Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹90.8 LAccepted-AOC | L1 | Accepted-AOC Agreement accepted. | |
| 2 | L2₹93.6 L+₹1.6 L (1.71%)Rejected-Finance | L2 | Rejected-Finance Second lowest tenderer for L2 | |
| 3 | L3₹94.9 L+₹2.9 L (3.11%)Rejected-Finance | L3 | Rejected-Finance Third lowest tenderer for L3 |
Tender Value
₹90.8 L
EMD Value
₹55,500
Closing Date
16 Dec 2024, 3:00 pmClosed
Superintending Engineer
Office of the Superintending Engineer, PWD., Building Construction and Maintenance Circle, Thanjavur-1
Construction of 4 Additional Class Rooms in Government Higher Secondary School at Thambikkottai Vadakadu in Pattukkottai block of Thanjavur District under NABARD RIDF XXX
2024_PWD_507966_1
17-06-2024-25
Open Tender
Civil Works - Buildings
Lump-sum
Thambikkottai Vadakadu
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹55,500
2 Apr 2025
6 Dec 2024
17 Dec 2024
6 Dec 2024
16 Dec 2024
6 Dec 2024
Amount
Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification.
S&F sand gravel mix (1:1) in foundation & basement in layers of not more than 15cm thick rammed,watered and well consolidated etc. complete complying with standard specification
Supplying and FILLING GRAVEL Supplying and filling in 'foundation and basement with filling sand in layers of not more than 15cm.thick well rammed watered and compacted -1m3 etc., complete complying with standard specification.
Supplying and FILLING M sand Supplying and filling in 'foundation and basement with filling sand in layers of not more than 15cm.thick well rammed watered and compacted -1m3 etc., complete complying with standard specification.
Cement Concrete 1:5:10 (One Cement, Five sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidation etc., complete.
Brick work in following Cement Mortar using best quality of country bricks of size 8-3/4" x 4-1/4" x 2-1/4" for foundation and basement including curing, etc., complete complying with standard specifiction..In Cement Mortar 1:5
Brick work in.In Cement Mortar 1:6 ( One Cement six crushed stone sand ) using best quality of country bricks of size 8-3/4" x 4-1/4" x 2-1/4" for foundation and basement including curing, etc., complete complying with standard specifiction
For Foundation and Basement
In Ground floor Superstructure.
In First floor Superstructure.
In Second floor Superstructure.
Supplying and erecting steel shuttering including necessary supports for plane surfaces for reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90 cm x 60 cm and 10 BG stiffened with welded mild steel angles of size 25 mm x 25 mm x 3 mm for boarding, laid over silver oak joists of size 10 cm x 6.5 cm spaced at about 75 cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)
For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.
For plane surfaces such as rectangular or Square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part thereof but not less than 30 cm, over the initial 3.00 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc., complete complying with standard specification and as directed by the department officers.
Providing and laying in position, Standardised Concrete Mix M-25 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 350 kglms and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
Foundation and Basement.
In Ground floor.
In First floor.
In Second floor.
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)
Cement Concrete 1:5:10 (One Cement, Five sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for Flooring laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification
Brick partition walls using best quality using Country Bricks of size 8-3/4" x 4-1/4" X21/4" in Cement Mortar 1:3 (One Cement and Three crushed stone Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)
For superstructure in Ground floor
For superstructure in first floor
Paving the floor with kota stone slab of size 600 x 600 of 18 / 20mm (un-polished) in all floors laid in of cement mortor 1:3 (one cement three crushed stone sand), 20mm thick and pointed with colour cement neatly including polishing with polishing stone and oxalic acid etc., so as to perfectly smooth and glossy and including hire charges for polishing machine and power consumption charges etc. The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
Paving the floor with pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three crushed stone sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Plain Cement Concrete 1:2:4 (one cement, two sand and four hard broken stone jelly) using 10-12mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.
Supplying and fixing fine polished Cuddapah Slab 38 / 40mm thick for cup-board arrangements including laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as direct.
Supplying and fixing of M.S.grill of approved design for gate, open courtyard, grill, grill work to doors and window openings etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including priming coat of best approved quality red oxide primer etc., complete
Manufacturing supplying and fixing in position of teracotta jally 20x20x5cm thick approved quality and design in cement slurry including cost of materials labour curing lifting fixing in position etc, complete complying with standard specification and as directed by the departmental officers in all floors.
Manufacturing supply and fixing of steel doors with following specification. MS angles of size 40x40x6 mm at 3.50 Kg /m are used for the outer frame and MS angles of size 35x35x6mm at 2.60 Kg /m for the shutter frames. Stiffeners with 32mm x 6mm at 1.50 Kg /m , MS flat is provided as the lockrail of the door and welded intact on both ends to the shutter frame. 18 g CR. sheet of best quality is laid as panel in the shutter frames. 18mm x 5 mm at 0.70 Kg /m MS flat is welded over the 32mm x 6mm at 1.50 Kg /m MS flat on the rear side of the doors sandwiching the CR. sheet for rigidity. Additional stiffeners with 18m x 5 mm at 0.70 Kg / m MS flats are provided diagonally on the rear side of the shutter. 2 nos of hinges is case of single leaf and 4 nos of hinges in case of double leaf shutter is provided 6 nos of hold fasts 200 mm length spliced at the ends are welded to the outer frame of the door.
Single leaf
Double leaf
Fabricating, supplying and fixing of steel Emergency exitdoor cum, emergency window with the following specification. M.S. angle in size 40x40x6mm are used for the outer frames and M.S. angle of sie 35x35x5mm for the shutter frame, stiffners with 32x6mm M.S. flats provided at required intervals in the shutter frames 18 guage CR sheet is laid as panel and welded instant for 1/3 bottom portion of the shutter, M.S. flat 18x5mm is welded over the 32x6mm M.S flat sandwitching the CR sheet in between additional stiffner with 18x5mm M.S. flat is provided diagonally at the rear-side of the shutter. The balance 2/3 portion at top is provided with grill at an average weight of 15kg/m2 and the top portion of operation emergency window is to be made of 25x25x3mm M.S. angle welded intact with CR sheet and 25x3mm M.S. flat at diagonally at the near side of the window at required interwals 6 Nos. of hinges to be provided,6 Nos of holdfast 100mm in length made of angle section spliced at the ends are welded to the outer frame of the door. Tower bolts 2 Nos. one at top and the other at the bottom are to be provided one aldrop is provided at an appropriate place in the door 2 Nos. of 'D' type handle for emergency window and 2 Nos of handle for door is to be provided at appropriate places. A tie bar is provided at the bottom of the outer frame to prevent twisting of frame during transportation of fixing. All members are given one coat of red oxide primer as directed by the departmental officers. The rate includes cost of materials, labour transportation to side of works, loading, unloading and all other incidental charges etc., complete.
Manufacturing, supplying and fixing in position of steel windows with the following specifications. Outer frames of windows made of 'Z' section F7D of size 33 x 25 x 3mm at 1.419kg/ m and mullion 'J' section (F4B) of size 46 x 25 x 3mm at 2.28 kg/ m and shutter section of made of F7D of 33 x 25 x 3mm at 1.419 kg / m as specified in IS 7452 / 1990. Each openable shuuter should not exceed a width of 600mm to enable separate operation and easy maintenance. The panel of the shutters to be covered with 18 gauge cold rolled sheet of superior quality and welded intact with shutter frames. Horizontal stiffeners using 18 x 5mm MSflat at 0.70 kg / m at 3 Nos. for each shutter and additional diagonal stiffeners of the same MS Flats at all the four corners of each shutters to the suitable length welded to the shutters, for holding the CR sheets in position firmly.
Four Leaves
Supplying and fixing in position steel balustrades using 20mm square rods spaced at 150mm centre to centre so that the two balustrades in each step shall be placed centrally and the top of balustrades connected with the hand rails (cost of hand rail shall be measured and paid separately) by means of MS flats of size 40mm x 6mm in the groove 40mm x 6mm provided at the bottom of hand rail; the bottom of balustrades shall be fixed on to the top of step concrete. An additional MS flat of size 50mm x 6mm shall be provided at the centre of balustrades connecting all square rods to the entire length including cost of square rods, flat and applying one coat of red oxide primer to the iron surfaces, etc., complete complying with standard specification and as directed by the departmental officers.
Supplying and fixing 40mm dia GI pipe for staircase hand rail including labour charges for cutting, welding and fixing with MS flats (excluding cost of flat), etc., as directed by the departmental officers
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900 mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete
Providing and fixing in position best approved quality PVC Rain water down fall pipe (4 Kg. /cm2 pressure ) of following diametres including cost of PVC pipes with necessary shoes, bends, clamps including cost of all materials, brass screws, nails, teakwood plugs and fixing of cast iron gratings at junction of parapet wall and the R.C.C. roof slab include finishing neatly etc. complete including cost of all materials, brass screws, nails, teakwood of removable iron gratings of appropriate size. The size of teakwood plugs to be used shall be 150 mm x 25 mm infront and 200 mm x 75 mm in all other sides with a depth of 10 cm. The PVC pipe shall be fixed with teakwood plugs by means of "U" clamps at the centre of the pipe line shall be fixed in addition to these for more than 3 Metres pipe length complying with standard specifications.
110 mm dia Two floor
Special ceiling plastering and finishing the exposed surface of RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc. with Cement Mortar 1:3 (One Cement and Three Sand) 10 mm thick including hacking the surfaces and providing Cement Mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc. in all floors complying with standard specification as directed by the departmental officers
Plastering with Cement Mortar 1:5 (One cement and Five sand),12 mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
Stucco plastering 12mm thick using blue granite chips of size 10mm and below over the existing base plastering with cement mortar 1:5, 12mm thick, etc., complete complying with standard specifications (SI 314)
Supplying and applying of Two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothly with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the departmental officers. (The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (water proof abrasive sheet) cost of putty blade, labour charges for grinding the joints and sand papering, two coats of putty, scrapping the putty area to level the surface smooth, etc., complete). The putty should be got approved by the Executive Engineer before use on work
White washing two coats with freshly burnt white shell lime in all floors including cost of lime, blue powder fevicol type gum, brushes, scaffolding charges, etc., complete complying with standard specification and as directed.
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Painting new iron works such as steel doors, windows, ventilators window bars balustrades etc. with two coats of best approved first quality and colour of synthetic enamel paint over the existing red-oxide priming coat in all floors.
Providing Black board in two layers with first layer in cement mortar 1:5 (one cement and five sand )20mm thick and the second layer in Combination mortar 1:1:6(one cement one lime and six sand) 20mm thick and providing band all round the block board in c.m 1:5 (one cement and five sand) for 20mm thick and 50mm width including cost of one coat of block oxide paint of approved quality complying with standard specification.
Supplying and fixing colour galvalume sheet roof of 0.47mm thick fixing in position with all necessary accessories complete complying with standard specification and as directed by the departmental officers.
ADD GST 18%
T T CONSTRUCTION (BID ID -1210107)
T K Srinivasan (BID ID -1210930)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .