Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹10.0 CrAccepted-AOC | ₹10.0 Cr Quoted ₹10.2 Cr | L-1 | Accepted-AOC L-1 Bidder. |
| 2 | L-2₹10.7 Cr+₹49.4 L (4.84%)Rejected-Finance 100 GIRISH GHOSH ROAD DONBOSCO LILUAH HOWRAH WEST BENGAL 711202 | HOWRAH | WEST BENGAL | 711202 | ₹10.7 Cr+₹49.4 L (4.84%) | L-2 | Rejected-Finance Rejected. Other than L-1. |
| 3 | Rejected-Technical | - | - | Rejected-Technical Rejected. Being not enlisted in eligible category i.e. (a)(i). |
| 4 | Rejected-Technical 11 GURU NANAK MARKET AMBALA ROAD SAHARANPUR 247001 | SAHARANPUR | UTTAR PRADESH | 247001 | - | - | Rejected-Technical Rejected. Being adverse remarks in WLR for QE Jun 2024 of HQ CESC. |
Tender Value
₹11.1 Cr
EMD Value
₹8.8 L
Closing Date
5 Oct 2024, 6:00 pmClosed
CE SILIGURI ZONE
HQ CE SILIGURI ZONE, MES, SEVOKE ROAD, PO SALUGARA, DIST JALPAIGURI, PIN 734 008 (WB)
ADDITION / ALTERATION AND SPECIAL REPAIR TO MD ACCN INCLUDING PROTECTIVE AND ALLIED WORKS AT GANGTOK UNDER GE GANGTOK
2024_MES_668149_1
98796/GTK/SZ/E8
Open Tender
Civil Works
Item Rate
720 days
GANGTOK
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE GANGTOK
₹8.8 L
Yes
HQ CE SILIGURI ZONE
16 Dec 2024
31 Aug 2024
12 Oct 2024
31 Aug 2024
5 Oct 2024
21 Sept 2024
31 Aug 2024 - 5 Sept 2024
7 Sept 2024
Amount
Rough excavation not exceeding 1.5 m deep and getting out in soft/loose soil for foundation of Retaining wall complete all as specified and directed.
Excavation over areas n exc. 1.5m deep in soft/disintegrated rock for foundation of retaining wall complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out in hard/dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out as in hard/dense soil complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out as in soft/ loose soil complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation, manholes, erecting of poles etc. not exceeding 10 Sq.m on plan but not exceeding 1.5 mtr in depth and getting out in loose/soft soil complete, all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft and loose soil complete, all as specified and directed.
Removing excavated soil to a distance exceeding 1.5 Km and upto total distance of 5.0 km and depositing where directed complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (using 40 mm graded crushed stone aggregrate ) as in foundation filling and mass concrete complete, all as specified and directed.
M&L for PCC 1:3:6 type C2 (using 40 mm graded crushed stone aggregrate ) as in walls or retaining walls any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed.
M&L for plain cement concrete 1:3:6, type C-2 (using 40mm graded aggregate) as in toe wall etc complete all as specified and directed.
M&L for PCC 1:2:4 type B1 (using 20 mm graded crushed stoone aggregate ) as in coping, bed plates including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
M&L for RCC M25 design mix ( using 20 mm graded crushed stone aggregate) as in Beams, cantilevers, bressummers, lintels over over 1.5 meter span complete all as specified and as directed.
Use & waste of Formwork to faces of walls, retaining wall etc; vertical or batter for rough finished surfaces complete all as specified and directed.
M&L for TMT bar 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping of columns, hooking ends and binding wire and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified and directed.
M&L for MS TMT bars, 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete, all as specified and directed.
S&F for PVC (SWR) 75mm dia pipes single socketed, in any length as in weep holes complete all as specified and directed.
S&F of geosynthetic material 75mm dia as in weep holes cover fixed as per manufacture specification/instructions etc complete all as specified and directed.
M&L for Hand packing using Broken stone or boulders (any thickness) at back of PCC retaining wall and raising or lowering to the required level complete all as specified and directed.
Building Work: Dismantling of old Plain or corrugated steel sheeting, any gauge, thickness, any pattern roof coverings complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Taking down cement plaster of any description on brick or stone walls incl raking out joints hacking for key, scrubing down with water etc complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Demolition of concrete (un-reinforced) of any description and in any position not otherwise specially provided for complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specially provided for complete all as specified and directed.
Dismantling wall and ceiling board (fibre pulp, insulation etc) or insulation boards any thickness including cover fillets complete all as specified and directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and removal of dismantled materials/rubbish from site complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) each area n.exc 1.5 sqm complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) each area exc 1.5 sqm but n.exc 4 Sqm complete all as specified and directed.
M&L for 75mm thick PCC type C2 1:3:6 (using 20 mm graded crushed stoone aggregate ) as in plinth protection/Path/hardstanding finished the concrete surfaces even and smooth without using extra cement etc complete all as specified and directed.
M&L for forming 12 mm thick expansion joints (Thickness of concrete slab 75mm ) filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘B’ etc complete all as specified and directed.
M&L for 25 mm thick PCC (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) as in sub base of floor complete all as specified and directed.
S&F for 0.50mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheets of any colour and any pattern as approved having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws as in roof complete all as specified and directed.
S&F for 0.50mm thick pre-painted galvalume aluminium zinc coating GI based plain steel sheets of any colour having tensile strength of 550 Mpa as in ridges, valley, eaves, etc fixed with self tapping screws complete all as specified and directed.
Demolition of Brickwork/block or stone/ boulder masonry, built in cement mortar complete all as specified and directed.
M&L for pre cast cement concrete block masonry with solid blocks, exc. 10 cm in width and settting in cement mortar 1:6 type C1, (1:3:6) (using 20 mm graded stone aggregate) as per IS 383 complete all as specified and directed.
M&L for PCC 1:2:4 type -B-0 (12.5 mm gradede aggregate ) as in coping, or filling gap between gable wall and galvalume sheet etc. including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
M&L for 20mm thick rendering in cement plaster in CM (1: 4) in two layer and top layer 10mm thick shall be mixed with WPC @ 3% by weight of cement on fair faces of concrete surface of wall incl finish the surface even and fair without using extra cement complete all as specified and directed. NOTE : WPC shall be measured and paid separately.
Supply only Integral waterproofing compound complete all as specified and directed.
M&L for 15 mm thick rendering plaster on fair faces of concrete faces/ brick wall faces of smooth without using extra cement in CM 1:6 complete all as specified and directed.
M&L for 5 mm thick cement plaster 1:3 on fair faces of brick work or concrete surfaces in ceiling and finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for applying three coats of white wash on new plastered ceiling surface including preparation of new and previously untreated surfaces of ceiling complete all as specified and directed .
M&L for applying two coats of white wash on old plastered ceiling surface incl complete removal of existing surfaces etc complete all as specified and directed.
M&L for finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) etc complete all as specified and directed.
M&L for finishing walls with Acrylic Smooth exterior paint of required shade : Old work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) on old plasterd surface incl removal of existing surfaces etc complete all as specified and directed.
M&L for applying three coats of white wash on new plastered wall surface including preparation of new and previously untreated surfaces of wall complete all as specified and directed .
M&L for applying two coats of white wash on old plastered wall surface including preparation of old surfaces of wall complete all as specified and directed .
M&L for preparation of new plastered surfaces of walls applying two coats of distemper, oil emulsion, white or tinted over 3mm thick wall care putty in two layers (1.5mm each layer) complete all as specified and directed.
M&L for preparation of complete removal of existing treatement on old plastered surfaces of walls applying two coats of distemper, oil emulsion, white or tinted over 3mm thick wall care putty in two layers (1.5mm each layer) complete all as specified and directed.
S&F powder coated GI grid frame work for false ceiling comprising of the following sections for making partitions of 600 x 600mm size fixed to walls with rawl plugs & screws and hanged to roof with and including 1mm dia GI wire suspender of suitable length and butterfly clips, size of main tee shall be 28mm x 23mm x 0.3mm thick, cross tee shall be 24mm x 23mm x 0.3mm thick and wall angle shall be 20mm x 20mm x 0.3mm thick complete all as specified and directed.
M&L 4 mm thick E-board 595 x 595 mm in size, fixed with staple on snap gird as in ceiling with and including dusting of surface and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed.
All as per item No 52 above but openable/fix type window/ventilator complete all as specified and directed.
Applying two coat of DR Fixit flex 113 of DR Fixit for sunken portion treatment complete all as specified and directed.
M&L for PCC 1:7:12 type F2 (using 40mm graded crushed stone aggregate) as in filling and mass concrete complete all as specified and directed.
M&L for second class hard wood plain solid straight chowkats and frames wrought framed rebated on the solid rounded on chamfered put together with glue pinned and joints complete all as specified and directed.
M&L for 2nd class hard wood timber scantling of any size or in any position such as truss,purlin etc and if in repairs, to replace old and decayed timber (including piecing, scarfing, etc., of old and new timbers if required) and removing defective portions to store complete all as specified and directed.
S&F for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and directed.
S&F for Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel heaving a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification and drawing complete all as specified and directed.
S&F for 2nd class Plain framed, panelled shutter (two panel) 35mm thick with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F for 35mm thick 2nd class Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
M&L for 2nd class Plain fillets, square, rectangular or triangular in section, clean sawn, of sec area exc 6 & n.exc 13 Sqcm secured with nails or brads complete all as specified and directed.
S&F for MS but hinges 100mm long complete all as specified and directed.
S&F for MS but hinges 75 mm long complete all as specified and directed.
S&F for 150mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
S&F for 100mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
S&F for 150mm long Aluminium handles, cast type, anodised complete all as specified and directed.
S&F for 100mm long Aluminium handles, cast type, anodised complete all as specified and directed.
S&F for 75mm hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
S&F for 250 mm long aluminium anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium complete all as specified and directed.
M&L for preparation of new or previously untreated wooden surfaces of any description over 10 cm width or grith and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
S&F for Mild Steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 incl taking down old scrap iron grill complete all as specified and directed.
M&L for preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats synthetic enamal paint over one coat of red oxide primer complete all as specified and directed.
M&L for preparation of old steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat synthetic enamal paint complete all as specified and directed.
S&F stainless steel wire mesh 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in surface channels/drain including forming fair finished to drain channel complete all as specified and directed.
Roughening surfaces of old concrete floor or wall surface by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed.
M&L fo Non - skid Ceramic Coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, , in floors over and including 15mm thick screed in CM 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles complete all as specified and directed.
M&L for Non - skid Ceramic Coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm , in floors over and including 15mm thick screed in CM 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles complete all as specified and directed.
Ditto all as item No 79 above but on vertical surface of wall like skirting/dado etc on 10mm thick rendering in cm 1:4 complete all as specified and directed.
M&L for glazed coloured tile ( 300 x 450 mm/250 x 350mm) x 7 mm thick as in skirting/dado over & including 10 mm thick rendering in CM 1:4 set & jointed in neat cement slurry & pointed in white or coloured cement to match complete all as specified and directed.
S&F Vitrified Ceramic tiles (Light shade) 8 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed or bedding layer in CM(1:6) complete all as specified and directed.
Ditto all as item No 82 above but on vertical surface of wall like skirting/dado etc on 10mm thick rendering/ back coat in CM 1:4 complete all as specified and directed.
M & L for Granite 20mm thick (of any type/color) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and including 15mm thick screed in CM 1:6 etc complete all as specified and directed.
M&L for Drilling holes in granite or trap stone for bolts, pipes, etc. n. exc 25mm dia complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25mm thick (in single piece) over 15mm thick screed bed in CM (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade including rubbing and polishing complete all as specified and directed.
M&L for machine cut kota stone 20-25mm (in single piece) thick in riser of steps, skirting, dado and pillar etc including 10mm thick cement plaster in CM 1:3 set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified abd directed.
M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
M&L for RCC type B1 1:2:4 (using 20 mm graded stone aggregate) (Nominal mix)as in Slabs supported on walls, beams and columns in floors, roofs, landings, cover slab, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. NOTE : Re-inforcement shall be measured and paid separately.
Use & waste of Formwork (flat rough finished surfaces of concrete) to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed.
Use & waste of Formwork (flat rough finished surfaces of concrete) to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick etc complete all as specified and directed.
Demolition cement concrete reinforced as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed.
Use & waste of Formwork (flat rough finished surfaces of concrete) to chullah hoods, chajjas, troughs and similar items including edges etc complete all as specified and directed.
M&L for RCC type B1 1:2:4 (using 20 mm graded crushed stone aggregate) (Nominal mix) as in Chajja and the like complete all as specified & as directed. NOTE : Re-inforcement shall be measured and paid separately complete all as specified and directed.
S&F in repairs 18/19 mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screw as in cup boards ,shelves etc complete all as specified and directed.
S&F Continuous (piano) hinges, brass, Width of flaps (when open) in 30 mm bright finish or electrogalvanised etc complete all as specified and directed.
Taking down 20mm dia steel tubing and connections, including cleaning and refixing or removal to store complete all as specified and directed.
Taking down 25mm dia steel tubing and connections, including cleaning and refixing or removal to store complete all as specified and directed.
Supplying and laying of 20mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified etc complete all as specified and directed.
S&F galvanised steel water tubing 25 mm bore, medium grade with all fittings and fixed complete to walls/ceiling or laid in floors complete all as specified and directed.
S&F in repairs, 10 litre capacity low level PVC flushing cistern (white), syphonic action type, with inlet, ball valve, float, handle, fixed with cast iron bracket (of suitable size) and providing 32 mm dia PVC flush pipe and making all necessary connections complete all as specified and directed.
S&F in repairs Vitreous china squatting pan , 'Orissa' pattern, size 580 x 440 mm white, with integral foot rests complete including provision of cement concrete bedding complete all as specified and directed.
S&F in repairs white vitreous china wash down water closet pan (pedestal pattern) EWC, of size 520 x 360 x 390 mm with ‘P’ or `S' trap, including fixing bolts, Plastic water closet seat and cover, closed pattern with flat bottom, and mild steel chromium plated or aluminium anodised hinging device, making all necessary connections and making good the disturbed surfaces of floor complete all as specified and directed.
S&F in repairs vitreous china, white colour, flat back, wash hand basin of size 55 x 40CM fixed with brackets , including providing 32 mm dia PVC waste pipe , 32 mm bore CP waste coupling and making all necessary connections complete all as specified and directed.
S&F in repairs cromium plated central hole basin mixer/sink mixer Extended casted spout with 450mm long braided hoses complete all as specified and as directed.
S&F in repairs cromium plated wall mixer 15mm bore with 115mm long bend pipe for connection to over head shower (with Bush & piston diverter fittings) with aerator screwed down for 15mm bore GI Pipe or for brass ferrule, complete all as specified and as directed.
S&F in repairs Bib tap, long body cast copper alloy, chromium plated with crutch or butterfly handle, screwed down for 15mm bore GI Pipe or for brass ferrule including taking down old unserviceable one complete all as specified and directed.
S&F in repairs two way Bib tap, long body cast copper alloy, chromium plated with crutch or butterfly handle with health faucet, screwed down for 15mm bore GI Pipe or for brass ferrule complete all as specified and as directed.
S&F in repairs CP Toilet paper holder fixed to walls with chromium plated (CP) brass screws complete all as specified and directed.
S&F in repairs corner glass shelf 225x 225mm with CP steel frame complete all as specified and directed, complete all as specified and directed.
S&F in repairs Chromium plated shower rose 125 mm size with or without swivel joints,including fixing to steel pipe or union complete all as specified and directed.
S&F in repairs stop cock, cast copper alloy, chromium plated for 15mm bore GI Pipe or for brass ferrule, complete all as specified and as directed.
S&F in repairs PVC connections 15 mm size with PTMT nuts of length 450mm complete all as specified and directed.
S&F in repairs CP tubular towel rail 20mm dia, D type, 60cm long, complete all as specified and directed.
S &F in repairs Stainless steel towel ring round complete all as specified and directed.
S&F in repairs soap dish chromium plated body and Polycarbonate brackets including wall flange and screws etc complete all as specified and directed.
S&F in repairs stainless steel plate rack of 1mm thick and size 910x1000mmx250mm three tier complete all as specified and directed.
S&F in repairs stainless steel sink with draining board, made out of 1.00mm thick sheet for kitchen or laboratory with plug, washers waste pipe, cast iron cantilever brackets, connecting union overall size 915mmx460mm with bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F in repairs stainless steel cloth hanger 300x50x32 mm complete all as specified and directed.
M&L for Providing precast cement concrete solid building blocks or slabs 10cm thick (with plain or interlocking joints as directed) settting in cement mortar 1:6 type C1, (1:3:6) (using 20 mm graded stone aggregate) complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store etc complete all as specified and directed.
S&F in repairs 75 mm dia PVC floor trap of outlet, with gratings, including jointing to waste pipe fixed in PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) complete all as specified and directed.
S&F 110mm bore, PVC (SWR) pipes, single socketed in any length with rubber ring joints, laid in trenches or under floors , fixed on walls with necessary clips complete all as specified and as directed.
S&F 110 mm bore PVC (SWR) bend of any radius for PVC (SWR) pipes, fixed to walls or fixed to steel gutter complete all as specified and directed.
S&F 110 mm bore PVC (SWR) junction single,(Single T) equal or unequal complete all as specified and directed.
S&F 75mm bore, PVC (SWR) pipes, single socketed in any length with rubber ring joints, fixed on walls with necessary clamps etc complete all as specified and directed.
S&F 75mm bore PVC (SWR) bend of any radius for PVC (SWR) pipes, fixed to walls complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR) vent cowl fixed in position complete all as specified and directed.
S&F 75 mm bore PVC (SWR) junction single,(Single T) equal or unequal complete all as specified and directed.
S&F MS rolled section as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleat or other connecting plates confirming to Fe-410-W (Gde-E-250) complete all as specified and as directed.
M&L for up rooting of plant/ bushes from walls of bldgs up to extranded root and spraying of Muriatic Acid required quantity complete from any location of bldg up to ten stories and making good distributed surface with cement mortor (1:4) or cement concrete type C1 (1:3:6) using 20mm graded aggregate upto 10th floor complete all as specified and as directed. (NOTE : Necessary scaffolding shall deemed to be included in this item.)
M&L for PCC 1:3:6 type C1 (20 mm gradede aggregate ) as in coping, bed plates ,parepet,plinth course including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed.
M & L for 15mm thick rendering in cement plaster in CM (1: 4) on fair faces of stone masonry wall incl finish the surface even and fair with using extra cement complete all as specified and directed.
M&L for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirming to Fe-290 (Gde E165) complete all as specified and directed.
S&F in repairs Harrison rails, mild steel, chromium plated 25mm dia with fixing brackets, stops, rollers etc complete all as specified and directed.
Material and labour for hardcore of gauge n.exc.63mm (using broken stone or boulders) deposited, spread and levelled in layers not exc.15cm thick, watered and rolled/rammed to a true surface complete all as specified and directed.
M & L for Plain Cement concrete 75mm thick type B- 2, 1:2:4 (using 40mm graded crushed stone aggregate) as in hard stand /path etc including finish the surface even and fair without using extra cement etc complete all as specified and directed.
M&L chequered cement concrete tiles floor of size 250x250mm and 25mm thick set and jointed in grey cement pigment to match over 15mm thick screed bed in CM (1:6) complete all as specified and directed. Note: The rate of 15mm thick screed bed in CM 1:6 is to be included in this item.
M&L chequered cement concrete tiles floor of size 250x250mm and 25mm thick set and jointed in grey cement pigmen as in skirting/dado over 10mm backing coat in CM (1:4) complete all as specified and directed. Note: The rate of 10mm thick backing coat in CM 1:4 is to be included in this item.
M&L for pre-cast RCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in platform, slabs and the like etc including necessary form work and set in CM 1:4 complete all as specified & as directed. NOTE : Reinforcement shall be measured and paid separately.
M&L for MS TMT bars 6 to 8 mm dia cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M&L for 15mm thick rendering in CM (1: 4) on fair faces of brick work or concrete surfaces of wall incl finish the surface even and fair without using extra cement complete all as directed and specified.
Demolition & breaking up drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar, internal dia of pipe up to 200mm complete all as specified and directed.
M&L reinforced cement concrete pipes, class NP3, drain pipes of 200mm bore laid in trenches and jointed with collars complete all as specified and directed.
S&F DWCPE (SN8) 200 (OD)/175 (ID)mm diameter pipes confirming to IS 16098(Part-2) laid in trenches and jointed with fittings complete all as specified and directed.
M&L PCC (1:3:6) type C-2 concrete bed to drain pipes including packing under & haunching against the sides of pipes after they are laid & tested dia of pipe 200mm complete all as specified and directed.
M&L cutting into existing manhole for connecting new drains making good to pipe and rendering cutting out existing benching for & forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1 smooth finished & reforming benching as required dia of pipe 200mm complete all as specified and directed.
Security Fencing: M&L for rolled MS conforming to Fe-410-W (Gde-E250) quality-A joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) including necessary welding, febrication complete, all as specified and directed.
S&F Mild steel screw bolts of dia 11 to 15mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and directed.
S&F Mild steel plane bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips acomplete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed.
Supply only chain link for MS galvanisd fencing, any size or type complete all as specified and as directed. Note : Weight of chain links per Sqm is to be fixed by covening BOO at the end of GE office.
M&L for preparation of new or previously untreated steel surfaces of any description n.exc 10cm in width or girth applying two coats synthetic enamal paint over one coat of red oxide primer complete all as specified and directed.
Internal Electrification: Taking down carefully copper/aluminium point wiring (light, fan,socket or power) complete (including fittings such as switches, ceiling roses, pendants, regulatos, sockets ,light fittings etc ), removingb material to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperetel) and making good disturbed surfaces of walls, floors etc to match with existing surfaces complete all as specified and directed.
Taking down unserviceable submain wiring of any size two single core including earth wire and pvc conduit /casing capping and removing materials on site and making good the surface of walls etc complete all as specified and directed.
Taking down unserviceable distribution board or indoor panel of any capacity including wooden board and making good the disturbed surfaces of wall, etc including two coats of white /colour washing /distempering etc to match the existing complete all as specified and directed.
M&L for Point wiring with 1.5 sqmm (FRLSH) PVC insulated, single core, unsheathed, multi stranded 1100 volts grade, copper conductor cable drawn through in PVC conduit of suitable size for One Light/fan point controlled by single, one way, 240 volts, 50 Hz switch, concealed into ceiling/wall with proper colour coding, with and including continuous 1.5 sqmm PVC insulated single core multi stranded copper conductor cable earth continuity conductor connected to common earth and earth dolly including provn of modular metal flush boxes of appropriate size & thickness fixed flush to wall with modular cover plate with frame suitable for mounting modular switches, sockets etc all as specified and directed. NOTE : Quoted rate shall be include chase cutting, making good to the disturbed surfaces including plastering and painting to match with the existing colour.
All as per Srl Item No. 158 here-in-before but for each additional light point on the same board complete all as specified and directed.
All as per Srl Item No. 158 here-in-before but for One 3 pin 5 Amps, 240 volts, 50 Hz, switch socket outlet point on independent board complete all as specified and directed.
All as per Srl Item No. 158 here-in-before but for One 3 pin socket outlet 5 Amps, 240 volts, 50 Hz, on the same board with other switches complete all as specified and directed.
All as per Srl Item No. 158 here-in-before but for One light point controlled by two two way switches complete all as specified and directed.
All as per Srl Item No. 158 here-in-before but for One bell/buzzer point controlled by one push button on the same board with other switches or independent complete all as specified and directed.
All as per Srl Item No. 158 here-in-before but wiring with 2.5 sq.mm multistranded cable and earth wire 2.5 Sqmm with copper conductor complete all as specified and directed.
All as per Srl Item No. 158 here-in-before but wiring with 4 sq.mm multistranded cable and earth wire with copper conductor of size 4 sq.mm for Metal clad socket complete all as specified and directed.
Supply and fix Modular switch 1 way 6 A,1 module 230 Volts,50Hz, ISI marked complete all as specified and directed.
Supply and fix Socket, 6A-2/3 pin combined 2 module 230 Volts,50Hz, ISI marked complete all as specified and directed.
Supply and fix Modular bell push 6 A,1 module 230 Volts,50Hz, ISI marked complete all as specified and directed.
Supply and fix Modular switch 2 way 6 A,1 module 230 Volts,50Hz, ISI marked complete all as specified and directed.
Supply and fix Modular switch 1 way 16 A,1 module 230 Volts,50Hz, ISI marked complete all as specified and directed.
Supply and fix Socket, 6A/16A-2/3 pin combined 2 module 230 Volts,50Hz, ISI marked complete all as specified and directed.
Supply and fixing LED light fitting 1 x 18 W (4 FT), 220 V,AC, surface/ wall mounted with Aluminum housing & integrated high efficiency electronic driver with lower THD (< 15 %) , IP 20, CRI >=80, Colour Temp (CCT) - 6500 K, System lumen not less than 1980 lm. Electronic driver & surge suppressor, power factor 0.90, operating range - 140 to 270 V, 50 Hz fixed with suitable fixing arrangement complete including 01 No. 24 W (4 FT) LED lamp or strip high efficiency LEDs as per OEM with viewing angle of 120º with certification LM 79 for liminare, LM 80 for LED source including all necessary internally pre-wired and connecting up with and including twin twisted flexible copper conductor cable of suitable size ceiling rose to terminal block fixing on PVC block complete all as specified and directed.
Supply and fixing LED light fitting 1 x 20 W (4 FT),220 V, AC, surface/ wall mounted with Aluminum housing & integrated high efficiency electronic driver with lower THD (< 15 %) , IP 20, CRI >=80, Colour Temp (CCT) - 6500 K, System lumen not less than 2200 lm. Electronic driver & surge suppressor, power factor 0.90, operating range - 140 to 270 V, 50 Hz fixed with suitable fixing arrangement complete including 20 W LED strip high efficiency LEDs as per OEM with viewing angle of 120º with certification LM 79 for liminare, LM 80 for LED source including all necessary internally pre-wired and connecting up with and including twin twisted flexible copper conductor cable of suitable size eiling rose to terminal block fixing on PVC/wooden round block complete all as specified and directed.
Supply and fix of 10 Watt LED Bulk Head fitting Environmenatal friendly pressure die cast aluminium housing,IP-65, ultra morden, energy saving, surface mounted, decorative oval bulk head edge- lit LED luminaries comprising of high brightness LEDs complete all as specified and directed.
Supply & fixing LED Mirror lights light fitting with high out put diffuser 2 feet , 10 watt 220 v AC Extruded aluminium, PC Diffuser, efficiency >125 lm/ W, glare free, THD<10%,Potted electronic driver connecting up with three core flexible copper conductor cable of suitable size from ceiling rosecomplete all as specified and directed.
S&F ceiling rose 3 terminal, PVC polycarbonate, insulated body (ISI Marked) complete all as specified and directed.
Supply & fix lamp holder angular/straight insulated body, with 15 Watt LED bulb, 6500 K white/ivory finish complete all as specified and directed.
Taking down old exhaust fan and overhauling, Painting of exhaust fan including oiling and greasing of exhaust fan complete including replacement of damaged screw of blade and body and refixing to exhaust fan and testing complete size of exhaust fan 250/300 mm sweep complete all as specified and directed.
Taking down all parts of old exhaust fan and taking out old brunt copper winding of exhaust fan motor and rewinding with super quality super enamelled copper wire of existing gauge including refixing at the existing place, testing and commissioning complete for Exhaust fan 250 mm sweep complete all as specified and directed.
Taking down all parts of old exhaust fan and taking out old brunt copper winding of exhaust fan motor and rewinding with super quality super enamelled copper wire of existing gauge including refixing at the existing place, testing and commissioning complete for Exhaust fan 300 mm sweep complete all as specified and directed.
Replacement of capacitor AC 50 Hz 440 V grade of capacity 4 Mfd complete all as specified and directed.
Taking down and refixing of Geysers storage type after complition of civil work for 25/50 ltrs capacity complete with grounding/drilling in wall and Provn of Zinc coated fastner 12 mm dia 150 mm long x04 Nos including replace hot & cold PVC pipe complete including nuts/bolt, painting and checking inspection of functionality of element, thermostat, leakge of water assembly, inner tank etc complete all as specified and directed.
S&F in repairs heating element 1500 watt push/screw/triangular/square type suitable for 25 ltrs capacity geysersany make/type complete all as specified and directed.
S&F in repairs heating element 2000 watt push/screw/triangular/square type suitable for 25 ltrs capacity geysersany make/type complete all as specified and directed.
S&F in repairs Thermostat switch suitable for 25/50 ltrs capacity geysersof any make /type with temperature rangeadjustable from 25 to 90 degree centigrade heating element 2000 watt push/screw/triangular/square type suitable for 25 ltrs capacity geysersany make/type complete all as specified and directed.
Supply & fixing Buzzer Ding Dong AC 230 volts single pole with suitable fixing arrangement complete all as specified and directed.
S&F single pole & neutral SPN modular type 8 module with a two pin & earth plug & socket complete with one single pole MCB C curve of 20 A rating complete all as specified and directed
M&L for concealed sub main wiring with two (02) run of 10.0 Sq.mm (nominal area) FRLSH PVC insulated, single core, unsheathed, multistranded, copper conductor cables, 1100 Volts grade, alongwith one (01) run of 10.0 Sq.mm (nominal area) FRLSH PVC insulated, single core, unsheathed, multistranded, copper earth continuity conductor, 1100 Volts grade, drawn through and including 20 mm dia (medium grade) rigid non metallic PVC concealed conduit and accessories fixed to wall/ceiling Including cutting chases in cement mortar (1:3) to making good with the adjoining surfaces and connected to common earth dolly complete, all as specified and directed. NOTE : Two (02) runs of 10.0 Sq.mm main copper conductor cable, one (01) run of 10.0 Sq.mm copper earth continuity conduit and one run of PVC concealed conduit shall measured and paid as one unit length are included in the quoted rate.
M&L for concealed sub main wiring with two (02) run of 6.0 Sq.mm (nominal area) FRLSH PVC insulated, single core, unsheathed, multistranded, copper conductor cables, 1100 Volts grade, alongwith one (01) run of 6.0 Sq.mm (nominal area) FRLSH PVC insulated, single core, unsheathed, multistranded, copper earth continuity conductor, 1100 Volts grade, drawn through and including 20 mm dia (medium grade) rigid non metallic PVC concealed conduit and accessories fixed to wall/ceiling Including cutting chases in cement mortar (1:3) to making good with the adjoining surfaces and connected to common earth dolly complete, all as specified and directed. NOTE : Two (02) runs of 6.0 Sq.mm main copper conductor cable, one (01) run of 6.0 Sq.mm copper earth continuity conduit and one run of PVC concealed conduit shall measured and paid as one unit length are included in the quoted rate.
S&F for MCB DB TPN 4 ways Double Door 240 Volt with rated bus bar ,IP-42, IK-09, metal door, earth bar, neutral links complete including blanking plates as required & fixed flush to wall / other surface complete all as specified and directed.
S&F for MCB DB SPN 4 ways single Door 240 Volt with 200 Amp rated bus bar ,IP-42, IK-09, metal door, earth bar, neutral links complete incl blanking plates as required & fixed flush to wall / other surface complete all as specified and directed.
S&F for MCB DB SPN 8 ways Double Door 240 Volt with rated bus bar ,IP-42, IK-09, metal door, earth bar, neutral links complete incl blanking plates as required & fixed flush to wall / other surface complete all as specified and directed.
S&F for MCB DB SPN 12 ways Double Door 240 Volt with 200 Amp rated bus bar ,IP-42, IK-09, metal door, earth bar, neutral links complete incl blanking plates as required & fixed flush to wall / other surface complete all as specified and directed.
S&F MCB 4 Pole 63 to 100 Amps , 415 Volts , 10 KA rupturing capacity, C curve complete all as specified and directed.
S&F MCB single pole & neutral SPN 40 to 63 Amps , 240 Volts , 10 KA rupturing capacity , C curve complete all as specified and directed.
S&F MCB single pole & neutral SPN 06 to 32 Amps , 240 Volts , 10 KA rupturing capacity , C curve complete all as specified and directed.
S&F MCB single pole 6 to 32 Amps , 240 Volts , 10 KA rupturing capacity , C curve complete all as specified and directed.
M&L for concealed sub main wiring with two (02) run of 1.50 Sq.mm (nominal area) FRLSH PVC insulated, single core, unsheathed, multistranded, copper conductor cables, 1100 Volts grade, alongwith one (01) run of 1.50 Sq.mm (nominal area) FRLSH PVC insulated, single core, unsheathed, multistranded, copper earth continuity conductor, 1100 Volts grade, drawn through and including 15 mm dia (medium grade) rigid non metallic PVC concealed conduit and accessories fixed to wall/ceiling Including cutting chases in cement mortar (1:3) to making good with the adjoining surfaces and connected to common earth dolly complete, all as specified and directed. NOTE : Two (02) runs of 1.50 Sq.mm main copper conductor cable, one (01) run of 1.50 Sq.mm copper earth continuity conduit and one run of PVC concealed conduit shall measured and paid as one unit length are included in the quoted rate.
Supply, laying ,jointing and testing in trenches or passing through pipe, 1100 Volts grade XLPE insulated, armoured heavy duty electric cable with aluminium conductor of cross sectional area 6 Sqmm 2 core with necessary fixing arrangements such as lugs, glands and terminal etc complete all as specified and directed.
Supply and fixing LED building light fitting 35 watt 230 V, AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP65 /66 protection and impact resistance of IK07 complete GI Pipe Bracket 1.5m long made out of GI Pipe 40 mm dia light grade suitable for fixing street lights bend to suitable radius incl 2 sets of clamps nuts bolts washers incl painting with aluminium paint etc complete all as specified and directed.
Supply, fixing and commissioning and Design verified as per IS /IEC-61439-1&2 LT Panel, indoor type LT Panel / LT feeder Pillar Box by CPRI Approved manufacturers with comprising of the following and all as directed by removing the old existing panel complete with out damaging the existing floor / cable ducts at secondary sub station complete all as specified and directed. Fabrication Details : Main frame 3 mm thick CRCA sheet, partition sheets / covers / doors of 2 mm thick CRCA sheet, gland plates 2 mm thick MS sheet (undrilled), base frame of 75 mm MS channel with provision of incoming and outgoing cable entry at the bottom for installation, seperate chambers for Main Bus Bars, switch Gears and Cable end connections free standing floor mounted with degree of protection IP 54 and with heavy duty Hinges for doors and locking arrangements with Aldrops at front and Back complete all as specified and directed. Bus bar details : Material shall be Copper bus bar, sleeving heat shrinkable type, with bus bar sizes for phase of rated capacity and bus bar shall extended type be support of epoxy type insulators for connection, earthing of 40x6 mm GI Flat complete all as specified and directed. Painting Detais : Painting shall be 7 tank processed powder coated shall be a dry finishing process that uses finely ground particles of pigment and resin based polymer that are electrostatically charged and sprayed onto electrically grounded parts complete all as specified and directed. Wiring : Pannel wiring shall be of 2.5 sq mm copper standard with 5A MCB wiring for controll wiring and indication lamps complete all as specified and directed. Accessories for Pillar Box : Digital Multifunctional Meters CT/PT programmable with RS 485 communicatio port CL 0.5 with direct acess to basic power and Energy parameters and Indication Lamps (LED) - 03 No. make: L&T or equivalent in Secure /Elmeasure complete all as specified and directed. Item continued as Srl No. 202.00
Incoming complete all as specified and directed; Switch Gear (a) MCCB 100 Amps rating 415 Volts ,4 pole ,25 kA (Ics=100%icu) with adjustable thermal & magnetic release (80-100%) & earth fault protection-01 Nos (b) indicating lamp RYB -01 Set (Set of three) (d) Space for 04 Electric Meter Outgoing complete all as specified and directed. (a)SPN 63 Amps 10 kA -04Nos (b)SP 32 Amp10 kA-01 Nos NOTE : Rate quoted includes for necessary PCC foundation / steel angulars/ channels to LT pannel and includes the cost of all Accessories and switch gears, necessary cable connections with Lugs, washers nut bolts and cable glands as per site requirement complete all as specified and directed.
Supply, fixing and commissioning and Design verified as per IS /IEC-61439-1&2 LT Panel, indoor type LT Panel / LT feeder Pillar Box by CPRI Approved manufacturers with comprising of the following and all as directed by removing the old existing panel complete with out damaging the existing floor / cable ducts at secondary sub station complete all as specified and directed. Fabrication Details : Main frame 3 mm thick CRCA sheet, partition sheets / covers / doors of 2 mm thick CRCA sheet, gland plates 2 mm thick MS sheet (undrilled), base frame of 75 mm MS channel with provision of incoming and outgoing cable entry at the bottom for installation, seperate chambers for Main Bus Bars, switch Gears and Cable end connections free standing floor mounted with degree of protection IP 54 and with heavy duty Hinges for doors and locking arrangements with Aldrops at front and Back complete all as specified and directed. Bus bar details : Material shall be Copper bus bar, sleeving heat shrinkable type, with bus bar sizes for phase of rated capacity and bus bar shall extended type be support of epoxy type insulators for connection , earthing of 40x6 mm GI Flat complete all as specified and directed. Painting Detais : Painting shall be 7 tank processed powder coated shall be a dry finishing process that uses finely ground particles of pigment and resin based polymer that are electrostatically charged and sprayed onto electrically grounded parts Wiring : Pannel wiring shall be of 2.5 sq mm copper standard with 5A MCB wiring for controll wiring and indication lamps Accessories for Pillar Box : Digital Multifunctional Meters CT/PT programmable with RS 485 communicatio port CL 0.5 with direct acess to basic power and Energy parameters and Indication Lamps (LED) - 03 No. make: L&T or equivalent in Secure /Elmeasure complete all as specified and directed. Item continued as Srl No. 204.00
Incoming complete all as specified and directed; Switch Gear : (a) MCCB 125 Amps rating 415 Volts ,4 pole ,25 kA (Ics=100%icu) with adjustable thermal & magnetic release (80-100%) & earth fault protection-01 Nos (b) indicating lamp RYB -01 Set (Set of three) (c) digital Ammeter and voltmeter (d) Space for 04 Electric Meter Outgoing complete all as specified and directed. (a) SPN 63 Amps 10 kA -04Nos (b) SP 32 Amp10 kA-01 Nos NOTE : Rate quoted includes for necessary PCC foundation / steel angulars/ channels to LT pannel and includes the cost of all Accessories and switch gears, necessary cable connections with Lugs, washers nut bolts and cable glands as per site requirement complete all as specified and directed.
Supply, fixing and commissioning and Design verified as per IS /IEC-61439-1&2 LT Panel, indoor type LT Panel / LT feeder Pillar Box by CPRI Approved manufacturers with comprising of the following and all as directed by removing the old existing panel complete with out damaging the existing floor / cable ducts at secondary sub station complete all as specified and directed. Fabrication Details : Main frame 3 mm thick CRCA sheet, partition sheets / covers / doors of 2 mm thick CRCA sheet, gland plates 2 mm thick MS sheet (undrilled), base frame of 75 mm MS channel with provision of incoming and outgoing cable entry at the bottom for installation, seperate chambers for Main Bus Bars, switch Gears and Cable end connections free standing floor mounted with degree of protection IP 54 and with heavy duty Hinges for doors and locking arrangements with Aldrops at front and Back complete all as specified and directed. Bus bar details : Material shall be Copper bus bar, sleeving heat shrinkable type, with bus bar sizes for phase of rated capacity and bus bar shall extended type be support of epoxy type insulators for connection , earthing of 40x6 mm GI Flat complete all as specified and directed. Painting Detais : Painting shall be 7 tank processed powder coated shall be a dry finishing process that uses finely ground particles of pigment and resin based polymer that are electrostatically charged and sprayed onto electrically grounded parts complete all as specified and directed. Wiring : Pannel wiring shall be of 2.5 sq mm copper standard with 5A MCB wiring for controll wiring and indication lamps complete all as specified and directed. Accessories for Pillar Box : Digital Multifunctional Meters CT/PT programmable with RS 485 communicatio port CL 0.5 with direct acess to basic power and Energy parameters and Indication Lamps (LED) - 03 No. make: L&T or equivalent in Secure /Elmeasure complete all as specified and directed. Item continued as Srl No. 206.00
Incoming complete all as specified and directed; Switch Gear (a)MCCB 160 Amps rating 415 Volts ,4 pole ,36 kA (Ics=100%icu) with adjustable thermal & magnetic release (80-100%) & earth fault protection-01 Nos complete all as specified and directed. (b) indicating lamp RYB -01 Set (Set of three) (d) Space for 06 Electric Meter Outgoing complete all as specified and directed. (a)SPN 63 Amps 10 kA -04Nos (b)SP 32 Amp10 kA-01 Nos NOTE : Rate quoted includes for necessary PCC foundation / steel angulars/ channels to LT pannel and includes the cost of all Accessories and switch gears, necessary cable connections with Lugs, washers nut bolts and cable glands as per site requirement complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5mtrs below normal ground level connected with galvanised iron/steel earth wire of 4 mm dia by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part-I and earth wire protected by galvanized pipe medium grade 15mm bore and connected to DBs including necessary earthwork and excavation in any type of soil, GI medium grade 20mm bore watering pipe with funnel and wire mesh, PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type B1 design mix cover slab with 6mm dia MS bars at 100mm c/c both ways with MS Hook 6mm dia MS bars etc with earthing test point complete all as specified and directed.
Supply and laying DWC pipe SN-4 with coupler 40mm OD, ISI marked along with all accessories like socket, bend, couplers etc. Conforming to IS 14930, PartII complete with fitting and cutting , jointing etc. Laid in trenches/fixed to pole /laying under road crossing /fixed on pavement wall with clamps complete all as specified and directed.
S&F Boxes junction, plastic, round, four terminals (ISI Marked) complete all as specified and directed.
External Water Supply Taking out old existing water tank 500 Ltrs capacity any type complete all as specified and directed.
Taking out old GI Tubing 20/25 mm with with Gun metal valve of any type complete all as specified and directed.
Supply & Fixing rotational moulded polythene water storage tank 500 Ltrs capacity, ISI marked multi 3 layer construction with threaded cap on top (cylindrical vertical with closed top) hoisted & fixed in the same position etc complete all as specified and directed.
Disconnecting existing water tanks 500 Ltrs capacity and refixing in the same position including cleaning and removing all scale and dirt etc from mouths of circulating pipes etc complete all as specified and directed.
supply and fixing of 20mm bore ball valves , high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of having weight not less than 210 gms including connection complete all as specified and directed.
M&L for 25mm bore steel tubing medium grade galvanised with all fitting fixed complete to walls and ceiling or floor complete all as specified and as directed
M&L for 20mm bore steel tubing medium grade galvanised with all fitting fixed complete to walls and ceiling or floor complete all as specified and directed.
Supply & fix 25 mm bore Gun metal valves, ISI marked with iron wheel head screwed both ends for GI pipe complete all as specified and directed
Supply & fix 20 mm bore Gun metal valves, ISI marked with iron wheel head screwed both ends for GI pipe complete all as specified and directed.
M/S R. K. INDUSTRIES (BID ID -3119653)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
BOQ_747669.xls
BOQ Document • 0.43 MB
Complete_Tender_Except_BOQ.pdf
BOQ Document • 1.96 MB
151341972.pdf
Tender Document • 0.20 MB
151341975.html
Tender Document • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .