Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-AOC C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L1 | Accepted-AOC FIRST LOWEST BIDDER | |
| 2 | L2₹27.1 L+₹3.3 L (13.7%)Rejected-AOC NEAR PUNJAB NATIONAL BANK KANDOLI NAGROTA JAMMU J K 181221 | JAMMU | JAMMU | JAMMU AND KASHMIR | 181221 | L2 | Rejected-AOC SECOND LOWEST BIDDER | |
| 3 | L3₹27.5 L+₹3.7 L (15.6%)Rejected-AOC | L3 | Rejected-AOC THIRD LOWEST BIDDER | |
| 4 | L4₹30.2 L+₹6.4 L (27.0%)Rejected-AOC | L4 | Rejected-AOC FOURTH LOWEST BIDDER | |
| 5 | L5₹30.9 L+₹7.1 L (29.6%)Rejected-AOC | L5 | Rejected-AOC FIFTH LOWEST BIDDER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
17 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Nagrota
Garrison Engineer Nagrota Pin 901208 c/o 56 APO
REPAIR REPLACEMENT OF INTERNAL WIRING INCLUDING FITTING AND FIXTURES AT JCO ORS MD ACCN UNDER GE NAGROTA
2023_MES_591448_1
8516/2023-24
Open Tender
Civil Works
Item Rate
180 days
Nagrota
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
₹90,000
Yes
28 Jun 2023
26 Apr 2023
24 May 2023
26 Apr 2023
17 May 2023
11 May 2023
Amount
SCHEDULE ‘A’ PART-I Taking down carefully unserviceable aluminium point wiring (light, fan, socket bell or power) complete, (fittings such as switches, ceiling rose lamp holder, regulators, sockets, pendants) stacking at site and keeping in safe custody for taking credit complete all as specified & directed .
Taking down ceiling fan any sweep, removing blades ,cleaning the fan completely for dust and dirt and hanging the same back to its original positions including connecting with three core flexible copper wire to ceiling rose etc after the completion of the point wiring including replacement of old unserviceable fan hook, rubber pad, nut bolts and washers etc, complete, all as specified and directed
Taking down existing energy meters, keeping aside safely & refixing the same in its original position after making functional & after completion of point wiring/sub main wiring, complete, all as specified and directed Note:- Small items required for fixing the electric energy meter at site shall be provided by the contractor and cost for the same shall be deemed to be included in the quoted rates.
Taking down existing electric water heater, keeping aside safely & refixing the same to its original position after servicing of the whole geyser/making functional and after completion of wiring work, complete, all as specified and directed Note: If any part found unserviceable during the refixing of water heater at site shall be provided by the contractor and cost for the same shall be deemed to be included in the quoted rates.
M&L for Point wiring using FRLSH PVC insulated unsheathed multi strand copper conductor cable 1100 volt garde 1.5 sqmm including 1.5 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor earth wire drawn through and including PVC conduit medium grade ISI marked not less than 20 mm dia concealed in wall and surface on ceiling with all conduit fittings etc terminated in and incl concealed pressed steel sunken box readily available ( having wall thickness not less than 1.22 mm upto 200 x 300 mm box size & having wall thickness not less than 1.63 mm beyond 200 x 300 mm ) duly covered with 3 mm thick bakelite sheet cover for fixing switches , sockets , fan regulators etc incl testing and making good to disturbed surface to match existing surface for one light/fan/bell point complete all as specified and directed.
All As per Srl item N0 5 above but for one socket out let 5 Amp controlled by one switch on same board with other switch .
All As per Srl item N0 5 above for one socket out let 5 Amp controlled by one switch on independent board with other switch .
All as per item No 5 above but point wiring with 2.5sqmm FRLS multi stranded copper conductor cable for main circuit and 2.5sqmm cable as earth continuity conductor for one 15Amp socket out let controlled by one 15Amp switch on independat board.
All as per item No 5 above but point wiring with 4 sqmm FRLS multi stranded copper conductor cable for main circuit and 4 sqmm cable as earth continuity conductor for controlled by two pin and earth plug and socket complete with one single pole MCB 20 amp 240V complete as specified and directed.
S&F Single pole mcb with a two pin and earth plug and socket complete with one single pole MCB 20 amp 240V complete as specified and directed.
S&F switch piano flush type 5 Amps single pole one way complete as specified and directed.
S&F switch socket combination 2 in 1, 3 pin, 5 Amp flush type complete as specified and directed.
S&F switch socket combination 2 in 1 5 pin 5 /15 Amps flush type complete as specified and directed.
S&F of ceiling rose surface type 65mm x 50mm 2 to 3 terminal complete as specified and directed.
S&F Step type fan regulator 300 watt, 230 volts, 50 HZ, AC. Supply complete .
S&F bell push piano type 5 Amps complete as specified and directed.
S&F electric bell ding dong 230 volt AC complete as specified and directed.
M&L Integrel sleek extruded PVC aluminium channel fitting with LED 18 watt complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230V 50 Hz complete as specified and directed. Make : Orient Cat part No. LBLN-18-C-SQAL or equivalent in make as specified in PS
S&F batten integrated LED channel of 5W, 230V frequency 50/60 Hz integral sleek extruded polycarbonate LED channel with white acrylic cover, Power Factor not less then 0.9 complete as specified and directed.
M&L LED light fitting 1x9W bulk head luminaries IP 65 complete with all accessories including LED lamp 9 watt , connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V 50 Hz .complete as specified and directed.
S&F for lamp holder PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F for LED bulb 7 watt complete all as specified and directed.
Supply & fixing heavy duty PVC Exhaust fan 250/300 mm sweep single phase AC 230/240V complete all as specified and directed.
Supply and fix house service static electronic temper proof energy meter AC single phase static energy meter of accuracy class 1.0 rating 10-60 A, 240 V ,50 Hz static watthour meter. complete all as specified and directed.
S&F MCB single pole 5 to 32 Amps 10 KA 240 volts "C" series complete as specified and directed.
S&F MCB SPN 40 A to 63 A 10 KA 240 volts "C" series complete as specified and directed.
S&F TPN 63 4Pole 16KA 415 Volt with fixed magnetic and fixed thermal setting complete as specified and directed.
S&F MCB single pole 63 Amps 10 KA 230 volts "C" series complete as specified and directed.
S&F MCCB 125A 4Pole 16KA 415 Volt with fixed magnetic and fixed thermal setting complete as specified and directed.
S&F MCCB 100A 4Pole 16KA 415 Volt with fixed magnetic and fixed thermal setting complete as specified and directed.
S&F sheet metal enclosure distribution board SPN 12 way 230 V, 50 Hz double door with neutral, Earthing bar and din rail complete incl taking out existing UNSV DB with MCBs.complete all as specified and directed.
S&F sheet metal enclosure distribution board SPN 8 way 230 V, 50 Hz double door with neutral, Earthing bar and din rail complete incl taking out existing UNSV DB with MCBs.complete as specified and directed.
S&F sheet metal enclosure distribution board SPN 4 way 230 V, 50 Hz double door with neutral, Earthing bar and din rail complete incl taking out existing UNSV DB with MCBs.complete as specified and directed.
S&F sheet metal enclosure double door for distribution board factory made for MCB DB load link Vertical TPN 4 way suitable for MCCBas incomer, 125 Amp,4 pole. (when MCB's are to be used) with suitable size of busbar including 125 A MCCB as incomer 16 KA complete,fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification incl taking out of exsing UNSV DB with MCBs.complete as specified and directed.
M&L in replacement of sub main wiring with two single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 Sq mm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked minimum 20 mm dia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 sq mm as earth continuity conductor connected to commen earth and earth dolly complete as specified and directed.
S&F building security light luminaries eenergy saving and envirnment friendly long life LED light of 25W made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP66 protection and Impact resistanve of IK07, including MS Bracket light grade 25 mm dia, 1.2 m long bend in shape fixed on wall having an angle 120 degree, fixed with and suitable size nuts, bolts and washers etc including taking down of existing light fitting and complete ,all as specified and directed.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit shall be filled with charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part-I (1991) as specified including provision of 15mm dia medium grade GI pipe for earth wire protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point / main switch board as specified and testing on completion complete as specified and directed.
Taking down the water heater storage type of any make of any capacity. dismantling the water heater carefully from its position fixed on walls, reassembling the water heater after replacement of defective parts and reinstalling the water heaters to their original locations or as directed, commissioning and testing the water heater complete as specified and directed. Note: Any material/part found unserviceable during servicing shall be replaced by the contractor and measured and paid separately under respective items.
S&F in repairs PVC connection of any make with (ISI Mark) having10mm dia, 45 cm long with steel reinforcement suitable for hot water geyser outlet supply with 02 Nos of Unions/ cup shaped cover with washers all as directed
S&F in repair of PVC connection of any make with (ISI Mark) having 10mm dia, 45 cm long suitable for cold water geyser inlet with 02 Nos of Unions/ cup shaped PVC cover with washers all as directed b
S&F in replacement of unserviceable inlet /outlet assembly of any make of geyser having six/seven/eight /nine hole suitable for Bathwell/ Bajaj / pearl water heater of capacity 25/50 litre all as directed
S&F in replacement of unserviceable inlet /outlet assembly of any make of geyser having six/seven/eight /nine hole suitable for Bathwell/ Bajaj / pearl water heater of capacity 10 litre all as directed
S&F in replacement of unsv rubber gasket suitable for six/seven/eight/ nine hole assembly of suitable size of water heater of capacity 50/25/10 ltr.complete as specified and directed.
S&F in replacement of unsv 4'' long and 1/2'' dia Chrome plated bolt with suitable washers complete as specified and directed.
S&F in replacement of insulating material (glass wool) suitable for 25/50 litres capacity water heater,complete as specified and directed.
S&F in place of unsv split bottom cover (two pieces) suitable for water heater of any capacity duly painted, complete all as specified and directed.
S&F in place of unsv neon indicating lamp, rectangular /round as required at site complete all as specified and directed.
S&F in replacement of unsv heating element 1.5 KW, single phase, 230 volt with triangular base suitable for 25/50 Ltr water heater complete all as specified and directed. .
S&F in replacement of unsv heating element 2.0 KW, single phase, 230 volt with triangular base suitable for 25/50 Ltr water heater.
S&F inreplacement of unsv heating element 1.5 KW, single phase, 230 volt with round base suitable for 25/50 Ltr water heater complete all as specified and directed. .
S&F in replacement of unsv heating element 1.5 KW, single phase, 230 volt with round base suitable for 10 Ltr water heater complete all as specified and directed. .
S&F in replacement of long thermostat switch range upto 80”C suitable for 25/50 ltrs cap water heater complete all as specified and directed. .
S&F in replacement of steel outer body 50 Ltrs capacity, any make complete all as specified and directed
S&F in replacement of steel outer body 25 Ltrs capacity, any make complete all as specified and directed
S&F in replacement of unserviceable electric cable copper conductor, 3 core 2.5 Sqmm with PVC insulation complete all as specified and directed. .
S&F in replacement of unserviceable plug top 3 pin 15 Amps complete all as specified and directed.
S&F in replacement of unserviceable safety nut for geyser of capacity 25/50 ltrs complete all as specified and directed.
S & F in replacement of unserviceable Switch socket combination 3 pin 16A, flush type complete all as specified.
S & F in replacement of unserviceable sheet metal enclosure with socket plug top and MCB single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20Amp complete complete all as specified and directed.
Disconnecting & taking up or down the existing old unserviceable solar panel (flat collector plate ) of any description and in any position from the existing location for necessary repairs & maintenance / replacement complete all as specified & directed
Taking down existing unserviceable solar plate of any description and supply and fixing new solar flat plate collector complete of existing shape & size. complete all as specified & directed
Taking down old existing unserviceable thermal insulation of any description and in any position including aluminum foil cladding from GI pipe lines 15 to 25mm dia complete all as specified & directed .(NOTE : Aluminium foil cladding obtained in serviceable condition shall be re-used in the work ).
Dismantling the solar panel (made of flat collector plates) of any description, material and labour for cleaning the glass by washing with using soft detergent, cleaning & de-scaling the inside surface of copper fins / tubes with suitable size of drill rod, wire brush & with circulating concentrated de-scaling solution(ORISCALE BLASTER) mixed with water in suitable proportion circulating through pump till the complete deposits/scale is removed and approved by the Engineer-in-Charge, brazing the leaking copper tubes, fixing the copper tube & fins properly in their respective positions, reassembling the solar system after servicing / maintenance including replacement of flanges made out of gun metal, nuts, bolts & washers, gaskets etc., fixing & installation of the solar flat collector plate in position and its testing to the entire satisfaction of Engineer-in-Charge.
Material & Labour for Insulation of GI pipe 15 to 25mm dia with providing 25mm uniform thickness of glass wool fibers having density of 48 Kg per Cum, including cladding with using old serviceable aluminium foil all as directed.
Supply and fixing GI tubings medium grade 15mm bore dia ISI Mark with all fittings such as elbow, bends, sockets, nipples and union etc and fixed complete laid in trench/wall for the following sizes including taking down of existing old GI pipes complete all as specified and directed
All as per Ser item no 65 above but 20mm bore complete all as specified and directed.
All as per Ser item no 65 above but 25mm borecomplete all as specified and directed
All as per Ser item no 65 above but 40mm bore complete all as specified and directed
All as per Ser item no 65 above but 50mm bore complete all as specified and directed
Supply and Fixing 15mm Gun metal Globe or gate valve with iron wheel head screwed both ends for iron pipe of the following bore sizes complete all as specified and directed.
All as per Ser item no 70 above but 20mm bore complete all as specified and directed
All as per Ser item no 70 above but 25mm bore complete all as specified and directed
All as per Ser item no 70 above but 40mm bore complete all as specified and directed
All as per Ser item no 70 above but 50mm bore complete all as specified and directed
Disconnecting & taking out existing unserviceable tap, 15mm bore of any description and in any position and supply, fixing, jointing and testing, 15mm bore, concussive push button taps of cast copper alloy, chromium plated, screwed for iron pipe and fixed complete all as specified and directed
Disconnecting & taking out existing unserviceable non return valve, 25mm bore of any description and in any position and supply, fixing new 25mm bore non return valve, cast iron, ISI marked complete all as specified & directed
Disconnecting & taking out old existing unserviceable temperature meter of any description and in any position and supply, fixing new temperature meter, 0-100 ºC range, dial type suitable for 15mm GI pipe including all necessary fittings complete all as specified and directed.
Opening of existing aluminium cladding from tank ,cleaning and stacking the same for reuse ,taking out glass wool and repairing the stainless steel tank and repairing the leakage by means of TIG welding as approved ,refilling of glass wool ,aluminium cladding by using old aluminium sheet complete all as directed . Note:- Existing glass wool and aluminium sheet shall be reused, new glass wool and aluminium sheet if required shall be not measured and paid for separately complete all as specified and directed
Disconnecting and taking out old existing unserviceable water heating element of any description and in any position and supply, fixing new water heating element hexagonal/ Rectangular/circle type of capacity 5 KW with suitable thermostat as per existing site including all necessary fittings complete all as specified and directed.
Disconnecting & taking up or down existing unserviceable copper conductor flexible cable of any size & any description and supplying, fixing, connecting & testing new 3 core copper conductor flexible cable of 2.5 sqmm size, PVC insulated and PVC sheathed suitable for 1100 volts grade complete all as specified and directed
Supply and fixing in replacement of insulated tank of 500 Ltr capacity with Electric back complete all as specified and directed
Material & labour for damaged solar collectors of copper fins / tubes with suitable size of drill rod, wire brush & with circulating concentrated , brazing the leaking copper tubes, fixing the copper tube & fins properly in their respective positions, reassembling the solar system after replacement of flanges,collectors made out of gun metal, nuts, bolts & washers, gaskets etc., fixing & installation of the solar flat collector plate in position and its testing to the entire satisfaction of Engineer-in-Charge complete all as specified and directed
M/s Khajuria Construction Co.
Nitika electricals and engineers works
Warne Builders
Kalsi Engineers and contractors
LAL CONSTRUCTIONS
M/S ANMOL TRADING CO
ASHOKA ENGINEERS AND BUILDERS
Prakash Trading Corporation
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .