Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance MIRZAPUR MUMTAZ NAGAR AYODHYA AYODHYA UTTAR PRADESH 224001 | AYODHYA | UTTAR PRADESH | 224001 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Rejected-Technical 0 DHANA TEJA BARARI DHANA TEJA MATHURA MATHURA UTTAR PRADESH 281005 | MATHURA | UTTAR PRADESH | 281005 | Rejected-Technical date of work completion is not mentioned |
| 5 | Rejected-Technical 00 OPP RASHMI HOSPITAL RAYA ROAD LAXMI NAGAR MATHURA UTTAR PRADESH 281204 | MATHURA | UTTAR PRADESH | 281204 | Rejected-Technical decleration paper is not correct |
Tender Value
₹78.2 L
EMD Value
₹79,000
Closing Date
23 May 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EWC AYODHYA
OFFICE OF THE SUPERINTENDING ENGINEER ELECTRICITY WORKS CIRCLE, AYODHYA
20/SE/EWC/AYO/2023-24
2023_MVVNL_795079_4
20/SE/EWC/AYO/2023-24
Open Tender
Electrical Works
Item Wise
90 days
AMETHI
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
SUPERINTENDING ENGINEER, ELECTRICITY WORKS CIRCLE
₹79,000
6 Sept 2023
18 May 2023
23 May 2023
18 May 2023
23 May 2023
18 May 2023
Amount
Safe Loading, Carriage and then safe unloading of the following material from Store Centres Under the jurisdiction of EEESD Ayodhaya to dump site proper stacking.
PCC pole 9 Mtr.
STP 11 Mtr.
Cost of ACSR Dog Conductor (5.5x3+5%) (Sag charges, cutting and wastage)
Cost of 33 KV 3x300 sq mm XLPE Cable
33 KV Outdoor jointing Kit for 3x300 sq mm XLPE Cable
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection of Single Pole for 33 KV Line on 9.0 Mtr PCC Pole with fitting of necessary clamp & other acessories like 1 no Channel Cross Arm, as per norms. (All materials shall be provided by the Contractor expect pole and insulator)
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection for Sectional Double pole for 33 KV Line on 9.0 Mtr PCC Pole with fitting of necessary clamp & other acessories like 1 No Top channel of 125x65x6 mm size 3200 mm, 6 No. Disc. Fitting , Bracing angle 1 set., 33 KV Polymer Disc insulator 6 No. and 3 No. Composit Polymer Pin insulator as per norms. (All materials shall be provided by the Contractor expect pole and insulator)
Erection of single stud pole support on PCC Pole 9.0 Mtr long with fixing of necessary clamps and other accessories required for erection. (All materials shall be provided by the Contractor expect pole)
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection of Single Pole for 33 KV Line on 11 Mtr ST Pole with fitting of necessary clamp & other acessories like 1 No. Channel Cross Arm, as per norms. (All materials shall be provided by the Contractor expect pole and insulator.)
Fabrication Erection of D/P for 33 KV Cable Exposure on STP 11 Mtr long with the provision of bus bar on D/p for Cabele connection. Including fixing of 09 Nos. GI pin with pin insulator 1 No. dropper angle 2.5 mtr. long & other material as per Cost data book norms & site Condition. on 11 Mtr. Long ST pole with fixing of necessary clamps & other accessories like 1 No. Top Channel 125x65 mm-3.20 Mtr. Long 125*65 mm. 1500 mm. long channel 2 No., 01 Set bracing angle 65x65x6 4.3 mtr. including clamps nuts & bolts , fixing of danger board , number plate, barbed wire, E- Bracket/Top cleat etc.(All materials shall be provided by the Contractor expect pole and Insulator.)
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection for Sectioal Double pole for 33 KV Line on 11 Mtr ST Pole with fitting of necessary clamp & other acessories like 1 No. Top channel of 125x65x6 mm size 3200 mm, Disc Fitting 6 No., Bracing angle 1set. ,33 KV Polymer Disc insulator 6 No. and 3 No. Polymer Pin insulator as per norms..(All materials shall be provided by the Contractor expect pole And Insulator.)
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection of Four pole for 33 KV Line on 11 Mtr ST Pole with fitting of necessary clamp & other acessories like 4 No. Top channel of 125x65x6 mm size 3200 mm, Disc Fitting 6 No. Bracing angle 4 set, Polymer Disc insulator 33 KV 06 No. 70 KN B&S ., Composite Pin insulator 09 No. as per norms. (All materials shall be provided by the Contractor expect pole and insulator)
Shifting, loading, carriage & Erection of Four Pole structure on 09 mtr. PCC Pole including all works of evocation of pit, pole erection, back filling of earth , proper ramming & fitting of all accessories For Single Circuit (M.S. angle iron bracing with clamps, top channel with clamps, disc insulator 70 KN B & S type, 6 No. disc fitting B & S type, Compsit Polymer pin insulator 09 No., P.G. Clamp, 'E' bracket, danger board with clamp, pole including all work as per norms etc. complete.(All materials shall be provided by the Contractor expect pole and Insuator.)
Fabrication & Erection of exposure Dead End Double pole on 11 Mtr. STP support with fitting of supply and mounting of necessary clamps and other accessories like 01 No. top channel 125x65x6 mm size 3200 mm, Bracing Angle 1 set, 11 kv disc insulator 12 No. and 3 No. disc fitting as per RESPO Norms. (Contractor shall provide 03 No. Disc fitting ,Neccessary clamps ,Nuts & Bolts etc.)
Fabrication & Erection of Dead End Double pole on 9.00 mtr PCC support and mounting of necessary clamps and other accessories for holding clamp of D/P fixing of Top channel composite pin insulator ,Bracing angle with clamp, B & S type disc and disc fitting, Danger Board , Barbade wire etc as per cost data book. (All materials shall be provided by the Contractor expect pole and insulator)
Erection of single stud pole support on STP Pole 11 Mtr long with fixing of necessary clamps and other accessories required for erection. (All materials shall be provided by the Contractor expect pole)
Cradle Guarding of 33 KV line at road crossing, 11 KV line crossing, canal/telephone line crossing by fixing Guarding Angle 65x65x6 mm, 3500 mm at double pole and 2600 mm long at single pole by stringing and sagging of 3 No. G.I.wire with lacing and tightening with mounting. (Contractor shall provide Necessary clamps for fitting of guarding angle and 3 No. Eye Bolt 12x110 mm, G.I Wire 6 SWG along the line and 8 SWG across the line etc. All materials will be arranged by the contractor)
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection of Tri pole of 33 KV Line on 9.0 Mtr PCC Pole with fixing of necessary clamp & other acessories like 3 No Top channel of 125x65 mm size 3.2 Mtr. Long, 03 Set. Bracing Angle 65x65x6 mm 4300 Mm Long Including Clamps and Nuts Bolts , fixing of 06 Nos.33 KV polymer Disc B & S type, 05 Nos. 33 KV composite Pin Insulator , 05 Nos. E- Clamps with nuts & Bolts , 06 Nos. Disc Fitting For Dog Conductor, Fixing of Danger Board, Barbed Wire, Number Plate, 03 Nos. Stone pad 300x300x75 mm & P.G. Clamps for Dog , etc. as per Resspo norms. (Contractor will provide Danger Board, Barbed Wire , Number Plate , 05 Nos. E- Clamps with nuts & Bolts , 06 Nos. Disc fitting & 03 Nos. Stone pad 300x300x75 mm & P.G. Clamps for Dog & necessary clamps Nuts & Bolts for fixing etc. all required Materials as per Site Condition except pole and insulator)
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection of Tri pole of 33 KV Line on 11.0 Mtr ST Pole with fixing of necessary clamp & other acessories like 3 No Top channel of 125x65 mm size 3.2 Mtr. Long, 03 Set. Bracing Angle 65x65x6 mm 4300 Mm Long Including Clamps and Nuts Bolts , fixing of 06 Nos.33 KV polymer Disc B & S type, 05 Nos. 33 KV composite Pin Insulator , 05 Nos. E- Clamps with nuts & Bolts , 06 Nos. Disc Fitting For Dog Conductor, Fixing of Danger Board, Barbed Wire, Number Plate, 03 Nos. Stone pad 300x300x75 mm & P.G. Clamps for Dog , etc. as per Resspo norms. (Contractor will provide Danger Board, Barbed Wire , Number Plate , 05 Nos. E- Clamps with nuts & Bolts , 06 Nos. Disc fitting & 03 Nos. Stone pad 300x300x75 mm & P.G. Clamps for Dog & necessary clamps Nuts & Bolts for fixing etc. all required Materials as per Site Condition except pole and insulator)
Nozeling and grouting of stay at sectional pole and extra stay sets at angle locations (All the civil material and stay set, stay clamp will be arranged by the contractor except stay wire)
Stringing, sagging, binding and Jumpering of ACSR Dog conductor. 3 Phase of 33 KV Line including fixing, mounting of P.G.clamp suitable for Dog Conductor at sectional point. (Contractor shall provide necessary PG clamps etc)
Jumpering on sectional poles by Dog conductor and providing 12 no. P.G clamp for dog holding jumpers properly. ( All materials shall be provided by the contractor.)
Angle for Cross arm Support at Angle Location 65x65x6 mm 1600 mm long with clamps and nut & bolt. (All materials will be supplied by the contractor)
Cable stand Structure Fabrication & erection of 33 KV Cable Stand made of 02 No. M.S chanel 125x65x6 mm 3 Mtr. Jointed to each other by M.S Channel horizontally and also jointed to each other by means of 05 No. M.S Strip 50x6 mm of size 150 mm long each by welding at actual distance interval as per norms. And grouting in block of 300x300x700 completely providing 02 no. cable clamps also and eathing by G.I strip 50x6 mm size with the earth mat of switchyard both side of legs. And prividing 06 no. 33 KV post insulator for cable support. Painting of structure by Al. paint (All materials will be arranged by the contractor such that channel 125x65x6, M.S angle 65x65x6 clamps nut bolts and civil materials .)
Laying & Dressing of 3x300 sq. mm XLPE Cable underground Double Circuit. Laying of double circuit 3x300 sq .mm XLPE Cable in normal soil by HDD system/digging of trench 1050 mm deep, 750 mm wide including supply of required materials, as 1st class Bricks, Stone slabs and fine sand. Providing 150 mm fine sand cusion beneath, and 150 mm sand cusion above the cable. The cable shall be duly protected by Bricks, sand and providing the stone slab top of the cable . The inter axial spacing between two cables should be in between 0.25 to 0.04 M. After laying the cable refilling and ramming of the left out soil,closing the trench and leveling, stone slabs are provided top of the cable in both site conditions
Road restoration Kaccha/Pakka road as per norms.
Hoisting of 33 KV Cable on existing/erected support with provision of MS Pipe 150 mm dia 3 mtr long suitable for 3x300 sq mm cable fixing of proper support and its clamping, providing long barral lugs 6 nos and P.G. Clamps & "Y" shape jumpering properly and 02 nos. supporting angle 65X65X6, 2240 mm long and making connection including supply of jumpering cable ,mounting clamps as per RESSPO Norms. (All material will be supplied by the contractor like M.S Pipe , P.G. Clamps, Al. Lug And Supporting Angle 65X65X6, 2240 mm and jumpering cable suitable for 33 KV jumper).
High Pressure testing to which 33 KV Line & cable to be stand for duration of 5 minutes after completion of Laying, Stringing, sagging, binding and Jumpering of ACSR Dog conductor. ( Testing equipment will be arranged by the contractor)
Fabrication, Erection and grouting of route marker and marking 33 KV line by painting after grooving on the stone. (Contractor shall provide all materials)
Earthing of Pole STP/PCC by 6 SWG Wire by providing and fixing of 20 mm dia' earthing rod 2.550 Mtr. long as per norms complete in all respect and providing G.I wire by sorting the X-arm rounding the pole to the earthing rod. (Contractor shall provide all the material Like Earthing rod, 6 swg wire, Earthing clamps and nut & bolt etc.)
Grouting of following structure by digging of pit 1.5 Mtr/1.83 Mtr deep for 9.0 Mtr PCC / 11 Mtr STP respectively, placing stone pad at bottom 450x450 size foundation is provided with help of steel or wooden formers, groutung with 1:4:8 Ratio cement, sand & first class brick ballast 0.268/0.285 cu mtr for 9.0 mtr PCC Pole & 11 mtr STP, plinthing 0.3 Mtr above G/L and proper plastering.
11 Mtr ST Poles
9.0 Mtr PCC pole
Painting of poles Painting of 11 Mtr S.T. pole with one coat of red oxide, two coats of enamel paint ISI mark. (All required material will be supplied by the contractor)
Fixing of Danger board . Supply and fitting of Danger board of size 250x200x2 mm 3650 mm above ground level as per Respo norms.RESPO Drawing No-55
Fixing of Number plate . Providing and fitting of SMC Number plate of size 250x200x2 mm 3650 mm above ground level as per Respo norms. (All materials will be provided by the Contractor)
Providing and fixing of a stone pad of size 300x300x75 mm at PCC/STP Bottom of the pit.
Fixing of barbed wire on pole Supply and fixing of barbed wire on the pole above 2750 mm ground level. Barbed wire wrapped for a distance of 0.9 mtr. with a pitch of 13.mm at a height. (All materials supplied by the contractor)
Installation of Heat Shrinkable Type cable jointing kits of following types/sizes for 33 XLPE Cable. Fixing of 33 KV 3x300 sq. mm Outdoor End Terminations (jointing kit supplied by dept.)
Petrolling on feet from starting to end and removal/lopping and chopping of tree branches which are lying in route of 33 KV overhead line.
Supply materials
33 KV Polymer disc insulator B &S type 70 KN
33 KVComposite Polymer Pin insulator
M/S R.G. TRADERS
M/s S S Associates
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .