| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹31.0 LAccepted-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | 1 | Accepted-AOC Lowest | |
| 2 | 2₹32.0 L+₹55,820 (1.78%)Rejected-Finance | 2 | Rejected-Finance Higher | |
| 3 | 3₹32.7 L+₹1.2 L (3.90%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | 3 | Rejected-Finance Higher | |
| 4 | 4₹36.4 L+₹5.0 L (15.9%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | 4 | Rejected-Finance Higher | |
| 5 | 5₹45.8 L+₹14.3 L (45.6%)Rejected-Finance 1ST FLOOR RAGHUNATH MARKET NEAR TELEPHONE EXCHANGE PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | 5 | Rejected-Finance Higher |
Tender Value
₹36 L
Closing Date
28 Feb 2022, 3:00 pmClosed
GE Amritsar
GE Amritsar PIN-143001
PROVN OF STREET LIGHTS WITH POLE AND ALLIED WORKS AND SPL REPAIR OF LT CABLE, PANELS AND DISTRIBUTION BOXES AT OLD AMRITSAR CANTT
2022_MES_504792_1
GE/ASR-48/2021-22
Open Tender
Civil Works
Item Rate
120 days
GE Amritsar
Class D, category bi
8 documents required · 8 mandatory
₹500
GE Amritsar
Exempted
1 Apr 2022
31 Jan 2022
1 Mar 2022
31 Jan 2022
28 Feb 2022
14 Feb 2022
Amount
Supply, transporting, erecting and truly fixed in vertical position and fixing of steel tubular pole swaged, over all length 9 metres, type 410 – SP – 31 complete with mild steel base plate, pole cap, finial taper plug, MS bolts, nuts & washers, and painting of pole with two coats of anti corrosive black bituminous paint through out internally and externally upto planting depth (embedded in concrete) and including painting of exposed surfaces of Pole (Full length of pole) with two coats of aluminium paint over a coat of red oxide primer, and painting of 05 Nos. bands / strips of 30 cm wide each with two coats of synthetic enamel paint (black & yellow) at a distance of 30 cm from plinth block upto 1500 mm height and marking / sign writing of pole number and feeders locations of pole with thick synthetic enamel paint (white) complete all as specified and directed by the Engineer-in-Charge. Note : PCC and earth work, MS bracket for fixing light fitting shall be meassured and paid separately under respective items of BOQ.
Supply & fixing for 90 watt LED light fitting made of pressure die cast aluminium alloy for housing heat sink for effective thermal management studyness excellent corrosion resistance cable gland is used for maintaining ingressprotection epoxy powder coated grey colour finish after phosphochromate treatment, tempered protective toughened glass, thermal shock and impact resistance fixed to the housing with SS screws. High efficacy long life LED module with the SMD LED package mounted on MCPCB with lumen efficacy of LED >140 lumen/Watt with PC lens to ensure better uniformity of light distribution, ambient temperature 35 degree celcius .and system lumen 9000 for above. Power by built in isolated electronic driver SMPS base constant current supply with lower THD, output open slash short circuit protection , Over voltage protection , Phase to phase protection , surge voltage protection 10 KVA. with IK 07 and IP 66 protection, CCT 5700K CRI more than 70 THD<10%, SPD 10 KVA for internal and external 10 KVA extra should be fixed with fitting, PF> 0.95 IP66 IK07 protection with life of 50000Hrs @ L70 operating temp -10 degree to +50 degree input supply voltage range 140/270V frequency 50/60Hz . Driver safety requirement standard: IS 15885/2/13, driver performance requirement IS 16104. Photobiological safety norms IS 16108. Certification LM 79 for luminar LM 80 for LED. And warranty should be 5 Years on site. Note :- Contractor shall produce the Genuineness and warranty certificate from the manufacturer before fixing. 2. Contractor will arrange /provide suitable ladder (Telescopic/Hydra) with technicians for fixing of street lights from statrting of contract upto date of completion of the work.
Supply, Laying, Testing and Commissioning of LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables 16 Sqmm 04 core (heavy duty) 1100 Volts grade with stranded Aluminium conductor complete all as specified by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 metres wide and not exceeding 1.5 metres in depth for foundation/cable trench/laying of pipe line/taking out pipe etc and getting out in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Returning, filling in including spreading, levelling, watering and well ramming in layer not exceeding 25 cm in any type of soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil to a distance not exceeding 50 metres and deposing where directed at a level not exceeding 1.5 metres above the starting point complete all as specified and directed by Engineer-in-charge.
Supply and filling dry, clean sand in trenches for cushioning of underground cable including punning down complete all as specified and directed. Note:- Only Punned down thickness shall be maesured and paid
Supply and laying burnt brick sub class 'B' modular size, for cable protection laid length wise perpendicular to the axis of cable complete all as specified and directed.
Supply & fixing in repairs GI pipe bracket, made out of 40mm dia light grade GI pipe, fabricated into shape and size as required, not less than 1.2 metre long complete with two MS clamps of MS flat iron 40mm x 6mm with bolts, nuts and washer complete all fixed on poles/walls complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing for thermoplastic polycarbonate cable junction box hinged door type of size 200mm x 160mm x 90mm for 3Phase and N incoming cable 3 Phase and N outgoing cable and single Pole and N connection for light fitting with terminal block with cage and clamp system (screw less) shock proof sage IP-65 weather proof rust dust and water proof internally embeded gasket with provn for cable entry through gland along with MS clamp and mounting brackets as required at site complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing for PVC insulated PVC Sheathed multi stranded copper conductor wire 1.5 sqmm size twin core complete for drawing through pole for making connection to street light fitting provided on poles upto junction box including thimbles complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing for 50mm GI pipe of light grade including cutting in pieces for fixing with pole including suitable size clamps fixed on poles/walls complete all as specified & directed by the Engineer-in-Charge.
Material & Labour for cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate ) as in foundation for poles, mass concrete, pedestal/coping, including necessary weathering , chamfering , surfaces finished even & fair including necessary form work complete all as specified & directed by the Engineer-in-Charge.
Material & Labour for cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate ) as in foundation for poles, mass concrete, pedestal/coping, including necessary weathering , chamfering , surfaces finished even & fair including necessary form work complete all as specified & directed by the Engineer-in-Charge.
Material & Labour for cement concrete 1:2:4 type B-2 (using 40 mm graded stone aggregate ) as in coping for poles, mass concrete, pedestal/coping, including necessary weathering , chamfering , surfaces finished even & fair including necessary form work complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing for street light distribution outdoor panel of size not less than 600mm x 400mm x 200mm with canopy single door vertical type made out of CRCA MS sheet with thickness not less than 3 mm surface with insulated material like polysofer or with epoxy powder coating surface mounting TPN 4 way,415 Volt with copper bus bar rating 200Amps for R,Y,B,N phases dust and vermin proof suitable for incorporation of MCCB and IP43-IK09 profection with and including MCCB 100Amps 16KA 4 Pole and including angle iron support legs and height of the legs shall be atleast 300mm above ground level made of angle iron for support 45 mm x 45mm x 6mm thick, with & including necessary Excavation & Earth work , PCC 1:2:4 in foundation of legs of panel, form work etc.complete all as specified & directed by the Engineer-in-Charge.
Supply, installation and testing, automatic street lighting time switch unit for three phase application complete with & including contractor FP 63 Amps - 4 Nos, 230V AC, MCB DX3 FP C63A AC MCB and DB SPN 12 way IP 54-IK 09), the time switch should calculate sunrise and sunset by programming date, time and local coordinates and should have text based programming concept with running reverse of 6 Years for date & time automatic summer / winter time change with precision 0.2 Sec / day complete all as specified & directed by the Engineer-in-Charge.
Material and labour for earthing complete with galvanised earth plate electrode 600mm X 600mm X 6 mm thick burried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised earth strip 32 X 6 mm size by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part – I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate), duly reinforced with 6 mm dia mild steel round bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate), GI protection pipe light grade 40 mm bore up to 7.5 m length from earth electrode & engraving of earth marking on nearby building with CM 1:4 plate size 200 X 150 X 15 mm & painting of earth result etc. including testing on complete all as specified and directed. Note :-Testing of earthing before completion of work shall be carried out by the contractor in the presence of Engineer in Charge. If desired earth resistance is not obtained, the earthing shall be redone by the contractor without any extra cost to govt.
Supply, fixing , installation, commissioning and testing CPRI approved factory made LT feeder pillar box , double door, outdoor ,FRONT & REAR OPENABLE type totally enclosed free pedestal mounting dust and vermin proof, weather proof made out of 1.65 mm thick stainless steel sheet , 304 grade duly powder coated using 7 tank process as per IS: 8623 rated for short circuit rating of 50 KA , base frame made of angle iron of size 50mm x 50mm x 5mm, with stainless steel hinge , slider door locks(front & rear ) , door handles (front&rear) suitable for 415 Volts, 3 phase, 4 wire, 50 Hz, AC supply outdoor type complete with and including incoming and outgoing moulded case circuit breakers, aluminium bus bar including internal wiring with not less than PVC insulated unsheathed 2.5 Sqmm multi stranded copper conductor cable, bonding to earth interconnection, and including dismantling & taking down the old unserviceable Panel,& Minimum Outer dimension of panel shall be i.e. width = 2 metres , Depth = 0.90 metres and Height = 2.0 metres complete all as specified & directed with & including following :- Incoming (a) MCCB 400 Amp, 4 pole, 36 KA,Microprocessor based,Icu = Ics = Icw 415 volt, 50 Hz - 01 Nos Outgoing (a) MCCB 250 Amp, 4pole, 25 KA,Microprocessor based, Icu = Ics = Icw415 volt, 50 Hz MCCB - 02 Nos (b) MCCB 160 Amp, 4pole, 25 KA,Microprocessor based, Icu = Ics = Icw415 volt, 50 Hz MCCB - 02 Nos (c) Aluminium BUS BAR SUITABLE FOR 600 A ,SIZE 80mm*10mm (R Y B N) COVERED WITH HEAT SHRINKABLE COLOUR CODED SLEEVES (d) Digital LCD MULTIFUNCTIONAL METER,Class. 1 .0 ACCURACY DISPLAYING VOLTAGE ,CURRENT of all type of phase ,FREQUENCY complete with 3 CTs of suitable size -01 No (e) L E D indicating lamps (R, Y & B) PROTECTED WITH 2A SP MCB'S - 01 set of three lamps, Make of LED indicating lamps and MCB (f) EARTHING STRIP OF SIZE 25mm*5mm OF ALUMINIUM RUNNING THROUGHOUT THE LENGTH OF THE SUBJECT L T PANEL
Supply, fixing , installation, commissioning and testing CPRI approved factory made LT feeder pillar box , double door, outdoor ,FRONT& REAR OPENABLE type totally enclosed free pedestal mounting dust and vermin proof, weather proof made out of 1.65 mm thick stainless steel sheet , 304 grade duly powder coated using 7 tank process as per IS: 8623 rated for short circuit rating of 36 KA ,base frame of 50mm x 50mm x 5mm,with hinges of stainless steel,slider door locks(front &rear ) ,door handles (front&rear) suitable for 415 Volts, 3 phase, 4 wire, 50 Hz, AC supply outdoor type complete with and including incoming and outgoing moulded case circuit breakers, aluminium bus bar including internal wiring with not less than PVC insulated unsheathed 2.5 Sqmm multi stranded copper conductor cable, bonding to earth interconnection complete as required and as approved from CPRI Minimum, and including dismantling & taking down the old unserviceable Panel, & minimum Outer dimension of panel shall be i.e. width = 1.5metres , Depth = 0.50 metres and Height = 1.5metres complete all as specified & directed with & including following, :- Incoming (a) MCCB 250 Amp, 4pole, 36 KA,Microprocessor based,Icu = Ics = Icw 415 volt, 50 Hz MCCB - 01 Nos (b) Change over switch 4 pole offline 250 Amp Cap including connection 415 volts - 1 nos Out going (a) MCCB 200 Amp, 4pole, 36 KA,Microprocessor based,Icu = Ics = Icw 415 volt, 50 Hz MCCB - 02 Nos (b) MCCB 160 Amp, 4pole, 25 KA,Microprocessor based, Icu = Ics = Icw415 volt, 50 Hz MCCB - 02 Nos (b) MCCB 100 Amp, 4pole, 25 KA,Microprocessor based, Icu = Ics = Icw415 volt, 50 Hz MCCB - 01 Nos (c) Aluminium BUS BAR SUITABLE FOR 400 A ,SIZE 40mm*10mm (R Y B N) COVERED WITH HEAT SHRINKABLE COLOUR CODED SLEEVES (d) Digital LCD MULTIFUNCTIONAL METER,Class. 1 .0 ACCURACY DISPLAYING VOLTAGE ,CURRENT of all type of phase ,FREQUENCY complete with 3 CTs of suitable size -01 No (e) L E D indicating lamps (R, Y & B) PROTECTED WITH 2A SP MCB'S - 01 set of three lamps, Make of LED indicating lamps and MCB - Legrand/Schneider/Siemens (f) EARTHING STRIP OF SIZE 25mm*5mm OF ALUMINIUM RUNNING THROUGHOUT THE LENGTH OF THE SUBJECT L T PANEL
Supply & Fixing Bus bar enclosure of minimum size 800mm x 600mm x 200mm made out of 1.65 mm thick stainless steel sheet , 304 grade duly powder coated using 7 tank process with and including 250 amp, 25 kA MCCB 4 pole, thermal magnetic based fitted in bus bar enclosure using 250 Amp rated bus bar, 25x10mm aluminium and RYB indication lamps duly protected by 2A SP MCB outdoor type welded to suitable size MS angle iron frame and embedded in PCC 1:2:4 type B-1 including dismantling & taking down the old unserviceable enclosure, the enclouser shall be minimum 500mm above the ground level , complete all as specified and directed by the Engineer in Charge. Note for Item No 19 to 21 :- Factory inspection will be carried out by the rep of the Accepting Officer before dispatch of the panels, Contractor shall make necessary arrangements for the visit of the representative of the Accepting officer and shall inform in advance to AO for the factory inspection.
Material and labour for earthing complete with galvanised earth plate electrode 600mm X 600mm X 6 mm thick burried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised earth strip 25 X 4 mm size by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part – I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate), duly reinforced with 6 mm dia mild steel round bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate), GI protection pipe light grade 40 mm bore up to 7.5 m length from earth electrode & engraving of earth marking on nearby building with CM 1:4 plate size 200 X 150 X 15 mm & painting of earth result etc. including testing on complete all as specified and directed. Note :-Testing of earthing before completion of work shall be carried out by the contractor in the presence of Engineer in Charge. If desired earth resistance is not obtained, the earthing shall be redone by the contractor without any extra cost to govt.
Supply, Laying, Testing and Commissioning of LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables 120 Sqmm 3.5 core (heavy duty) 1100 Volts grade with stranded Aluminium conductor including dismantling and taking down old unserviceable cable complete all as specified and directed by the Engineer in Charge.
Supply, Laying, Testing and Commissioning of LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables 95 Sqmm 3.5 core (heavy duty) 1100 Volts grade with stranded Aluminium conductor including dismantling and taking down old unserviceable cable complete all as specified and directed by the Engineer in Charge.
Supply, Laying, Testing and Commissioning of LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables 70 Sqmm 3.5 core (heavy duty) 1100 Volts grade with stranded Aluminium conductor including dismantling and taking down old unserviceable cable complete all as specified and directed by the Engineer in Charge.
Supply, Laying, Testing and Commissioning of LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables 50 Sqmm 3.5 core (heavy duty) 1100 Volts grade with stranded Aluminium conductor including dismantling and taking down old unserviceable cable complete all as specified and directed by the Engineer in Charge.
Supply, Laying, Testing and Commissioning of LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables 35 Sqmm 3.5 core (heavy duty) 1100 Volts grade with stranded Aluminium conductor including dismantling and taking down old unserviceable cable complete all as specified and directed by the Engineer in Charge.
Supply and fixing 1100 volts grade heavy duty cable 10 sqmm 2 core PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended with including PVC conduit /flexible conduit for fixing in wall/ floor /pole and making connection , including dismantling and taking down old unserviceable cable complete all as specified and directed by the Engineer in Charge.
Supply and fixing for 80 mm bore light grade galvanised iron tubing with all necessary GI fittings as in protection pipe of cable, fixed to pole or laid under floor / ground / under road crossings for protection of cable, including dismantling and taking down old unserviceable pipe complete all as specified and directed by the Engineer in Charge.
Supply and fixing for 50 mm bore light grade galvanised iron tubing with all necessary GI fittings as in protection pipe of cable, fixed to pole or laid under floor / ground / under road crossings for protection of cable including dismantling and taking down old unserviceable pipe complete all as specified and directed by the Engineer in Charge.
Material and labour for boring hole under road/path/floor etc for laying of XLPE cables any size and type with mannual labour or by mechanically complete all as specified and directed by the Engineer-in-Charge.
Material and labour for 10mm thick cement plaster in cement mortar (1:4) on fair faces of brick or concrete surfaces and finishing the surface even and smooth without using extra cement complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing for MCCB Incomer distribution board double door vertical type made out of CRCA MS sheet surface with insulated material like polyester or with epoxy powder coating surface mounting TPN 4 way, 415 volts with copper bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCCB and IP 43 - IK 09 protection with and including one nos 100Amps 36 kA 4 pole MCCB with thermal - magnetic setting and Icu = Ics = 100%, also including Suitable type MCB with blank plate, with & including taking down the old unserviceable DBs and making good of surface as original specification by brick work, plastering, whitewash/colour/distemper etc including dismantling and taking down old unserviceable DB complete all as specified and directed by the Engineer in Charge.
Supply & Fixing for flexiible conduit 50 mm dia including connection complete all as specified and directed by the Engineer in Charge.
Supply & Fixing for sheet metal enclosure for DB’s (Double door type) when MCB’s to be used, single pole and neutral, 8 ways with 200 ampere rated bus bar, 240 volts fixed sunk / flush to the wall with IP-43 and IK-09 protection ccomplete all as specified and directed by the Engineer in Charge.
Supply & Fixing for MCB single pole, 240 volts, 6 to 32 Ampere, rupturing capacity 10 KA, ‘C’ curve type, including dismantling and taking down old unserviceable MCB complete all as specified and directed by the Engineer in Charge.
Supply & Fixing for MCB double pole, 240 volts, 40 to 63 Ampere, rupturing capacity 10 KA, ‘C’ curve type including dismantling and taking down old unserviceable MCB complete all as specified and directed by the Engineer in Charge.
Material & Labour for disconnecting, dismantling and taking down existing serviceable transformer , and Shifting of transformer of capacity up to 315 kVA from one place to other place on two/four pole/plinth in old Amritsar cantt area/GG fort including removing,placing over structure reconnerting and refixing of HT/LT connections and amke it functional to the entitre satisfaction of Engineer in Charge. Note :- All type of T& P, hydra crane etc required for the job should be provided by contractor, the quoted rate of this item deemed to include the rate quoted for this item )
Supply & Fixing for KWH , AC 3 phase LT CT operated electronic energy meter with accuracy class of 1.0.3 x 240 volts 50 Hz with backlit LCD display, Electronic card , optical port of rating - 5 Amp capable of mearsuring KWH , and electrically connection and testing complete all as specified and directed by the Engineer in Charge.
Supply & Fixing for PVC sintex box of size 300mm x 200mm for fixing of meter complete all as specified and directed by the Engineer in Charge.
Material & labour for PVC coated galvanized iron chain link fencing, made of GI wire dia not less than 3 mm, and minimum dia 4.5 mm after PVC coating, having any mesh size (mesh size as approved by GE) including line wire, any type of standards, rails, straining bolts, etc including provission of binding wire, fixed as knuckled type for around transformer / 4 pole structure complete all as specified and directed by the Engineer in Charge.
GULSHAN SINGH GHAI AND SON
Raman Electric Trading Co
R D Bansal
JCC ENGINEERS PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .