Loading…
Loading…
Tender ID
Tender Value
₹37.4 L
EMD Value
₹74,890
Closing Date
17 Apr 2026, 12:00 pmClosed
Er. Gurpreet Singh Bhains
Office of the Executive Engineer, Electrical Division No. 1, Sector-9,Chandigarh.
PROVIDING FIRE ALARM/ PUBLIC ADDRESSABLE SYSTEM AT HIGH COURT EXTENSION, BLOCK A SECTOR-17, CHANDIGARH. (OLD DISTRICT COURTS COMPLEX).
2026_CHD_91703_1
E1/TN-14
Open Tender
Electrical Works
Percentage
60 days
Chandigarh
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹74,890
10 Apr 2026
10 Apr 2026
17 Apr 2026
10 Apr 2026
17 Apr 2026
10 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | DSR Item No. 28.2.1.2
Supplying, installation, testing and commissioning of microprocessor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, (As per Complete Item No. 1 of the DNIT) | - | - | - | - |
| - | Two Loop Panel. | 1 | Each | - | - |
| - | DSR Item No. 28.5.2 Supplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/ 1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. | 4,680 | P. Mtr. | - | - |
| - | DSR Item No. 1.20 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of Surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. | - | - | - | - |
| - | 25 mm | 2,800 | P. Mtr. | - | - |
| - | DSR Item No. 28.2.5 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required | 65 | Each | - | - |
| - | DSR Item No.28.2.19 Supplying, installation, testing & commissioning of fire fighter phone jack complete as required. | 16 | Each | - | - |
| - | DSR Item No.28.2.17 Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. | 3 | Each | - | - |
| - | DSR Item No. 28.5.3.2 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. | - | - | - | - |
| - | Speaker cable Two pair, 2-core, 1.5 sq.mm | 900 | P. Mtr. | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 5.30 MB
BOQ_112197.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .