Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹34.7 LAccepted-AOC 5 A LANE 1 GREATER KAILASH JAMMU J K 180011 | JAMMU | JAMMU AND KASHMIR | 180011 | L-1 | Accepted-AOC Being the lowest bidder | |
| 2 | L-2₹35.0 L+₹10,890 (0.31%)Rejected-AOC H NO 352 SECTOR 1 CHANNI HIMMAT JAMMU J K 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L-2 | Rejected-AOC Not being the lowest bidder |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
26 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL SANGRAM SINGH
GE Kaluchak Pin-900673 C/o 56 APO
REPAIR TO RCC WORK ROOF CHAJJA FACIA BALCONIES PARAPET WALL MUMTY AND GLASS PANES AT MIL STN RATNUCHAK UNDER GE KALUCHAK
2020_MES_357027_3
GE/KC/NIT-27/2020-21
Open Tender
Civil Works
Item Rate
180 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹80,000
Yes
12 Oct 2020
5 Sept 2020
28 Sept 2020
5 Sept 2020
26 Sept 2020
14 Sept 2020
5 Sept 2020 - 12 Sept 2020
60 days
Amount
B/R Portion
Demolition of brick work masonry built in cement mortar including all quoins, pillars etc. but excluding ashlars facing, dressed stone work and precast concrete articles complete all as specified and as directed.
Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6m mean radius built in in CM 1:6, complete all as specified and directed.
Dismantling of wrought iron or mild steel work any description complete all as specified and directed.
Mild steel framed works such as in grills, gratings, framed guard bars, etc. and similar work conforming to Fe-410-O or Fe-310-O grade, including bending, cutting and necesary welding required with fabrication and welding as required, complete all as specified and as directed.
Taking down cement plaster on bricks or stone wall/ceiling decayed surfaces of concrete from roof projection or RCC chajjas etc. including racking out joints, hacking for key, scrubbing down with water etc., complete all as specified and directed.
Taking down cement plaster and decayed concrete of any description, upto triple storey of building, from roof projection, chajjas etc and making good the decayed portion with cement mortar 1:3 mixed with water proofing compound or mixed with WPC or PCC 1:2:4 type B-0 (using 12.5mm graded aggregate) including necessary form work, fixing of GI wire netting 0.90mm dia and 12mm mesh in patches area n.exc 3.00 Sqm where ever required and finally finishing the surface with 15 mm thick cement plaster in CM 1:3 and applying two coats of white wash/colour wash/cement base paint/exterior emulsion paint to match the existing surface /finish, complete all as specified and as directed.
Rendering 15mm thick in cement mortar 1:4 on brick work or concrete surfaces finished even and smooth with out using extra cement, including mixing of water proofing compound as per manufacturer instruction complete all as specified and directed. Note : Water proofing compound shall be measured and paid seperately under respective items.
Rendering 15mm thick in cement mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement, complete all as specified and directed.
Rendering 5mm thick in cement mortar 1:3 on fair faces of brick work or concrete surfaces as in ceilings finished even and smooth without using extra cement, complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. And brushing neat cement slurry with 3.00 Kg of cement per Sqm complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds glazed with putty or fixed with beads, complete all as specified and directed.
3mm thick sheet glass ordinary quality and glazing with oil putty / screws, in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
3mm thick figured glass, pin head type and glazing with oil putty or wooden beads in square not exceeding 0.5 Sqm each complete all as specified and directed.
Complete removal of the existing roof treatment, any type viz. tarfelt or membrane surface or roof tiles etc. including grubbing up of tree roots and preparation of concrete surfaces by scrubbing down with steel brushes and cleaning with water all loose dirt/dust and applying the following Roof Treatment complete all as directed :- (a) Applying 1st course of 15mm thick screed bed with cement mortar1:4 over concrete surface. (b) Applying 1st course of bitumenous primer conforming to IS-3384 @ 0.4 Kg/Sqm over the screed bed. (c) Applying 2st coarse of a coat of blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
(d) Applying 3rd course of APP (Atactic Polypropylene) modified polymeric membrane 3mm thick weight not less than 3.6 Kilogram/Square Metre with 160 Grams/Square Metre non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat. (e) Applying 4th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kilogram/Square Metre. (f) Applying 5th course by applying two coats of aluminium paint on top of the surface.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizental face of groove with cement mortar 1:3 complete all as specified and as directed.
PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) with average thickness 50mm laid in two layers of 25mm thickness each finished even and smooth as in roof padding all as specified and as directed.
Plain cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in cills, lintels upto 1.5 metre clear span, steps, seismic and other similar band, plinth course, string courses, lacing courses, parapets and railing upto 60cm in height, copings, kneelers, apex stone, bed plates, kerbs etc and in similar works including weathering, slightly rounded or chamfered angles and throating and necessary form work complete, all as specified and as directed.
Dismantling water tanks exceeding 500 litres capacity but not exceeding 1000 litres, complete all as specified and directed.
Dismantling water tanks exceeding 250 litres capacity but not exceeding 500 litres, complete all as specified and directed.
Rotational moulded polyethylene water storage tanks tripple layer (cylindrical vertical with closed top) hoisted and fixed in position, including over flow and drain out pipe complete of 1000 litre capacity complete all as specified and directed.
Rotational moulded polyethylene water storage tanks tripple layer (cylindrical vertical with closed top) hoisted and fixed in position, including over flow and drain out pipe complete of 500 litre capacity complete all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required for repairs, cleaning etc. and hoisting if required reconnecting and refixing in position of water tanks exceeding 250 litres capacity but not exceeding 500 litres, complete all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required for repairs, cleaning etc. and hoisting if required reconnecting and refixing in position of water tanks exceeding 500 litres capacity but not exceeding 1000 litres, complete all as specified and directed.
Gun metal Gate valve with iron wheel head, screwed both ends for 20mm bore pipe fixed in repairs complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connection including cleaning for re-fixing or removal to store complete all as specified and as directed.
Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 15mm, complete all as specified and as directed.
Fixing only old steel tubing and connections in new or old position with all fittings retrieved from taking down here-in-before and fixed (walls, ceiling, floors, etc.) of 15 mm dia complete all as specified and as directed.
Taking up or down 20mm bore steel tubing and connection including cleaning for re-fixing or removal to store complete all as specified and as directed.
Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 20mm, complete all as specified and as directed.
Fixing only old steel tubing and connections in new or old position with all fittings retrieved from taking down here-in-before and fixed (walls, ceiling, floors, etc.) of 20 mm dia complete all as specified and as directed.
PVC pipes, single socketed, in any length of 110mm bore with rubber ring joints, fixed in repair to walls with Mild steel clamps, complete all as specified and directed.
PVC (SWR) bend, any radius of 110mm bore, equal or unequal, complete all as specified and directed.
Stack clamps made out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 75 to 110mm dia pipe complete all as specified and directed.
Preparation new plastered or previously untreated surfaces of ceilings and applying three coats of white wash, complete all as specified and directed.
Preparation new plastered surfaces of walls, chajjas, facias, parapets etc and applying two coats of cement base paint including one coat of cement primer complete all as specified and directed.
Preparation new plastered surfaces of Walls and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and as directed.
Preparation of new steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and as directed.
M/S ARUN ANAND
Bidder Name
M/S ARUN ANAND
NARESH KUMAR AND COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .