Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.9 LAdmitted-Finance | ₹16.9 L | L1 | Admitted-Finance |
| 2 | L2₹24.1 L+₹7.2 L (42.5%)Admitted-Finance | ₹24.1 L+₹7.2 L (42.5%) | L2 | Admitted-Finance |
| 3 | L3₹26.5 L+₹9.6 L (56.7%)Admitted-Finance | ₹26.5 L+₹9.6 L (56.7%) | L3 | Admitted-Finance |
| 4 | L4₹26.6 L+₹9.7 L (57.2%)Admitted-Finance | ₹26.6 L+₹9.7 L (57.2%) | L4 | Admitted-Finance |
| 5 | L5₹28.0 L+₹11.1 L (65.5%)Admitted-Finance | ₹28.0 L+₹11.1 L (65.5%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S Praduman Kumar Sharma L3 | M/S AK SINGH L2 | A K DUTTA CHOWDHURY AND CO L4 | satyabhama and co L1 | M/S DILIP GOSWAMI L5 | A M CHOUDHURY AND CO L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including
cover fillets complete all as specified and as directed. | 56 | Sqm | 385 ₹21,560 | 450 ₹25,200 | 600 ₹33,600 | 185 ₹10,360 Lowest | 420 ₹23,520 | 450 ₹25,200 |
| 2.00 | M&L for side panelling with GI (galvanised iron) box panel frame work of 24 gauge perforated to an extent of 70% and of 4" thick box panels of (8'x1') in dimension. The panels with 4" (100mm) thick box panel should have infill acoustic material density varies from 32 & 16 Kg/cum (glass wool as acoustic material). The material should have the ability to attain 50% insertion loss and attenuate incident sound energy from frequencies that are concentrated in the 125 to 8000 Hz range to meet the ANSI standards. The external surface having cladded with noise reduction coefficient rated fabric and the encapsulated panels will be secured to floor with mild steel track frame work made up of 16 gauge of "U'' channel approx size 20mmx105mmx40mm and fastened to the floor complete all as specified and as directed. | 35 | Sqm | 38,888 ₹13,61,080 | 36,000 ₹12,60,000 | 38,999 ₹13,64,965 | 24,800 ₹8,68,000 Lowest | 41,000 ₹14,35,000 | 42,000 ₹14,70,000 |
| 3.00 | All as per Serial item No. 2 here-in-before but for ceiling panel having mild steel angle frame work (16 gauge mild steel powder coated ''L'' angle of size 50x50mm) to support the ceiling panel. | 10.5 | Sqm | 38,888 ₹4,08,324 | 36,000 ₹3,78,000 | 38,999 ₹4,09,489.5 | 24,800 ₹2,60,400 Lowest | 41,000 ₹4,30,500 | 42,000 ₹4,41,000 |
| 4.00 | M&L for floor of 8mm thick underlay of neoprene rubber sheet over which 5mm thick loop pile carpet, the material attenuates the low frequency waves 125 to 4K Hz and less interference from low frequency sound complete all as specified and as directed. | 10.5 | Sqm | 11,188 ₹1,17,474 | 10,000 ₹1,05,000 | 15,000 ₹1,57,500 | 8,500 ₹89,250 Lowest | 16,500 ₹1,73,250 | 18,000 ₹1,89,000 |
| 5.00 | M&L for door frame made upto 19mm thick plywood box type of size approx (50mmx300mm) and 3mm thick non woven cladded. The groove to facilitate perfect sealing of the door shutter. The door shutter to be made up of 12mm thick plywood (double layer) insulated internally and externally covered with 3mm nonwoven complete all as specified and as directed.
Note : (a) The quoted rate shall be all inclusive with suitable door handle, lock and necessary hardware.
(b) Double doors and single door frameworks constitute this requirement. | 3 | Each | 1,10,000 ₹3,30,000 | 95,000 ₹2,85,000 | 1,05,000 ₹3,15,000 | 80,586 ₹2,41,758 Lowest | 1,24,800 ₹3,74,400 | 1,23,500 ₹3,70,500 |
| 6.00 | M&L for observation window comprising of double layers 8mm thick glass with the inside glass being placed at an angle of 45 degrees. If desired, this is secured to a wooden frame work with rubber gaskets and silica gel (size: 2x2ft) complete all as specified and as directed. | 1 | Set | 99,000 ₹99,000 | 90,000 ₹90,000 | 85,000 ₹85,000 | 40,293 ₹40,293 Lowest | 79,000 ₹79,000 | 79,999 ₹79,999 |
| 7.00 | M&L for centre partition wall with double layered gypsum of 12mm with GI frame work and insulated with glass wool complete all as specified and as directed. | 6.7 | Sqm | 27,990 ₹1,87,533 | 25,000 ₹1,67,500 | 28,000 ₹1,87,600 | 14,100 ₹94,470 Lowest | 27,500 ₹1,84,250 | 26,660 ₹1,78,622 |
| 8.00 | Taking down indoor split type AC (only indoor unit) carefully and kept in safe coustody and refixing the same at existing position as per direction of Engineer-In-Charge including necessary fasteners and necessary tools and equipments complete all as specified and as directed.
Note: Any damage or leakage of refrigerent caused during taking down of the AC shall be rectified and the quoted rate shall be all inclusive. | 1 | Each Job | 4,850 ₹4,850 | 4,500 ₹4,500 | 5,000 ₹5,000 | 3,500 ₹3,500 Lowest | 4,900 ₹4,900 | 4,665 ₹4,665 |
| 9.00 | Taking down ceiling and wall mounted fan carefully and kept in safe custody and refixing the same at existing position as per direction of Engineer-In-Charge including necessary fasteners, tools and equipments complete all as specified and as directed.
Note : Any damage caused during taking down of the items shall be rectified and the quopted rate shall be all inclusive. | 4 | Each Job | 1,350 ₹5,400 | 600 ₹2,400 | 700 ₹2,800 | 300 ₹1,200 Lowest | 600 ₹2,400 | 565 ₹2,260 |
| 10.00 | Taking down carefully point wiring (light, fan, socket, etc.) complete including battens and fittings such as switches, ceiling rose, light fittings, regulators, sockets, etc. and making good to disturbed surfaces of walls, floors, etc. complete all as specified and directed. | 10 | Point | 661 ₹6,610 | 500 ₹5,000 | 350 ₹3,500 | 150 ₹1,500 Lowest | 290 ₹2,900 | 450 ₹4,500 |
Tender Value
Refer Docs
EMD Value
₹48,420
Closing Date
6 Aug 2026, 6:00 pmClosed
GE (AF) JORHAT
JORHAT
SPECIAL REPAIR OF SOUND PROOFING FOR ENT AUDIOMETRY ROOM AT 5 AFH UNDER GE (AF) JORHAT
2026_MES_757375_3
8764/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) JORHAT
AS PER NIT
9 documents required · 9 mandatory
₹500
GE (AF) JORHAT
₹48,420
Yes
21 Aug 2026
16 Jul 2026
8 Aug 2026
16 Jul 2026
6 Aug 2026
24 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including
cover fillets complete all as specified and as directed. | 56 | Sqm | - | - |
| 2 | M&L for side panelling with GI (galvanised iron) box panel frame work of 24 gauge perforated to an extent of 70% and of 4" thick box panels of (8'x1') in dimension. The panels with 4" (100mm) thick box panel should have infill acoustic material density varies from 32 & 16 Kg/cum (glass wool as acoustic material). The material should have the ability to attain 50% insertion loss and attenuate incident sound energy from frequencies that are concentrated in the 125 to 8000 Hz range to meet the ANSI standards. The external surface having cladded with noise reduction coefficient rated fabric and the encapsulated panels will be secured to floor with mild steel track frame work made up of 16 gauge of "U'' channel approx size 20mmx105mmx40mm and fastened to the floor complete all as specified and as directed. | 35 | Sqm | - | - |
| 3 | All as per Serial item No. 2 here-in-before but for ceiling panel having mild steel angle frame work (16 gauge mild steel powder coated ''L'' angle of size 50x50mm) to support the ceiling panel. | 10.5 | Sqm | - | - |
| 4 | M&L for floor of 8mm thick underlay of neoprene rubber sheet over which 5mm thick loop pile carpet, the material attenuates the low frequency waves 125 to 4K Hz and less interference from low frequency sound complete all as specified and as directed. | 10.5 | Sqm | - | - |
| 5 | M&L for door frame made upto 19mm thick plywood box type of size approx (50mmx300mm) and 3mm thick non woven cladded. The groove to facilitate perfect sealing of the door shutter. The door shutter to be made up of 12mm thick plywood (double layer) insulated internally and externally covered with 3mm nonwoven complete all as specified and as directed.
Note : (a) The quoted rate shall be all inclusive with suitable door handle, lock and necessary hardware.
(b) Double doors and single door frameworks constitute this requirement. | 3 | Each | - | - |
| 6 | M&L for observation window comprising of double layers 8mm thick glass with the inside glass being placed at an angle of 45 degrees. If desired, this is secured to a wooden frame work with rubber gaskets and silica gel (size: 2x2ft) complete all as specified and as directed. | 1 | Set | - | - |
| 7 | M&L for centre partition wall with double layered gypsum of 12mm with GI frame work and insulated with glass wool complete all as specified and as directed. | 6.7 | Sqm | - | - |
| 8 | Taking down indoor split type AC (only indoor unit) carefully and kept in safe coustody and refixing the same at existing position as per direction of Engineer-In-Charge including necessary fasteners and necessary tools and equipments complete all as specified and as directed.
Note: Any damage or leakage of refrigerent caused during taking down of the AC shall be rectified and the quoted rate shall be all inclusive. | 1 | Each Job | - | - |
| 9 | Taking down ceiling and wall mounted fan carefully and kept in safe custody and refixing the same at existing position as per direction of Engineer-In-Charge including necessary fasteners, tools and equipments complete all as specified and as directed.
Note : Any damage caused during taking down of the items shall be rectified and the quopted rate shall be all inclusive. | 4 | Each Job | - | - |
| 10 | Taking down carefully point wiring (light, fan, socket, etc.) complete including battens and fittings such as switches, ceiling rose, light fittings, regulators, sockets, etc. and making good to disturbed surfaces of walls, floors, etc. complete all as specified and directed. | 10 | Point | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.68 MB
BOQ_872635.xls
BOQ • 0.28 MB
8764tender.pdf
Tender Documents • 1.46 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .