Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.9 CrAccepted-AOC | ₹1.9 Cr | 1 | Accepted-AOC Q |
| 2 | 2₹2.2 Cr+₹25.7 L (13.3%)Rejected-AOC | ₹2.2 Cr+₹25.7 L (13.3%) | 2 | Rejected-AOC N Q |
Tender Value
₹2.1 Cr
EMD Value
₹4.3 L
Closing Date
14 Nov 2023, 2:00 pmClosed
Chief Engineer, PWD(Roads), Assam
O/o the Chief Engineer, PWD(Roads), Assam
Re-const of 1) Sati Joymoti Rd B/L, Athgaon near Marwari Maternity Hospital 2) Chabipul Bilpar Rehabari Bilpar connecting Rd 3) Rehabari H.D.F.C. Bank adjacent B/L from Sitla Mandir to Bilpar 4) Rehabari Amtol Goli, B/L-1 under MMNPPNA-2023-24
2023_PWD_33242_36
CE/CW/20/2023-24-Nagariya(GMC)
Open Tender
Civil Works – Roads
Item Rate
180 days
Guwahati
Please refer Tender documents.
4 documents required · 4 mandatory
₹4,300
₹4.3 L
Yes
12 Mar 2024
25 Oct 2023
14 Nov 2023
25 Oct 2023
14 Nov 2023
25 Oct 2023
25 Oct 2023 - 14 Nov 2023
Amount
Excavation in Ordinary Soil (i) Excavation in Cutting in Soil by manual means with lead upto 50 m Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3 (Manual method should be adopted where machines can not be deployed due to site condition)
Dismantling of Cement Concrete Pavements as per Technical Specification Clause 202. Dismantling of cement concrete pavements by mechanical means using pneumatic tools breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials separately
Removal of Unsuitable Soil with Disposal upto 1000 m : Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11
Granular Sub-base with Well Graded Material (Table 400.1) By Mix in Place Method : Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. For Grading II Material
WBM Grading 3 Using stone screening Type-B 11.2 mm for Gr.III Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. A) By Manual Means
Interlocking Pavement Block : Providing and laying Interlocking Concrete Block Pavement with M40 grade of concrete blocks having thickness 80mm as per technical specification clause 1504 complete including carriage. Excluding Edge block/ Edge restraints
Retro reflectorised Traffic sign : Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) ii) 60 cm Equilateral Triangle
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved materials. (I) Ordinary Soil (A) Manual Means (Depth upto 3 m) (Without de-watering)
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (A)With crushed Stone (II) PCC Grade M15
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification steel shuttering formwork. (E )RCC Grade M20 (a) Height upto 5m
Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, .complete as per drawing and technical specifications.
Back filling behind abutment, wing wall and return wall complete as per drawing and technical specification. (B) Sandy materials
Tapash Paul
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .