares n. exc. 0.5 Sq.m in each pane complete all as specified.
Solar control reflective type film, having thickness not less than 25 micron sticked to glass panes, complete all as specified.
Two coats of synthetic enamel paint over & including a coat of pink primer over wood and wood based surfaces of any description not other wise described over 10cm width or girth including preparation of surfaces, complete all as specified.
Two coats of synthetic enamel paint over & including a coat of red oxide primer over steel or iron surfaces of any description not other wise described over 10cm width or girth including preparation of surfaces, complete all as specified.
500 litre capacity, white, three layered polyethylene water storage tanks (cylindrical vertical with threaded lid) including hoisted and fixed in position, making connections, complete all as specified including the following acessories: - (i) Gun metal ball valves, high pressure, with metal rod & high density plastic ball complete screwed for iron pipe or brass ferrule and fixed, suitable for 20 mm bore GI pipe, complete all as specified. (iii) Gun-metal stop valve (quarter turn type) with MS lever handle, suitable for 20 mm bore GI tubes, ISI marked, screwed both ends for iron pipe, complete all as specified. (iv) Provn of 20 mm bore GI light grade tube from O/H tank to nearest mouth of RWP, complete all as specified.
Steel tubes 15 mm bore ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors, complete all as speciifed.
Steel tubes 20 mm bore ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors, complete all as speciifed.
Angular stop valve/cock, cast copper alloy, chromium plated, with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, complete. MAKE: PRAYAG Cat No. 6510 or equivalent make mentioned in Appendix 'B'.
Concealed stop valve/cock, cast copper alloy, chromium plated, with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, complete. MAKE: PRAYAG Cat No. 6518 or equivalent make mentioned in Appndix 'B'.
Bib tap, cast copper alloy, chromium plated fancy type, long body with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, complete. (4+2) MAKE: PRAYAG Cat No. 6508 or equivalent make mentioned in Appendix 'B'.
Centre hole basin mixer, cast copper alloy chromium plated, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, complete. MAKE: PRAYAG Cat No. 6550 or equivalent make mentioned in Appendix 'B'.'.
Vitreous China wash down water closet pan (pedestal pattern), white ISI marked, including stainless steel body Jet spray (L-bend) with1.50 metre long braded tube tube, complete all as specified MAKE OF EWC: PRAYAG Cat No. 4016 or equivalent make mentioned in Appendix 'B'.
PVC water closet seat and white cover soft close type with & including mild steel chromium plated hinging device & rag bolts, complete all as specified. MAKE: PRAYAG Cat No. 723 or equivalent make mentioned in Appndix 'B'
Vitreous China wash basin, white, flat back, size 550 x 400 mm, ISI marked, including fixing acessories like rag bolts etc. with CP waste coupling half or full threaded suitable for & including 32 mm size PVC solid waste pipe, complete all as specified. MAKE: PRAYAG Cat No. 4645 or equivalent make mentioned in Appendix 'B'
Health faust with 1 metre SS tube & hook complete. MAKE OF URINAL: PRAYAG Cat No. BEA-97 or equivalent make mentioned in Appendix 'B'.
PVC flushing cistern 10 litre capacity, syphonic action type, any shade, dual flush, ISI marked with flush pipe and all fixing acessories, complete. MAKE: PRAYAG Cat No. 502 or equivalent make mentioned in Appendix 'B'
125mm size overhead ABS shower with cast copper alloy chromium plated arm 225 mm long with flange and fixed in position, IN REPAIRS, complete. MAKE: PRAYAG Cat No. BS-76 or equivalent make mentioned in Appndix 'B'.
Glass shelf 500x125 mm with brass brackets and fixed to wall with chromium plated brass screws and rawl plugs, complete. MAKE: PRAYAG Cat No. BEA-45 or equivalent make mentioned in Appendix 'B'.
Brass chromium plated towel rail 500-600 mm long, fixed to wall with SS screws and PVC rawl plugs, complete. MAKE: PRAYAG Cat No. BA-10 or equivalent make mentioned in Appndix 'B'.
Stainless steel soap dish, fixed to wall with SS screws and PVC rawl plugs, complete. MAKE: PRAYAG Cat No. BA-15S or equivalent make mentioned in Appendix 'B'.
Stainless steel round slotted grating with frame, 125-130 mm size fixed in position with cement joints, complete all as specified.
PVC connections 15 mm size of length 600 mm with PTMT nuts, complete all as specified.
Stainless steel peg set of six, fixed to wall with SS screws and PVC rawl plugs, complete. MAKE: PRAYAG Cat No. BEA-30 or equivalent make mentioned in Appendix 'B'.
Stainless steel (SS-304) sink made out of 1 mm thick sheet for kitchen or laboratory with plug waste pipe washers including cantilever cast iron brackets connecting union etc overall size 510mm x 430mm x 203mm with bowl size 430mm x 380mm x 203mm complete all as specified MAKE: PRAYAG Cat No.1318D or equivalent make mentioned in Appndix 'B'.
uPVC pipes 75 mm external dia, type-B, ISI marked (IS:13592) single socketed in any length with rubber ring joints, fixed under floors/walls as SWR pipes, complete all as specified.
uPVC pipes 110 mm external dia, type-B, ISI marked (IS:13592) single socketed in any length with rubber ring joints, fixed under floors/walls as SWR pipes, complete all as specified.
uPVC/PVC bend any radius, suitable for uPVC soil waste discharge pipes 75 mm external dia, complete all as specified,
uPVC/PVC bend any radius, suitable for uPVC soil waste discharge pipes 110 mm external dia, complete all as specified,
uPVC/PVC vent cowl 75-110 mm external dia, complete all as specified.
uPVC floor trap, suitable for uPVC soil waste discharge pipes 75 mm ext dia, complete all as specified,
Concrete bed to drain pipes 150 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; in Cement concrete 1:3:6 type C-2, complete all as specified.
Reinforced concrete pipes 150 mm bore, class NP-2, laid and jointed complete with collars, laid in trenches and jointed, ISI marked, complete all as specified.
EM WORKS
Point wiring with multi-stranded copper conductor, single core, PVC insulated and unsheathed FRLSH cable, including PVC insulated unsheathed stranded copper conductor single core FRLSH cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes with 3 mm thick plastic laminated sheet cover having necessary cutting for fixing switches/ sockets comprising the following: -
One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
One Socket outlet three pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified.
One socket outlet three pin, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
One socket outlet three pin, 6/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
NOTES: (a) Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule 'A'. (b) GI boxes shall be fixed flush to walls in position with cement mortar (1:4) complete all as directed. (c) Conduit shall be laid on surface in case of RCC ceiling surfaces.
Point wiring with multi-stranded copper conductor, single core, PVC insulated and unsheathed FRLSH cable, including PVC insulated unsheathed stranded copper conductor single core FRLSH cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes with base frame & cover plate suitable (for fixing modular switch/sockets) comprising the following: -
One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
One Socket outlet three pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified.
One socket outlet three pin, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
One socket outlet three pin, 6/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
NOTES: (a) Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule 'A'. (b) GI boxes shall be fixed flush to walls in position with cement mortar (1:4) complete all as directed. (c) Conduit shall be laid on surface in case of RCC ceiling surfaces.
Switch piano flush button single pole one way, 6 Amp complete all as specified.
Switch piano flush button single pole one way, 16 Amp complete all as specified.
Socket outlet multipurpose having provision for 2&3 pin, 6 Amp, flush type, complete all as specified.
Socket outlet multipurpose having provision for two-in-one 3 pin 6 Amp & 3 pin 16 Amp, flush type complete, all as specified.
Fan regulator (electronic) suitable for 48”/56” sweep fan, step type, single phase, complete all as specified.
Switch modular type single pole one way, 6 Amp, complete all as specified.
Switch modular type single pole one way, 16 Amp,complete all as specified.
Socket outlet modular type multipurpose having provision for 2&3 pin, 6 Amp, complete all as specified.
Socket outlet modular type multipurpose having provision for two-in-one 3 pin 6 Amp & 3 pin 16 Amp, complete all as specified.
Fan regulator modular type (electronic) suitable for 48”/56” sweep fan, step type, two module, complete all as specified.
Ceiling rose, surface bakelite, 65 x 50mm, three terminals complete, all as specified.
Lamp (angle) holder, insulated body, cord grip pattern, complete, all as specified.
Sub main wiring (with approved colour coding as per IS) with single core FRLS PVC insulated multi stranded copper conductor 1.1 KV grade (main cable: number of runs as indicated below along with single core FRLS PVC insulated multi stranded copper conductor 1.1 KV grade for earthing in conduits, complete all as specified for the following: -
2 runs of 4 Sq. mm main cable + 1 run of 4 Sq. mm earth cable
2 runs of 6 Sq. mm main cable + 1 run of 6 Sq. mm earth cable
2 runs of 10 Sq. mm main cable + 1 run of 10 Sq. mm earth cable
3 runs of 10 Sq. mm main cable + 2 run of 10 Sq. mm earth cable
NOTES: (i) Conduit & conduit accessories shall be measured & paid for separately. (ii) For payment purposes, total runs of main cable (each run of one running metre) as mentioned above and total run ( one running metre) of earth cable shall be considered together as "1 RUNNING METRE"
Rigid non metallic, PVC concealed conduit, 25 mm bore, medium grade, ISI marked, inclusive of all fitings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing acessories such as couplers, lock nuts, saddles, pipe hook etc. for sub main wiring or the like complete all as specified.
Rigid non metallic, PVC concealed conduit, 25 mm bore, heavy grade, ISI marked, inclusive of all fitings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing acessories such as couplers, lock nuts, saddles, pipe hook etc. for sub main wiring or the like complete all as specified.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 240 volt, breaking capacity not less than 10 kA, complete all as specified.
Sheet metal enclosure for DB for fixing MCB’s, isolators etc., having IP-43 protection, SPN, 4 way with 200 Amp rated bus bar, 240 V, double door type, surface and flush mounting, complete all as specified.
Sheet metal enclosure for DB for fixing MCB’s, isolators etc., having IP-43 protection, SPN, 8 way with 200 Amp rated bus bar, 240 V, double door type, surface and flush mounting, complete all as specified.
Sheet metal enclosure for DB for fixing MCB’s, isolators etc., having IP-43 protection, SPN, 12 way with 200 Amp rated bus bar, 240 V, double door type, surface and flush mounting, complete all as specified.
Sheet metal enclosure for DB for fixing MCB’s, isolators etc., having IP-43 protection, TPN, 4 way with 200 Amp rated bus bar, 415 V, with and including MCCB 4 pole 63 Amp, 16kA., double door type, surface and flush mounting, complete all as specified.
Sheet metal enclosure for DB for fixing MCB’s, isolators etc., having IP-43 protection, VTPN, 4 way with 200 Amp rated bus bar, 415 V, with and including MCCB 4 pole 80 Amp, 16kA., double door type, surface and flush mounting, complete all as specified.
MCB suitable for 240 volt AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 to 32 Amp complete all as specified.
MCB suitable for 240 volt AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 to 32 Amp complete all as specified.
MCB suitable for 240 volt AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 40 to 63 Amp complete all as specified.
Solid rubber cable (protector) straight bridge of size 1000x250x48 mm with two channels each 28x30 mm, slip proof, black/yellow shade, laid on floors as per manufacturers instructions complete. MAKE: Walther Werke Cat No.39870020 or equivalent in Polymax, Wearwell, Universal Enterprises.
Earthing with and including GI earth plate electrode 6 mm thick of size 600 mm x 600 mm with 4 Sq. mm GI wire earthing lead complete all as shown in electrical plate No. 3 and specified in Particular Specifications clause 19A.5.1 of contract, IN REPAIRS. NOTE: (a) The unit rate includes earthing lead and protection pipe upto 7.5 metre from top of earth plate. (b) Factory made PCC pit with cover shall be fixed at least 500 mm away from earth pit.
Chemical earthing with and including copper earth plate electrode 5 mm thick of size 900 mm x 600 mm with 32 mm x 6mm copper strip earthing lead, complete all as shown in electrical plate No. 3 and as specified in Particular Specifications clause 19A.5.1 of contract, NOTE: (a) The unit rate includes earthing lead and protection pipe upto 7.5 metre from top of earth plate. (b) Factory made PCC pit with cover shall be fixed at least 500 mm away from earth pit. (c) For performance gurantee refer PS clause19A.5.5.
Earth continuity conductor or main earthing lead with 20 x 3 mm copper strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified.
Surface mounted envirnment friendly decorative ultra slim round profile LED 22 W lighting fixture with extruded polycarbonate, 6500K, lumen output should not be less than 90 lumens per watt complete. MAKE: Havells Cat No. ENDURALINEARNEOBS22WLED865SPCWH or equivalent in makes mentioned in Appendix 'B' here-in-after.
Recess mounted bottom opening LED 36W cool day light luminaire (2x2) CRCA powder coated housing, IP- 54 protection, suitable for grid ceiling lumen output should not be less than 90 lumens per watt complete. MAKE: Havells Cat No. DROPDOWNFLAT2X2PLR36WLED857 or equivalent in makes mentioned in Appendix 'B' here-in-after.
Exhaust fan 300 mm sweep, heavy duty with louvers fixed to wall with 10 mm dia fasteners, nuts & bolts and connecting up complete from ceiling rose or connector to fan, complete all as specified.
Wall mounting fan 400 mm sweep, high speed, BLDC motor fixed to wall and connecting up complete from ceiling rose or connector to fan, complete all as specified.
Air curtain, 1525 mm long, air throow 21 M/S fixed in position and connecting up complete from ceiling rose or connector to air curtain, complete all as specified.
Disconnecting & taking down carefully split type AC (both indoor & outdoor unit) of any description alongwith complete acessories transporting to E/M store and refixing & reconnecting the same at existing or new locations including charging of gas & testing etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified.
Clean dry sand ( locally available) as cushioning for under ground cable 230 mm thick (one layer of 80 mm thickness before laying the cable and other layer of 150 mm thickness after laying the cable) complete all as specified. NOTE:- Punned down thickness (over all 180 mm) shall be considered for measurement and payment.
Bricks as specified in PS clause 5.1, laid flat and dry in trenches over the cable for protection as length perpendicular to the direction of cable adjacent to each other complete, all as specified.
Boring holes under road pavement / hardstanding by trenchless technology using ultrasound technique and necessary machine for inserting pipe 80-100 mm bore complete, all as specified. NOTE:- Supply only GI pipe shall be measured and paid for separately under respective item of BoQ.
Supply only steel tubes 80 mm bore ‘light grade’, galvanized with all fittings and fixed to poles/ walls/ under floors/ under road etc complete all as speciifed.
Supply, laying, jointing & testing of LT XLPE insulated cable screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor conforming to IS-7098 (Part-I -1988) laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles complete all as specified of sectional area 50 Sq. mm, 3.5 core.
Voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ±2.5% and speed of correction 8 volts per second and of capacity 5 kVA, complete all as specified.
Voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ±2.5% and speed of correction 8 volts per second and of capacity 15 kVA, complete all as specified.
Hi wall mounted split type air conditioner, 5 star rated with minimum ISEER 3.5, invertor type, of capacity 4500 K.cal ( 2 TR), electric drive, single phase 230 Volt 50 hz AC supply indoor & outdoor unit complete with & including cordless remote & brackets for mounting outdoor unit and provision of waste water pipe from indoor unit to outside the building complete all as specified .
Supply, laying, jointing & testing of PVC insulated, armoured, heavy duty electric cable, with aluminium conductor, 1100 volt grade, laid on surface with required acessories complete all as specified of sectional area 1.5 Sq. mm, 2 core.
Supply, laying, jointing & testing of PVC insulated, armoured, heavy duty electric cable, with aluminium conductor, 1100 volt grade, laid on surface with required acessories complete all as specified of sectional area 1.5 Sq. mm, 4 core.
Fire alarm control panel complying with BSEN-54, 2 loop panel of capacity from 99 detectors & 99 modules upto 200 detector and modules complete all as specified.
Addressable type multisensor detector (complying with and type certified to EN-45) with heat & smoke combination, photoelectric/Optical with base with self built intelligence as per IS:11360, complete all as specified.
Addressable control module, complete all as specified.
Addressable manual call point, resettable type, complete all as specified.
Addressable electronic sound cum strobe, complete all as specified.
6 watt ceiling speaker (PA system), complete all as specified.
250 watt amplifier, complete all as specified.
Fire Alarm sounders / Sirens electronic type horizontal two stage continous normal operation for atleast 50 minutes with sound level 65 db to 120 db Measured at 1.5m with sound output variation of +5 db 1500 m range, complete all as specified.
DC power supply 24 volt,10 Amp, complete.
Battery 12 volt, 7.2 mah, complete .
DEMOLITION & DISMANTLING WORKS
Taking down shutters of any description exceeding 1.00 Sq.m but not exc 2 Sq.m each with fittings fixures complete all as specified.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sq.m each and removing from site all as specified.
Taking down steel door/window/gate/ partition with shutters (without taking off shutters from the frames) area exceeding 1.50 Sq.m but not exceeding 4.00 Sq.m each and removing from site all as specified.
Taking down cement plaster of any description on brick walls or concrete surfaces etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises complete all as specified.
Demolition of cement concrete (unreinforced) in ground floors and pavings not excceding 15cm thickness (above or below ground level) all as specified
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete with batten, casing caping of MS or and PVC conduit on surface or concealed, including switches, ceiling roses, pendants, regulators, sockets, mild steel terminal boxes etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified.
Taking down carefully copper/aluminium sub main wiring complete, including existing batten/conduit consealed/surface etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified.
Dismantling of unservisible existing DBs of any description with all accessories and MCBs, isolators etc. and making good surface as per existing, complete all as specified.
Taking down carefully light fitting of any description, complete all as specified.
siddharthenterprises
M/s Sahib and Company
PRATHAM TRADERS
M/S GURBACHAN SINGH
BHARAT ENTERPRISES
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .