Karnataka Power Transmission Corporation Limited
ANITHA V
Establishment of Statewide Optical Ground Wire (OPGW) and IP MPLS communication Network for Karnataka Power Transmission Corporation limited Part-I
KPTCL/2026-27/OF/WORK_INDENT3626
KPTCL/2026-27/OF/WORK_INDENT3626
Open
Optic fiber cables
Two Tender Document System(Two Cover)
KPTCL CEE Office SLDC AR Circle Bengaluru
₹7,500
₹8.0 Cr
4 Sept 2026
17 Apr 2026
18 May 2026
24 Apr 2026
24 Apr 2026
OPGW route length for 110kV and 66kV lines in KPTCL
Name of the Zone Noof links Rote length in km
MYSORE 55 790.715
HASSAN 57 998.179
TUMKUR 44 806.416
GULBARGA 92 1799.948
BANGALORE 60 813.663
BAGALKOT 90 1674.09
110 kv & 66 Kv Stations
Name of the Zone 66kv or 110kv Stations
MAIN RING Sub-Station List
Sl No Kalburgi Zone Sl No Bagalkot Zone Sl No Hassan Zone Sl No Bengaluru Zone Sl No Mysuru Zone Sl No Tumkur Zone
1 110kV AdaviAmreshwara 1 110kV Achanur 1 110kV Alkola 1 66kV Alur 1 66kV AC Giri 1 66kV BG Kere
2 110kV Aurad 2 110kV Anavatti 2 110kV Anavatti 2 66kV Andersonpet 2 66kV Bannimantapa 2 66KV Kukkawada
3 110kV Ballari North 3 110kV Ankola 3 110kV Anveri Mini Hydel IPP 3 66kV Attibele 3 66kV Bannur 3 66kV Anchepalya
4 110KV Ballari South 4 110kV Anmod 4 110kV Ayanur 4 66kV Attur 4 66kV BG Nagara 4 66kV Ankasandra
5 110kV Betagera 5 110kV Arga 5 110kV Balligavi 5 66kV Air EHT 5 66kV Bhatna 5 66kV Antharasanahalli
6 110KV Bislahalli 6 110kV B Bagewadi 6 110kV Bejavalli 6 66kV Bangarpet 6 66kV Bogadhi 6 66kV Avargere
7 110kV Bygwat 7 110kV Bagalkot 7 110kV Bharangi 7 66kV Bannerghatta Road 7 66kV Devanur (Mysuru) 7 66kV Baddihalli
8 110kV chidri 8 110kV Betageri 8 110kV Gajanur 8 66kV Budikote 8 66kV Devanur N gudu 8 66kV Balenahalli
9 110kV Chittapur 9 110kV Butnal 9 110kV Gurupura 9 66kV Burudugunte 9 66kV Elvala 9 66kV Basavapttana
10 110kV Dadesugur 10 110KV Chikkabasur 10 110kV Haladi 10 66kV BWSSB T GHalli 10 66kV FTS 10 66kV Bellavi
11 110kV Devadurga 11 110kV D. Hipperagi 11 110kV Heggunje 11 66kV Byadarahalli 11 66kV G Ukkada 11 66kV Bhaktharahalli
12 110kV Dongargaon 12 110kV Daddi 12 110kV Heggunje 12 66kV Chandapura 12 66kV G.Malligere 12 66kV Brahmasagara
13 110kV Ginigera 13 110kV Dambal 13 110kV Hiriyadka 13 66kV Chintamani 13 66kV Goluru 13 66kV Bramhasandra
14 110kV GlBUnivercity 14 110kV Esale 14 110kV Hosangadi 14 66kV D Cross 14 66kV Guddenahalli 14 66kV Chalkere
15 110kV GlBUnivercityII 15 110kV Gadagroad 15 110kV Hulikal 15 66kV D Palya 15 66kV Hanagodu 15 66kV Chelur
16 110kV Gugal 16 110kV Gajendragad 16 110kV Jeppu 16 66kV Dabaspet 16 66kV Hebbal 16 66kV Doddasarangi
17 110kV Gulbarga(North) 17 110kV Gopanakoppa 17 110kV Jog 17 66kV Dibburhalli 17 66kV Hemmergala 17 66kV Dyavaranahally
18 110kV Gurmitkalline 18 110kV Haliyal 18 110kV Kammaradi 18 66kV Divyashree Tech Park 18 66kV Hirisave 18 66kv Gowribidnur
19 110kv Habsikote 19 110kV Hanumasagar 19 110kV Karkal 19 66kV Doddakari 19 66kV Honganur 19 66kV Hangal
20 110KV Halakundi 20 110kV Hirebagewadi 20 110kV Karkal 20 66kV Dommasandra 20 66kV Hunsur 20 66kV Hebbur
21 110kv Hallikhed 21 110kV Hukkeri 21 110kV Kavoor 21 66kV Ganjigunte 21 66kV Iglur 21 66kV Hirehalli
22 110kV Harekrishna 22 110kV Hunagund 22 110kV Kemar 22 66kV Gowribidanur 22 66kV Jakkanahalli 22 66kV Honnenahalli
23 110kV Ilkal 23 110kV Ilkal 23 110kV Konaje 23 66kV Gudibande 23 66kV K Hunalgere 23 66kV Honnudike
24 110kV Janwada 24 110kV Jamakhandi 24 110kV Konanduru 24 66kv Gundamgere 24 66kV Kadabhalli 24 66kv Idhalli
25 110kV Jawalgera 25 110kV Kadakalat 25 110kV Kortigere 25 66kv Gundamgere 25 66kV Kalamandir 25 66kV Javagondanahalli
26 110KV Kamalapura 26 110kV Kalaghatti 26 110kV Kulashekara 26 66kV Hosapalya 26 66kV Karadilkkinakere 26 66kV Jiddigere
27 110kV Kamalnagar 27 110kV Kataraki 27 110kV Kumsi 27 66kV Hoskote 27 66kV Karya 27 66kV Kallambella
28 110kV Kampli 28 110kV Kavalwad 28 110kV Lingadahalli MUSS(DVG 28 66kV Irgampalli 28 66kV Kasalgere 28 66kv Kodigenahalli
29 110kV Kamthana 29 110kV Kerur 29 110kV LPH (G) 29 66kV Iskon 29 66kV KIADB Manya 29 66kV Kora
30 110kV Karatagi 30 110kV KIADB Vijaypura 30 110kV Mavali 30 66kV Jadigenahalli 30 66kV KIADB Somanahalli 30 66kV Kukawada
31 110kV Kerehalli 31 110kV Kirawatti 31 110kV MGHE Jog(G) 31 66kV Jigani Link Road 31 66kV Kollegala 31 66kV Lingadahalli
32 110kV Konkal 32 110kV Kittur 32 110kV Moodabidri 32 66kV Kachmaranahalli 32 66kV Maddur 32 66kV Melekote
33 110kv Korwar Temple 33 110kV Konnur 33 110kV Muttinakoppa 33 66kV Kamasamudra 33 66kV Madikere 33 66kV Midigeshi
34 110KV Kuduthini 34 110kV KUD 34 110kV Ripponpete 34 66kV KGF 34 66kV Mamballi 34 66kV Mylanahalli
35 110KV Kurdi Cross 35 110kV Kudal Sangama 35 110kV Sagara 35 66kV KHBDC 35 66kV Mandya 35 66kV Nandhihalli cross
36 110kV Kurgod 36 110kV Kulageri Cross 36 110kV Salethur 36 66kV Kodigehalli 36 66kV Metgally 36 66kV Parashuramapura
37 110kV Kurkuntta 37 110kV Kulenur 37 110kV Sirsi 37 66kV Kyasamballi 37 66kV Mysuru South 37 66kV Pavagada
38 110kv Ladha 38 110kV Kumta 38 110kV Soraba 38 66kv M Gollahalli 38 66kV Nangamangala 38 66kV Sanikere
39 110KV M. Kollur 39 110kV Lakkamanahalli 39 110kV Talaguppa 39 66kV Magadi 39 66kV Panyadahundi 39 66kV Shylapura
40 110kV Madlapur 40 110kV Mache 40 110kV Thirthahalli 40 66kV Malur 40 66kV Ponnampete 40 66kV Tavaregere
41 110kV Mahagaon 41 110kV Manthur 41 110kV Thogarsi 41 66kV MalurI/A 41 66kV Rajivnagara 41 66kV Thimmasandra
42 110kV Mallapura 42 110kV Moratagi 42 110kV Ulavi 42 66kv Manchenahalli 42 66kV Sathegala 42 66kV Thippur
43 110kv Mandewal 43 110kV Muddebihal 43 110kV Vittla 43 66kV Mandekal 43 66kV Shimsha 43 66kV Thovinakere
44 110kV Manthal 44 110kV Mukarthihal 44 66kV (Salgame )Ugane 44 66kv Nandini Layout 44 66kV Srirangpatna 44 66kV TMTP
45 110kV Manvi 45 110kV Mundargi 45 66kV Bandishettyhally 45 66kV Nelamangala 45 66kV Sunkathannur 45 66kV Tyavanigi
46 110kV Margutti 46 110kV Mundgod 46 66kV Beluru 46 66kV Peenya 46 66kV Vaderahalli 46 66kV Vijaypura
47 110KV Moka 47 110kV Nandihal 47 66kV Belvadi 47 66kV Peresandra 47 66kV VC Farm 47 66kV VV Pura
48 110kV Moratagi 48 110kV Naregal 48 66kV Bhadra Generating station 48 66kV Platinum City 48 66kV Virajpete 48 66kV Yadiyur
49 110kV Mukunda 49 110kV Navalagi 49 66kV Bychanahally 49 66kV Rajankunte 49 66kV Yalandur
50 110kV Mundargi 50 110kV Navalgund 50 66kV Chikkabommenahally 50 66kV Remco 50 66kV Yediyur
51 110kV Munirabad 51 110kV Navanagar 51 66kV Chikkamagaluru 51 66kV RRNagara 51 66kV Yethambadi
52 110kV Obajjihalli 52 110kV Neerabhudihal 52 66kV Didiga 52 66kV Sadali
53 110kV PD Halli 53 110kV Nehrunagar (Belgaum) 53 66kV Hangaralli 53 66kV SM mangala
54 110kV RaichurIstckt(MKOLLUR) 54 110kV Nidagundi 54 66kV Hiremagaluru 54 66kV Soladevanahally
55 110kV Rajeshwar 55 110kV Nippani 55 66kV Hirisave 55 66kV Subramanyapura
56 110KV RBSSNEHT 56 110kV PHC 56 66kV Juttanahally 56 66kV Sugutur
57 110KV Sanklapura 57 110kV Raibagh 57 66kV Kanagal 57 66kV T.G.Halli
58 110kV Santhpur 58 110kV Ramankoppa 58 66kV Karadilakkanakere 58 66kV Tavarekere
59 110kv Sastapur 59 110kV Rampur 59 66kV KIADB Hassan 59 66kV Tekal
60 110KV Sathavahana (IPP) 60 110kV Ron 60 66kV Kudligere 60 66kV VG Doddi
61 110kV Shivapura WW S/S 61 110kV Sambhapur Road 61 66kV Kudligere MUSS (DVG 61 66kV Vijayanagar
62 110KV Sindhanur 62 110kV Savanur 62 66kV Kundurumatta 62 66kV Vokkaleri
63 110kV Sirigere Cross 63 110kV Shedbal 63 66kV Lingadahalli
64 110kV Siriguppa 64 110kV Shigikeri 64 66kV Mallenahalli
65 110kV Sreeramnagar 65 110kV Shirol 65 66kV Mattanavile
66 110kV Talakal 66 110kV Sindagi 66 66kV Mavinakatte
67 110kV Thekalkote 67 110kV Sultanpur 67 66kV MRS Shivamogga
68 110kV Toranagallu 68 110kV Sulthapural 68 66kV Ramanathapura
69 110kV Walaballari 69 110kV Supa 69 66kV RM Nagara
70 110KV Walkamdinni 70 110kV Suvarna Souda 70 66kV Rudrapatna
71 110kv Yadgir 71 110kV Tarihal 71 66kV Sathenahally
72 110kV Yerdona 72 110kV thorvi 72 66kV Seegebagi
73 66kV Byggwwat 73 110kV Tiluvalli 73 66kV Shanthigrama
74 66kV Chilakanahalli 74 110kV tokota 74 66kV Shettihalli
75 66kV Chilakanahatti 75 110kV Ukkali 75 66kV Udayapura
76 66kV Gudikote 76 110kV Umachagi 76 66kV Ugani
77 66kV Hanasi 77 110kV Vadagoan
79 66kV Harapanahalli
80 66kV HB Halli
81 66kV Kudalgi
82 66kV Munirabad
83 66kV RR Steel
85 66kV Upanayakanahalli
86 66kV Yeragunta
Sl No Zone Division TLM Subdivision Voltage Class Name of the Line Route Length in Kms
1 Mysuru 66kV 220kV Chamrajnagara- 66kV Pannyadahundi 10.72
2 Mysuru 66kV 66kV Panyadahundi- 66kV Karya 14.62
3 Mysuru 66kV 66kV Karya- 66kV Hemmergala 15.9
4 Mysuru 66kV 66kV Hemmergala-66kV Devanur N gudu 5.11
5 Mysuru 66kV 66kV Devnur N gudu- 66kV Goluru 6.7
6 Mysuru 66kV 66kV Goluru- 220kV Kadkola 16.6
7 Mysuru 66kV 220kV Kadkola- 66kV Mysuru South 10.4
8 Mysuru 66kV 66kV Mysuru South- Kalamandir 9.59
9 Mysuru 66kV 66kV Kalamandir- 66kV Bogadhi 3.66
10 Mysuru 66kV 66kV Bogadhi- 220kV Hootgally 4.49
11 Mysuru 66kV 220kV Hootgally- 66kV Elvala 12.3
12 Mysuru 66kV 66kV Elvala- 66kV Hunsur 35.9
13 Mysuru 66kV 66kV Hunsur- 220kV Hunsur 6.49
14 Mysuru 66kV 220kV Hunsur- 66kV Hanagodu 14.19
15 Mysuru 66kV 66kV Hanagodu- 66kV Ponnapete 34.3
16 Mysuru 66kV 66kV Ponnampete- 66kV Virajpete 18.3
17 Mysuru 66kV 66kV Virajpete-66kV Madikere 37.38
18 Mysuru 66kV 66kV Madikere- 220kV Kushalnagara 28.5
19 Mysuru 66kV 220kV Hootgally- 66kV Bannimantapa 10.5
20 Mysuru 66kV 66kV Bannimantapa- 66kV FTS 3.6
21 Mysuru 66kV 66kV FTS- 66kV Rajivnagara 8.215
22 Mysuru 66kV 66kV Rajivnagara- 66kV Devanur (Mysuru) 2.215
23 Mysuru 66kV 66kV Devanur (Mysuru) - 220kV Vajmangala 7.36
24 Mysuru 66kV 220kV Vajmangala- 66kV Bannur 14.84
25 Mysuru 66kV 66kV Bannur- 220kV Hebbani 10.12
26 Mysuru 66kV 220kV Hebbani - 66kV Sathegala 10.67
27 Mysuru 66kV 66kV Sathegala- 66kV Kollegala 15.79
28 Mysuru 66kV 66kV Kollegala- 220kV Chamrajnagara 31.7
29 Mysuru 66kV 220kV Hootgally- 66kV Hebbal 2.925
30 Mysuru 66kV 66kV Hebbal- 66kV Metgally 2.725
31 Mysuru 66kV 66kV Metgally- 66kV Srirangpatna 12.4
32 Mysuru 66kV 66kV Srirangpatna- 66kV G Ukkada 7
33 Mysuru 66kV 66kV G Ukkada- 220kV Tubinkere 9.6
34 Mysuru 66kV 220kV Tubinkere- 66kV Mandya 10.5
35 Mysuru 66kV 66kV Mandya- 66kV Maddur 20.9
36 Mysuru 66kV 66kV KIADB Manya LILO 2.9
37 Mysuru 66kV 66kV Maddur- 66kV KIADB Somanahalli 9.3
38 Mysuru 66kV 66kV KIADB Somanahalli- 66kV K Hunalgere 13.4
39 Mysuru 66kV 66kV K Hunalgere- 66kV Iglur 10.9
40 Mysuru 66kV 66kV Iglur- 66kV Yethambadi 26.9
41 Mysuru 66kV 66kV Yethambadi- 220kV TK Halli 26.23
42 Mysuru 66kV 220kV Tubinkere- 66kV VC Farm 19.232
43 Mysuru 66kV 66kV VC Farm- 220kV Nagamangala 53.91
44 Mysuru 66kV 66kV Nangamangala-Kasalgere 7.6
45 Mysuru 66kV 66kV Nagamangala-G.Malligere-Jakkanahalli 1.41
46 Mysuru 66kV 66kV NagamangalaR/S-Bhogadhi-Guddenahalli 17.39
47 Mysuru 66kV 220kV TK Halli- 66kV Shimsha 9.7
48 Mysuru 66kV 66kV Shimsha- 220kV Hebbani 9.103
49 Mysuru 66kV 220kV Nagamangala- 66kV BG Nagara 24.51
50 Mysuru 66kV 66kV BG Nagara- 66kV Kadabhalli 11.5
51 Mysuru 66kV 66kV Kadabhalli- 66kV Hirisave 11.3
52 Mysuru 66kV 220kV Kushalnagara- 66kV Karadilkkinakere Tap Point 36.85 7
53 Mysuru 66kV 66kV Yalandur-Mamballi 3.07
54 Mysuru 66kV 66kV BG Nagara- 66kV AC Giri-66kV Vaderahalli 18.6
55 Mysuru 66kV 66kV Vaderahalli- 66kV Yediyur 10.7
Sl No Zone Division TLM Subdivision Voltage Class Name of the Line Route Length in Kms
1 Hassan 66kV Karadilakkanakere to Ramanathapura with tap Rudrapatna, Chikkabommenahally & Kanagal 34.63
2 Hassan 66kV 66kV Ramanathapura- 66kV Belvadi 12.74
3 Hassan 66kV 66kV Belvadi - 220kV HN Pura 21.66
4 Hassan 66kV 220kV HN Pura - 66kV Hangaralli 10.4
5 Hassan 66kV 66kV Hangaralli - 220kV Hassan 20.5
6 Hassan 66kV 220kV Hassan- 66kV Ugani 12.561
7 Hassan 66kV 66kV (Salgame )Ugane- 66kV Beluru- 66kV Mugulvalli (Chikmagalur 220) 31.2
8 Hassan 66kV 66kV Mugulvalli (Chikmagalur 220) - 66kV Hiremagaluru 1.02
9 Hassan 66kV 66kV Hiremagaluru- 66kV Chikmagaluru 8.8
10 Hassan 66kV 66kV Chikkamagaluru-66kV Mallenahalli 12.25
11 Hassan 66kV 66kV Mallenahalli-66kV Lingadahalli-2 21
12 Hassan 66kV 66kV Bhadra Generating station-66kV Lingadahalli-2 21
13 Hassan 66kV 66kV Bhadra Generating station-220kV MRS Shivamogga 5
14 Hassan 110kV 220kV MRS Shivamogga- 110kV Alkola 23
15 Hassan 110kV 110kV Alkola-Ripponpete-Sagara 75.76
16 Hassan 110kV 110kV Sagara- 110kV Talaguppa 13
17 Hassan 110kV 110kV Talaguppa- LPH (G) 15
18 Hassan 110kV LPH (G)- 110kV Jog 12
19 Hassan 110kV 110kV Jog- MGHE Jog(G) 1
20 Hassan 110kV MGHE Jog(G)-110kV Sirsi 3
21 Hassan 66kV 66kV Mattanavile - Didiga - Juttanahally - 66kV Hirisave 29
22 Hassan 66kV 66kV Mattanavile - Shettihalli- 220kV CR Patna 36.04
23 Hassan 66kV 220kV CR Patna- 66kV Udayapura 10.63
24 Hassan 66kV 66kV Udayapura- 66kV Shanthigrama 14.8
25 Hassan 66kV 66kV Shanthigrama- 66kV RM Nagara 19.469
26 Hassan 66kV 66kV RM Nagara- 66kV KIADB Hassan 9.339
27 Hassan 66kV 66kV KIADB Hassan- 220kV Hassan 4.3
28 Hassan 110kV 220kV Shivamogga- 110kV Gajanur 11
29 Hassan 110kV 110kV Muttinakoppa- 110kV Gajanur 18
30 Hassan 110kV 110kV Muttinakoppa- 110kV Bejavalli 18
31 Hassan 110kV 110kV Bejavalli-Konanduru- 110kV Thirthahalli 22
32 Hassan 110kV 110kV Thirthahalli - Kammaradi - Mani Generating station - Hulikal 54
33 Hassan 110kV 110kV Hulikal- 110kV Hosangadi 23
34 Hassan 110kV 110kV Hosangadi- 110kV Haladi 15.5
35 Hassan 110kV 110kV Haladi-Heggunje 9.53
36 Hassan 110kV 110kV Heggunje to Hiriyadka 19.8
37 Hassan 110kV 110kV Karkal-Hiriyadka 18.82
38 Hassan 110kV 110kV Kemar-Karkal 5.52
39 Hassan 110kV 110kV Kemar -Moodabidri 15.5
40 Hassan 110kV 110kV Moodabidri-Gurupura 17.24
41 Hassan 110kV 220kV Kavoor-Gurupura 9.51
42 Hassan 110kV 110kV Kavoor-Kulashekara-Jeppu-Konaje 30.59
43 Hassan 110kV 110kV Konaje - Salethuru 15.4
44 Hassan 110kV 110kV Vittla- Salethur 10.2
45 Hassan 110kV 220kV Puttur (Netlamudnur) -Vittla 13.9
46 Hassan 66kV 66kV MRS Shivamogga - Seegebagi MUSS - DVG2 16
47 Hassan 66kV 66kV Seegebagi - Kudligere MUSS (DVG-2) 11
48 Hassan 66kV 66kV Kudligere - Anveri Mini Hydel IPP - Mavinakatte MUSS - Lingadahalli MUSS(DVG-2) 10
49 Hassan 110kV 110kV Balligavi-Thogarsi-Anavatti 35.73
50 Hassan 110kV 110kV Bharangi- 110kV Kortigere_220kV Balligavi (Shiralkoppa) 25.7
51 Hassan 110kV 220kV Balligavi (Shiralkoppa)- 110kV Mavali 13
52 Hassan 110kV 110kV Mavali- 110kV Soraba 11
53 Hassan 110kV 110kV Soraba- 110kV Ulavi 13
54 Hassan 66kV Udayapura-Kundurumatta-Sathenahally 13.21
55 Hassan 110kV Ayanur-Kumsi 0.11
56 Hassan 66kV Bandishettyhally-Bychanahally-Ramanathapura 27.82
57 Hassan 110kV 110kV Ulavi- 110kV Sagar 15
Sl No Zone Division TLM Subdivision Voltage Class Name of the Line Route Length in Kms
1 Tumkur 66kV 66kV Lingadahalli- 66kV Basavapatna- 220kV Honnali 38.007
2 Tumkur 66kV 66KV Kukkawada-Tyavanigi-Basavapttana line 28.14
3 Tumkur 66kV 66kV Kukawada- 220kV SRS Davangere 13.66
4 Tumkur 66kV 220kV Anchepalya-Jiddigere-Thippur 25.325
5 Tumkur 66kV 66kV Thippur-Yadiyur 4.735
6 Tumkur 66kV 66kV Anchepalya220-Anchepalya66-1 1.589
7 Tumkur 66kV 220kV Anchepalya-Anchepalya 66-Hebbur 24
8 Tumkur 66kV 66kV Anchepalya66-Bhaktharahalli-Hebbur 2.32
9 Tumkur 66kV 66kV Hebbur-Thimmasandra-Honnenahalli 25.1
10 Tumkur 66kV 66kV Honnenahalli-Doddasarangi 10.5
11 Tumkur 66kV 220kV Antharasanahalli-Bellavi-Doddasarangi-Heggere 16.065
12 Tumkur 66kV 66kV Antharasanahalli-Melekote 13.65
13 Tumkur 66kV 66kV Melekote-Baddihalli 6.444
14 Tumkur 66kV 66kV Hirehalli-Honnudike-Baddihalli 22.786
15 Tumkur 66kV 66kV Hirehalli- 220kV Dabaspete 4.4
16 Tumkur 66kV 220kV Antharasanahalli-66kV Kora 29.425
17 Tumkur 66kV 66kV TMTP-Kora-Bramhasandra 36.025
18 Tumkur 66kV 66kV Bramhasandra-Kallambella-Ankasandra 30.8
19 Tumkur 66kV 66kV Antharasanahalli-Nandhihalli cross-Chelur 16.61
20 Tumkur 66kV 66kV Bramhasandra-Chelur 0.44
21 Tumkur 66kV 66kV Sira66-Kallambella 26.4
22 Tumkur 66kV 66kV Sira220-Sira66-1 2.3
23 Tumkur 66kV 220kV Sira - 66kV Tavarekere 13
24 Tumkur 66kV 66kV Tavaregere- 66kV Javagondanahalli- 220kV Hiriyuru SRS 35
25 Tumkur 66kV 220kV Hiriyur- 66kV Sanikere 28.5
26 Tumkur 66kV 66kV Sanikere- 66kV Chalkere 19.5
27 Tumkur 66kV 66kV Chalkere- 66kV Balenahalli 13
28 Tumkur 66kV 66kV Balenahalli- 220kV Chitradurga 16.5
29 Tumkur 66kV 220kV Chitradurga-66kV Vijaypura 24.7
30 Tumkur 66kV 66kV Vijaypura-66kV Brahmasagara- 66kV Avargere 27
31 Tumkur 66kV 66kV Avargere- 220kV SRS Davangere 3.25
32 Tumkur 66kV 220kV Thallak-66kV BG Kere- 66kV Hangal 34.5
33 Tumkur 66kV 220kV Thallak- Mylanahalli- 66kV VV Pura 40.91
34 Tumkur 66kV 66kV VV Pura- 66kV Dyavaranahally 12.01
35 Tumkur 66kV 66kV Dyavarahalli- 66kV Parashuramapura 35
36 Tumkur 66kV 66kV Parashuramapura- 66kV Lingadahalli 16.5
37 Tumkur 66kV 66kV Lingadahalli- 66kV Shylapura 9
38 Tumkur 66kV 66kV Shylapura- 220kV Pavagada 8.75
39 Tumkur 66kV 66kV Pavagada- 220kV Pavagada 5.225
40 Tumkur 66kV 66kV Pavagada- 66kV Midigeshi 41.75
41 Tumkur 66kV 66kV Midigeshi-66kv Idhalli 17
42 Tumkur 66kV 66kv Idhalli-66kv Kodigenahalli 17
43 Tumkur 66kV 66kV TMTP-Thovinakere 3.6
44 Tumkur 66kV 66kv Kodigenahalli-66kv Gowribidnur 6
Sl No Zone Voltage Class Name of the Line Route Length in Kms
1 Gulbarga 66kV 66kV Hangal- 66kV Gudikote 34
2 Gulbarga 66kV 66kV Gudikote- 220kV Kudalgi (Badeladaku) 31.25
3 Gulbarga 66kV 220kV Kudalgi- 66kV Kudalgi 4.8
4 Gulbarga 66kV 66kV Kudalgi- Shivapura WW S/S- 8.75
5 Gulbarga 66kV Shivapura WW S/S- 66kV Hanasi 6.25
6 Gulbarga 66kV 66kV Hanasi- 66kV Chilakanahatti 12.4
7 Gulbarga 66kV 66kV Chilakanahalli- 66kV Munirabad 26.4
8 Gulbarga 66kV 220kV Davangere- 66kV Yeragunta 6.12
9 Gulbarga 66kV 66kV Yeragunta- Obajjihalli- 66kV Telagi 28.39
10 Gulbarga 66kV 66kV Telagi- 220kV Neelgunda 9.53
11 Gulbarga 66kV 220kV Neelgunda- 66kV Harapanahalli 0.62
12 Gulbarga 66kV 66kV Harapanahalli- 220kV Ittagi 23.5
13 Gulbarga 66kV 220kV Ittagi- 66kV HB Halli 18.28
14 Gulbarga 66kV 66kV HB Halli- 66kV Upanayakanahalli 11.1
15 Gulbarga 66kV 66kV Upanayakanahalli- 66kV RR Steel 5.25
16 Gulbarga 66kV 66kV RR Steel- 66kV Munirabad 28.35
17 Gulbarga 110kV 110kV Munirabad- 110kV Harekrishna EHT 12.1
18 Gulbarga 110kV 110kV Harekrishna- 220kV Koppal 4.76
19 Gulbarga 110kV 220kV Koppal- 110kV Talakal 26.86
20 Gulbarga 110kV 110kV Halvarthy220-Ginigera 2.89
21 Gulbarga 110kV 110kV Talakal- 110kV Betagera 23.38
22 Gulbarga 110kV 110kV Betagera- 110kV Mundargi 13
23 Gulbarga 110kV 220kV Munirabad- 110kV Mallapura 29.6
24 Gulbarga 110kV 110kV Munirabad220-Kerehalli-Mallapura 6.31
25 Gulbarga 110kV 110kV Mallapura- 220kV Gangavathi 13.5
26 Gulbarga 110kV 110KV Mallapura MUSS-Kampli-Sulekal220 9.04
27 Gulbarga 110kV 110kV Sindhanur220-Mukunda-Yerdona-KPCL Maralihalla 18.06
28 Gulbarga 110kV 220kV Gangavathi- 110kV Sreeramnagar 20.89
29 Gulbarga 110kV 110kV Sreeramnagar-110kV Karatagi- 220kV Sindanoor 26.5
30 Gulbarga 110kV 220kV Munirabad - 110KV Sanklapura 17.5
31 Gulbarga 110kV 110KV Sanklapura- 110KV RBSSN EHT 2.2
32 Gulbarga 110kV 110KV RBSSN EHT to 110KV Kamalapura 9.3
33 Gulbarga 110kV 110KV Kamalapura-Toranagallu 30.3
34 Gulbarga 110kV 110KV Toranagallu- 110KV Kuduthini 25.47
35 Gulbarga 110kV 110KV Kudithini MUSS to 110KV Sathavahana IPP 6.97
36 Gulbarga 110kV 110KV Sathavahana (IPP) to 110kV KIADB 18.3
37 Gulbarga 110kV 220KV Allipura- 110KV KIADB 10.1
38 Gulbarga 110kV 220kV Allipura- 110kV Kurgod- 110kV Sirigere Cross 28.978
39 Gulbarga 110kV 110kV Sirigere Cross- 110kV Thekalkote 15.42
40 Gulbarga 110kV 110kV Thekalkote- 110kV Siriguppa 16
41 Gulbarga 110kV 110kV Siriguppa- 110kV Dadesugur 12.2
42 Gulbarga 110kV 110KV Sindhanur 220 - dhadesugur SC 24.73
43 Gulbarga 110kV 110KV Ballari South - 220KV Allipura 7
44 Gulbarga 110kV 110KV Halakundi- 110KV Ballari South 3.23
45 Gulbarga 110kV 110KV Bislahalli- 110KV Halakundi 7.15
46 Gulbarga 110kV 110kV Bislahalli- 110kV Moka Tap 12.5
47 Gulbarga 110kV 110kV Ballari North-Bislahalli-PD Halli 19.27
48 Gulbarga 110kV 220KV Somasamudra-110KV Moka 20.88
49 Gulbarga 110kV 220kV Sindhanur - 110KV Sindhanur 12.66
50 Gulbarga 110kV 110KV Sindhanur-Walkamdinni 21
51 Gulbarga 110kV 110KV Walkamdinni-Byggwwat 17
52 Gulbarga 110kV 110kV Bygwat- 220KV Mallat 16
53 Gulbarga 110kV 220 kV Mallat -adavi amareshwar-Manvi-Madlapur 53.7
54 Gulbarga 110kV 110KV Kurdi Cross -Madlapur 22.2
55 Gulbarga 110kV 110KV Raichur 220-Kurdi cross 22.85
56 Gulbarga 110kV 110KV M. Kollur - 220KV Raichur 62.61
57 Gulbarga 110kV 220kV Shahapur-110kV Raichur I st ckt ( M KOLLUR ) 9.52
58 Gulbarga 110kV 220kV Shahapur-110kV Yadgir 43
59 Gulbarga 110kV 110kv Yadgir- 220Kv Ramsamudra 23.44
60 Gulbarga 110kV 220KV Ramsamudra- 110kV Konkal 28.44
61 Gulbarga 110kV 110kV Konkal-110kV Gurmitkal 17.5
62 Gulbarga 110kV 220kV Sedam-110kV Gurmitkal line 37.18
63 Gulbarga 110kV 220kV Sedam -110kVChitapur (Tapping to South India Cement) 26.4
64 Gulbarga 110kV 110kv Korwar Temple -Chittapur 33.3
65 Gulbarga 110kV 110kv Shahabad 220-Korwar Temple 36.7
66 Gulbarga 110kV 110kv Shahabad 220 - GlB Univercity 28.5
67 Gulbarga 110kV 110kVGlb North-110kV GlB Univercity II 11
68 Gulbarga 110kV 220kV Kapnoor-Gulbarga (North)-I 8
69 Gulbarga 110kV 220kV Kapnoor-110kV Margutti (Tap-Mahagaon) 38
70 Gulbarga 110kV 110kv Humnabad 220 -Margutti 14.4
71 Gulbarga 110kV 110kv Humnabad 220 -Hallikhed 22.9
72 Gulbarga 110kV 110kv Hallikhed - Halbarga 220 22.06
73 Gulbarga 110kV 110kv Halbarga 220 -Santhpur 51
74 Gulbarga 110kV 110 kv Santhpur - Aurad 16.3
75 Gulbarga 110kV 110 kv Aurad - Dongargaon 12.5
76 Gulbarga 110kV 110 kv Dongargaon -Kamalnagar 14.5
77 Gulbarga 110kV 110 kv Ladha- Kamalnagar 26.79
78 Gulbarga 110kV 110kv Ladha-Sastapur 32
79 Gulbarga 110kV 110kv Sastapur- Manthal 10
80 Gulbarga 110kV 110kv Rajeshwar - Sastapur 14
81 Gulbarga 110kV 110kV Jawalgera-Adavi Amreshwara 14.65
82 Gulbarga 110kV 110kV Walaballari-Jawalgera 12.37
83 Gulbarga 110kV 110kV Raichur220-Gugal-Devadurga-Gabbur-2 46.59
84 Gulbarga 110kV 110kV Janwada-Santhpur 20.91
85 Gulbarga 110kV 110kv Humnabad 220- Rajeshwar 12
86 Gulbarga 110kV 220kV Sedam-110kV Kurkuntta 18
87 Gulbarga 110kV 110kv Halbarga 220 -Kamthana 12.7
88 Gulbarga 110kV 110 kv Kamthna- Habsikote 12.7
89 Gulbarga 110kV 110 kv Habsikote - chidri 11.5
90 Gulbarga 110kV 110kv Shahabad 220-Mandewal (B-1) 47.1
91 Gulbarga 110kV 110kv Mandewal-Moratagi 12
92 Gulbarga 110kV 220kV Kushtagi- 110 Ilkal 24.6
Sl No Zone Division TLM Subdivision Voltage Class Name of theLine Route Length in Kms
1 Bengaluru 66kV 66kV Peenya - Byadarahalli 8.239
2 Bengaluru 66kV 66kV Byadarahalli - Kodigehalli 3.669
3 Bengaluru 66kV Tavarekere-Kodigehalli 6.82
4 Bengaluru 66kV 66kV T.G.Halli-BWSSB TG Halli-Tavarekere 6.85
5 Bengaluru 66kV 66kV Tubinkere-VG Doddi-TG Halli 31.1
6 Bengaluru 66kV 66kV Tubinkere -Magadi Line-Hosapalya-Anchepalya commissioned on 07.01.2022 32.862
7 Bengaluru 66kV 66kV Peenya - Nandini Layout 2.987
8 Bengaluru 66kV 66kV Nandini Layout - NRS 3.086
9 Bengaluru 66kV 66kV NRS 220 - Vijayanagar 3.578
10 Bengaluru 66kV 66kV Remco - Vijayanagar 5.4
11 66kV 66kV Tekal - Budikote 13.97
12 66kV 66kV KGF - Kamasamudra 13.08
13 66kV 66kV Kyasamballi - Doddakari 6.53
14 66kV 66kV KGF - Andersonpet Tap point 7.05
15 66kV 66kV Jadigenahalli - Hoskote 6.24
16 66kV 66kV Malur 220 - Malur I/A - Jadigenahalli (Hoskote -1) 32.66
17 66kV 66kV Irgampalli - Burudagunte 12.5
18 66kV 66kV Irgampalli - M Gollahalli 4.91
19 Bengaluru 66kV 66kV Subramanyapura - Remco 2 - RR Nagara - Global (EHT) 11.09
20 Bengaluru 66kV 220kV Subramanyapura- 66kV Iskon
21 Bengaluru 66kV 66kV Iskon- 220kV Somanahalli 13
22 Bengaluru 220kV 220kV Somanahalli - BWSSB Harohalli 18.02
23 Bengaluru 220kV 220kV BWSSB Harohalli - KIADB Harohalli 5.5
24 Bengaluru 66kV 66kV T.K Halli 220-KIADB Harohalli 220 39.61
25 Bengaluru 66kV 66kV Dabaspet - Nelamangala Ckt 1 21.56
26 Bengaluru 66kV 66kV Nelamangala -Alur 7.167
27 Bengaluru 66kV 66kV Peenya - Soladevanahally tap to BIEC and Alur DG - II 20.6
28 Bengaluru 66kV 220kV Gowribidnur- 66kV D Palya 13.12
29 Bengaluru 66kV 66kV D Palya- 66kV Gudibande-Mandekal 23.075
30 Bengaluru 66kV 66kV Mandekal- 66kV Peresandra 6.329
31 Bengaluru 66kV 66kV Dibburhalli - Sadali - Peresandra 24.563
32 Bengaluru 66kV 66kV Dibburhalli- 66kV Burudugunte- 66kV Ganjigunte 23.88
33 Bengaluru 66kV 66kV Ganjigunte- 220kV Chintamani 19.084
34 Bengaluru 66kV 220kV Chintamani- 66kV Chintamani 0.4
35 Bengaluru 66kV 66kV Chintamani- 66kV SM Mangala 14.43
36 Bengaluru 66kV 66kV SM mangala- Sugutur- 220kV Kolar 19.08
37 Bengaluru 66kV 220kV Kolar- 66kV Vokkaleri 10.76
38 Bengaluru 66kV 66kV Malur - Vokkaleri 1 - 66kV Hoskote 32.869
39 Bengaluru 66kV 66kV Hoskote- 220kV Hoddy 17.72
40 Bengaluru 66kV 66kV Gowribidanur -66 kvManchenahalli -66kv Gundamgere 46.516
41 Bengaluru 66kV 66kv Gundamgere - 66kV D Cross 17.691
42 Bengaluru 66kV 66kV D Cross -1 - 220kV DB Pura 1.853
43 Bengaluru 66kV 66kV D Cross- 66kV Air EHT- 66kV Rajankunte 25.758
44 Bengaluru 66kV 66kV Rajankunte- 220kV Yelahanka 11.035
45 Bengaluru 66kV 66kV DG1 Puttenahalli - KHB DC_SC 0.9
46 Bengaluru 66kV 66kV Peenya - KHB DG-1 21.85
47 Bengaluru 66kV 220kV Peenya- 66kV Platinum City 1.23
48 Bengaluru 66kV 66kV Platinum City- Attur- 220kV Sahakarnagara 15.32
49 Bengaluru 66kV 220kV Somanahalli- 66kV Bannerghatta Road 18.92
50 Bengaluru 66kV 66kV Bannerghatta Road- 66kV Jigani Link Road 9.8
51 Bengaluru 66kV 66kV Jigani Link Road- Jigani- 220kV Yerandanahalli 8.6
52 Bengaluru 66kV 220kV Yerandanahalli- 66kV Chandapura 4.5
53 Bengaluru 66kV 66kV Chandapura- 220kV Sarjapura 14.3
54 Bengaluru 66kV 220kV Sarjapura- 66kV Dommasandra 13.8
55 Bengaluru 66kV 66kV Dommasandra- 66kV Kachmaranahalli- 3.2
56 Bengaluru 66kV 66kV Kachmaranahalli- 66kV Divyashree Tech Park 8
57 Bengaluru 66kV 66kV Divyashree tech park - 220kV EPIP 1.4
58 Bengaluru 66kV 220kV Sarjapura- 66kV Attibele 11.3
59 66kV Malur 220 - Tekal - KGF 1 1.03
60 Bengaluru 66kV 220kV Malur-66kV Bangarpet- 66kV KGF 33.272
Sl No Zone Division TLM Subdivision Voltage Class Name of the Line Route Length in Kms
1 Bagalkot 110kV 110kV Dambal-Mundargi-1 & 2 18.17
2 Bagalkot 110kV 110kV Dambal- 110kV Sambhapur Road 18.95
3 Bagalkot 110kV 110kV Sambhapur Road- 220kV Gadag 8.73
4 Bagalkot 110kV 220kV Gadag- 110kV Betageri 11.8
5 Bagalkot 110kV 110kV Betageri- 110kV Naregal 24.8
6 Bagalkot 110kV 110kV Naregal- 110kV Ron 18.57
7 Bagalkot 110kV 110kV Ron- 110kV Gajendragad 24.9
8 110kV 110kV Hanumasagar-Gajendragada 5.87
9 Bagalkot 110kV 110kV Gajendragad- 220kV Kushtagi 25.5
10 Bagalkot 110kV 110 Ilkal- 110kV Hunagund 11.57
11 Bagalkot 110kV 110kV Hunagund- 110kV Kudal Sangama 20.8
12 Bagalkot 110kV 110kV Kudal Sangama- 110kV Rampur 9.64
13 Bagalkot 110kV 110kV Rampur- 110kV Nidagundi 38
14 Bagalkot 110kV 110kV Nidagundi- 110kV Mukarthihal 16.8
15 Bagalkot 110kV 110kV Mukarthihal- 220kV B Bagewadi 13.97
16 Bagalkot 110kV 220kV B Bagewadi- 110kV Achanur 38
17 110kV 110kV B Bagewadi-Muddebihal-Achanur 12
18 Bagalkot 110kV 110kV Achanur- 110kV Shigikeri 3.2
19 Bagalkot 110kV 110kV Shigikeri- 110kV Bagalkot 14.93
20 Bagalkot 110kV 110kV Bagalkot-220kV Bagalkot 10.75
21 Bagalkot 110kV 220kV Bagalkot- 110kV Neerabhudihal 12.27
22 Bagalkot 110kV 110kV Neerabhudihal- 110kV Kataraki 40.41
23 Bagalkot 110kV 110kV Kataraki- 220kV Vajramatti 14.27
24 Bagalkot 110kV 220kV Vajramatti- 110kV Manthur 9.89
25 Bagalkot 110kV 110kV Manthur- 110kV Shirol 8.79
26 Bagalkot 110kV 110kV Shirol-110kV Jamakandi 9.12
27 110kV 110kV Navalagi-Jamakhandi 12.28
28 Bagalkot 110kV 110kV Jamakandi- 220kV Mahalingpura 3
29 Bagalkot 110kV 220kV Mahalingpur-110kV Sulthapural 15
30 Bagalkot 110kV 110kV Sultanpur- 220kV Mughalkod 34.078
31 Bagalkot 110kV 220kV Mughalkod- 110kV Raibagh 23.44
32 Bagalkot 110kV 110kV Raibagh- 220kV Chikkodi 18
33 Bagalkot 110kV 220kV Chikkodi- 110kV Hukkeri 25.55
34 Bagalkot 110kV 110kV Hukkeri- 220kV Aques 30
35 Bagalkot 110kV 220kV Aques- 110kV Daddi 18.5
36 Bagalkot 110kV 110kV Daddi- 220kV Belgaum 42
37 Bagalkot 110kV 220kV Belgaum- 110kV Nehrunagar (Belgaum) 14.3
38 Bagalkot 110kV 110kV Nehrunagar (Belgaum)- 110kV Vadagoan 31.5
39 Bagalkot 110kV 110kV Vadagoan- 110kV Mache 12
40 Bagalkot 110kV 110kV Mache- 110kV Suvarna Souda 18.6
41 Bagalkot 110kV 110kV Suvarna Souda- 110kV Hirebagewadi 24
42 Bagalkot 110kV 110kV Hirebagewadi- 220kV MK Hubli 15.14
43 Bagalkot 110kV 220kV MK Hubli- 110kV Kittur 26.5
44 Bagalkot 110kV 110kV Kittur- 110kV Shedbal 5.75
45 Bagalkot 110kV 110kV Shedbal- 220kV Narendra 16.5
46 Bagalkot 110kV 220kV Narendra- 110kV KUD 8.95
47 Bagalkot 110kV 110kV KUD- 110kV Lakkamanahalli 5.5
48 Bagalkot 110kV 110kV Lakkamanahalli- 110kV Navanagar 9.5
49 Bagalkot 110kV 110kV Navanagar- 110kV Tarihal 7
50 Bagalkot 110kV 110kV Tarihal- 220kV Hubli 15.1
51 Bagalkot 110kV 220kV Hubli- 110kV Kalaghatti- 110kV Kavalwad 26
52 Bagalkot 110kV 110kV Haliyal-110kV Kavalwad- 110kV Kirawatti 49
53 Bagalkot 110kV 110kV Kiravatti- 110kV Umachagi 29.3
54 Bagalkot 110kV 110kV Umachagi- 110kV Esale 28.4
55 Bagalkot 110kV 110kV Esale- 220kV Sirsi 10
56 Bagalkot 110kV 110kV Haliyal- 220kV Ambewadi- 25.7
57 Bagalkot 110kV 220kV Ambewadi- 110kV Supa (Gen) 13.72
58 Bagalkot 110kV 110kV Supa- 110kV Anmod 40
59 Bagalkot 110kV 220kV Sirsi- 110kV Kumta 54
60 Bagalkot 110kV 110kV Kumta- 110kV Ankola 31.87
61 Bagalkot 110kV 110kV Ankola- 110kV Arga 23.85
62 Bagalkot 110kV 110kV Arga- 220kV Karwar 8.38
63 Bagalkot 110kV 220kV Chikkodi- 110kV Kadakalat 15
64 Bagalkot 110kV 110kV Kadakalat- 110kV Nippani 14
65 Bagalkot 110kV 220kV B Bagewadi- 110kV D. Hipperagi 32.99
66 Bagalkot 110kV 110kV D. Hipperagi - 110 Sindagi- 110kV Moratagi 20.47
67 Bagalkot 110kV 220kV B. Bagewadi- 110kV Nandihal 9.54
68 Bagalkot 110kV 110kV Nandihal- 110kV Ukkali 11.8
69 Bagalkot 110kV 110kV Ukkali- 220kV Vijaypura (Bijapur) 24.16
70 Bagalkot 110kV 220kV Vijaypura (Bijapur)- 110kV KIADB Vijaypura 7.1
71 Bagalkot 110kV 110kV KIADB Vijaypura- 110kV Butnal 9.5
72 Bagalkot 110kV 110kV Butnal- 110kV thorvi 17.07
73 Bagalkot 110kV 110kV thorvi- 110kV tokota 16.3
74 Bagalkot 110kV 220kV Hubli- 110kV Ramankoppa 20.5
75 Bagalkot 110kV 110kV Ramankoppa- 110kV Mundgod 12
76 Bagalkot 110kV 110kV Mundgod- 220kV Shiggoan 22.91
77 Bagalkot 110kV 220kV Shiggoan- 110kV Savanur 18.02
78 Bagalkot 110kV 110kV Savanur- 220kV Haveri 30.23
79 Bagalkot 110kV Haveri Kulenur Line 12.549
80 Bagalkot 110kV 110KV Kulenur-Chikkabasur Line ((From 16-01-2025) 17.338
81 Bagalkot 110kV 110 KVChikkabasur-Tiluvalli Line (From 16-01-2025) 12.825
82 Bagalkot 110kV 110kV Tiluvalli- 110kV Anavatti 15.2
83 Bagalkot 110kV 220kV Hubli- 110kV PHC 6
84 Bagalkot 110kV 110kV PHC- 220kV Bidnal 2.75
85 Bagalkot 110kV 220kV Bidnal- 110kV Navalgund 33
86 Bagalkot 110kV 110kV Navangund- 110kV Konnur 49.95
87 Bagalkot 110kV 110kV Konnur- 110kV Kulageri Cross 2.8
88 Bagalkot 110kV 110kV Kulageri Cross- 110kV Kerur 8.47
89 Bagalkot 110kV 110kV Kerur- 220kV Bagalkot 17.51
90 Bagalkot 110kV 110kV Gadagroad-Gopanakoppa 5.93
Karnataka Power Transmission Corporation Limited
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
TECHNO - COMMERCIAL SHEETS
NOTE* For detailed scope of the work please refer Bid Documents.
BIDDERS TO READ CAREFULLY
THE FOLLOWING DOCUMENTS [DULY SIGNED BY AUTHORISED PERSON, WHEREVER NECESSARY] ARE TO BE UPLOADED AND BANK GUARANTEE/INSURANCE SURETY BOND TOWARDS EMD OVER AND ABOVE RS.10.00LAKH AS PER ANNEXURE-III OF THE BID DOCUMENT SHALL BE SENT IN ORIGINAL TO CHIEF ENGINEER ELECTY., SLDC, KPTCL, BENGALURU SO AS TO REACH THIS OFFICE AFTER THE LAST DATE OF SUBMISSION OF BID AND ON OR BEFORE THE DATE & TIME NOTIFIED FOR OPENING OF TECHNO COMMERCIAL BIDS, FAILING WHICH THE BID WILL NOT BE OPENED. 1) NO DEVIATION CERTIFICATE (ANNEXURE-2). 2) EMD/BID SECURITY AS DETAILED IN CLAUSE NO. 12 of ITB. 3) BANK GUARANTEE issued either by a Nationalized/Scheduled Bank OR INSURANCE SURETY BOND issued by Insurance Company authorized by Insurance Regulatory and Development Authority of India (IRDA) TOWARDS BALANCE EMD/BID SECURITY. (For the balance EMD above Rs. 10.00Lakh) (ANNEXURE-3) - as detailed in Clause No. 12 of ITB-The Bidder shall scan the Bank Guarantee/INSURANCE SURETY BOND towards EMD and upload the same in the prescribed format in the slot specified for “EMD and Tender Fee Payments” in the e-procurement portal to enable the owner for verification of EMD BG/ISB at the time of opening of Techno Commercial Bid, failing which the offer will be rejected. 4) LETTER OF UNDERTAKING (ANNEXURE-6). 5) CONSORTIUM AGREEMENT (IF APPLICABLE) 6) POWER OF ATTORNEY (ANNEXURE-13). 7) ANY OTHER AGREEMENTS /UNDERTAKINGS/SELF DECLARATIONS SPECIFIED IN THE TENDER.
KARNATAKA POWER TRANSMISSION CORPORATION LIMITED
BID PROPOSAL SHEET
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
Bidder's Name & Address alongwith GSTIN no. :
Bid Proposal Reference :
Person to be contacted :
E-Mail Address:
The Chief Engineer, Electricity,
Anand Rao Circle, Bengaluru
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
a) * We have submitted bid as individual Bidder. (Indicate Name of the Individual Bidder)
b) * We have submitted bid in Consortium with the following Bidders. (Key in Consortium)
Name of the Consortium Partner Scope / Participation of each Consortium Partner
(* Fill-up whichever is applicable)
1 We, the undersigned Bidder, having read and examined in detail the specifications and all the Bidding documents of the said work and hereby propose to design, manufacture/fabricate, shop test, supply on FOR site basis, and carry out the erection, testing and commissioning including civil, structural and architectural works for
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
2 PRICES AND VALIDITY :
2.1 We declare that the Prices stated in our Proposal are in accordance with subject Bid Documents (including Clause No.10 of Instruction to Bidders (ITB) of Bid Documents). We further declare that all Ex-works price/CIF components of Spares, Maintenance and Testing Equipments and other charges viz., Freight and Insurance, Type Test charges and other charges stated in our proposal shall be as per the Tender conditions. All the Price and other terms and conditions of this Proposal are valid during the Performance of the Contract.
2.2 All Duties, such as Custom Duties on imports, Levies, Surcharge/Cess etc., if any applicable on the transaction excluding GST are included in the Bid Price and shall be to Our account and the Owner is not having any liability whatsoever on this account, whatever may be the contrary elsewhere in the Bid documents. However the component of Duties included in the Bid Price are separately indicated in Schedule - 2 for TDS purpose. We further confirm that our Bid Prices as quoted in Schedule-I, include all import Duties and levies including Licence fees lawfully payable by us on imported items and all other Duties and Levies applicable on Bought-out Components, Materials, Equipment and other items and confirm that any such Duties and Levies additionally payable shall be to our account. We further confirm that, no Sales Tax in any form shall be payable by Owner either for Bought-out items which are despatched by our Sub-Suppliers directly to the Project Site or for items Supplied directly by us. We confirm that, the Prices quoted by us are excluding GST.
2.3 We declare that we have noted and considered Clause No.09 of General Conditions of Contract (GCC ) of Bid Documents regarding Taxes and Duties and quoted our Prices accordingly. We further agree for TDS as per Statutory stipulations.
2.4 The Bid Prices, the Price components of the various items in our Scope of Supply, Erection including Testing & Commisisoning, Civil and Mandatory spares is quoted in Percentage wise Financial Bid in KPP Portal for this proposal..
3 CONSTRUCTION OF THE CONTRACT : We, declare that we are making the Offer for the entire Scope of the Package in accordance with Clause No.23.1 of Instruction to Bidders (ITB) of Bid Document.
4 We having studied Clause No.16.4 of Special Conditions of Contract (SCC ), Clause No. 9.2 of Instruction to Bidders (ITB) of Bid Documents , relating to Tax and we hereby, declare that if any income-tax, surcharge on income tax or any other corporate tax is attracted under the law, we agree to pay the same.
5 Bid Security/ EMD : We have enclosed a Bid Security through e-Payment mode for a sum of Rs.10.00Lakhs and remaining amount of Rs..........Lakhs ( above Rs.10.00 Lakhs) in the form of Insurance Surety Bond (ISB) issued by Insurance Company authorized by Insurance Regulatory and Development Authority of India (IRDA) OR in the form of Bank Guarantee in original valid for a period of 225 days from last date of bid submission and liable to be forfeited in accordance with Bid Documents. (Mode of Payment towards EMD is as detailed in CLAUSE NO. 12 of ITB)
We have also ensured that the above Bid Guarantee furnished by us is in line with the Bid Documents and complete in respect of following :
1. Value of Non judicial Stamp Paper purchased in the name of executing Bank is as per Stamp Act.
2. Power of Attorney Number and Date as well as Signature and Full Name and Designation of Executant along with Bank's Stamp are there.
3. Signature, Full Name, Designation and address of Witness are there.
4. Completed Mailing address of the Head Office of the Bank is indicated.
6.1 We declare that the Works shall be performed strictly in accordance with the Specifications and Documents except for the variations and Deviations, all of which have been detailed out exhaustively in the following Schedules, irrespective of whatever has been stated to the contrary anywhere else in our Proposal.
a Commercial Deviations Schedule Schedule - 5
b Technical Deviations Schedule Schedule - 6
6.2 We further confirm that Specified Stipulation of following Clauses are acceptable to us and No Deviation / Exceptions are taken on any account whatsoever in the following Clauses.
a. Terms of payment Clause No. 24 of Section-2, Instructions to Bidders (ITB)
b. EMD/Bid Security Clause No. 12, Section :2, Instructions to Bidders (ITB)
c. Contract Performance Guarantee Clause No. 28 of Section:2, Instructions to Bidders (ITB)
d. Penalty for delay Clause No. 10.2 of Section-4 : General Conditions of Contract (GCC).
e. Price Basis/ Price adjustment Clause No. 6 of Section-4 : General Conditions of Contract (GCC).
f. Defects Liability Period/Guarantee Clause No. 11 of Section-4 General Conditions of Contract (GCC)
g. Work Schedule Clause No.10.1 of Section:4 General Conditions of Contract (GCC) & Clause No.10 of Section:5 Erection Conditions of Contract (ECC)
h. Taxes and Duties Clause No. 9 of Section-4: General Conditions of Contract (GCC)
Further, we agree that additional conditions, if any, found in the Proposal Documents other than those stated in Deviation Schedules, save that pertaining to any rebates offered, shall not be given effect to.
7 PERFORMANCE GUARANTEE ; We declare that the ratings and performance figures of the equipment to be supplied and erected by us are guaranteed. The Guaranteed particulas of different equiment in our Scope are enclosed in Data Requirement Sheets.
8 BID PRICING : We further, declare that the Prices stated in our Proposal are in accordance with your ITB & all other relevant clauses of Bid Documents.
9 PRICE ADJUSTMENT : NA
10 SPECIAL TOOLS AND TACKLES : We have given a list of Special Tools and Tackles in Schedule - 7 and Prices thereof are included in our lumpsum Bid Price. We further agree that any items of Special Tools and Tackles, though not included in the aforesaid list, but required for effective Erection, Testing, Commissioning & Operation of the Equipments of Substations & Transmission lines shall also be furnished by us, at no extra cost to you.
11 ADDITIONAL INFORMATION : In addition to the information called for in these Proposal Sheets, we have included with this Proposal, additional information as listed in Schedule - 8. We further confirm that such additional information does not imply any additional deviation beyond those covered in Schedule - 5 & 6 and in case of any contraction between these additional information and other provisions of Bid, the later will prevail.
12 QUALIFICATION DATA : We confirm having submitted the Qualification Data, as required by you in your Bid Documents in e-Procurement Portal along with this Proposal. Further we have filled in the information for Qualification Requirements in Schedule 9. In case you require any further information in this regard, We agree to furnish the same in time.
13 WORK SCHEDULE : If this Proposal is accepted by you, we agree to submit Engineering Data, Provide Services and complete the entire Work from time to time, in accordance with Schedules indicated in the Proposal. We fully understand that the Time Schedule stipulated in this Proposal is the essence of the Contract, if awarded. The completion schedule of the various Major Key Phases of the Work is indicated in Schedule - 11.
14 CONTRACT PERFORMANCE GUARANTEE ; We further agree that if our Proposal is accepted, we shall provide an irrecoverable Contract Performance Guarantee, of value equivalent to Five percent (5%) of the Contract Price (Excluding GST) in accordance with Clause 28 of Instructions To Bidders (ITB) of the tender valid up to the end of ninety (90) days after the end of the Contract Guarantee Period mandatorily in the form of Insurance Surety Bonds (ISBs) issued by Insurance Company authorized by Insurance Regulatory and Development Authority of India (IRDA) (OR) in the form of electronic Bank Guarantee (e-BG) from the Banks which are integrated with NeSL in the form attached as Annexure-IV (Section 7: Formats of Annexures) in your favour and enter into a formal agreement with you within Twenty five (25) days from the date of issue of Letter of Intent to Award the Contract.
15 We, the partners of the Consortium whose Signatures are appended below, shall be liable jointly and severally for the execution of the Contract(s), in the event of Award, in accordance with the terms of Contract(s). The Lead Partner for this Bid - M/s .................................................................................... on behalf of the Consortium, is submitting the Bid. The Power of Attorney in favour of M/s .......................................................................................is enclosed.
16 BID PRICE : We declare that our lumpsum Price for the entire scope of work specified in the specifications and documents, shall be as indicated in Schedule - 1.
17 CHECK LIST : We have included a Checklist duly filled in Schedule 17
18 We, hereby, declare that only the Persons or Firms interested in this Proposal are named herein as Principals and that no other Persons are interested in the Proposal or in the Contract to be entered into, if we are awarded the Contract, and that this proposal is made without any connection with any other Person, Firm or Party likewise submitting a Proposal and that this Proposal is in all respect for and in good faith, without collusion or fraud.
19 We declare, in case our bid is accepted, that until a formal Contract is prepared & executed, this bid together with your written letter of acceptance thereof and your notification of award /Letter of Intent to Award the Contract shall constitute a binding contract between us. We further understand that you are not bound to accept the lowest or any bid you may receive.
Thanking you, we remain,
Yours faithfully,
Place Printed Name
Business Address Country of Incorporation (State or Province to be indicated)
Name and Address Principal Officer
Karnataka Power Transmission Corporation Limited
SHEET FOR TECHNO COMMERCIAL OPENING (Unpriced)
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
FILL ONLY IN LIGHT BLUE COLOURED CELLS.
Bidder's Name & Address alongwith GSTIN no. : To,
The Chief Engineer, Electy., SLDC, KPTCL Anand Rao Circle, Bengaluru - 560009
We declare that in terms of Clause No. 10 of ITB, Bid documents, the following are our lumpsum price in Rupees for the entire scope of work as specified in the Specifications and Documents.( Inclusive of all Taxes (Excluding GST) & Duties).
Total Lumpsum Price : ( In Figures) Note: Fill as "YES" against this column in case Prices are indicated in the Percentage-Wise Bid Financial Offer in figures
Place Designation
Name of the Company
Karnataka Power Transmission Corporation Limited
SCHEDULE - 2 (1 of 2)-SUMMARY OF PRICE COMPONENTS
SHEET FOR TECHNO COMMERCIAL OPENING (Unpriced)
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
FILL ONLY IN LIGHT BLUE COLOURED CELLS.
Summary of Price Components
Bidder's Name & Address alongwith GSTIN no. : To,
The Chief Engineer, Electy., SLDC, KPTCL Anand Rao Circle, Bengaluru - 560009.
Summary price components for identified in accompanying specifications
( Name of the Work) as per the scope identified in accompanying specifications.
Sl no Description Amount in Rs. (Fill as "YES" against the above Price columns in case Prices are indicated in the Price templates)
For Optical Ground Wire (OPGW) For Internet Protocol Multi-Protocol Label Switching (IP‑MPLS)
A Material / Equipment Price (including Packing & Forwarding charges) in the Scope of the Contractor
i) Ex-works including all taxes (Excluding GST) & duties [As per schedules - 3A(i) for OPGW & 3A(iI) for IP-MPLS
ii) Freight and Insurance Charges [As per schedules - 3A(i) for OPGW & 3A(iI) for IP-MPLS
iii) Total FOR site price (i+ii)
B Mandatory spares price (including packing & forwarding charges)
i) Ex-works including all taxes (Excluding GST) & duties(As per schedule - 4)
ii) Freight and Insurance Charges (As per schedule -4)
iii)Total FOR site price (i + ii)
C Buy back of released Ground Wire with Accessories
D Supply portion total FORD price [A(iii)+B(iii)-C]
E Erection portion:
i) Total charges for Erection, Testing & Commissioning of all Supply items [as per schedules-3B(i) for OPGW, 3B(ii) for IP-MPLS
ii) Total civil works, erection, Testing and commisioning charges (i)
F Total Bid Price = D+E(ii) In figures : Rs.
Total Bid Price in Figures : Rs.
Total Bid Price in words : Rupees
Place Designation
Name of the Company
Karnataka Power Transmission Corporation Limited
SCHEDULE - 2 ( 2 of 2 ) - TAXES(Excluding GST), DUTIES & OTHER LEVIES
SHEET FOR TECHNO COMMERCIAL OPENING (Unpriced)
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Fill IN LIGHT BLUE COLOURED CELLS.
Bidder's Name & Address alongwith GSTIN no. : To,
The Chief Engineer, Electy., SLDC, KPTCL, Anand Rao Circle, Bengaluru - 560009.
Estimates of Indian Taxes (Excluding GST), Duties and Levies included in the Total Bid Price are as follows:
SL. No. Description of Applicable Tax (Excluding GST) / Duty / Levy Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
Rate of Tax (Excluding GST)/ Duty / Levy Amount of Taxes (Excluding GST) / Duties in Rupees Rate of Tax (Excluding GST) / Duty / Levy Amount of Taxes (Excluding GST)/ Duties in Rupees
1 SGST/UTGST Applicable taxes (Excluding GST), duties & levies prevailing as on the last date of bid submission shall be quoted
i. Supply Portion
ii. Erection Portion
iii. Civil Portion
i. Supply Portion
ii. Erection Portion
iii. Civil Portion
i. Supply Portion
ii. Erection Portion
iii. Civil Portion
6 Building and other construction workers welfare Cess for Supply, Erection and Civil Portion works
8 a. Applicable Customs Duty (*) (Bidders shall also clearly indicate the breakup of Customs duty such as BCD, Cess,etc.,)
b. If there is any existing Treaty between India and the country from where the goods required for this project are proposed to be imported, then copy of the treaty shall be uploaded.
9 Other Taxes (Excluding GST) & duties if any (Specify) **
10 Other Taxes (Excluding GST)& duties if any (Specify) **
11 Total (Sum of 1 to 10)
(*) In case of CIF portion of Supply.
** Please Specify the nature of the other Taxes (Excluding GST) along with the details in the "Rate" Column.
Place Designation
Name of the Company
Karnataka Power Transmission Corporation Limited
SCHEDULE - 2A : SCHEDULE OF DISCOUNT
SHEET FOR TECHNOCOMMERCIAL OPENING (UN - PRICED)
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
FILL ONLY IN LIGHT BLUE COLOURED CELLS. Fill as "YES" against Price columns in case Prices are indicated in the Item-Wise Bid Financial Offer
Bidder's Name & Address alongwith GSTIN no. : To,
The Chief Engineer, Electricity, SLDC, KPTCL, Anand Rao Circle, Bengaluru - 560009.
We hereby offer an unconditional discount on our quoted price in Schedule 2 (1 of2) as under. Any discounts offered anywere else in Bid shall not be considered.
Sl.No Nature of Discount Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
Percentage of discount Amount (in Rs.) (Fill in as 'YES' in case Prices are indicated in the Percentage Wise Bid Financial Offer) Remarks
I Supply Schedules a) Ex-works prices
b) Freight & Insurance
II Erection Schedules
Place Designation
Name of the Company
Karnataka Power Transmission Corporation Limited
SCHEDULE- 2 B - STATEMENT OF COMMERCIAL TERMS AND CONDITIONS
SHEET FOR TECHNOCOMMERCIAL OPENING
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
Details of payments made in the form of Credit card/Debit card/NEFT/RTGS/OTC (over the counter) as per the tender conditions should be keyed in against column no. 3 (a) . BG Amount, BG No. and date, Name and address of the bank issuing the BG, validity of the BG should be keyed in against column no. 3 (b) .
FILL ONLY IN LIGHT BLUE COLOURED CELLS.
Bidder's Name & Address alongwith GSTIN no. : To,
The Chief Engineer, Electy., SLDC, KPTCL, Anand Rao Circle, Bengaluru - 560009
STATEMENT OF COMMERCIAL TERMS AND CONDITIONS
Sl. No. Particulars Details
1 Bid proposal form Uploaded.
2 No deviation certificate Uploaded.
3. a). EMD / Bid Security Bids shall be accompanied by bid security (EMD); 1) Up to Rs.10.00Lakh The following modes of payment will be provided as a part of e-Payment services. • Credit Card/Debit Card • Net Banking • NEFT/RTGS • Over-the-Counter (OTC) • IMPS For further detail regarding mode of e-payment of EMD in e-procurement platform, contact e-procurement cell, Government of Karnataka.
b). EMD amount above Rs.10.00Lakh by Bank Guarantee/ Insurance Surety Bond (ISB)
4 Validity of the Bid.
5 Qualifying Requirements.
6 Financial capability
8 Taxes & Duties.
9 Completion Schedule
10 Defects Liability Period/Guarantee
11 Payment Terms
Place Designation
Name of the Company
Karnataka Power Transmission Corporation Limited
SCHEDULE - 3A(i): Price Breakup for-OPGW Supply Portion
SHEET FOR TECHNO COMMERCIAL OPENING (Unpriced)
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
Bidder's Name & Address alongwith GSTIN no. : To,
The Chief Engineer, Electricity, SLDC, KPTCL, Anand Rao Circle, Bengaluru - 560009.
BIDDERS SHALL FILL ONLY IN THE LIGHT BLUE COLOURED CELLS.
Sl No. Name of the Equipment/Materials Unit Quantity Indicate whether "Own manufactured Item" or "Bought Out Item"
1 OPGW CABLE: 48 fiber Dual Window Single Mode (DWSM) OPGW Kms 8100
2 48F OPGW CABLE ACCESSORIES: i. Suspension clamp for 48 fibre OPGW Nos 24300
3 II. Tension Assembly – Dead End for 48 fibre OPGW Nos 800
4 iii. Tension Assembly – Double Tension Pass Through/ Passing Tension for 48 fibre OPGW Nos 16200
5 iv. Tension Assembly – Tension Tower joint box location including all accessories for 48 fibre OPGW Nos 2425
6 v. Tension Assembly – Suspension Tower joint box location including all accessories for 48 fibre OPGW Nos 49
7 vi. Vibration Damper for 48 fibre OPGW Nos 55500
8 vii. Down Lead clamp Assembly for 48 fiber OPGW Nos 36375
9 viii. Joint Box for 48 fibre OPGW Nos 3225
10 FODP 96F : Indoor type consisting of 4 nos. of rack mounted LIU (to be housed in FODP) with 24 ports each with FCPC coupling & pigtails Nos 400
11 FIBRE OPTIC ARMOURED APPROACH CABLE: 48 Fibre (DWSM) including Installation Hardware set for 48F Approach Cable Kms 80
12 UNDERGROUND FIBRE OPTIC UNARMOURED CABLE (UG - OFC) : 48 Fibre Dual Window Mono Mode (DWMM) UG Optical Fibre Cable as per technical specification Kms 100
13 UG OFC Accessories: i. Straight Joint Kit for Optical Fibre Cable : 48F Kit 50
14 ii. Polyvinyl Lubricated Bond (PLB/HDPE) pipe OD 40 mm Kms 100
15 Buy back value of Ground Wire: Cost of released ground wire with accessories on Rs/Per ton basis under buy-Back including loading, transportation and handling charge. kgs 3466800
NOTE: 1. Any clarifications / hard copy of drawings can be obtained from the office of the Chief Engineer Electricity, SLDC, KPTCL, Anand Rao Circle, Bengaluru .
2. Spacers shall be provided wherever necessary and no extra charges is payable on account of the same.
3. Supply of equipment/materials and the Erection charges shall include loading and unloading.
4. The Bidder shall take necessary action to ensure that all the materials supplied shall be properly housed to ensure satisfactory commissioning.
5. The Bidder shall quote same rates for common materials in all the Percentage-Wise Financial Bid Offer.
6. The Prices for all the materials shall be quoted in the Percentage- wise finanacial bid.
7.Released materials/Dismantled(if any) shall be under Buy Back and transportation, loading & unloading of the same shall be under Bidder scope.
8. The Bidder shall clearly indicate whether the materials/equipments are “Own manufactured” or “Bought out item”.
It shall be noted that, the Quantity of material indicated in the Techno-commercial sheets and ‘Percentagewise Financial offer’ in KPP portal shall be the same. In case any discrepancies is noticed between Quantity of material indicated in ‘Percentage wise Financial offer’ and Techno-commercial sheets, the Quantity indicated in KPP portal shall be considered for Price evaluation.
Place Designation
Name of the Company
Karnataka Power Transmission Corporation Limited
SCHEDULE - 3A(i): Price Breakup for-IP-MPLS Supply Portion
SHEET FOR TECHNO COMMERCIAL OPENING (Unpriced)
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
Bidder's Name & Address alongwith GSTIN no. : To,
The Chief Engineer, Electricity, SLDC, KPTCL, Anand Rao Circle, Bengaluru - 560009.
BIDDERS SHALL FILL ONLY IN THE LIGHT BLUE COLOURED CELLS.
Sl No. Name of the Equipment/Materials Unit Quantity Indicate whether "Own manufactured Item" or "Bought Out Item"
1 IP-MPLS along with accessorie: i. Supply of IP-MPLS Router for Core Ring. 800 Gbps Full Duplex or higher Chassis based modular router with redundant controller card and redundant -48V DC/-60V DC power feeds. Minimum 3 x 100GE QSFP28 interfaces equipped with 3xQSFP28 LR4 pluggable optics, those should be distributed across 3 interface line-cards. 18 nos. of 1/10GE interfaces distributed across minimum two (2) interface line-cards and equipped with following pluggables on day-1 a. 4 nos 10G SFP+ 80KM(ZR), b. 8 nos 10G SFP+ 40KM(ER), c. 4 nos 10G SFP+ 100M(SR), d. 2 nos 1G SFP 10KM(LX) No. 8
2 ii. Supply of IP-MPLS Router for Main Ring 300 Gbps Full duplex or Higher Chassis based modular router with redundant controller card and redundant -48V DC/-60V DC power feeds. Minimum 10x 1/10GE interfaces distributed across minimum two (2) interface line-cards and 20x 1GE interfaces distributed across minimum two (2) interface line-cards and equipped with following pluggables on day-1 a. 2 nos 10G SFP+ 80KM(ZR), b. 6 nos 10G SFP+ 40KM(ER), c. 2 nos 10G SFP+ 10KM(LR), d. 6 nos G SFP 10KM(LX) e. 12 nos 1G SFP RJ45 No. 400
3 Supply of Layer-3 Managed Switch for Core Locations, 48xGE RJ45 + 4x10G ports with 2x10G SR optics with redundant DC power supply No. 16
4 DWDM Equipment, for each direction with 100G MUXPONDER & 100G Client Interface No. 20
5 ILA Equipment with Amplifiers with OSC at ILA locations No. 30
6 Regen device for core ring No. 2
7 VPN Access solution for Remote Access No. 2
8 8 command Channel standalone Digital teleprotection with Ethernet interfaces No. 640
9 Protection relay I/O multiplexer No. 640
10 NMS Software with high availability (1+1) Set 1
11 NMS HW server with High availability No 6
12 NMS Client/Workstations at 6 ALDC Locations (Tumkur, Mysuru, Hassan, Gulbarga, Bagalkot & Bangalore) Set 6
13 Local Craft Terminal (Laptop) with Latest Licensed OS with antivirus and required NMS client tools No 8
14 NMS for Optical System (1+1) High Availability (Software) Set 1
15 NMS HW server with High availability for Optical system No 2
16 EMS for DTPC (HW+Software) No 1
17 VOIP Exchange with all accessories, Lifetime License for (3000) users in redundancy hardware along with 16 Port managed Switch industrial grade No. 2
18 VoiP Phone SIP Enabled No. 1020
19 GPS clock including all hardware and accessories with High Availability (1+1) Set 8
20 48V DC Power Supply (DCPS) system based on SMPS (for 15A rating) alongwith battery backup (MF VRLA Type-200 AH) No 402
21 Supply & Installation 2 TR 5 star split AC suitable for operation of A/C supply single phase 50Hz,230 V No. 400
22 Equipment Cabinet for IP-MPLS/DTPC equipment’s No. 402
23 Pota Cabinets No. 400
24 Power cables, patch cords & Accessories for 400 No of S/s's Lumpsum 1
25 IP-MPLS Testing equipment's: i. Network analysers/Protocol Analysers No. 2
26 ii. Ethernet testers (Link performance & trouble shooting No. 2
27 iii. BER (bit error rate) testers No. 2
28 iv. IP/MPLS traffic generators & monitors No. 1
29 v. Diagnostic tools (Latency, Jitter, Packet Loss No. 2
NOTE: 1. Any clarifications / hard copy of drawings can be obtained from the office of the Chief Engineer Electricity, SLDC, KPTCL, Anand Rao Circle, Bengaluru .
2. Spacers shall be provided wherever necessary and no extra charges is payable on account of the same.
3. Supply of equipment/materials and the Erection charges shall include loading and unloading.
4. The Bidder shall take necessary action to ensure that all the materials supplied shall be properly housed to ensure satisfactory commissioning.
5. The Bidder shall quote same rates for common materials in all the Percentage-Wise Financial Bid Offer.
6. The Prices for all the materials shall be quoted in the Percentage- wise finanacial bid.
7.Released materials/Dismantled(if any) shall be under Buy Back and transportation, loading & unloading of the same shall be under Bidder scope.
8. The Bidder shall clearly indicate whether the materials/equipments are “Own manufactured” or “Bought out item”.
It shall be noted that, the Quantity of material indicated in the Techno-commercial sheets and ‘Percentagewise Financial offer’ in KPP portal shall be the same. In case any discrepancies is noticed between Quantity of material indicated in ‘Percentage wise Financial offer’ and Techno-commercial sheets, the Quantity indicated in KPP portal shall be considered for Price evaluation.
Place Designation
Name of the Company
KARNATAKA POWER TRANSMISSION CORPORATION LIMITED
SCHEDULE - 3B(i) :- Price Breakup for- OPGW Erection Portion
SHEET FOR TECHNO COMMERCIAL OPENING (Unpriced)
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
Bidder's Name & Address alongwith GSTIN no. : To,
The Chief Engineer, Electricity, SLDC, KPTCL, Anand Rao Circle, Bengaluru - 560009.
BIDDERS SHALL FILL ONLY IN THE LIGHT BLUE COLOURED CELLS.
Sl No. Name of the Equipment/Materials Unit Quantity
1 48 fiber Dual Window Single Mode (DWSM) OPGW Supply & Installation (Live line Installation 400kV & 110/66 kV) (110/66kV Line= 6210kms, 400kV Line- 1080kms) Kms 7290
2 48 fiber Dual Window Single Mode (DWSM) OPGW Supply & Installation (Off Line Installation 400kV & 110/66 kV) (110/66kV Line= 690kms, 400kV Line- 120kms) Kms 810 2
3 FODP 96F : Indoor type consisting of 4 nos. of rack mounted LIU (to be housed in FODP) with 24 ports each with FCPC coupling & pigtails Nos 400 4
4 48 Fibre (DWSM) including Installation Hardware set for 48F Approach Cable Kms 80 2
5 48 Fibre Dual Window Mono Mode (DWMM) UG Optical Fibre Cable as per technical specification Kms 100 2
6 Straight Joint Kit for Optical Fibre Cable : 48F Kit 50 6
7 Polyvinyl Lubricated Bond (PLB/HDPE) pipe OD 40 mm Kms 100 6
8 Releasing of ground conductor with accessories (Live line Installation 400kV & 110/66 kV) (110/66kV Line= 6210kms, 400kV Line- 1080kms) Kms 7290 6
9 Releasing of ground conductor with accessories (Off Line Installation 400kV & 110/66 kV) (110/66kV Line= 690kms, 400kV Line- 120kms) Kms 810 2
1.Any clarifications / hard copy of drawings can be obtained from the office of the Chief Engineer Electricity, SLDC, KPTCL, Anand Rao Circle, Bengaluru
2.The Erection charges shall include transportation to site, loading and unloading.
3.Released materials/Dismantled(if any) shall be under Buy Back and transportation, loading & unloading of the same shall be under Bidder scope.
4.In accordance with Circular No. KPTCL/B19/345/84-85 dated 23.02.2024, the Contract Agency has to submit all the required survey data in GIS mapping format before submission of the final bills in the event of award and in case of additions/modifications/re-routing of existing Transmission lines, the modified survey details in GIS mapping format shall be submitted by the Contract Agency to the respective Chief Engineers/Executive Engineers of Transmission Zones, SLDC as and when the works are executed.
Place Designation
Name of the Company
KARNATAKA POWER TRANSMISSION CORPORATION LIMITED
SCHEDULE - 3B(i) :- Price Breakup for- IP-MPLS Erection Portion
SHEET FOR TECHNO COMMERCIAL OPENING (Unpriced)
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
Bidder's Name & Address alongwith GSTIN no. : To,
The Chief Engineer, Electricity, SLDC, KPTCL, Anand Rao Circle, Bengaluru - 560009.
BIDDERS SHALL FILL ONLY IN THE LIGHT BLUE COLOURED CELLS.
Sl No. Name of the Equipment/Materials Unit Quantity
1 IP-MPLS along with accessorie: i. Supply of IP-MPLS Router for Core Ring. 800 Gbps Full Duplex or higher Chassis based modular router with redundant controller card and redundant -48V DC/-60V DC power feeds. Minimum 3 x 100GE QSFP28 interfaces equipped with 3xQSFP28 LR4 pluggable optics, those should be distributed across 3 interface line-cards. 18 nos. of 1/10GE interfaces distributed across minimum two (2) interface line-cards and equipped with following pluggables on day-1 a. 4 nos 10G SFP+ 80KM(ZR), b. 8 nos 10G SFP+ 40KM(ER), c. 4 nos 10G SFP+ 100M(SR), d. 2 nos 1G SFP 10KM(LX) No. 8
2 ii. Supply of IP-MPLS Router for Main Ring 300 Gbps Full duplex or Higher Chassis based modular router with redundant controller card and redundant -48V DC/-60V DC power feeds. Minimum 10x 1/10GE interfaces distributed across minimum two (2) interface line-cards and 20x 1GE interfaces distributed across minimum two (2) interface line-cards and equipped with following pluggables on day-1 a. 2 nos 10G SFP+ 80KM(ZR), b. 6 nos 10G SFP+ 40KM(ER), c. 2 nos 10G SFP+ 10KM(LR), d. 6 nos G SFP 10KM(LX) e. 12 nos 1G SFP RJ45 No. 400
3 High level network design No 1
4 Supply, installation and commisioning of Layer-3 Managed Switch for Core Locations, 48xGE RJ45 + 4x10G ports with 2x10G SR optics with redundant DC power supply No. 16
5 DWDM Equipment, for each direction with 100G MUXPONDER & 100G Client Interface No. 20
6 ILA Equipment with Amplifiers with OSC at ILA locations No. 30
7 Regen device for core ring No. 2
8 VPN Access solution for Remote Access No. 2 2
9 8 command Channel standalone Digital teleprotection with Ethernet interfaces No. 640
10 Protection relay I/O multiplexer No. 640
11 NMS Software with high availability (1+1) Set 1
12 NMS HW server with High availability No 6
13 NMS Client/Workstations at 6 ALDC Locations (Tumkur, Mysuru, Hassan, Gulbarga, Bagalkot & Bangalore) Set 6
14 Local Craft Terminal (Laptop) with Latest Licensed OS with antivirus and required NMS client tools No 8
15 NMS for Optical System (1+1) High Availability (Software) Set 1
16 NMS HW server with High availability for Optical system No 2
17 EMS for DTPC (HW+Software) No 1
18 VOIP Exchange with all accessories, Lifetime License for (3000) users in redundancy hardware along with 16 Port managed Switch industrial grade No. 2
19 VoiP Phone SIP Enabled No. 1020
20 GPS clock including all hardware and accessories with High Availability (1+1) Set 8
21 48V DC Power Supply (DCPS) system based on SMPS (for 15A rating) alongwith battery backup (MF VRLA Type-200 AH) No 402
22 Equipment Cabinet for IP-MPLS/DTPC equipment’s No. 402
23 Pota Cabinets No. 400
24 MACsec license for all the routers for secured traffic flow without much impact on BW No 410
25 CAMC: i. Support and AMC for IP MPLS from 2nd to 6th year L/s 1
26 ii. Support and AMC for optics from 2nd to 6th year L/s 1
27 iii. Support and AMC for DTPC from 2nd to 6th year L/s 1
28 iv. Support and AMC for GPS, VOIP from 2nd to 6th year L/s 1
29 v. Cyber security VPT for 6 years (DCDR & 400 location +6 ALDC) L/s 1
30 TRAINING: i. IP MPLS training for 60 Engineers for 5 days training (12 Engineers/Batch) (price to be quoted for candidate) No 60
31 ii. NMS training for 60 Engineers for 5 days training (12 Engineers/Batch) (price to be quoted for candidate) No 60
32 iii. Optics training for 30 Engineers for 5 days training (10 Engineers/Batch) (price to be quoted for candidate) No 30
33 iv. DTPC training for 30 Engineers for 5 days training (10 Engineers/Batch) (price to be quoted for candidate) No 30
1.Any clarifications / hard copy of drawings can be obtained from the office of the Chief Engineer Electricity, SLDC, KPTCL, Anand Rao Circle, Bengaluru
2.The Erection charges shall include transportation to site, loading and unloading.
3.Released materials/Dismantled(if any) shall be under Buy Back and transportation, loading & unloading of the same shall be under Bidder scope.
4.In accordance with Circular No. KPTCL/B19/345/84-85 dated 23.02.2024, the Contract Agency has to submit all the required survey data in GIS mapping format before submission of the final bills in the event of award and in case of additions/modifications/re-routing of existing Transmission lines, the modified survey details in GIS mapping format shall be submitted by the Contract Agency to the respective Chief Engineers/Executive Engineers of Transmission Zones, SLDC as and when the works are executed.
Place Designation
Name of the Company
Karnataka Power Transmission Corporation Limited
SCHEDULE - 4 Price Break up for Supply of MANDATORY SPARES
SHEET FOR TECHNO COMMERCIAL OPENING (Unpriced)
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
Bidder's Name & Address alongwith GSTIN no. : To,
The Chief Engineer, Electy., SLDC, KPTCL, Indhana Bhavan, Bengaluru - 560009.
BIDDERS SHALL FILL ONLY IN THE LIGHT BLUE COLOURED CELLS.
Sl No. Name of the Equipment/Materials Unit Quantity Indicate whether "Own manufactured Item" or "Bought Out Item" Indicate country of Origin
1 48 fiber Dual Window Single Mode (DWSM) OPGW Kms 405
2 Suspension clamp for 48 fibre OPGW Nos 1215
3 Tension Assembly – Dead End for 48 fibre OPGW Kms 40
4 Tension Assembly – Double Tension Pass Through/ Passing Tension for 48 fibre OPGW Nos 810
5 Tension Assembly – Tension Tower joint box location including all accessories for 48 fibre OPGW Nos 122
6 Tension Assembly – Suspension Tower joint box location including all accessories for 48 fibre OPGW Nos 3
7 Vibration Damper for 48 fibre OPGW Nos 2775
8 Down Lead clamp Assembly for 48 fiber OPGW Nos 1819
9 Joint Box for 48 fibre OPGW Nos 162
10 Line Interface Unit for Optical Fibre Cable : 24F (Supply- SR-2023 Pg No: 50, Sl No: 30.8) Nos 40
11 48 Fibre (DWSM) including Installation Hardware set for 48F Approach Cable Nos 4
12 48 Fibre Dual Window Mono Mode (DWMM) UG Optical Fibre Cable as per technical specification Kms 5
13 Straight Joint Kit for Optical Fibre Cable : 48F Nos 3
14 Polyvinyl Lubricated Bond (PLB/HDPE) pipe OD 40 mm Kms 5
15 IP-MPLS Router for Core Ring. 800 Gbps Full Duplex or higher Chassis based modular router with redundant controller card and redundant -48V DC/-60V DC power feeds. Minimum 3 x 100GE QSFP28 interfaces equipped with 3xQSFP28 LR4 pluggable optics, those should be distributed across 3 interface line-cards. 18 nos. of 1/10GE interfaces distributed across minimum two (2) interface line-cards and equipped with following pluggables on day-1 a. 4 nos 10G SFP+ 80KM(ZR), b. 8 nos 10G SFP+ 40KM(ER), c. 4 nos 10G SFP+ 100M(SR), d. 2 nos 1G SFP 10KM(LX) No. 2
16 IP-MPLS Router for Main Ring 300 Gbps Full duplex or Higher Chassis based modular router with redundant controller card and redundant -48V DC/-60V DC power feeds. Minimum 10x 1/10GE interfaces distributed across minimum two (2) interface line-cards and 20x 1GE interfaces distributed across minimum two (2) interface line-cards and equipped with following pluggables on day-1 a. 2 nos 10G SFP+ 80KM(ZR), b. 8 nos 10G SFP+ 40KM(ER), c. 6 nos G SFP 10KM(LX) d. 12 nos 1G SFP RJ45 No. 10
17 Layer-3 Managed Switch for Core Locations, 48xGE RJ45 + 4x10G ports with 2x10G SR optics with redundant DC power supply No. 2
18 DWDM and ILA locations mandatory spares No. 2
19 VoiP Phone SIP Enabled No. 20
20 8 command Channel standalone Digital teleprotection with Ethernet interfaces No. 20
21 Protection relay I/O multiplexer No. 20
1. Supply of equipment/materials and the Erection charges shall include loading and unloading.
2. The Bidder shall take necessary action to ensure that all the materials supplied shall be properly housed to ensure satisfactory commissioning.
3. The Bidder shall quote same rates for common materials in all the Percentage-Wise Financial Bid Offer.
4. The Prices for all the materials shall be quoted in the Percentage wise finanacial bid.
5. The Bidder shall clearly indicate whether the materials/equipments are “Own manufactured” or “Bought out item”.
Place Designation
Name of the company
KARNATAKA POWER TRANSMISSION CORPORATION LIMITED
SCHEDULE-5 COMMERCIAL DEVIATION
SHEET FOR TECHNOCOMMERCIAL OPENING
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
Please fill Only in the Light Blue Couloured Cell.
Please key in the SlNo., Section , Clause , Description as given in bid sheets and finally your Statement of Deviation/Variations.
This Sheet would be opened at the Techno-Commercial Opening. Please refer Vendor Manual attached for further details.
For any further assistance for submitting your bids please call up KPTCL Office.
We agree to provide all original Documents in support of the information provided for verification upon request. (Key in as YES in the space provided)
We understand that the electonic bid submitted by us is a valid offer in accordance with IT Act. (Key in as YES in the space provided)
We are fully aware of the electronic bid formalities and abide by the same. (Key in as YES in the space provided)
If you are not deviating from any of the clauses mentioned please key in as 'NO DEVIATION' in the space provided.
Bidder's Name & Address alongwith GSTIN no. :
TO, THE CHIEF ENGINEER (ELECTRICTICTY), SLDC, KPTCL, Anand Rao Circle, Bengaluru -560009
I/we have read each of the Clauses mentioned in INVITATION FOR TENDERS , INSTRUCTION TO TENDERERS , CONDITIONS OF CONTRACT, SPECIAL CONDITIONS OF CONTRACT and COMMERCIAL TERMS AND CONDITIONS and all the sections of Bid documents.
The following are the commercial Deviations and Variations from and exceptions to the Specifications and documents for
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
These deviations and variations are exhaustive. Except these deviations, the entire work shall be performed as per your specifications and documents.
Sl. NO. SECTION CLAUSE NO. DESC. AS PER SPECIFICATION STATEMENT OF DEVIATIONS/VARIATIONS
Note : Deviations specified elsewhere in the specification will not be considered.
Place Designation
Name of the company
KARNATAKA POWER TRANSMISSION CORPORATION LIMITED
SCHEDULE-6 : TECHNICAL DEVIATION
SHEET FOR TECHNO-COMMERCIAL OPENING
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
Please key in the SlNo., Section , Clause , Description as given in Bid sheets and finally your Statement of Deviation/Variations.
This Sheet would be opened at the Techno-Commercial Opening.
For any further assistance for submitting your bids please call up KPTCL office. Please fill only in the blue coloured cells.
We agree to provide all original Documents in support of the information provided for verification upon request. (Key in as YES in the space provided)
We understand that the electonic bid submitted by us is a valid offer in accordance with IT Act. (Key in as YES in the space provided)
We are fully aware of the electronic bid formalities and abide by the same. (Key in as YES in the space provided)
If you are not deviating from any of the clauses mentioned please key in as 'NO DEVIATION' in the space provided.
Bidder's Name & Address alongwith GSTIN no. : TO,
THE CHIEF ENGINEER (ELECTRICTICTY), SLDC, KPTCL, Anand Rao Circle, Bengaluru , -560009
The following are the Technical Deviations and Variations from and exceptions to the Specifications and documents for
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
These deviations and variations are exhaustive. Except these deiviations and variations, the entire work shall be performed as per your specification and documents.
Sl. NO. SECTION CLAUSE NO. DESC. AS PER SPECIFICATION STATEMENT OF DEVIATIONS/VARIATIONS
Note : Deviations specified elsewhere in the specification will not be considered.
Place Designation
Name of the company
KARNATAKA POWER TRANSMISSION CORPORATION LIMITED
SCHEDULE 7(List of special tools and tackles )
SHEET FOR TECHNOCOMMERCIAL OPENING
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
Bidder's Name & Address alongwith GSTIN no. : TO,
THE CHIEF ENGINEER (ELECTRICTICTY), SLDC, KPTCL, Anand Rao Circle, Bengaluru -560009
List of special tools and tackles the price of which is included in bid price.
Sl. No. For equipment Description of item Unit Quantity
Place Designation
Name of the Company
KARNATAKA POWER TRANSMISSION CORPORATION LIMITED
SCHEDULE 8 - Additional Information
SHEET FOR TECHNOCOMMERCIAL OPENING
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
NOTE: 1 ) SHALL BE FURNISHED WITHOUT PRICES
Bidder's Name & Address alongwith GSTIN no. : To,
The Chief Engineer, Electy., SLDC, KPTCL, Anand Rao Circle, Bengaluru - 560009
We have enclosed(uploaded) with our proposal the following additional information.
Sl. No. Brief Description of information Ref. and Page No.
Date Printed Name
Place Designation
KARNATAKA POWER TRANSMISSION CORPORATION LIMITED
SCHEDULE - 9 (1 of 6) : QUALIFYING REQUIREMENTS
SHEET FOR TECHNOCOMMERCIAL OPENING
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
Please fill Only in the Light Blue Couloured Cell.
BIDDER'S NAME AND ADDRESS: THE CHIEF ENGINEER (ELECTRICTICTY), SLDC, KPTCL, Anand Rao Circle, Bengaluru - 560 009
a) * We have submitted bid as individual Bidder. (Key in Individual Bidder )
b) * We have submitted bid in Consortium with the following Bidders. (Key in Consortium ) VOID
Name of Consortium Partner Scope / Participation of each Consortium / Joint Venture Partner
(* Fill-up whichever is applicable)
1.0 GENERAL INFORMATION
All Bidder bidding for this package are requested to complete the information in the following form.
Sl.No. Particulars For individual Bidder In case of Consortium :
Lead Bidder Consortium partner
1 Name of the Firm VOID VOID
2 Address of Head Office / Registered Office GST no. VOID VOID
3 Telephone VOID VOID
4 Fax VOID VOID
5 Name of Contact person with Designation VOID VOID
6 Place of Incorporation/Registration VOID VOID
7 Year of Incorporation/Registration VOID VOID
8 Constitution or legal status of Tenderer [Upload copy] VOID VOID
9 Place of Registration [Upload copy] VOID VOID
10 Principal place of business VOID VOID
2.0 We are furnishing the following details/documents in support of Qualifying requirement for above mentioned project
Sl.No. Particulars For individual Bidder In case of Consortium :
Lead Bidder Consortium partner
(a) Written power of attorney of the signatory on the bid to commit the bidder.
1 Uploaded / Not
(b) Certificate of Registration of the Company. Please mention the date of incorporation of the company
1 Uploaded / Not
(c ) Valid Super Grade Electrical Contractor’s License issued by the Government of Karnataka as on the date of techno commercial Bid opening. Please mention the date of expiry of the License certificate issued by GOK/ Undertaking to this effect. In case Successful Bidder does not possess a valid Super Grade License from the GoK then Successful Bidders need to obtain license before issue Letter of Award. Self-declaration shall be submitted.
1 Uploaded / Not
(d) Self declaration regarding Litigation w.r.t KPTCL contracts over the last five years (refer IFT)
1 Uploaded / Not
(e) Self declaration for ‘not being disqualified regarding non-performance in any of the Government utilities in the past five years’. (refer IFB)
1 Uploaded / Not
(f) Self declaration regarding 'Eligibility clauses in respect of restrictions on procurement from a bidder of a country which shares a land border with India as per Annexure-XIV
1 Uploaded / Not
(g) Self declaration regarding RESTRICTIONS ON SOURCING OF EQUIPMENTS/MATERIALS BY THE BIDDER FROM A VENDOR OF A COUNTRY WHICH SHARES A LAND BORDER WITH INDIA as per Annexure -XV
1 Uploaded / Not
Section 3 : 1.3 Work performed of similar nature in the last Ten years of both Lead Bidder & Consortium partner (in case of Consortium) as per Clause No: 3.2 (b) (i) & (ii) of ITT
Project Name Name & Address of the Employer Description of Work Fibre Details Length of the OPGW installed Contract Number Value of contract Rs. Lakh Date of issue of work order Specified period of completion Actual date of commissioning Remarks explaining reasons for delay in commisioning of work
Name of Consortium Partner VOID
Note : 1 . The documentary proof of fulfilling the qualifying requirements shall be uploaded along with the bid. The bidder shall upload the P.O,LOI/LOA, DWA, Work done, Performance Certificates issued by the end users not below the rank of Executive/ Divisional Engineer along with the bid.
2. The qualifying experience of the Bidder and Consortium Partner(in case of Consortium) who is having qualifying experience shall be furnished in the above performa and Documentary Proof in support of above shall be uploaded in the form of certificates issued by authorized officers of concerned organisations.
3. IF this sheet is insufficient for furnishing the qualifying experience of the Bidder then similar sheets shall be seperately uploaded.
4. In case of work executed under a contract that had been awarded on a joint venture, the experience of individual joint venture partner shall be considered limited to the scope of that partner under the said contract. The copy of the agreement executed with awarding agency shall be uploaded as proof of the same
Place Designation
Name of the Company
KARNATAKA POWER TRANSMISSION CORPORATION LIMITED
SCHEDULE - 9 (2 of 6) : QUALIFYING REQUIREMENTS
SHEET FOR TECHNOCOMMERCIAL OPENING
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
BIDDER'S NAME AND ADDRESS: TO,
THE CHIEF ENGINEER (ELECTRICTICTY), SLDC, KPTCL, Anand Rao Circle, Bengaluru - 560 009
Section 3 : 1.5 Information on works for which Tenders have been submitted and works which are yet to be completed as on the date of this Tender of a Bidder
(A) Existing commitments and on-going works:
Description of work Place & State Contract No & Date Name and Address of Employer Value of Contract (Rs. Lakh) Stipulated period of of Completion Value of works remaining to be completed ( Rs.Lakhs) (Attach Certificates from Engineers –in- Charge) Anticipated date of commissioning
Ex-Works GST Total (Ex-works + GST)
Name of the Lead Bidder
Name of the Consortium Partner VOID
Note:Attach Certificates from Engineers –in- Charge
B)Works for which Tenders already submitted
Description of work Place & State Name and Address of Employer Estimated value of works (Rs. Lakh) Stipulated period of Completion Date when decision is expected Remarks if any
Ex-Works GST Total (Ex-works + GST)
Name of the Lead Bidder
Name of the Consortium Partner VOID
i) The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent. OR The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be verified and certified by Chartered Accountant /Cost Auditor. However, the Bidder has to upload the PO/Work Award copies for existing commitments and on-going works
ii) A self-declaration is to be uploaded by the Lead Bidder & Consortium partner (in case of Consortium) stating that "the information with regard to assessed available tender capacity (Works on Hand) furnished are correct". iii) Bidders shall furnish Certificate from Chartered Accountants for split details of Ex-works values and GST of Contract values of the works in the prescribed format as at Clause No. 1.5 of Section-3: Qualification Information.
Place Designation
Name of the Company
KARNATAKA POWER TRANSMISSION CORPORATION LIMITED
SCHEDULE - 9 (3 of 6) : QUALIFYING REQUIREMENTS
SHEET FOR TECHNOCOMMERCIAL OPENING
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
BIDDER'S NAME AND ADDRESS: TO,
THE CHIEF ENGINEER (ELECTRICTICTY), SLDC, KPTCL, Anand Rao Circle, Bengaluru - 560 009
Following is the list of major supplied Materials which are type tested and designed, manufactured by us in accordance with internationally recognised standards.
Sl. No. Item rating, type and Designation Qty Customer Date of Order Date of Supply Date of Commissioning Ref. of Cusomer's certificate of successful operation enclosed Ref. of layout & Customer's certificae for successful commission
Note: Documentary Proof in support of above shall be uploaded in the form of certificates issued by authorized officers of concerned organisations. .
Place Designation
Name of the Company
KARNATAKA POWER TRANSMISSION CORPORATION LIMITED
SCHEDULE - 9 (4 of 6) : QUALIFYING REQUIREMENTS
SHEET FOR TECHNOCOMMERCIAL OPENING
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
BIDDER'S NAME AND ADDRESS: To
The Chief Engineer, Electricity, SLDC, KPTCL, AR Circle Bangalore - 560 009
Section 3 : 1.7 Reports on the financial standing of the tenderer (Lead bidder & Consortium partner (in case of Consortium)), such as profit and loss statements and auditor’s reports in the preceeding last five years ; Audited Financial statements i.e Balance sheets, P&L statements, Turnover certificates duly certified by chartered Accountant as documentary evidence shall be uploaded.
SLNo. Particulars Year Lead Bidder Consortium Member
Mention Year Turnover excluding GST (in Rs.) GST Amount (in case GST is included in Turnover) (in Rs.) Turnover including GST (in Rs.) Mention Year Turnover excluding GST (in Rs.) GST Amount (in case GST is included in Turnover) (in Rs.) Turnover including GST (in Rs.)
Names of the constituent Firm VOID
1 Annual turn over for the last Five years Year(1) 2020-21 2020-21 VOID
2 Net Worth for the last Five years Year(1) 2020-21 2020-21
3 Liquid Assets / Credit availability or access to evidence of assets
4 Whether Audited Balance sheets and Profit & Loss statement are enclosed for the last Five Years ? (yes/No)
5 Whether Bankers certificate enclosed for credit facilities? (Yes/No)
Note: Bidders shall furnish Certificate from Chartered Accountants for split details of financial Turnover and GST in the prescribed format of tender document.
Place Designation
Name of the Company
Name of the Cosortium
Karnataka Power Transmission Corporation Limited
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
SCHEDULE - 9 (5 of 6) : QUALIFYING REQUIREMENTS
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
BIDDER'S NAME AND ADDRESS: TO,
THE CHIEF ENGINEER (ELECTRICTICTY), SLDC, KPTCL, Anand Rao Circle, Bangalore - 560 009
The information to be filled in by the Tenderer hereunder will be used for purposes of computing Tender capacity. This information will not be incorporated in the Contract.
Lead Bidder Consortium partner Attach Copy
1.1 Constitution or legal status of Tenderer [Upload copy]
Place of Registration [Upload copy]
Principal place of business
Section - 3: 1.2 Total value of works executed (KPTCL & Non KPTCL works)Excluding GST and payments received in the last five years (in Rs. Lakhs) of both Lead Bidder & Consortium partner (in case of Consortium).
1.2 Total value of works executed (KPTCL & NON KPTCL works) Excluding GST and payments received in the last five years (in Rs. Lakhs) of both Lead Bidder & Consortium partner (in case of Consortium). Financial Year KPTCL works Non KPTCL works
Individual Bidder In case of Consortium Individual Bidder In case of Consortium
Total value of works Excluding GST in Rs. Lakh Lead Bidder Consortium Partner Total value of works Excluding GST in Rs. Lakh Lead Bidder Consortium Partner
Total value of works Excluding GST in Rs. Lakh Total value of works Excluding GST in Rs. Lakh Total value of works Excluding GST in Rs. Lakh Total value of works Excluding GST in Rs. Lakh
Note: Attach relevant Certificate/s from Chartered Accountant.
Section 3: 1.9 Name, address, telephone number & e-mail id of the Tenderers' bankers who may provide references if contacted by the Employer:
1.9 Sl.No Name, address, telephone number & e-mail id of the Tenderers' bankers
Section 3: 1.12 Information on litigations in which the Tenderer is involved:
Other Party(ies) Employer Details of Dispute Amount involved Remarks showing Present Status
Place Designation
Name of the Company
KARNATAKA POWER TRANSMISSION CORPORATION LIMITED
SCHEDULE - 9 (6 of 6) : QUALIFYING REQUIREMENTS
SHEET FOR TECHNOCOMMERCIAL OPENING
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
BIDDER'S NAME AND ADDRESS: To
The Chief Engineer, Electricity, SLDC, KPTCL, Bangalore - 560 009
Section3 : 1.6 The following items of equipment are considered essential for successfully carrying out the works. The Tenderer should furnish all the information listed below
Sl. No. Item / equipment Requirement capacity (should match with 3.3(a) of ITT) Owned/brought out on hired or Lease basis Owned & available Age/ Condition Remarks
1 Hydraulic Crane
2 Three Sheave Arial Rollers
3 Hydraulic Compressor Jointing Machine
4 Drum lifting jacks
5 Come along clamps
7 Road Roller & Graders
8 Rolling Compactors
9 Excavators & Dozers
10 Adequate Tentioners & Pullers (in case of 400kV Transmission line works )
Note: Self-Declaration regarding the above shall be uploaded
Place Designation
Name of the Company
KARNATAKA POWER TRANSMISSION CORPORATION LIMITED
SCHEDULE-10 (1 of 3) Details of Tools and Plants available
SHEET FOR TECHNOCOMMERCIAL OPENING
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
BIDDER'S NAME AND ADDRESS: To
The Chief Engineer, Electricity, SLDC, KPTCL, Bangalore - 560 009
Following are the details of the Tools and Plants available with us.
Sl. No. Description Quantity Make Present Location / Project Remarks (if any)
Place Designation
Name of the Company
KARNATAKA POWER TRANSMISSION CORPORATION LIMITED
SCHEDULE 10-2 of 3 Details of Technical staff employed
SHEET FOR TECHNOCOMMERCIAL OPENING
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
BIDDER'S NAME AND ADDRESS: To
The Chief Engineer, Electricity, SLDC, KPTCL, Bangalore - 560 009
Section 3: 1.8 Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
Sl. No. Name of the employee Designation Branch (Degree/Diploma) Year of Passing Since when employed in erection division Past Experience
Place Designation
Name of the Company
KARNATAKA POWER TRANSMISSION CORPORATION LIMITED
SCHEDULE 10- (3 of 3)
SHEET FOR TECHNOCOMMERCIAL OPENING
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
BIDDER'S NAME AND ADDRESS: To
The Chief Engineer, Electricity, SLDC, KPTCL, Bangalore - 560 009
We propose the following deployment of manpower for the above project.
Sl. No. Category MONTHS AFTER PLACEMENT OF AWARD LETTER
1 Project manager
2 Sr. Project Manager
5 Skilled labour
6 No skilled labour
Place Designation
Name of the Company
KARNATAKA POWER TRANSMISSION CORPORATION LIMITED
SCHEDULE-11B : COMPLETION SCHEDULE FOR TRANSMISSION LINES
SHEET FOR TECHNOCOMMERCIAL OPENING
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
Bidders Name and Address: To
The Chief Engineer, Electricity, SLDC, KPTCL, Bangalore - 560009
We hereby declare that following shedules shall be followed by us for the above work. The period of various activities from the date of placement of award letter shall be as follows.
SL.NO Activity Period in months for work of OPGW Installation
Commencement Completion
1 Submission of Drawings
2 Completion of detailed engineering
3 Commencement of Manufacturing
4 Completion of Manufacturing
5 Readiness for testing
6 Readiness for Shipment
7 Receipt at Site
b OPGW Hardware accessories
d Approach Cable
f UG OFC accessories
1 Detailed Survey
2 Setting up of site office, sheds and stores etc.
3 Stringing of OPGW/UG OFC alongwith accessories
4 Testing , Commissioning and Handing over.
Place Designation
Name of the Company
KARNATAKA POWER TRANSMISSION CORPORATION LIMITED
SCHEDULE-11 (A) : COMPLETION SCHEDULE FOR STATION PORTION
SHEET FOR TECHNOCOMMERCIAL OPENING
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
Bidders Name and Address: To,
The Chief Engineer, Electricity, SLDC, KPTCL, Bangalore - 560009
We hereby declare that following schedules shall be followed by us for the above work. The period of various activities from the date of placement of award letter shall be as follows
SL.NO Activity Period in Months for the work of IP-MPLS
Commencement Completion
1 Detailed engineering
2 Procurement of bought out items / raw materials
3 Manufacturing & Testing
5 Setting up of site office, Sheds & stores etc.
6 Receipt(at site) of
a)IP-MPLS along with accessories
b)Layer-3 Managed Switch
c)DWDM Equipment
d)Digital teleprotection Coupler (DTPC)
f)Exchange and IP Phones
g) Synchronization Equipment
h) IP-MPLS Testing equipment's
7 Erection of above
a)IP-MPLS along with accessories- Core Ring
b)IP-MPLS along with accessories- Main Ring
8 Completion of testing and ready for commissioning
9 Commissioning & Integration
Place Designation
Name of the Company
Karnataka Power Transmission Corporation Limited
SCHEDULE - 12 TYPE TESTS & TEST CHARGES OF EQUIPMENT/MATERIALS
SHEET FOR TECHNOCOMMERCIAL OPENING
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
BIDDERS SHALL INDICATE VARIOUS TYPE TESTS IN LIGHT BLUE COLOURED CELLS
ALL THE TYPE TESTS APPLICABLE FOR EACH OF THE EQUIPMENTS SHALL BE INCLUDED.
Bidders Name and Address To,
The Chief Engineer, Electricity, SLDC, KPTCL, Bangalore - 560009
SL.No Details of Equipments Type Test Test Charges ( in Rs )
1 Optical fibers
3 OPGW Cable fittings
4 Vibration Damper
5 Splice Enclosure (Joint Box)
6 Approach Cable
8 UG cable accessories(Joints and terminations)
11 Batter Charger
NOTE: The Type Test / Special Tests, if repeated at the insistance of owner, the applicable testing charges shall be paid by the successful Bidder upfront to the laboratory and the same shall be reimbursable by KPTCL as per actuals on submission of Bills along with proof of payment and on successful completion of all the Type Tests, specified and on approval of the same by the owner. In case equipment/material fails in the type tests during testing then the testing charges paid by the Bidder to the laboratory will not be reimbursed by KPTCL. The above Clause is applicable for all the equipments/materials, in case, the Type Test / Special Tests, are repeated at the insistance of owner(KPTCL).
Place Printed Name
Karnataka Power Transmission Corporation Limited
Schedule -13-List of Optional Spares
SHEET FOR TECHNOCOMMERCIAL OPENING
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
Bidders Name and Address
To, The Chief Engineer, Electricity, SLDC, KPTCL, Bangalore - 09.
List of optional spares required to meet the specified performance for a period of three years
Sl. No. For Equipments Details of item Unit Quantity
Place Designation
Name of the Company
Karnataka Power Transmission Corporation Limited
SCHEDULE - 14-Guaranteed Losses
SHEET FOR TECHNOCOMMERCIAL OPENING
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Bidders Name and Address To,
The Chief Engineer, Electy., SLDC, KPTCL, Indhana Bhavana, BANGALORE - 560009
Dear Sir, We Declare that the ratings and performance figures of the OPGW & IP-MPLS furnished by us under the Turnkey Package are Guaranteed. We further declare that in the event of any deficiencies in meeting the guarantees in repect of the characteristics mentioned below as established after conducting the factory test, you may at your discretion,reject or accept the equipment after assessing the liquidated damages as specified in relevant clause of Bid Document.
Sl no Equipment Guaranteed Performance
1 IP-MPLS- 100G VOID
Note:(i) Refer Technical Specifications (ii)The loss quoted shall be consistent in Schedule 14 and GTPs(DRS) of Power Transformers
Place Designation
Name of the Company
Karnataka Power Transmission Corporation Limited
LIST OF VENDORS
SHEET FOR TECHNOCOMMERCIAL OPENING
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
BIDDERS NAME AND ADDRESS To, The Chief Engineer, Electricity, SLDC, KPTCL, Bangalore - 09.
Sl. No. EQUIPMENT/ MATERIAL NAME OF THE VENDOR
VENDOR 1 VENDOR 2 VENDOR 3 VENDOR 4
2 OPGW Hardware accessories
4 Approach Cable
6 UG OFC accessories
7 IP-MPLS along with accessorie
8 Layer-3 Managed Switch
9 DWDM Equipment
10 ILA Equipment with Amplifiers
11 Regen device
13 Digital teleprotection with Ethernet interfaces
14 Protection relay I/O multiplexer
15 NMS HW server with High availability
16 NMS Workstations
17 Local Craft Terminal (Laptop)
18 NMS HW server for Optical system
19 EMS for DTPC
20 VOIP Exchange with all accessories
21 VoiP Phone SIP Enabled
23 48V DC Power Supply (DCPS)
24 2 TN 5 star split AC
25 Equipment Cabinet for IP-MPLS/DTPC equipment’s
26 Pota Cabinets
27 Network analysers/Protocol Analysers
28 Ethernet testers (Link performance & trouble shooting
29 BER (bit error rate) testers
30 IP/MPLS traffic generators & monitors
31 Diagnostic tools (Latency, Jitter, Packet Loss
Note : Any Other Materials name & its vendors are to be entered.
Place Designation
Name of the Company
Karnataka Power Transmission Corporation Limited
SHEET FOR TECHNOCOMMERCIAL OPENING (UN - PRICED)
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
Bidders Name and Address
To, The Chief Engineer, Electricity, SLDC, KPTCL, Bangalore - 09.
We Declare that the ratings and performance figures of the equipment furnished by us under the Turnkey Package are Guaranteed. We further declare that in the event of any deficiencies in meeting the guarantees in repect of the characteristics as established after conducting the performance test, you may at your discretion, reject the equipment, in which case we shall replace the same with equipment as per specification and meeting the guarantee, free of charge and within a resonable time, to be mutually agreed.
Place Designation
Name of the Company
KARNATAKA POWER TRANSMISSION CORPORATION LIMITED
SCHEDULE -17- Check List
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
BIDDERS NAME AND ADDRESS To,
The Chief Engineer, Electy., SLDC, KPTCL, Anand Rao Circle, Bengaluru - 560009
CHECK LIST FOR SUBMISSION OF SCHEDULES
REFERENCE OF FORM & SCHEDULE DETAILS OF FORM & SCHEDULE WHETHER INCLUDED IN TECHNO-COMMERCIAL SHEETS (ELECTRONIC) YES/NO WHETHER INCLUDED IN Percentage-Wise Bid Financial Offer (ELECTRONIC) YES/NO WHETHER INCLUDED IN COMMERCIAL
PROPOSAL BID PROPOSAL
Schedule - 1 PRICE COMPONENTS
Schedule 2 (1 of 2 & 2 of 2) Summary of Price Components
Schedule 2A Schedule of Discounts
Schedule 2B Statement of Commercial Terms & Conditions
Schedule 3A & 3B Price break up for supply & erection
Schedule 3C Price break up for civil works
Schedule 4 Price break up for mandatory spares and maintenance & Testing Equipments.
Schedule 5 Commercial deviations
Schedule 6 Technical deviations
Schedule 7 List of special Tools & Tackles
Schedule 8 Additional information.
Schedule 9 Qualification Information [Technical & Financial]
Schedule 10 Details of Tools and plants and man power deployment
Schedule 11 A & 11B Schedule for activities & Commissioning.
Schedule 12 Type Test Charges
Schedule 13 List of optional spares and cost.
Schedule 14 Guaranteed loss of transformer.
Schedule 15 List of vendors.
Schedule 16 Guaranteed Declaration
Schedule 17 Check list
DRS 1-4 Relevant Technical details for Materials / Equipments
To be Uploaded Contract Quality Assurance Programme
To be Uploaded Type Test Certificates
To be Uploaded & furnished Bid Security/EMD
To be Uploaded Written Power of Attorney
To be Uploaded Letter of Undertaking
To be Uploaded No Deviation Certificate
To be Uploaded Any Other (Please Specify)
To be Uploaded Any Other (Please Specify)
To be Uploaded Any Other (Please Specify)
Place Designation
Name of the Company
Karnataka Power Transmission Corporation Limited
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
TECHNICAL DATA SHEET
GUARANTEED TECHNICAL PARTICULARS OF OPGW CABLE.
SLNO PARAMETER UNIT PARTICULARS
1 Fibre Manufacturer Dual Window Single-Mode:
2 No. of Fibres Dual Window Single-Mode: each
4 Buffer Tube Diameter: mm
5 Buffer Tube material
6 No. of Buffer Tubes: each
7 No. of Fibers per Tube: each
8 Identification/numbering of individual tubes:
9 No. of empty tubes (If any): each
10 Filling material:
11 Filling material compliant with technical specifications? Yes/No
12 Strength member(s):
13 Binding yarn/ tape:
14 Describe Central Core Design:
15 Aluminum Clad steel wire
Diameter: mm each
16 Aluminum alloy wires
Diameter: mm each
17 Aluminum tube inner diameter: mm
18 Aluminum tube outside diameter: mm
19 Cable Diameter:(nominal ± deviation) mm
20 Cable cross-section area (Nominal): mm2
21 Cable cross-section area (Effective): mm2
22 Fully Compliant with IEEE 1138: Yes/No
23 Max. breaking load/ Ultimate Tensile Strength (UTS): kN
24 Fibre strain margin: %
25 Zero fibre strain up to load kN
26 Weight: kg/km
27 Crush strength: kg/mm
28 Equivalent Modulus of elasticity: KN/mm2
29 Minimum Bending Radius without microbending: mm
30 Maximum Bending Radius: Short Term: Long Term (Continuous): mm
31 Tensile proof test (Screening) level: KN/mm2
32 Maximum permissible tensile stress: KN/mm2
33 Permissible CTS. tensile stress: KN/mm2
34 Maximum sag at maximum temperature and design span with no wind: mm
35 Everyday tension at 32ºC, no wind: % of UTS
36 Maximum tension at Every day condition with full wind pressure Kg
Thermal Properties of Cable:
38 Coefficient of linear expansion: per °C
39 Coefficient of expansion
Cladding: per °C
40 Nominal operating temperature range: °C
41 SC current transient peak temperature: °C
42 Maximum allowable temperature for lightning strike: °C
CABLE SPOOL and DRUM:
43 Available length per spool
46 Size of drum: m
47 Weight of empty drum: kg
48 Weight of drum with cable: spooled kg
49 Will drum length scheduling be practiced to match transmission line span lengths? Yes/No
50 Describe Drum materials:
51 Describe cable end capping and protection against abrasion etc.:
52 Splice Loss: dB
Maximum: Average: dB
53 Operating Temperature Range: °C
54 Rated Isoceraunic No.
55 Expected Cable Life: Years
56 Installation rate per team: km/day
57 No. of persons per team: no.
58 Max. possible span for specified operating conditions: M
59 Midspan sag at 0°C with no wind loading: Mm
60 Midspan sag at max temp. with no wind loading: Mm
61 Midspan sag at max temp. and wind loading Mm
62 Cable swing angles:
63 Describe Installation method(s):
OPTICAL PARAMETERS:
64 Fiber manufacturer(s)/Type:
65 Fiber production method:
66 Attenuation Coefficient
@ 1310 nm: dB/km
@ 1550 nm: dB/km
67 Attenuation Variation with
68 Wavelength (±25 nm): dB/km
69 Attenuation at water peak: dB/km
70 Point discontinuity
71 Temperature dependence (induced attenuation): dB
72 Nominal Mode Field Diameter
73 Mode Field Diameter Deviation
74 Mode field non-circularity: %
75 Chromatic Dispersion Coefficient
@ 1550 nm: Ps/nm.km
76 Zero dispersion wavelength: nm
77 Zero dispersion Slope: ps/nm2.km
78 Cutoff wavelength: nm
79 Refractive Index:
80 Refractive Index profile:
81 Cladding Design:
82 Numerical aperture:
PHYSICAL and MECHANICAL PROPERTIES:
83 Bend Performance:
(37.5 mm radius, 100 turns) @1310 nm dB
(30 mm radius, 100 turn) @1550 nm (16mm radius, 1 turn) @ 1550nm dB
84 Core Diameter (nominal± deviation): μm
85 Core non-circularity: %
86 Cladding Diameter μm
(nominal ± deviation):
87 Core- Clad concentricity Error: μm
88 Cladding noncircularity: %
89 Fibre cut-off wavelength μm
90 Protective Coating type & material
Primary: Secondary:
91 Protective Coating Diameter μm
(nominal ± deviation):
92 Protective Coating removal method:
93 Coating Concentricity μm
94 Polarisation mode dispersion coefficient ps/km^1/ 2
95 Proof test level kpsi
96 Colour coding scheme compliant with EIA/TIA 598 or IEC 60304 or Bellore GR-20. Yes/No
97 Colouring material compliant with technical specs? Yes/No
NOTE : Other Techincal paramters should be as per technical specifications
Place Designation
Name of the Company
Karnataka Power Transmission Corporation Limited
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
TECHNICAL DATA SHEET
GUARANTEED TECHNICAL PARTICULARS OF OPGW HARDWARE
SLNO PARAMETER UNIT PARTICULARS
I. Suspension Clamp Assembly:
Name of Manufacturer:
Address of the Manufacturer #:
1 Minimum vertical Strength kN
2 Maximum Slip Strength kN
3 Minimum Slip Strength kN
4 Length (nominal) mm
5 Weight (nominal) kg
6 Total Drop (maximum) including shackles mm
7 Tightening torque (nominal) Nm
8 Details of Armour Rod Set
a) No. of rods per clamp
b) Direction of Lay
c) Overall length mm
d) Diameter of each Rod mm
(i) Diameter of each rod ±%
(ii) Length of each rod ±%
f) Material of manufacture
g) UTS of each Rod kN
9 Details of Protection Splice Set (Reinforcing Rods)
i) No. of rods per clamp
j) Direction of Lay
k) Overall length mm
l) Diameter of each Rod mm
(i) Diameter of each rod ±%
(ii) Length of each ±%
n) Material of manufacture
o) UTS of each Rod kN
II. Dead End Clamp Assembly:
Name of Manufacturer:
Address of the Manufacturer #:
1 Minimum Slip Load kN
2 Length (nominal)
a) Reinforcing Rods mm
3 Weight (nominal)
a) Reinforcing Rods kg
4 Breaking strength (minimum) kN
a) Reinforcing Rods mm
III. Vibration Damper
Name of Manufacturer:
Address of the Manufacturer #:
1 Total Weight Kg
2 Weight of each Damper Kg
3 Material of Damper Weight
4 Clamp Material
5 Clamp bolt tightening torque Nm
6 Clamp bolt material
7 Messenger Cable Material
8 No. of Strands in Messenger Cable
9 Breaking Strength of Messenger Cable kN
10 Resonance Frequencies
a) First Frequency Hz
b) Second Frequency Hz
c) Third Frequency Hz
d) Forth Frequency Hz
11 Minimum Slip Strength of Damper Clamp
a) Before Fatigue Test kN
b) After fatigue Test kN
IV. Down Lead Clamp /Fastening Clamp
Name of Manufacturer:
Address of the Manufacturer #:
2 Suitable for OPGW (range): mm
3 Tightening torques Nm
4 Vertical load kN
5 Filler details:
(b) diameter: mm
6 Tower attachment arrangement
V. Splice Enclosures(Joint Box) for Overhead FO cable
Name of Manufacturer:
Address of the Manufacturer #:
1 Dimensions H * W * D: cm
3 Colour and Finish:
4 Cable Glanding & Fixing:
5 Construction materials & Gauge:
6 Locking arrangements:
7 Installation Clearances: Front Access:
Rear Access: Top * Bottom * Sides: cm
8 IP Protection Class
9 Total number of optical couplings: ea
10 Provision of pass through splicing: Yes/No
11 Whether filled with suitable encapsulant Yes/No
Optical Fibre Cable Accommodations
13 Cable Glanding:
14 Maximum number of cables that can be accommodated:
15 Diameter(s) of cables that can be accommodated:
16 Describe Cable entries
Cable Termination Splice Accomodations:
17 Details of Splice Trays:
Colour & Finish:
Method of mounting:
18 Maximum number of splice trays: ea
19 Number of splices per tray: ea
20 Provision of Splice organisors:
21 Do splice trays require a separate enclosure? If so: Yes/No
Dimensions H * W * D: cm
Colour and Finish:
Method(s) of Mounting:
Construction materials & Gauge:
Locking arrangements:
22 Installation Clearances
Top * Bottom * Sides:
Excess length of fibre service loops m
V1. JOINT BOX for Approach cable
Name of Manufacturer:
Address of the Manufacturer #:
1 Dimensions cm
3 Colour and Finish:
4 Cable Glanding:
5 Construction materials & Gauge:
7 Total number of optical splicing: ea
8 Suitable for use in Manholes and direct buried: Y/N
9 Degree of Protection IP
10 Describe sealing method
Optical Fibre Cable Accommodations
11 Cable Glanding:
12 Maximum number of cables that can be accommodated: each
13 Describe Cable entries:
Cable Termination Splice Accommodations:
14 Maximum number of splice trays: each
15 Number of splices per tray: each
VII. Fibre Optic Distribution Panels (FODPs)
Name of Manufacturer:
Address of the Manufacturer #:
1 Dimensions H * W * D: cm
3 Colour and Finish:
4 Cable Glanding & Fixing:
5 Construction materials & Gauge:
6 Locking arrangements:
7 Installation Clearances: Front Access:
Rear Access: Top * Bottom * Sides: cm
8 IP Protection Class
9 Total number of optical couplings: ea
10 Provision of pass through splicing: Yes/No
11 Whether filled with suitable encapsulant Yes/No
12 Method(s) for mounting
Optical Fibre Cable Accommodations
13 Cable Glanding:
14 Maximum number of cables that can be accommodated: each
15 Diameter(s) of cables that can be accommodated:
16 Describe Cable entries:
Cable Termination Splice Accomodations:
17 Details of Splice Trays:
Colour & Finish:
Method of mounting:
18 Maximum number of splice trays: ea
19 Number of splices per tray: ea
20 Provision of Splice organisors:
21 Do splice trays require a separate enclosure? If so: Yes/No
Dimensions H * W * D: cm
Colour and Finish:
Method(s) of Mounting:
Construction materials & Gauge:
Locking arrangements: m
22 Installation Clearances Front Access:
Rear Access: Top * Bottom * Sides:
Excess length of fibre service loops
VIII. APPROACH CABLE
Name of Manufacturer:
Address of the Manufacturer #:
1 Fibre Manufacturer
Dual Window Single-Mode:
2 No. of Fibres
Dual Window Single-Mode: each
4 Buffer Tube Diameter: mm
5 Buffer Tube material
6 No. of Buffer Tubes: each
7 No. of Fibers per Tube: each
8 Identification/numbering of individual tubes:
9 No. of empty tubes (If any): each
10 Filling material:
11 Filling material compliant with technical specifications? Yes/No
12 Strength member(s):
13 Binding yarn/ tape:
14 Describe Central Core Design:
15 Outside Jacket coating (if any)
16 Jacket thickness mm
17 Jacket non-circularity %
18 Cable Diameter: (nominal deviation) mm
19 Cable cross-section area: mm2
20 Rip-cord provided? Yes/No
21 Fully Compliant with IEC 60974-3: Yes/No
Mechanical Properties of Cable
22 Max. breaking load/ Ultimate Tensile Strength (UTS): kN
23 Fibre strain margin: %
24 Zero fibre strain up to load kN
25 Weight: kg/km
26 Crush strength: kg/mm
27 Equivalent Modulus of elasticity: KN/mm2
28 Minimum Bending Radius without microbending: mm
29 Maximum Bending Radius: mm
Short Term: Long Term (Continuous):
30 Tensile proof test (Screening) level: KN/mm2
31 Maximum permissible tensile stress: KN/mm2
32 Permissible CTS. tensile stress: KN/mm2
33 Every day tensile stress N
34 Torsion twist/m
Thermal Properties of Cable
35 Coefficient of linear expansion: per °C
36 Coefficient of expansion
Cladding: per °C
37 Nominal operating temperature range: °C
CABLE SPOOL and DRUM
38 Available length per spool m
Maximum: Nominal:
39 Size of drum: m
40 Weight of empty drum: kg
41 Weight of drum with cable: spooled kg
42 Will drum length scheduling be practiced to match transmission line span lengths? Yes/No
43 Describe Drum materials:
44 Describe cable end capping and protection against abrasion etc.:
45 Splice Loss:
Maximum: Average: dB
46 Operating Temperature Range: °C
47 Expected Cable Life: Years
48 Describe Installation method(s) and the cable duct parameters for installation of approach cable:
IX. PLB HDPE PIPE
2 Pipe diameter(outside) mm
nominal tolerance
3 Wall thickness mm
nominal tolerance
4 Standard Length mm
nominal tolerance
6 Two concentric layers type/ Homogeneous type Construction
7 Thickness of permanent lubricant mm
8 Construction material of outer layer
9 Construction material of inner layer
11 Inner layer colour
12 Base HDPE Resin: (a)Density at 270 C Kg/m3
(b)Melt flow rate at 1900 C & 5 kg load g/10 minutes
13 Service life span year
14 Maximum outside diameter of FO cable that can be installed by blowing technique mm
15 Suitable for underground cable installation by- Y/N
16 Suitable for laying in trenches by- Y/N
(a)Directly burying (b)Through G.I./RCC hume pipe
17 Suitable for laying through trenchless horizontal direction drilling Y/N
18 Tensile strength N/mm2
19 Elongation at break %
20 Internal coefficient of friction
21 Bend radius Mm
22 Draw rope details:
(a) Construction
(b) Diameter mm
(d) Breaking Load Strength kg
23 Describe anti rodent measures of PLB HDPE pipes
Pipe accessories
24 Coupler type
25 Coupler material
26 Coupler strength
27 End cap material
NOTE : Other Techincal paramters should be as per technical specifications
Place Designation
Name of the Company
Karnataka Power Transmission Corporation Limited
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
TECHNICAL DATA SHEET
GUARANTEED TECHNICAL PARTICULARS OF UG OFC & Hardware Fittings
SLNO PARAMETER UNIT PARTICULARS
NOTE : Other Techincal paramters should be as per technical specifications
Place Designation
Name of the Company
Karnataka Power Transmission Corporation Limited
Tender Enquiry No: KPTCL/CEE-SLDC/SEE-SCADA/OPGW-Phase-II/2026-27/01 Dtd: 10-04-2026
Establishment of statewide Optical Ground Wire (OPGW) and Internet Protocol Multi-Protocol Label Switching (IP‑MPLS) Communication Network for Karnataka Power Transmission Corporation Limited
TECHNICAL DATA SHEET
GUARANTEED TECHNICAL PARTICULARS OF IP-MPLS & connected Communication Equipments
SLNO PARAMETER UNIT PARTICULARS
NOTE : Other Techincal paramters should be as per technical specifications
Place Designation
Name of the Company
DRS-Core Router
TECHNICAL DATA SHEET
GUARANTEED TECHNICAL PARTICULARS OF Core Routers
SLNO PARAMETER UNIT PARTICULARS
1 Modular Chassis based Routers Yes/No
2 Controller Redundancy Yes/No
3 Universal slots Yes/No
4 Throughput Capacity 800Gbps Full Duplex Gbps
5 Per slot Capacity 150Gbps Full Duplex Gbps
6 Redundant DC Power feeds Yes/No
7 Fan Redundancy Yes/No
8 Operating temperature: 0°C to +65°C guaranteed Yes/No
9 Humidity: 5% to 95% Non-Condensing Yes/No
10 Router/Router Series/Router OS/Router family should be EAL3+ certified from Day-1 Yes/No
11 Router should be compliant to EMC/EMI standard Yes/No
12 Support multi-rate interfaces: 1/10GE, 10/25GE, and 40/100GE, Coherent/grey Yes/No
13 Should support min 4x100GE + 40x10GE/1GE simultaneously Yes/No
14 Port requirement on Day-1, Minimum 3 x 100GE QSFP28 LR4 distributed across 3 interface line-cards. Minimum 18 x 1/10GE distributed across 2 line-cards and equipped with 4 No’s 10 G SFP + 80 KM (ZR), 8 No’s 10 G SFP + 40 KM (ER), 4 No’s 10 G SFP + SR, 2 No’s 1G SFP 10 KM LX Nos
15 Support line-rate 10GE, 100GE interfaces with both grey and coloured pluggable Yes/No
16 All the required Licences are included on Day-1 Yes/No
17 The router should support Bidirectional Forwarding Detection (BFD: Single hop/ Multiple hop) Yes/No
18 Shall support link aggregation using LACP as per IEEE 802.3ad, and MC-LAG. Yes/No
19 Should support IP MPLS, Segment Routing, SR- TI-LFA, SR-TE,SRLG, ITU-T G.8032v2, BGP-LS, BGP-LU (RFC 3107) Protection, BGP, IS-IS, OSPFv2 and OSPFv3, VRRP, IPv6 Routing, and BGP Prefix Independent Convergence Yes/No
20 should support synchronization using IEEE 1588v2 and Sync-E Profiles: G.8265.1, G.8275.1, G.8275.2 . Clock Roles: MC, BC, SC.ITU-T SyncE G.8262.1. Yes/No
21 Shall support Strict Priority Queuing or Low Latency Queuing to support real time application like Teleprotection, SCADA, Voice and Video with minimum delay and jitter Yes/No
22 Should support hierarchical QoS for voice and video Yes/No
23 Multiple privilege level authentications for console and telnet access through Local database or through an external AAA Server Yes/No
24 The router should have capability of minimum 250K IPv4, 150K IPv6 routes (FIB) Nos
25 The router should support minimum 250K MAC address. Nos
26 Router should support 6K MPLS PWE3. Nos
27 Router should support 6K VPLS. Nos
28 Router should support 4K MPLS Layer-3 VPNs Nos
29 The router should support 12k labels and 10 label stack depth. Yes/No
30 Should support minimum 16 ECMP (equal cost multipath). Yes/No
31 Configuration Roll Back to recover the mis-configured router to last good configuration Yes/No
32 Multicast: IGMPv1/v2/v3, PIM-SM, PIM-SSM, MSDP Yes/No
33 MPLS VPN, mVPN, CSC, Inter-AS VPN, RSVP, VPLS, VPWS, EoMPLS, EVPN Yes/No
34 OAM: IEEE 802.1ag, Y.1731, Y.1564, IEEE 802.3ah Yes/No
NOTE : Other Techincal paramters should be as per technical specifications
Place Designation
Name of the Company
DRS-2 Main Router
TECHNICAL DATA SHEET
GUARANTEED TECHNICAL PARTICULARS OF Main Routers
SLNO PARAMETER UNIT PARTICULARS
1 Modular Chassis based Routers Yes/No
2 Controller Redundancy Yes/No
3 Universal slots Yes/No
4 Throughput Capacity 300Gbps Full Duplex Gbps
5 Per slot Capacity 150Gbps Full Duplex Gbps
6 Redundant DC Power feeds Yes/No
7 Fan Redundancy Yes/No
8 Operating temperature: 0°C to +65°C guaranteed Yes/No
9 Humidity: 5% to 95% Non-Condensing Yes/No
10 Router/Router Series/Router OS/Router family should be EAL3+ certified from Day-1 Yes/No
11 Router should be compliant to EMC/EMI standard IEC 61850-3 Yes/No
12 Support multi-rate interfaces: 1/10GE, 10/25GE, and 40/100GE Yes/No
13 Should support min 4x100G + 20x10G + 10x1G simultaneously Yes/No
14 Port requirement on Day-1, Minimum 10x 1/10GE distributed across min 2 interface line-cards 20x 1GE distributed across min 2 interface line-cards 2 No’s 10 G SFP + 80 KM(ZR), 6 No’s 10 G SFP + 40 KM (ER) 2 No’s 10 G SFP + 10 KM (LR) 6 No’s 1 G SFP 10 KM) LX) 12 No’s 1 G SFP RJ45 Nos
15 Support line-rate 10GE, 100GE interfaces with both grey and coloured pluggable Yes/No
16 All the required Licences are included on Day-1 Yes/No
17 The router should support Bidirectional Forwarding Detection (BFD), and micro-BFD Yes/No
18 Shall support link aggregation using LACP as per IEEE 802.3ad, and MC-LAG. Yes/No
19 Should support IP MPLS, Segment Routing, SR- TI-LFA, SRLG Protection, BGP, IS-IS, OSPFv2 and OSPFv3, VRRP, IPv6 Routing, and BGP Prefix Independent Convergence Yes/No
20 should support synchronization using IEEE 1588v2 and Sync-E . Yes/No
21 Shall support Strict Priority Queuing or Low Latency Queuing to support real time application like Teleprotection, SCADA, Voice and Video with minimum delay and jitter Yes/No
22 Should support hierarchical QoS for voice and video Yes/No
23 Multiple privilege level authentications for console and telnet access through Local database or through an external AAA Server Yes/No
24 The router should have capability of minimum 128K IPv4, 32K IPv6 routes (FIB) Nos
25 The router should support minimum 64K MAC address. Nos
26 Router should support 3K MPLS PWE3. Nos
27 Router should support 2K VPLS. Nos
28 Router should support 1200 MPLS Layer-3 VPNs Nos
29 The router should support 4k labels and 10 label stack depth. Yes/No
30 Should support minimum 16 ECMP (equal cost multipath). Yes/No
31 Configuration Roll Back to recover the mis-configured router to last good configuration Yes/No
32 Multicast: IGMPv1/v2/v3, PIM-SM, PIM-SSM, MSDP Yes/No
33 MPLS VPN, mVPN, CSC, Inter-AS VPN, RSVP, VPLS, VPWS, EoMPLS, EVPN Yes/No
34 OAM: IEEE 802.1ag, Y.1731, Y.1564, IEEE 802.3ah Yes/No
NOTE : Other Techincal paramters should be as per technical specifications
Place Designation
Name of the Company
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Annexure 4 KPTCL OPGW Network Map.pdf
Others - Annexure-4 • 1.41 MB
Annexure 2 Main Links_Substations.pdf
Others - Annexure-2 • 0.06 MB
Volume-2 OPGW UGOFC Technical Specifications.pdf
Tender Document • 1.20 MB
Annexure 3- Core links and Substations.xlsx
Others - Annexure-3 • 0.05 MB
Volume-1.pdf
Tender Document • 1.83 MB
Annexure 1 Guidelines for OPGW_UG OFC.pdf
Others - Annexure-1 • 1.80 MB
Techno Commercial Sheet.xlsx
Techno-Commercial Worksheet • 0.18 MB
Voulme-2 IP MPLS Technical Specifications.pdf
Tender Document • 2.29 MB
Annexure 5 Roles_responsibilities.pdf
Others - Annexure-5 • 0.14 MB
NIT_Phase-II.pdf
Others - Notification • 0.38 MB
Corrigendum-II.pdf
pdf • 0.24 MB
Addendum-Corrigendum.pdf
pdf • 1.36 MB
DRS-DTPC.xlsx
xlsx • 0.02 MB
Annexure-B_400kV Line Connectivty Details.pdf
pdf • 0.11 MB
Annexure-A_Technical Specification and Type Test for UG-OFC.pdf
pdf • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .