Executive Engineer
Office of Executive Engineer WSS Divn No 3 Amritsar
Repair of AC Plant in 200 Bedded Super speciality block at GND Hospital Amritsar
2020_WSS_53705_1
5346-5400
Open Tender
Civil Works
Item Rate
60 days
Amritsar
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Yes
TIA
₹19,000
Yes
12 Oct 2020
18 Sept 2020
25 Sept 2020
18 Sept 2020
24 Sept 2020
18 Sept 2020
Amount
Unlock and updating Chiller Unit No. 1 Micro Processer in AC Plant.
Reparing of Chiller Unit No.3 Pump down & collect gas R-22 in cylider, open chiller end cover reparing, partition Gasket change Pressure Testing with nitrogen upto requried level.
Providing and Fixing new water flow switch, Drain water Refitting new Switch, Electrical Connection etc. (Main Chiller Water line of all unit (1-5)
Providing & Fixing new main Switch As per Suitable size and Amp of unit No. 5 Make LT/LK 250 Amp. of main panel.
Providing & Fixing new crank case heater, Opening Heating case of before oil drain, removing old heater with drill Machine, Refitting new Heater & Electirical Connection.
Providing Charging Compressor Oil. Freezol 68, Removing old oil, flushing the compressor Housing with Petrol. Providing new gasket & charging compressor oil. (unit No. 1 to 5)
Complete overhauling of condenser pump & chiller Pump. Replacement of both Ball Bearing, gland packing of condenser Pump in AC plant Room.
Providing & Fixing new viscous filter/fine filter suitable size of AHU. (As per Requirment) (22 Pre +22 fine =44)
Providing & Fixing new V-Belt of AHU Blower and motor as per site condition.
Modification & Reparing of OT duct As per size with G.I. Sheet Fabrication work at 1st floor.
Reparing of Emergency AHU Room Air Leakage with Board/Glass of suitable size material. (Ground floor to 5th Floor)
Reparing of AHU Room window & partition as per Requirment.
Descaling with Cemical of 5 No. Condenser & Alied work at plant room.
Recharging R-22 Gas Top up in all unit. 1-5 at plant room.
Providing & Fixing Air Purging valve for chiller & condenser at plant room.
Providing & Fixing Volt Meter Digital at main panel in plant room.
Providing & Fixing Safe Trip make GE 63 Amp. at plant room.
Supply of Common Salt for Water Softning Plant. (for each month 250 Kg.) 250 x 12 =3000 Kg. At plant room.
Providing & Fixing New Transreducer for Chiller units oil,Suction, Discharge. Make Danfoss or equillent. At unit No. 1, 4 & 5 .
Providing & Fixing Chiller water senssor in chiller water unit 1,2,3,4.
Repair & Replacement of Teflon seat of compressor service valve unit no. 3-4 at Plant room.
Providing & Fixing Flot valve for chiller water makeup tank & cooling tower tank. Size 20mm
Providing & Fixing Strip heater 3Kw. in AHU from 1-13.
Providing & Fixing Strip heater 2Kw. in AHU from 1-13.
Providing & Fixing Contactor ML-1.5 L/T for heater control at1st floor.
Servicing of Electrical Control panel of plant and Chiller unit panel at plant room.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .