Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹6.6 L+₹54,510 (8.96%)Rejected-AOC | L2 | Rejected-AOC Accepted | |
| 3 | L3₹7.6 L+₹1.5 L (24.5%)Rejected-AOC HAMIRPUR ROAD NEAR BUS STAND UNA DISTT UNA HP | UNA | HIMACHAL PRADESH | 174301 | L3 | Rejected-AOC Accepted | |
| 4 | L4₹8.6 L+₹2.5 L (41.5%)Rejected-AOC | L4 | Rejected-AOC Accepted | |
| 5 | L5₹9.0 L+₹3.0 L (48.7%)Rejected-AOC | L5 | Rejected-AOC Accepted |
Tender Value
₹12.9 L
EMD Value
₹25,872
Closing Date
23 Jan 2025, 5:00 pmClosed
Executive Engineer
Jal Shakti Division Thanakalan
Providing laying jointing and testing of R/main S/E of pumping Machinery
2025_HPIPH_98128_1
UNA-UNA03-733
Open Tender
Civil Works
Lump-sum
120 days
Thanakalan
Please refer Tender documents.
8 documents required · 8 mandatory
₹800
₹25,872
20 Mar 2025
16 Jan 2025
24 Jan 2025
16 Jan 2025
23 Jan 2025
16 Jan 2025
16 Jan 2025 - 23 Jan 2025
Amount
Excavation in foundations and trenches (for pipes and pits for other civil structures) upto all depths in all kinds of soil such as pick work, jumper work and saturated soil and paved surfaces including bailing or pumping out of water, chiseling or wedging out of same where blasting is prohibited in all leads and lifts including trimming and dressing of sides, leveling of beds to correct grade including shoring, strutting, planking timbering and dewatering wherever required, stacking usable and unusable material/soil separately and after laying jointing and testing of pipes, returning the usable soil in 15 cm layer by ramming and watering and then disposing of all surplus excavated soil/unusable material as directed within all leads and lifts including cost of diversion of traffic, night signal boards, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects as per the direction of Engineer-in-charge.
Laving Jointing and Testing in trenches Gl Pipe flanged/butt welded pipe of below mentioned dia and grade conforming to IS 1239-2004 (with latest ammendments The MS flanges are to be provided 5% of total joints as per table below conforming to 6392-1971 (Latest uptodate ammendments) and welding of M S. flanges with pipe as per IS 816-1965 with electrode as per IS 814-1967 including required Nos. and size of M.S nuts and bolts as per IS 1369-1967 and compressed asbestos fibre jointing gaskets sheet not less than 3mm thick as per IS. 27121-1965 The welding of flanges to be done on both faces in three layers in each face to make the joints leak proof including all kind of specials such as bends of all degree to be made from parent tube, short pieces, tail pieces all made from parent tube and to the entire satisfaction of enginer-m-charge. The pipes end should be bevelled suitable for butt welding The circumferencial butt welded joints (95% of the total joints) by electrical arc welding to following dia & class pipes, welding of pipes to be done in three layers to make the joints leak proof and to achieve the minimum effective throat thickness of weld conforming to IS-816-1969 specifications, by using welding electrodes of 2.5 mm to 6.3 mm of Advanı oerlikon (Adore)-CITOJET/ESAB make, conforming to IS 814-1991, at site of work complete in all respects and including DPT test for joints & manual/mechnical handing of pipes. The laying of pipe shall confirm to BIS-5822 (with latest ammendments uptodate), including all kind of specials such as bends of all degree to be made from parent tube. short pieces tail pieces all made from parent tube within all leads and lifts (Earth work in trenches, M. S. flanges and butt will be measured and paid for separately)
GI pipe 125mm dia (M.C)
GI pipe 150 mm dia (M.C)
Providing welding and fixing of MS flanges @ 5% of joints, conforming to following tables as per IS 6392-1971 (Latest with upto date amendments) and welding of MS flanges with GMS/MSERW pipes in three layers on both faces i.e two layer on outer faces and one layer on inner face to make the joint leak proof (The cost of providing and laying of MSERW pipes to be measured and paid for separately). The welding of flanges should conform to IS 816-1969 with electrodes as per IS: 814-1991 and required number of nuts and bolts conforming to IS 1364. the thickness of gasket not less than 3.00 mm conforming to IS 2712-1998. The work shall be done as per entire satisfaction of engineer in charge within all leads and lifts.
GI pipe 125mm dia (M.C) with wall thickness 4.80mm. Table-5
GI pipe 150 mm dia (M.C) with wall thickness 4.80mm. Table-5
Providing Circumferencial Butt welded joints by electrical arc welding to below mentioned dia and wall thickness MSERW pipe welded in three number of weld runs so as to achieve the minimum effective throat thickness of weld conforming to IS 816-1969 specifications, by using welding electrodes of 2.5 mm to 6.3 mm of Advani Oerlikon (Adore)-CITOJET/ESAB make, conforming to IS 814-1991 including Die pentration test, at site of work complete in all respects, including manual/machanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer in charge.
GI pipe 125 mm dia (M.C)
GI pipe 150 mm dia (M.C)
Submersible Pumping Machinery For Tube Well at Takka Supply of submersible pumping set of reputed make such as KSB/ Calama /BS/ Worthigton /Sabar/ Seerex/Johnston Amrut/Lubbi/Hindustan/Groundfos confirming to latest relevent Bis. The pump should be fitted with free fine impeliers of suitable alloys as per BIS: 5659-1978 with upto date amendments, suitable for raw / clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to submersible motor of same as that of offered submersible pump make confirming to BIS;9283-1979 with upto date amendments, totally dust and water proof for submersible pump, duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed, lubricated bearing and provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear tear.It should also be fitted with a device to make up expantion of water with heating of motor. The pumpset should include water level guard i/c cable, errection clamps, cable clips and depth gauge etc. and suitable for opertion on data given .
Discharge = (Q) 10.07 LPS
Total Head = ( H) 125.63 Mts.
a) SWL in Tubewell = 12.00 Mtr. bgl.
c) R.L. point of discharge =408.85 Mtr.
d) Seasonal fluctuation + draught condition + bowl assembly. = 9.00 Mtrs.
e) Drawdown in Tubewell =15.00 Mtrs.
f) R.L of lowest point of pumpset installation = 399.00 Mtrs.
g) Static column lift = 106.00 Mtrs.
Rising main.
Length 450 Rmt.
Dia meter. 125 mm
Class GMS Pipe (MG)
Column Pipe.
Length 85.00 Mtr.
Dia 125 mm
Class GMS. (M)
Pumping hours = 16.00 Hours
Altitude of installations above M.S.L. 450 Mtr.
Characteristic of water.
a) Temperature 20 Deg Cel.
b) Turbidity ________JTU.
c) Allkanity. ___________mg/ l Ca Co3
d) Size of solids ____________mm
e) others
Depth of T/well = 154.00Mtr.
Dia of T/ well assembly 300mm & 200 mm
Length of assembly pipe. 70 meter .
Dia of housing pipe 300 mm
Length of housing pipe. 64.00 meter
OPERATING CONDITIONS.
Type of Current :- A.C.Three Phase.
Frequency:- 50 Cycles /Sec.
Rated Voltage 415 +/- 15 % Volts.
System of earthing:- Double Loop earthing as per BIS 3843-1987 Latest.
Speed of Revolution ____________ RPM 2900
MOTOR.
Ref. to BIS code BIS 9283-1979 with upto date amendments.
Type of enclosure of motor: As per BIS ; 4691-1985 ( latest )
Mechanical out put in H.P.
Class of insulation : Class B
The motor should be able to withstand initial current of 2.50 times the rated current for two minutes without suffering damages of permanent deformations.
Ref. to BIS code ; BIS ; 5659-1978 with upto date amendments.
Driver Type: Electric driven.
Operating Range: -15 % to+10 % of Total head at duty point.
Delivery size of Pump : ________( To be quoted by tenderer.)
Providing ICTP Main Switch with HRC fuses of L&T/ Havells make and having capacity 30% extra of the operational rating as per IS : 4864-1978 with upto date amendments. i) Make : ii) Type : iii) Capacity : 100 amp.
Providing MS Sheet steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections. Panel/ Switch Board i) Drawing. ii) Layout Plan
MCCB of kilburn / L&T/ Havells make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments. i) Make : ii) Type : iii) Range 100 amp. iv) Capacity
ELCB of recommended make Killburn/ L&T /Havells as per IS ; 2516-1985 with up to date ammendments and of suitable range which should have control box , operating handle & trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. ELR i) Make : ii) Type : iii) Range 80Amp. iv) Capacity
The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage, reverse phasing, overloading and phase voltage difference as per IS; 3842 ( Latest Edition )i) Make : ii) Type : iii) Range 0-500.
Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS ; 8084-1976 and IS : 11353-1985 read with BIS ; 5578 -1985 with upto date amendments including. 3 phase indicators i) Make : ii) Type : iii) Rating
Three phase indicator lamps complete with toggle switches for individual motors as per IS 3452 (P- I&II ) with upto date amendments. 3 Phase indicators
Capacitor of BHEL / L&T make as per IS ; 2834-1968 with upto date amendments, to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter/ IEC make) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments .Rate of capacitor will be approved by HPSEB. i) Make : ii) Type : iii) Range. 9 KVAR
Providing suitable starter of L&T/ Havell's /BHEL/MEI/Killburn make as per IS :13947-II with upto date 'amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic 'type overload release and dashpot, time lag, under voltage release, with or without 'initial oil filling as the case may be with Air Break. Type Star Delta with single phase preventor as per IS ;1248 ( P-V ) 1983 with up to date amendments. Single Phase Preventor i) Make : ii) Type : iii) Range.
Providing and fixing double flanged Cast steel Sluice valve of Leader / Kirloskar Brand make for the delivery line of pump and capable of withstanding the normal seat pressure and as per IS :- 780-1992 with latest ammendments i) Make : ii) Type : iii) Make :- Cast steel Class PN-I for Column Pipe 125 mm dia
Providing and fixing pressure gauge of Prega / Precision make complete with all accessories such as stop cock, copper tubing as per IS ; 3624-1987 with upto date amendements. i) Make :
Supply of PVC jointless, flat water proof cable with copper conductor as per BIS 694-1998 latest with upto date ammendments of Havells/ Finolex make suitable for the pumpsets offered from MCB to motor including all other electrical equipments / accessories such as thimble, flexible pipe, solder, nuts and bolts, cable glands, clips etc, laid in pipes or trenches under floor. The type, size and make shall be subject to approval of HPSEB authorities. i) Make : Finolex/ Havells ii) Size 3x 10 mm2 iii). type- IV capacity V Core-3
Lowering of GMS Column pipefor assembly 125 mm dia including MS flanges' of Table 17 as per IS : 6392-1971 with upto date amendments, rubber/asbestos gasket of min. 3mm thickness as per IS 2712-1979 and required numbers of nuts and bolts as per IS ;1364-1983 . The Column pipe shall be as per relevent IS Code and to withstand 1.50 times total head stipulated under Item No. 2.01 The Column pipe should be extended upto 5 mtr. beyond the outer wall of the pump house in the direction of Rising main . The Column pipe should be properly jointed with the Rising main including all necessary accessories like increaser / reducer, flanges, bends etc, including supporting clamps (2Nos.) at the top of T/well assembly, and as per the direction of Engineer - in - Charge. (The pipe shall be supplied by the Department free of cost from Divisional Store Barnoh. Column Pipe 125 mm dia GMS pipe(M)
Installation of all items appearing as above as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge.
Providing and laying copper PVC insulated armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 (P-I ) 1988 or latest with upto date amendments of Seimen /Gloster / IEC / ICC / EICO / National / Grandlay /Finolex/ Havells make including all other accessories such as thimble, flexible pipes, solder nuts and bolts, cable glands etc. laid in pipes of trenches under floor. Armoured Power Cable A) Supply Side 3 x 16 mm2 From meter of HPSEB to Bus Bar and Switch) i) Size 3 x 10 mm 2 ii) Make Finolex/Havells. iii) Type iv) Capacity v) Core 3.
Providing and fixing double loop earthing with G.I. Flat suitable thickness electrode complete with material such as thimble, nuts and bolts, charcoal, salt, common as per IS ; 3043-1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect as per the dirction of the Engineer - in - Charge.
Submersible Pumping Machinery For Tube Well at Lower Basal Supply of submersible pumping set of reputed make such as KSB/ Calama /BS/ Worthigton /Sabar/ Seerex/Johnston Amrut/Lubbi/Hindustan/Groundfos confirming to latest relevent Bis. The pump should be fitted with free fine impeliers of suitable alloys as per BIS: 5659-1978 with upto date amendments, suitable for raw / clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to submersible motor of same as that of offered submersible pump make confirming to BIS;9283-1979 with upto date amendments, totally dust and water proof for submersible pump, duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed, lubricated bearing and provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear tear.It should also be fitted with a device to make up expantion of water with heating of motor. The pumpset should include water level guard i/c cable, errection clamps, cable clips and depth gauge etc. and suitable for opertion on data given .
Discharge = (Q) 19.60 LPS
Total Head = ( H) 38.34 Mts.
a) SWL in Tubewell = 00.00 Mtr. bgl.
c) R.L. point of discharge =349.75 Mtr.
d) Seasonal fluctuation + draught condition + bowl assembly. = 9.00 Mtrs.
e) Drawdown in Tubewell =15.00 Mtrs.
f) R.L of lowest point of pumpset installation = 399.00 Mtrs.
g) Static column lift = 22.00 Mtrs.
Rising main.
Length 450 Rmt.
Dia meter. 150 mm
Class GMS Pipe (MG)
Column Pipe.
Length 22.00 Mtr.
Dia 150 mm
Class GMS. (M)
Pumping hours = 16.00 Hours
Altitude of installations above M.S.L. 450 Mtr.
Characteristic of water.
a) Temperature 20 Deg Cel.
b) Turbidity ________JTU.
c) Allkanity. ___________mg/ l Ca Co3
d) Size of solids ____________mm
e) others
Depth of T/well = 143.00Mtr.
Dia of T/ well assembly 300mm & 200 mm
Length of assembly pipe. 70 meter .
Dia of housing pipe 300 mm
Length of housing pipe. 64.00 meter
OPERATING CONDITIONS.
Type of Current :- A.C.Three Phase.
Frequency:- 50 Cycles /Sec.
Rated Voltage 415 +/- 15 % Volts.
System of earthing:- Double Loop earthing as per BIS 3843-1987 Latest.
Speed of Revolution ____________ RPM 2900
MOTOR.
Ref. to BIS code BIS 9283-1979 with upto date amendments.
Type of enclosure of motor: As per BIS ; 4691-1985 ( latest )
Mechanical out put in H.P.
Class of insulation : Class B
The motor should be able to withstand initial current of 2.50 times the rated current for two minutes without suffering damages of permanent deformations.
Ref. to BIS code ; BIS ; 5659-1978 with upto date amendments.
Driver Type: Electric driven.
Operating Range: -15 % to+10 % of Total head at duty point.
Delivery size of Pump : ________( To be quoted by tenderer.)
Providing ICTP Main Switch with HRC fuses of L&T/ Havells make and having capacity 30% extra of the operational rating as per IS : 4864-1978 with upto date amendments. i) Make : ii) Type : iii) Capacity : 63 amp.
Providing MS Sheet steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections. Panel/ Switch Board i) Drawing. ii) Layout Plan
MCCB of kilburn / L&T/ Havells make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments. i) Make : ii) Type : iii) Range 100 amp. iv) Capacity
ELCB of recommended make Killburn/ L&T /Havells as per IS ; 2516-1985 with up to date ammendments and of suitable range which should have control box , operating handle & trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. ELR i) Make : ii) Type : iii) Range 63Amp. iv) Capacity
The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage, reverse phasing, overloading and phase voltage difference as per IS; 3842 ( Latest Edition )i) Make : ii) Type : iii) Range 0-500.
Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS ; 8084-1976 and IS : 11353-1985 read with BIS ; 5578 -1985 with upto date amendments including. 3 phase indicators i) Make : ii) Type : iii) Rating
Three phase indicator lamps complete with toggle switches for individual motors as per IS 3452 (P- I&II ) with upto date amendments. 3 Phase indicators
Capacitor of BHEL / L&T make as per IS ; 2834-1968 with upto date amendments, to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter/ IEC make) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments .Rate of capacitor will be approved by HPSEB. i) Make : ii) Type : iii) Range. 5 KVAR
Providing suitable starter of L&T/ Havell's /BHEL/MEI/Killburn make as per IS :13947-II with upto date 'amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic 'type overload release and dashpot, time lag, under voltage release, with or without 'initial oil filling as the case may be with Air Break. Type Star Delta with single phase preventor as per IS ;1248 ( P-V ) 1983 with up to date amendments. Single Phase Preventor i) Make : ii) Type : iii) Range.
Providing and fixing double flanged Cast steel Sluice valve of Leader / Kirloskar Brand make for the delivery line of pump and capable of withstanding the normal seat pressure and as per IS :- 780-1992 with latest ammendments i) Make : ii) Type : iii) Make :- Cast steel Class PN-I for Column Pipe 150 mm dia
Providing and fixing pressure gauge of Prega / Precision make complete with all accessories such as stop cock, copper tubing as per IS ; 3624-1987 with upto date amendements. i) Make :
Supply of PVC jointless, flat water proof cable with copper conductor as per BIS 694-1998 latest with upto date ammendments of Havells/ Finolex make suitable for the pumpsets offered from MCB to motor including all other electrical equipments / accessories such as thimble, flexible pipe, solder, nuts and bolts, cable glands, clips etc, laid in pipes or trenches under floor. The type, size and make shall be subject to approval of HPSEB authorities. i) Make : Finolex/ Havells ii) Size 3x 10 mm2 iii). type- IV capacity V Core-3
Lowering of GMS Column pipefor assembly 125 mm dia including MS flanges' of Table 17 as per IS : 6392-1971 with upto date amendments, rubber/asbestos gasket of min. 3mm thickness as per IS 2712-1979 and required numbers of nuts and bolts as per IS ;1364-1983 . The Column pipe shall be as per relevent IS Code and to withstand 1.50 times total head stipulated under Item No. 2.01 The Column pipe should be extended upto 5 mtr. beyond the outer wall of the pump house in the direction of Rising main . The Column pipe should be properly jointed with the Rising main including all necessary accessories like increaser / reducer, flanges, bends etc, including supporting clamps (2Nos.) at the top of T/well assembly, and as per the direction of Engineer - in - Charge. (The pipe shall be supplied by the Department free of cost from Divisional Store Barnoh. Column Pipe 150 mm dia GMS pipe(M)
Installation of all items appearing as above as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge.
Providing and laying copper PVC insulated armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 (P-I ) 1988 or latest with upto date amendments of Seimen /Gloster / IEC / ICC / EICO / National / Grandlay /Finolex/ Havells make including all other accessories such as thimble, flexible pipes, solder nuts and bolts, cable glands etc. laid in pipes of trenches under floor. Armoured Power Cable A) Supply Side 3 x 16 mm2 From meter of HPSEB to Bus Bar and Switch) i) Size 3 x 10 mm 2 ii) Make Finolex/Havells. iii) Type iv) Capacity v) Core 3.
Providing and fixing double loop earthing with G.I. Flat suitable thickness electrode complete with material such as thimble, nuts and bolts, charcoal, salt, common as per IS ; 3043-1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect as per the dirction of the Engineer - in - Charge.
Vijay Sharma Contractor (BID ID -473995)
SS ENGINEERING WORKS (BID ID -474006)
Ashutosh bali (BID ID -472980)
Sahil Chaudhary (BID ID -473883)
NARESH KUMAR (BID ID -473955)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .