Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.8 LAccepted-AOC 02 PADRI SHIV NAGAR SHIV NAGAR MAHARAJGANJ UTTAR PRADESH 273303 | MAHARAJGANJ | UTTAR PRADESH | 273303 | L1 | Accepted-AOC Being overall rate reasonable | |
| 2 | L2₹33.8 L+₹2.0 L (6.13%)Rejected-Finance PLOT NO 8 PREMA APARTMENT VEDANTNAGAR CHHATRAPATI SAMBHAJINAGAR 431 007 M S | CHHATRAPATI SAMBHAJINAGAR | CHHATRAPATI SAMBHAJINAGAR | MAHARASHTRA | 431007 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹34.5 L+₹2.6 L (8.16%)Rejected-Finance GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹35.6 L+₹3.7 L (11.7%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹41.2 L+₹9.3 L (29.2%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
6 Dec 2021, 6:00 pmClosed
GE (CENTRAL) KIRKEE
GE (CENTRAL) KIRKEE, RANGE HILLS RAOD KIRKEE PUNE-411003
REPAIR MAINT OF INTERNAL WIRING AND ACCESSORIES GEYSERS, FAN ETC OF MD AND OTM ACCN OF OFFRS JCO AND OR AT BEG AND CENTRE DEPOT BN AND OTHER UNITS AT BEG AND CENTRE UNDER AGE EMI IN GE (C) KIRKEE
2021_MES_487087_1
8547/E8 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE (CENTRAL) KIRKEE
₹96,000
Yes
19 Jan 2022
9 Nov 2021
7 Dec 2021
9 Nov 2021
6 Dec 2021
24 Nov 2021
9 Nov 2021 - 23 Nov 2021
Amount
Material & Labour for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one light point or one fan point or one call bell point controlled by one, one way switch including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, regulators or bell push and casing caping terminal box for mounting ceiling rose/ holders etc incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces complete all as specified and directed by Engineer in Charge.
All as per item no 1 above but for one 5 Amp socket point on independent board complete all as specified and as directed by Engineer in Charge.
All as per item no 1 above but for one 5 Amp socket point on same board complete all as specified and as directed by Engineer in Charge.
All as per item no 1 above but for one two way light point controlled by two, two way switch complete all as specified and as directed by Engineer in Charge.
Material & Labour for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm as earth lead and connected to earth dolly for one 16 Amp socket (Power) point on independent board including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, regulators or bell push and casing caping terminal box for mounting ceiling rose/ holders etc incl dismantling taking down old unserviceable point wiring and making good to disturbed surfaces complete all as specified and directed by Engineer in Charge.
Material & Labour for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces complete all as specified and directed by Engineer in Charge. NOTE: (a)Two run of cable with one run of earth wire and one run of casing caping/conduit shall be measured as one length.
Material & Labour for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces complete all as specified and directed by Engineer in Charge. NOTE: (a)Two run of cable with one run of earth wire and one run of casing caping/conduit shall be measured as one length.
Material & Labour for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4.0 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces complete all as specified and directed by Engineer in Charge. NOTE: (a)Two run of cable with one run of earth wire and one run of casing caping/conduit shall be measured as one length.
Material & Labour for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces complete all as specified and directed by Engineer in Charge. NOTE: (a)Two run of cable with one run of earth wire and one run of casing caping/conduit shall be measured as one length.
Material & Labour for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 10.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 10.0 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces complete all as specified and directed by Engineer in Charge. NOTE: (a)Two run of cable with one run of earth wire and one run of casing caping/conduit shall be measured as one length.
Supply & Fix 5 Amp switch piano type, single pole, one way including dismantling and taking down unsv one complete all as specified and as directed by Engineer in Charge.
Supply & Fix 5 Amp switch piano type, single pole, two way including dismantling and taking down unsv one complete all as specified and as directed by Engineer in Charge.
Supply & Fix bell push piano type one way 240 volt including dismantling taking down unsv one complete all as specified and as directed by Engineer in Charge.
Supply & Fix socket flush type 6 Amps, 5 pin, 230v including dismantling, taking down unsv one complete all as specified and as directed by Engineer in Charge.
Supply & Fix switch socket combination multipurpose 2-in-1 flush type, 3 pin, 6 amps, 230v including dismantling, taking down unsv one complete all as specified and as directed by Engineer in Charge.
Supply & Fix switch socket combination multipurpose 2-in-1 flush type, 3 pin 16 amps and 3 pin 6 amps, 230v including dismantling, taking down unsv one complete all as specified and as directed by Engineer in Charge.
Supply & Fix lamp Holder insulated body with back plate for batten fitting including dismantling, taking down unsv one complete all as specified and as directed by Engineer in Charge.
Supply & Fix LED lamp 12 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min) including dismantling, taking out unsv CFL complete all as specified and as directed by Engineer in Charge. Make:-CG or equivalent from list of make as approved by GE.
Supply & Fix LED lamp 3/7 watt, CDL, E-27 230V, PF-0.95 (min) including dismantling, taking out unsv CFL complete all as specified and as directed by Engineer in Charge. Make:-CG or equivalent from list of make as approved by GE.
Supply & Fix Ceiling rose surface Bakelite, three terminal including dismantling, taking down unsv complete all as specified and as directed by Engineer in Charge.
Supply & Fix Call bell electric, ding dong, AC 240 volt, 50 HZ. including dismantling, taking down unsv one complete all as specified and as directed by Engineer in Charge.
Supply & Fix flush type electronic fan regulator with 5 step type,120 W, AC 240 Volts, 50 Hz including dismantling, taking down unsv one complete all as specified and as directed by Engineer in Charge.
Supply & Fix MCB, Single Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve including dismantling, taking down unsv one complete all as specified and directed by Engineer in Charge. MAKE- Cat Part No- 4085-87 to 4085-95 of Legrand or equivalent from list of make as approved by GE.
Supply & Fix MCB, Double Pole, 6 to 32 amps, 415 Volts, 10 KA breaking cap, ‘’C” curve including dismantling, taking down unsv one all as specified and directed by Engineer in Charge. MAKE- Cat Part No- 4086-28 to 4086-36 of Legrand or equivalent from list of make as approved by GE.
Supply & Fix MCB, Four Pole, 40 to 63 amps, 415 Volts including dismantling, taking down unsv one complete all as specified and directed by Engineer in Charge. MAKE- Cat Part No- 4087-00 to 4087-02 of Legrand or equivalent from list of make as approved by GE.
Supply & Fix Sheet metal enclosure, two way, including dismantling, taking down unsv one complete all as specified and directed by Engineer in Charge. MAKE- Cat Part No-5077 91 to -5077 93 of Legrand or equivalent from list of make as approved by GE.
Material and Labour for taking down old DBs (4 way/6 way/12 way) and repairing, cleaning and refixing of same and making good the disturbed surface neat and clean of any size complete all as specified and as directed by Engineer in Charge.
Supply & Fix MCB distribution board, Double door, metal enclosure, TPN, 415 Volts, 4 way including dismantling, taking down unsv one complete all as specified and directed by Engineer in Charge. MAKE- Cat Part No- 5076 70 of Legrand or equivalent from list of make as approved by GE.
Supply & Fix Vertical MCB distribution board, as MCB incomer, Double door, metal enclosure, TPN, 415 Volts, 4 way including dismantling, taking down unsv one complete all as specified and directed by Engineer in Charge. MAKE- Cat Part No- 5077-25 of Legrand or equivalent from list of make as approved by GE.
Supply & Fix Vertical MCB distribution board, as MCCB incomer, IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 4 way including dismantling, taking down unsv one complete all as specified and directed by Engineer in Charge. MAKE- Cat Part No- 5077-45 of Legrand or equivalent from list of make as approved by GE.
Supply & Fix Metal plug and socket board with MCB SP 20 Amp, 16 KA including dismantling, taking down unsv one complete all as specified nad as directed by Engineer in Charge. Make:- Legrand, Cat No:- 5078 11 or Equivalent from list of make as approved by GE.
Supply & Fix PVC rectangular switch board of size 300mmx 250mm x50mm including necessary cutting slots for mounting switch sockets etc including dismantling, taking down unsv one complete all as specified and directed by Engineer in Charge. MAKE- Presto Teak/Press Fit/Plaza or equivalent from list of make as approved by GE.
Supply & Fix PVC rectangular switch board of size 200mmx 150mm x50mm including necessary cutting slots for mounting switch sockets etc including dismantling, taking down unsv one complete all as specified and directed by Engineer in Charge. MAKE- Presto Teak/Press Fit/Plaza or equivalent from list of make as approved by GE.
Supply & Fix PVC rectangular switch board of size 175mmx 100mm x50mm including necessary cutting slots for mounting switch sockets etc including dismantling, taking down unsv one complete all as specified and directed by Engineer in Charge. MAKE- Presto Teak/Press Fit/Plaza or equivalent from list of make as approved by GE.
Supply & Fix PVC rectangular switch board of size 100mmx 100mm x50mm including necessary cutting slots for mounting switch sockets etc including dismantling, taking down unsv one complete all as specified and directed by Engineer in Charge. MAKE- Presto Teak/Press Fit/Plaza or equivalent from list of make as approved by GE.
Supply & Fix Hylam Sheet 3mm thick on existing concealled MS/CI ractangular or Square or round box with 04 nos cadmium coated screws and cup washer including cutting slots for mounting switch/socket/fan regulator/ batten holder etc including dismantling, taking down unsv one complete all as specified and as directed by Engineer in Charge.
Material & Labour for PL LED tube, 12 Watt, 2 Pin, 230V and including dismantling, taking out unsv CFL complete all as specified and as directed by Engineer in Charge.
Material & Labour for PL LED tube, 12 Watt, 4 Pin, 230V and including dismantling, taking out unsv CFL complete all as specified and as directed by Engineer in Charge.
Material & Labour for PL LED tube, 18 Watt, 4 Pin, 230V and including dismantling, taking out unsv CFL complete all as specified and as directed by Engineer in Charge.
Supply & Fix Round shaped recess mounted LED Flat panel down lighter, 12 Watt (8" dia), PDC Aluminium housing and PMMA difuser suitable for surface/ POP celing complete with all fixing accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable including dismantling, taking down unsv fitting of any type complete all as specified and directed by Engineer in Charge. Make-crompton, Cat part no. LCDSPLN-R-12-CDL or equivalent from list of make as approved by GE.
Supply & Fix square shaped recess mounted LED Flat panel, PDC Aluminium housing and PMMA difuser 12 watt suitable for surface/ POP celing complete with all fixing accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable including dismantling, taking down unsv fitting any type complete all as specified and directed by Engineer in Charge. Make-crompton, cat part no.LCDSPLN-S-12-CDL or equivalent from list of make as approved by GE.
Supply & Fix square shaped recess mounted LED slim Flat panel, suitable for fixing in Aluminium framed ceiling, 36 Watt, 2'X2' size, complete with all fixing accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable including dismantling, taking down unsv fitting any type complete all as specified and directed by Engineer in Charge. Make-crompton, cat part no.LCPL-36-CDL (2X2) (Aura) or equivalent from list of make as approved by GE.
Supply & Fix LED tube 20 watt retrofit LED T8 ( PC ) to existing fluorescent FTL fitting surface mounted after dismantling electronic ballast, internal wiring and complete rewiring with 0.5 sqmm copper flexible conductor FRLSH connector block to one end of Bipi holder and including connecting up to ceiling rose with 0.5 sqmm two core flexible copper conductor cable all as specified and directed by Engineer in Charge. Cat Part No LGT8-20-865-2, Make- crompton or equivalent from List of Make as approved by GE.
Supply & Fix Industrial box type LED Batten with prewired suitable for LED tube 1X18/20 watt, 4' long including dismantling taking down unsv fitting any type complete all as specified and as directed by Engineer in Charge.
S&F LED batten tube type, 2'long, 09/10 watt,CDL 230 Volts, complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable with mounting casing box 2 nos including dismantling, taking down unsv fitting any type complete all as specified and directed by Engineer in Charge. Make-HPL Cat Part No- HLPT51509PCGCW or equivalent from list of make as approved by GE.
Supply & Fix LED fitting, 20 watt, CDL, 230 Volts, 4 feet long, complete with all accessories internally pre wired and including connecting upto ceiling rose with 0.5 sqmm twin core copper flexible conductorcable including LED lamp and mounting casing box 2 nos, including dismantling, taking down unsv fittings any type complete all as specified and as directed by Engineer in Charge. Make:- Shakti, Cat Part No- SZSLAMX010 or equivalent from list of make as approved by GE.
Supply & Fix LED building security light 15 watt, 230V with lens complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade 20 mm dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener including dismantling, taking down unsv fitting any type complete all as specified and directed by Engineer in Charge. Make- Shakti, Cat no:- SZPSLMM015 or equivalent from list of make as approved by GE.
REPAIR TO CEILING FANS WITH FOLLOWING ITEMS OF WORK :- Material & Labour for Rewinding of Ceiling fan 1200/1400 mm sweep after dismantling complete motor assembly, bearings, bushings, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size/turn of super enamelled copper wire, heating, varnishing, replacement of unsv bearings / bushings, assemble of rotor and stator unit with capacitor, connecting wire, down rod, blades and testing complete all as specified and as directed by Engineer in Charge.
Note for Item no 48:- (i) Contractor shall collect fans from the complaint cells of specified area and bring back to complaint cell after repair. Cost of transportation is deemed to be inclusive in the quoted rate. (ii) Spares that shall be replaced such as bearing, Bushing, Capacitor shall be measured and paid separately as supply & Fixing only under relevant item of this schedule. (iii) Cost of Connector block and capacitor holder is deemed to be inclusive in the quoted rate.
All as per item No- 48 here-in-above but for Exhaust fan 380/450 mm sweep industrial type.
All as per item No- 48 here-in-above but for Exhaust fan 250/300 mm sweep industrial type.
All as per item No- 48 here-in-above but for Exhaust fan 250/300 mm sweep/wall fan Domestic type.
Supply & Fix ball bearing No 6201/6202/6203/6204 of SKF/Tata/NBC complete all as specified and as directed by Engineer in Charge.
Supply & Fix G.M. Bush bearing for ceiling fan as per existing pattern complete all as specified and as directed by Engineer in Charge.
Supply & Fix Capacitor AC for 230 volts 50 Hz of capacity 1.8 Mfd complete all as specified and as directed by Engineer in Charge.
Supply & Fix capacitor AC for 230 volts 50 Hz of capacity 2.0/2.25/2.5 Mfd complete all as specified and as directed by Engineer in Charge.
Supply & Fix capacitor AC for 230 volts 50 Hz of capacity 3.15 Mfd complete all as specified and as directed by Engineer in Charge.
Supply & Fix capacitor AC for 230 volts 50 Hz of capacity 4.0 Mfd complete all as specified and as directed by Engineer in Charge.
Material & Labour for Painting of Ceiling fan 1200/1400 mm including scrapping, cleaning and removing dust from the blade and body and applying two coat of synthetic enamel paint over one coat of primer complete all as specified and as directed by Engr-in-charge.
Supply & Fix in repair of exhaust fan 300 mm, PVC body, 230 Volts including dismantling, taking down unsv fitting any type complete all as specified and directed by Engineer in Charge.
Supply & Fix PVC insulated PVC sheathed copper flexible wire, multistrand 4sqmm 3 core, ISI marked complete all as specified and as directed by Engineer in Charge.
Supply & Fix in repair thermostat ISI marked suitable for geysers 25 Ltrs to 50 Ltrs Capacity complete all as specified and as directed by Engineer in Charge. Make- Bajaj/Venus/Recold as approved by GE.
Supply & Fix in repair fusible plug marked suitable for 25 and 50 ltrs capacity Geysers complete all as specified and directed by Engineer in Charge.
Supply & Fix in repair heating element Marked round/ triangular bas, push type or thread type including rubber washers for 1.5/2.0 KW complete all as specified and directed by Engineer in Charge.
Supply & Fix in repair inner water container made of SS, vertical or horizontal type for 25/50 ltr capacity geyser complete all as specified and directed by Engineer in Charge.
Supply & Fix in repair of aparatus plate suitable for vertical/ horizontal type Geyser 25 or 50 ltr capacity complete all as specified and directed by Engineer in Charge.
Supply & Fix in repair heavy duty PVC connections pipe with brass hexagonal adoptersat both side 15mm dia and 450mm long for hot /cold water complete all as specified and directed by Engineer in Charge.
Material & Labour for testing of earth resistance value of building earth for electrical purpose, using analog/digital earth resistance tester by suitably inserting spikes as per norms and recording earth resistance value of building in presence of MES Repand user Rep and submission of recorded value in hard copy duly signed complete all as specified and as directed by Engineer in Charge.
Material and Labour for Earthing Complete with galvanised steel pipe electrode, 40 mm bore, medium grade, 3 meter long buried directly and vertically in ground with top edge at ground levelafter making bore hole of size not less than 300mm dia and 3.0 mtr long using suitable mechanical drilling rig (for drilling near the specified building), connected with galvanized steel earthing lead of 4mm dia all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 Type C2 with RCC Precast Pit Cover slab 400mm X 400mm X 80mm with handle for lifting made out of 8mm dia MS Rod, funnel, wiremesh, 15mm dia light grade GI Tubing for protection of GI wire 4mm dia, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in & removal complete all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion complete all as specified and as directed by Engineer in Charge.
ASHWAMEDH ENGINEERS
ONKAR ELECTRIC AND GENERAL STORE
metro electrical services
M/S. OM ENTERPRISES
TULAJA ENTERPRISES
T.H.ASSOCIATES
M/S kirpan Enterprises
AN-ICON Engineering Technologies And Infrastructure Developments Pvt. Ltd
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .