Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.7 LAccepted-AOC | L1 | Accepted-AOC Accepted
Being L1 | |
| 2 | L2₹22.4 L+₹1.4 L (6.48%)Rejected-AOC HOUSE NO 95 STREET NO 08 JAWAHAR COLONY NEAR LAXMI DAIRY FARIDABAD SECTOR 22 HARYANA 121005 | FARIDABAD | HARYANA | 121005 | L2 | Rejected-AOC Rejected
Being L2 | |
| 3 | Rejected-Technical SKALZANGLING AIR PORT ROAD LEH LADAKH 194101 | LEH | LEH | LADAKH | 194101 | - | Rejected-Technical not enlisted in b(ii) category |
Tender Value
₹23.5 L
EMD Value
₹46,920
Closing Date
10 Nov 2022, 6:00 pmClosed
CWE (AF) LEH
HQ CWE (AF) LEH PIN - 194101
REPAIR/MAINT OF HT CABLE, HT BUS BARS, TRANSFORMERS, VOLTAGE STABILIZER AND OTHER E/M CONNECTED ITEMS AT DOMESTIC AREA IN 21 WING AF STN LEH
2022_MES_555266_2
81152/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
HQ CWE (AF) Leh
Please Refer Tender Documents
7 documents required · 7 mandatory
₹500
GE (AF) LEH
₹46,920
Yes
25 Nov 2022
19 Oct 2022
12 Nov 2022
19 Oct 2022
10 Nov 2022
27 Oct 2022
Amount
Excavation in trenches in hard/dense soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables and foundation of poles etc. and getting out, complete all as specified and directed.
Returning, filling in trenches (soil), including spreading, leveling and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and directed.
Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed.
Supplying and laying, factory made unreinforced precast concrete cable cover HV type-1, flat, of size 300x180x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, complete all as specified and directed.
Disconnecting 11KV electric supply from existing 2 pole structure and maintenance and servicing/ overhauling of existing indoor type, horizontal draw out type VCB, of current rating 630 Amps by disconnected HT cable termination joints, checking and cleaning all the spare parts of 11 KV VCB to avoid any chance of flashing, loose connection sparking, any burning parts and to replace all nuts,bolts and washers, if found any damaged due to flashing,short circuit,earth fault etc with new one anodiesed of existing size,testing and calibration of earth fault and over load relays complete after re-connction of all dismantled cables and again testing after re-charging the VCB and testing complete with satisfactorily of GE and the necessary spares i e. as per original equipment manufactures as per site requirement complete all as specified and directed. (Make-Schneider.) SMS Nos (a) 774/3007/HV/21 (b) 774/3008/HV/21 (c) 774/3005/HV/21 (d) 774/3006/HV/21
All as per item No. 6.00 here-in-before but 11 KV VCB 400 amps complete all as specified and directed. (Make-Schneider.) SM No : (a) 774/3004/HV/21 (b) 774/3009/HV/21 (c) 774/3010/HV/21 (d) 774/3011/HV/21 (e) 774/3012/HV/21 Note for item No 06 & 07 : - (i) New spare parts shall be measured & paid seperately under relevent items as supply only. (ii) Cost of sleeves if replaced shall be demed to be included in unit rate only. (iii) Transportation requirement at site and back cost shall be included in quoted rate only.
Supply, laying, jointing, testing and commissioning of High Tension (HT), 11000Volts (earthed) grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with multi stranded aluminum conductor, cross sectional area 185 Sqmm, 3core under ground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and directed Note : Excavation and earth work, sand cushioning and precast concrete cable cover for protection of cable shall be measured and paid separately. Make : Polycab/Havells/Gloster.
All as per item No 8. above but of size 120 Sqmm,3 core
All as per above item No 8. above but of size 95 Sqmm,3 core
Supply and fix outdoor type sheet metal of 3.15mm thick termination / junction box of size 1500 x 1000 x 1000mm with angle iron frame/ support with copper bus bar of size 50 x 6mm suitable for HT cable termination and locking arrangement, the legs to be fixed on foundation with PCC 1:3:6 type C-2 (using 40mm graded aggregate) complete all as specified.
Supply, jointing & testing, straight through joint kit Heat shrinkable type complete with jointing material and accessories suitable for 11KV grade (earthed), HT, underground XLPE insulated armoured aluminium conductor, 3core 120Sqmm to 185 Sqmm size cable, in repairs complete all as specified and directed. Make : 3M/Universal/Raychem/Denson/M-seal.
All as per item No 12 here-in-above but of 3 core 50 sqmm to 95 sqmm size cable.
Material and labour for indoor end termination joint kit Heat shrinkable type complete with jointing material and accessories suitable for 11KV grade (earthed), HT, underground XLPE insulated armoured aluminium conductor, 3core 120Sqmm to 185 Sqmm size cable but in repair, complete all as specified and directed. Make : 3M/Universal/Raychem/Denson/M-seal.
Material and labour for outdoor end termination joint kit Heat shrinkable type complete with jointing material and accessories suitable for 11KV grade (earthed), HT, underground XLPE insulated armoured aluminium conductor, 3core 50 Sqmm to 95 Sqmm size cable but in repair, complete all as specified and directed. Make : 3M/Universal/Raychem/Denson/M-seal.
Material and labour for earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically (depth of pit not less than 2.25m below normal ground level), with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron strip of size 32mmx6mm thick (upto body of equipment) by means of nuts, bolts, check nuts & GI washers, connected to main switch board or main control board or test point, protected by galvanized iron pipe medium grade 40mm dia bore, and watering pipe 20mm dia bore GI medium grade with funnel & wire mesh including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, complete all as specified and directed. Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of Eqpt/Bldg. (iii) Rate shall include GI strip and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 5 Ohm. In case the test results are not found below 5Ohm, complete earthing will be redone without any extra cost to Govt.
All as per item No 16 here-in-above but connected to GI wire of 4 mm dia..
Material and labour Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron strip except GI pipe all as specified and directed.
Supply and fix in repair HT bushing complete with gasket, for transformers of capacity 250 KVA to 400 KVA all as specified and directed.
Supply and fix in repair LT bushing complete with gasket, for transformers of capacity 250 KVA to 400 KVA all as specified and directed.
Supply and replacement of Silica gel breather assembly with silica gel cristal (500 gram) for 400 KVA capacity transformer.
Supply of transformer oil superior quality having di-electric strength not less than 50 KV at 2.0mm gap, ISI marked, 200 liter sealed drum, and filling, topping up into transformers and voltage stabilizer, complete all as specified and directed. Note:- Empty durm will be remain the property of the contractor.
Supply and fix in repair HT copper winding coils of required size with super enameled superior quality copper wire of suitable size and specification, complete with insulation, varnishing, vaccum impregnation and baking of coil assembly etc, complete all as specified and directed.
Supply and fix in repair LT copper winding coils of required size with super enameled superior quality copper wire of suitable size and specification, complete with insulation, varnishing, vaccum impregnation and baking of coil assembly etc, complete all as specified and directed.
Dismantling and removing of voltage stabilizer of capacity upto 10 KVA single phase dry type from electric circuit, strip opening of the same for repair work and replacement of worn out parts including wiring & interconnections , removal of damaged parts & re-assembling of the voltage stabilizer after carrying out the repair work and re-fixing in position, making connections, including testing and commissioning, complete all as specified and directed. Note : Supply of new spare parts shall be measured and paid for separately as under:-
Supply only electronic relays of suitable capacity.
Supply only of control circuit complete including soldering the same with existing circuit
Supply only indicator LED type (R/Y/B).
Supply only auto and manual switch of suitable capacity.
Dismantling and removing of voltage stabilizer of capacity upto 50 KVA three phase from electric circuit, strip opening of the same for repair work and replacement of worn out parts including wiring & interconnections , removal of damaged parts and re-assembling of the voltage stabilizer after carrying out the repair work and re-fixing in position, making connections, including testing and commissioning, complete all as specified and directed. Note : Supply of new spare parts shall be measured and paid for separately as under:-
Supply only servo motor of capacity 3 Kg.
Supply only control circuit complete including soldering the same with existing circuit.
Supply only auto transformer(Dimmer) of input voltage single phase 90 to 270 volts and output voltatge single phase 230 volts for power 50 KVA complete all as specified and directed by Engineer-in-charge.
Dismantling and removing of voltage stabilizer of capacity 51 to 100 KVA from electric circuit, strip opening of the same for repair work and replacement of worn out parts including wiring & interconnections , removal of damaged parts and re-assembling of the voltage stabilizer after carrying out the repair work and re-fixing in position, making connections, including testing and commissioning, complete all as specified and directed. Note : Supply of new spare parts shall be measured and paid for separately as under:-
Supply only servo motor of capacity 5 Kg.
Supply only control circuit complete including soldering the same with existing circuit.
Supply only auto transformer(Dimmer) of input voltage single phase 90 to 270 volts and output voltatge single phase 230 volts for power 51 to 100 KVA complete all as specified and directed by Engineer-in-charge
Dismantling and removing of voltage stabilizer of capacity upto 101 KVA to 320 KVA from electric circuit, strip opening of the same for repair work and replacement of worn out parts including wiring & interconnections , removal of damaged parts and re-assembling of the voltage stabilizer after carrying out the repair work and re-fixing in position, making connections, including testing and commissioning, complete all as specified and directed. Note : Supply of new spare parts shall be measured and paid for separately as under:-
Supply only servo motor of capacity 10 Kg.
Supply only control circuit complete including soldering the same with existing circuit.
Supply only auto transformer(Dimmer) of input voltage single phase 90 to 270 volts and output voltatge single phase 230 volts for power 100 to 320 KVA complete all as specified and directed by Engineer-in-charge.
Supply only voltmeter 0 to 250 volts Analog type (suitable for Voltage stablizer capacity 10 KVA to 320 KVA)
Supply only ammeter 0 to 100 amp of complete set Analog type(suitable for Voltage stablizer capacity 10 KVA to 320 KVA)
Supply only limit switch (suitable for Voltage stablizer capacity 10 KVA to 150 KVA)
Supply only indicators LED Type suitable for Voltage stablizer capacity 10 KVA to 320 KVA
Supply only auto and manual switch of suitable capacity.
Supply only connector block (suitable for Voltage stablizer capacity 10 KVA to 320 KVA)
Dismantling and removing of UPS of capacity upto 10 KVA single phase dry type from electric circuit, strip opening of the same for repair work and replacement of worn out parts including wiring & interconnections , removal of damaged parts and re-assembling of the UPS after carrying out the repair work and re-fixing in position, making connections, including testing and commissioning, complete all as specified and directed.
Supply only inverter control circuit complete including soldering the same with existing circuit.
Supply only charging control circuit complete including soldering the same with existing circuit.
Supply only transformer of capacity upto 200 VA (step down/step up) for control circuit.
Supply only transformer of capacity upto 500 VA (step down/step up) for UPS.
Supply only connector block of suitable capacity.
Supply only auto and manual switch of suitable capacity.
Supply and fixing of chain link fencing made out of 4mm dia galvanized iron wire of diamond shape mesh of 75mmx75mm size, fixed to any type of standard rails, straining bolts etc., with and including provision of binding wire (annealed) not less than 0.9mm dia, complete all as specified and directed.
Supply and fixing Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed.
Supply and fixing mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n. exc 5 cm long and 16 to 20 mm dia of neck. and one hexagonal or square nut, n. exc 5 cm long and 16 to 20 mm dia of neck.
Material and labour for preparation of new steel surfaces of any description over 10cm in width or girth, not otherwise described and apply two coats of synthetic enamel paint over a coat of red oxide zinc chrome complete all as specified and directed by Engr-in-Charge.
M&L for MS plain black sheet of thickness 1.6mm for panel canopy cut to size holes punched, including round headed screws, clout nails or rivets and fixed to steel framing with welded seams, including bending or turning up complete all as specified and as directed.
Material and labour for 40mm coarse aggregates in sub stations and proper levelling complete all as specified and directed by Engineer in charge
Supply only 11 KV HT VCB operating mechanism with motor operated spring charged system assembly including coil assembly with 24 Volts DC auxiliary supply system works satisfactorily and testing complete all as specified and directed
Supply only manual charging of closing spring and emergency hand trip assembly and testing complete all as specified and directed.
Supply only HT CTs( Primary and secondary) as per existing suitable ratio 30-150/5+5A, whether wound ring or bar type with complete settings with relay, short circuit instrument, earthfault instrument ,metering equipment with transformer ratio adjustment with burden,acuuracy etc complete all as specified and directed.
Supply only Mild steel 11 KV tripping coil for HT breaker all as specified and directed by Engineer-in-charge.
Supply only HT bus bar with insulators as suitable for existing rating current in three phase with proper moisture proof with nuts, bolts and washer and suitable lugs with proper crimping and adequate clearance between the bus bar and earth and any fabrication, as required, as per site conditions by the contractor at its own cost, complete all as specified and directed.
Overhauling of primary injection by atificial load through CT's & secondry injection of over current earth fault relays/release on each multipule setting readjustment and testing comlete all as specified and directed
Supply only hooter electrically operated,240 Volts ,50 Hz and testing complete all as specified and directed
Supply only relays for AC failure alarm,supervision alarm, annunciation scheme connected with the circuite breaker and testing facilities complete all as specified and directed
Supply only release combination mechanism,closing solenoid coil, tripping coil, secondary tripping coil, auxilary switch contacts, Castell key interlocking and including setting of over load coil,no volt coil, tripping coil, off and on mechanism ,contact resistance measures and providing any unserviceable spare parts where functional requirments and testing complete all as specified and directed.
Supply only PT's both ( Primary and secondary) and apply multi grease for mechnical parts, inspecting HT bushing male and female and apply dry graphite conductive sealant for contacts,replaced damaged insulators and testing, and assembling, allienemts of components and testing complete all as specified and directed.
Supply only HT contact assembly such as auxillary contactor(2 No+2NC) with burnt coil and all accessories and checking of electrical wiring system,and testing complete all as specified and directed.
Supply only phase indication 'RYB' neon lamps with all connected accessories and including 9w LED lamp at inside of the VCB with electrical wiring system and testing complete all as specified and directed.
Supply only tripping shaft assembly with coil and including springs,strips and connected accessories for functional requirement with electrical wiring system and testing complete all as specified and directed.
Supply only closing shaft assembly with coil and including springs, close strips and connected accessories for functional requirement with electrical wiring system and testing complete all as specified and directed.
Supply only vaccum interrupter bottles assembly and connected accessories for functional requirement and checking of electrical wiring system and testing complete all as specified and directed.
Supply only numerical relay 2 o/c + E/F and connected accessories for functional requirement checking of electrical wiring system and testing complete all as specified and directed.
Supply only IDMT,IDMTL relays and calibration through primary and secondary testing and connected accessories for functional requirement checking of electrical wiring system and testing complete all as specified and directed.
Supply only interlocking mechanisim assembly for functional requirements and testing complete all as specified and directed.
Supply only OFF and ON mechanisim assembly for functioning requirements and testing complete all as specified and directed.
Supply only 11 KV VCB supervision scheme where circuit breaker 'open' where indication " Green" ,Breaker 'Close' indication "Red", wheather breaker 'auto trip' indication "White" and breaker 'Spring charged' indication is "Blue" and testing complete all as specified and directed.
Supply and fix in repair HT Stud (Brass) complete with nuts & bolts with gasket for transformers of capacity 250 KVA to 400 KVA all as specified and directed.
Supply and fix in repair LT Stud (Brass) complete with nuts & bolts with gasket for transformers of capacity 250 KVA to 400 KVA all as specified and directed. Note : Sch of credit for Rs. 30,225.00 (Rs. Thirty thousand two hundred and twenty five only) to be deducted on acceptance of bid.
RND ENGINEERS & CONTRACTORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .