Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹42.0 L+₹2.5 L (6.32%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 bidder | |
| 3 | L3₹42.7 L+₹3.2 L (8.01%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 bidder | |
| 4 | L4₹43.2 L+₹3.7 L (9.26%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 bidder | |
| 5 | L5₹44.0 L+₹4.4 L (11.2%)Rejected-Finance 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | L5 | Rejected-Finance Being other than L1 bidder |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
4 Jun 2024, 6:00 pmClosed
GE 862 EWS
GE 862 EWS Rajouri
REPAIR REPLACEMENT TO ROOF FALSE CEILING AND REWIRING IN CERTAIN BUILDINGDS AT ZONE D UNDER AGE BR DETT-III OF GE 862 EWS
2024_MES_652637_1
GER-17/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS Rajouri
Please refer tender documents
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹99,800
Yes
16 Jul 2024
7 May 2024
6 Jun 2024
7 May 2024
4 Jun 2024
22 May 2024
7 May 2024 - 18 May 2024
Amount
S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in roof covering/ cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions, including dismantaling old existing roof sheet of any type complete all as specified and directed.
S&F for Pre-painted galvalume aluminium zinc coating GI based plain sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in ridges, hips, valley gutters fixed with self tapping screws including side and end lap as per manufacturer’s instructions, including dismantaling old existing sheet of any type in ridge complete all as specified and directed.
Dismantling of timber scantling 40 Sqcm and over in section, in any position as in unframed or framed work, complete all as specified and directed.
Dismantling structural steel work including welded fabriks frames, doors, gates, grills grating and framed truss etc, complete all as specified and directed.
M&L for rolled section as in main and cross beams / columns, hip and jack, rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates (Fe-410 W Gde E-250 Quality A) complete all as specified and directed.
Complete removal of existing water proofing treatment over RCC roof, projections of any thickness, any type by stripping out old tar felt over roofs, parapets, chimney stacks etc laid horizontally or vertically including taking out layer of cement plaster etc and cleaning the surface with wire brush including removing debris from the site and depositing in low lying area where directed and providing following :- (a) Rendering 15mm thick in cement mortar 1:4 on concrete roof surfaces and finish the surface even and smooth without using extra cement including mixing water proofing compound @ 2% by weight of cement. (b) Apply a coat of bituminous primer confirming to IS-3384@ 0.4 ltr/Sqm on newly plastered surface after curing as per IS-456 and dried. (c) After the primed surface has dried, apply a coat of hot blown bitumen(85/25 penetration) confirming to IS-702 @ 1.2 Kg/Sqm of the surface. (d) Provide polymeric water proofing membrane ISI marked laid with overlaps, bonded with hot blown bitumen, and laid by torch application method, end overlaps shall not be less than 150mm and side lap 75mm. Polymeric water proofing membrane should be five layered with centre core as 90 micron high molecular high density polyethylene film, min weight 3 Kg per sqm & minimum 3mm thick reinforced with polyster non wove fabric, APP membrane shall laid acorss the slop from lowest line of sloping roof towards ridge. (e) Over the APP membrane, apply a coat of semi hot blown 85/25 penetration grade bitumen confirming to IS-702 @ 1.20 Kg/ sqm and blinded with fine sand in dry condition @ 0.50 Kg / Sqm dusted over the bitumen coat. Note : (i) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface. (ii) Ponding test shall be conducted for 72 hrs as directed. (iii) Rate of WPC included in the quoted rate.
M&L for repairing the edges of the chajja/roof projections in cement mortar 1:3 finished fair and even and applying two coats of cement base paint including taking down the loose concrete /plaster and removing the debris off the premises, complete all as specified and directed.
M&L for cutting out cracks to 'V' section in existing roofs or terrace, cleaning out, wetting, grouting with cement and sand mortar 1:3, complete all as specified and directed.
M&L for plain cement concrete type B-1, 1:2:4 (using 20mm graded stone aggregate) as in kerbs, coping, benching, water troughs, bed block, bed plate, and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work ,complete all as specified and directed.
S&F for 4mm thick designer ceiling board in ceiling fixed with screw as per manufacturers instructions, laid over and including hot dipped galvanised iron in post grid with 24mm wide T section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33 mm thick galvanised steel sheet of size 24 x 32 x 300 mm spaced at 1200 mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of GI wire 4 mm dia to be fixed by approved rawl plug or hanged with existing truss members. The last hanger at the end of each main runner shall not be greater than 450 mm from adjacent wall flush fittings of 1200 mm long screws Tee with (double stiching) to interlocked between main runners at 600 mm centre to centre from 1200 x 600 mm modules cross tee longer than 600 mm modules to be formed by fittings 600 mm long cross tee, tee perimeter wall angle shall be of 0.45 mm thick galvanised steel of size 19 x 19 mm and 300 mm long of white colour all as per instructions including dismantling of existing board etc, complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 Sqm each and removing from site, complete all as specified and directed.
S&F for steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and directed.
S&F for steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded, complete all as specified and directed.
M&L for steel ventilators with top hung shutters openable type including hinges and handle with steel peg stay complete without glazing bars, dovetailed or welded, complete all as specified and directed.
M&L in repair for mild steel framed work such as grills, gratings etc, with ends of bars shouldered and/or riveted, or forget into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks or portion framed and hung as gates, including pintel hinges, stops, hand made sliding bolt, hold fast etc and similar work conforming to Fe 290 or E-165 work including welded fabricks frames, gate and framed truss etc, complete all as specified and directed.
M&L for preparation of new steel surface exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified.
M&L for preparation of new wooden surface of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
M&L for preparation of old steel surface of any description exc 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
M&L for preparation of old wooden surface of any description exc 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
S&F for 3 mm thick sheet glass ordinary quality and glazing with oil putty / wooden beads in squares not exc 0.50 sqm in each pane including hacking out old glass, complete all as specified and directed.
S&F for 3 mm thick figured glass pin headed type and glazing with oil putty in squares n . exc 0.50 sqm in each pane including hacking out old glass, complete all as specified and directed.
S& F in repair for galvanised mild steel wire cloth, 0.50mm nominal dia of wire and average width of aperature 1.4m and fixed with tinned tacks, or galvinsed wire staples including cutting, welding etc for steel window / ventilators , complete all as specified and directed.
S& F for galvanised mild steel wire cloth, 0.50mm nominal dia of wire and average width of aperature 1.4m and fixed with tinned tacks, or galvinsed wire staples including cutting, welding etc for steel window / ventilators , complete all as specified and directed.
Taking down cement plaster, any description on any walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick surface/ concrete surface of wall in cement mortar 1:6, finished surface even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 15 mm thick on other than fair faces of brick surface/ concrete surface of wall in cement mortar 1:4, finished surface even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 5 mm thick in cement mortar 1:3 on concrete surface of ceiling, finished surface even and smooth without using extra cement, complete all as specifed and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of white cement primer, complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of alkali resistant primer and a coat of wall care putty 1.5mm thick, complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash, complete all as specified and directed.
M&L for complete removal of existing treatment of walls and applying two coats of oil bound distemper over a coat of alkali resistant primer including preparation of surface, complete all as specified and directed.
M&L for complete removal of existing treatment of walls and applying two coats of cement base paint over a coat of white cement primer including preparation of surface, complete all as specified and directed.
M&L for preparation of old plastered or unplastered surfaces of wall by brooming down or steel wire brushing, scraping down smook soot , moulds, moss and efflorescent slats and trading oil and greasy spot and applying one coat of oil bound distemper, complete all as specified and directed.
M&L for preparation of old plastered or unplastered surfaces of wall by brooming down or steel wire brushing, scraping down smook soot , moulds, moss and efflorescent slats and trading oil and greasy spot and applying one coat of cement base paint, complete all as specified and directed.
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles, complete all as specified and directed.
M&L for stone walling of random rubble masonry, uncoursed, well bonded, bedded and soilidly hearted, built in cement mortar 1:6, complete all as specified and directed.
M&L for brick work with sub class 'B' bricks, old size, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:4 , complete all as specified and directed.
M&L for brick work using old size bricks sub class 'B', straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4, complete all as specified and directed.
M&L for rendering 15 mm thick on other than fair faces of stone masonry surface of wall in cement mortar 1:4, finished surface even and smooth without using extra cement, complete all as specified and directed.
M&L for 15 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, tee, elbow, union, nipple, short pieces and fixed to walls, ceilings or laid in floors including taking down existing GI tubes complete all as specifed and directed.
M&L for 20 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, tee, elbow, union, nipple, short pieces and fixed to walls, ceilings or laid in floors including taking down existing GI tubes complete all as specifed and directed.
S&F in repair for vitreous china wash hand basin white, flat back, size 450x300mm size, cutting for and pinning ends of brackets, including 15mm bore pillar tap CP cast copper alloy including PVC connection 15mm dia 450mm long and PVC waste pipe low density complete all as specified and directed.
S&F for rotational moulded polythylene water storage tank (ISI marked) with float valve, plastic lid cover, multy-layered, cylindrical vertical with closed top, hoisted and fixed in position of capacity 500 ltrs tank and making connections inlcuding suitable GI wash out, over flow, nipple and 20mm bore ball brass valve with union screwed for iron pipe and fixed including dismantling of old unserviceable tank, complete all as specifed and directed.
S&F for rotational moulded polythylene water storage tank (ISI marked) with float valve, plastic lid cover, multy-layered, cylindrical vertical with closed top, hoisted and fixed in position of capacity 1000 ltrs tank and making connections inlcuding suitable GI wash out, over flow, nipple and 20mm bore ball brass valve with union screwed for iron pipe and fixed including dismantling of old unserviceable tank, complete all as specifed and directed.
S&F in repair 20mm bore ball valve high pressure PTMT with polythelene float and fly nut and fixed, complete all as specifed and directed.
S&F in repair for 15mm bore bib tap cast copper alloy with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule, complete all as specified and directed.
S&F in repair for 15mm bore swan neck, pillar cock, cast copper alloy, with capstan heads, chromium plated, fancy type, screwd down high pressure , with or without lettered hot or cold with long screwed shanks and fly-nuts, screwed for iron pipe and fixed, complete all as specified and directed.
S&F in repair for 15mm bore brass chromium plated sink mixer for mixing hot & cold water screwed down for iron pipe and fixed, complete all as specified and directed.
S&F in repair for 15mm bore brass chromium plated brass wall mixer 2 in 1 two for hot and cold water mixing and one for shower rose, complete all as specified and directed.
S&F in repair for 15mm bore brass chromium plated pillar tap, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nut, capstan heads, screwed for iron pipe and fixed, complete all as specified and directed.
S&F in repair for 15 mm bore brass chromium plated wash hand basin mixer hot & cold water screwed down for iron pipe and fixed, complete all as specified and directed.
S&F in repair for 15mm bore stop valve, cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed, complete all as specified and directed.
S&F in repair for 10 ltrs capacity PVC, valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, complete all as specified and directed.
S&F in repair for viterous china wash down water closet pan, white (pedestal pattern), including PVC flushing cistern 10 ltr capacity and fixed in floor with brass screw, plastic water closet seat, black/white, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device, and inlcuding set of CP jet spray with flexible PVC pipe of superior quality, complete all as specified and directed.
S&F in repair for vitreous China water closet (squatt pan) Orrisa pattern 580x440 mm size pan, white, with front or back inlet with integral 'foot rests including provn of lime concrete bedding including connections to flushing cistern/pipe including trap set in concrete and removing debries from site, complete all as specified and directed.
S&F for chromium plated brass shower rose of size 125 mm with swivel joints fixing to steel pipes etc. Complete as in repair all as specified and directed.
S&F in repair for vitreous china half stall type urinals, aqua seal premium quality, complete including providing and fixing plugs, securing urinals to plugs with and including 60mm long brass screws, fixing flush pipe, waste pipe, grating and union for discharge pipe, complete all as specified and directed.
S&F in repair for vitreous chinaware urinal partition of any size and shape, complete all as specified and directed.
M&L for vitrified tiles light shade (premium quality) 9-10 mm thick (square/ rectangular) polished, area of each tiles n exc 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface, laid over and including 15 mm thick screed bed in cement mortar 1:4 including dismantling old unserviceable tiles, complete all as specified and directed.
M&L for vitrified tiles light shade (premium quality) 9-10 mm thick (square/ rectangular) polished, area of each tiles n exc 0.36 sqm in dados / skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface, laid over and including 10 mm thick rendering in cement mortar 1:4 including dismantling old unserviceable tiles, complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (premium quality) Square/rectangular, area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 15mm thick screed bed in cement mortar 1:4, including dismantling old unserviceable of tiles, complete all as specified and as directed.
M&L for glazed ceramic coloured tiles of size 350 x 250 x 7mm or 450x350x7mm thick, (premium quality) on vertical surface of wall such as dado, skirting, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 10mm thick rendering in cement mortar 1:4 including dismantling old unserviceable tiles, complete all as specified and as directed.
M&L for joint free ceramic coloured tiles 7 to 8 mm thick (premium quality) Square/rectangular, area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 10mm thick backing coat in cement mortar 1:4, including dismantling old unserviceable of tiles, complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floor and paving n exc 15 cm thickness below or above the ground level and removal of debris from site, complete all as specified and directed.
M&L for 75mm thick plain cement concrete, type C-2, 1:3:6 (using 40mm graded crushed stone aggregate) sub base of tile etc, complete all as specified and directed.
M&L for plain cement concrete 1:4:8, type D-2, (using 40 mm graded crushed stone aggregates) as in foundation filling and mass concrete, complete all as specified and directed.
M&L for 25mm thick PCC 1:2:4, type B-0 (using 12.5mm graded crushed stone aggregates) as in sub base surface finished even and rough to receive tiles, complete all as specified and directed.
M&L for Machine cut kota stone slab (mirror polished) flooring 20-22mm thick as in floors and jointed with grey cement slurry mixed with pigment to match the shade of the slab including machine cutting to make it square or rectangular, rubbing and cutting and polishing to achieve mirror finish, laid over and including screed bed or bedding layer of 20 mm thick in cement mortar 1:4 including demolition of old kota stone, complete all as specified and directed.
M&L for 20mm thick granite stone slab (of any type) work (table rubbed and polished) in steps, jambs, cooking platforms, in steps, pillars, window cills, etc, laid over 20mm thick bedding in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match the shade of granite slab, rounding edges cutting, polishing etc including demolition of old granite slab, complete all as specified and directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, landings and similar work; n exc 200mm thick (Horizontal and sloping) for rough finished surface of concrete, complete all as specified and directed.
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, complete all as specified and directed.
M&L for RCC 1:2:4, type B-1 (using 20mm graded stone aggregate) as in slab supported on walls, beams and columns in floor, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, including demolition of old RCC work, complete all as specified and directed.
M&L for mild steel TMT bars 10 to 12mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
M&L for mild steel TMT bars 6mm to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
Taking down chowkhats or frames (without taking off shutters from the frames) exc 1.5 Sqm and n. exc 4 Sqmm each and removing from site including making good to disturbed portion, complete all as specified and directed.
Taking down shutters of any description area exc 1 sqm and n.exc 2 sqm each and refixing in same opening with necessary fittings complete all as specified and directed.
Taking down shutters of any description area exc 1 sqm and n.exc 2 sqm each complete all as specified and directed.
S&F for anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc, complete all as specified and directed.
M&L for anodised aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, mortice lock, 1 Nos floor door stopper, anodised aluminium snap beading, screws etc. complete all as specified and directed.
M&L for anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no). hinges type B-21 100mm long (2 no.) suitable handle (1no), complete all as specified and directed.
S&F for sheet glass 5.5 mm thick, ordinary quality and fixed with aluminum & rubber beading in square exc 0.5 sqm in each pane, complete all as specified and directed.
S&F for pressed steel door frames of size 125x60 mm with one or more rebates including necessary fixing lugs, hinges, lock and strike plate etc including back filling to chowkhats in PCC 1:3:6, type C-1 using 20mm graded crushed stone agregate, complete all as specified and directed.
S&F for pressed steel frame for doors with one or more rebates of size 105x60mm including necessary fixing lugs, hinges, lock and strike plate etc including back filling of chowkhats with PCC 1:3:6, type C-1 using 20mm graded stone agregate, complete all as specified and directed.
S&F for factory made 35mm flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as specified and directed
S&F for factory made 35 mm thick 2nd class hard wood glazed and skelton shutters open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats, complete all as specified and directed.
M&L for 300mm long mild steel sliding door bolt, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate (ISI Marked), complete all as specified and directed.
M&L for aluminium alloy, anodised, sliding door bolt 300mm long, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy, (ISI Marked), complete all as specified and directed.
M&L for 300mm MS ordinary rat tail rod pattern door springs (ISI marked) including roller and roller plate, complete all as specified and directed.
S&F block boards 18/19mm thick grade-II interior grade, commercial type with decorative face veneer on both faces fixed with screws including 6mm thick teak wood leaping as in cubboard including builders hardware fittings, complete all as specified and directed.
S&F in repair of 3mm thick fibre glass reinforcement transculant plain sheeting with side lap fixed with angle iron posts with coach screw and washer including nut and bolts in view cutter above the wall etc, complete all as specified and directed.
S&F in repair for framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc. n. exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified and directed.
M&L for PCC 1:2:4, type B-1 using 20mm graded crushed stone aggregates as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed
S&F in repair of 3mm thick fibre glass reinforcement transculant corrugated sheeting with side lap fixed with coach screw, nut and washer etc, complete all as specified and directed.
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete, including all fittings such as switches, ceiling roses, pendants, regulators sockets etc.) removing material from the site and making good the disturbed surfaces of walls, floor or ceiling etc. to match with existing specifications, complete all as specified and directed.
M&L for modular point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through PVC concealed conduit (minimum 25mm in width), with fittings such as tee, corners, overlapping, connectors, etc fixed under walls, ceiling, floors etc including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty and fabricated branded modular metal flush boxes with modular white cover plate and frame concealed in walls with suitable modular fitting housing switches, socket outlet and fan regulators etc, complete all as specified and directed. (Note:- Three run of copper conductor of required size and and colour coding of wiring to be followed as red/yellow/blue for phase, black of neutral and green for earth)
Description all as per srl item No. 96 above but one 3 pin 6 amp socket outlet on same board controlled by one 5 amp switch, complete all as specified and directed.
Description all as per srl item No. 96 above but one 3 pin 6 amp socket outlet on independent board controlled by one 5 amp switch, complete all as specified and directed.
Description all as per serial item No 96 above but for one 3 pin 15 amp socket outlet independent with 2.5 sqmm PVC insulated FRLS multistranded copper conductor cable with 2.5 sqmm single core multistranded FRLS copper cable as earthing lead, complete all as specified and directed.
S&F for modular switch 6 Amps, one way, one module complete all as specified and directed.
S&F for modular switch 16 Amps, one way, one module complete all as specified and directed.
S&F for modular socket outlet 6 Amps, 2/3 pin combination, 2 module complete all as specified and directed.
S&F for modular socket outlet 6/16 Amps, 6 pin combination, 2 module complete all as specified and directed.
S&F for modular stepped type fan regulator electronic, 100 watt, 2 module, complete all as specified and directed.
Taking down ceiling fan, sealing cable end, dismantling blades and removing fan and blades to store and including painting of ceiling fan with synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust etc and reinstalled at existing position including marking MES number complete all as directed by Engr-in-Charge.
S&F in repairs high efficacy 2 x 2 feet recess / surface mounting LED flat panel light fittings 36W LED, white, powder coatedc CRCA housing with high power LEDs, aluminium front frame with high transmission acrylic cover, internally prewired, 230 volts complete with all accessories such as electronic driver, LED strip, connector block etc and necessary fixing arrangement at any height, complete all as specified and directed. Note: Material required such as for safety harness, ladder and T&P etc will be provided by the contractor without any extra cost.
M&L in repair for sheet metal enclosure MCB distribution board, double door single pole and neutral with IP-43 IK-09 protection single phase 240 volt 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good disturb wall surfaces to match with existing specification, complete all as specified and directed. (Note:- MCBs will be measured and paid separately.)
M&L in repair for MCB single pole, 240 volts any rating from 6 to 32 amps, with rupturing capacity 10 KA, 'C' curve including providing thimble for out going cables, complete all as specified and directed.
M&L in repair for MCB single pole & neutral 240 volts any rating from 40 amps, with rupturing capacity 10 KA, 'C' curve including providing thimble for out going cables, complete all as specified and directed.
M&L in repair for 40mm bore galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls for protection, complete all as specified and directed.
J. PRO BUILDERS
SATVIR GUPTA ENGINEER and CONTRACTOR
MEHTA OM PARKASH
NATIONAL TRADING COMPANY
VIJAY KUMAR SURI AND SONS
M/s Anil Engineers & Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .