Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.1 LAccepted-AOC NOT SPECIFIED | L1 | Accepted-AOC Bidder quoted L1 rates | |
| 2 | L2₹49.5 L+₹1.3 L (2.79%)Rejected-Finance 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L2 | Rejected-Finance Bidder not quoted L1 rates | |
| 3 | L3₹51.5 L+₹3.4 L (6.99%)Rejected-Finance FLAT NO 601 TOWER NO 30 SECTOR NO 21 AMANORA PARK TOWN HADAPSAR PUNE 411028 | PUNE | MAHARASHTRA | 411028 | L3 | Rejected-Finance Bidder not quoted L1 rates | |
| 4 | L4₹52.4 L+₹4.3 L (8.87%)Rejected-Finance | L4 | Rejected-Finance Bidder not quoted L1 rates |
| Sl No | Description | Qty | Unit | United Sales Corporation L1 | TIMES HYDRO-ELECTRIC COMPANY L4 | UNIQUE ENGINEERS L3 | Prasur Electricals & Engineering Co. L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | M&L for Removing / Dismantling the existing DG Sets alongwith alternator complete including Diesel tank, panel boards, cables, silencer pipe etc and transporting the entire plant machineries to MES store yard approx 7 Km complete all as specified and directed.
(NOTE : The existing DG Set plinth / foundations shall be totally demolished to ground level and the debris shall be removed to a distance of 500 mtrs and to make good the disturbed floor to match with the existing floor finish all as directed. The cost thereof shall deemed to be included in quoted rate.) | 1 | EACH JOB | 15,000 ₹15,000 Lowest | 24,000 ₹24,000 | 40,000 ₹40,000 | 25,000 ₹25,000 |
| 2.00 | Supply install testing and commissioning Silent type Diesel Engine Generating set 415 volts 400 KVA 3 -phase 0.8 power factor 50 Hz, 1500 RPM self excited self regulated brushless AC generator alongwith AMF panel outdoor type installed including accoustic enclosure suitable for ambient condition at Pune and confirming to latest upgraded conditions of Central Pollution Control Board (CPCB IV +), IS 4722, 10001/10002, 13364, BS 5514/2613/5000 and fulfill the latest upgraded conditions of CPCB with following specifications :- | 1 | EACH JOB | 47,00,000 ₹47,00,000 Lowest | 51,00,000 ₹51,00,000 | 49,85,000 ₹49,85,000 | 47,90,000 ₹47,90,000 |
| 2.01SER. ITEM No. 2.00 Contd.... (A) Alternator :- Standard design alternator rated at 400 KVA net output at site after considering derating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self exicited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of + 1% at rated voltage from no load to full load. The alternator shall be confirming to BS 2613/5000, IS/IEC 60034-1 and shall be in position to generate supply with frequecy regulation with in + 1% tolerace. The alternator should be suitable for tropical climate and shall generally confirm to BS - 2613/5000. Alternator Features: (i) Compliance to revised CPCB norms. (ii) Alternator should be compact in design & with AREP winding and digital AVR. (iii) Temperature rise Class - 'H' | |||||||
| 2.02SER. ITEM No. 2.00 Contd.... (B) Diesel Engine : - Adequate capacity of Diesel engine as accepted by the Accepting Officer based on manufacturers technical details water cooled to drive independently above alternator and after considering derating as per site conditons after generating and reducing power consumed by accessories directly coupled through flexiable coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS -10001/10002/ 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:- i) Fly wheel with housing ii) Cooling system :- Moulded Aluminium fins radiator with fan & belts. iii) Cooling Water pump : Suitable capacity. iv) Exhaust System :- Exhaust System complete with exhaust piping. Exhaust gas turbo charger type Exhaust manifold Silencer : Residual type/Hospital grade Bellows v) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by governor electronic operated/ (as recommended by OEM) for 1% speed /frequency regulation. Fuel filters spine on type Fuel hoses | |||||||
| 2.03SER. ITEM No. 2.00 Contd.... vi) Lube oil System :- Spine on type Lubricating oil filter Lubricating oil pump vii) Air Intake System :- Air intake Manifold with necessary connection Air cleaner dry type, turbo Charger viii) Governor electronic / (as recommended by OEM) controlled direct fuel injection system ix) Suitable capacity of DEF tank and filling as required level by the OEM x) Starting System :- Electric Self starter with and including battery charging alternator. xi) Batteries :- Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multistranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified. xii) Generator Monitoring Panel : - (a) Comprising of all standard items as mentioned under this schedule or as per standard practice ignition key switch and start / stop arrangement, indications for Engine parameters, hour run meter, RPM meter, Engine oil pressure indicator, water/coolant temperature indicator, Battery volt display. (b) Phase voltage & Currents, Frequency, Genset, kVA, kW, kWh, kVAr & PF (c) Lube oil pressure, Engine Temp, RPM ,Run Hours, Number of starts, Fuel level, Auto/Manual stop, Battery charging condition, AMF feature | |||||||
| 2.04SER. ITEM No. 2.00 Contd.... Diagnostic Features: (i) Battery charging failure, Over/Under speed, Over Current, Over/Under Voltage, Over KW, Phase sequence, Phase missing, Mains Under voltge, Earth fault trip, Low Fuel level (ii) Low Lube oil pressure, High Engine Temp, Low/High battery voltage, Low Fuel level, Over crank protection, Routine maint indicator, Genset test facility, Mains Frequency. xii) Safety Controls : - Engine low lube oil pressure high/low water temparature and over speeding of engine. Battery over/under/weak, Fail to crank/start, low coolant level, sensor failure. xiii) Coupling arrangement: - Flange coupling with rubber gasket to couple with fly wheel. xiv) Accessories :- AVM Pads built or separately mounted to manufacturer base frames (as recommended by OEM) xv) Base Frame : - Made out of ISMC of sturdy design made of MS channel with necessary reinforcement and predetermined holes. xvi) Fuel Tank :- Daily service fuel tank (as recommended by OEM) with calibrated level indicating arrangement, stop cock, drain plug, complete on a common base in side the acoustic enclosure. | |||||||
| 2.05SER. ITEM No. 2.00 Contd.... (C) Rubber Matting of LV grade 19mm thick of suitable size chequered type ISI marked to be laid in front of control panel shall be provided (D) Acoustic Enclosure:- Manufactured by OEM suitable for400 KVA DG Set. (i) NAL approved as per latest CPCB norms (ii) It shall be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board. (iii) The generating set batteries and control panel shall be inside the enclosure. (iv) Fuel tank shall be inside the enclosure. (v) Construction Details/specification are as follows : - a) Outer body :- CRCA Sheet of 1.6mm thick. b) Doors :- CRCA sheet of 1.6 mm thick c) Sound Insulation :- 100 mm thick rock wool (96kg/Cum density) vi) The accoustic shall be composite in construction and fully assembled integral unit conforming to IS-8183 vii) The batteries shall be placed inside the enclosure beside the DG Set on a suitable insulated plat form. viii) The DG Set shall be provided with external Emergency stop push button. ix) The enclosure shall be suitably illuminated by LED Lamp fittings. x) The noise level shall be 75 Db at 1m under free field conditions. xi) The acoustic enclosure parts shall be of powder coated after pre-treatment process. The powder coating shade shall be Genset Green. The base frame shall be painted with epoxy based black shade. | |||||||
| 2.06SER. ITEM No. 2.00 Contd.... (E) AMF Control Panel : Factory fabricated, Cubical type, free standing, floor mounted, outdoor/indoor type, CPRI approved AMF Control Panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 3.0 mm thick CRCA Sheet of size 1500mm x 1500mm x 750mm including two coats of powder coated paint over a coat of red oxide primer etc. and comprising of following: (i) AMF with relay based control circuit, four pole MCCB 630 Amp 415 V 36 KA. for main supply and DG set supply MCCB 630 Amp, four pole, 415 V 36 KA complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating Engine start, stop three attempt starting facility and failure to start etc. (ii) Digital Multi function meter to measure PF, KWh, KVA, KVAh etc (iii) Current Transformers of suitable CT ratio. (iv) Indicating lamps for supply 'ON' and load 'ON' (v) Instrument controlled by MCB SP of suitable capacity (vi) Push button 01 No each for start, stop, and re-set (vii) Aluminium bus bar of capacity 1000 Amp for all phases and neutral (viii) Bottom gland plate including glands for incoming and outgoing LT cables (ix) Circuit diagram plate (x) 3 Phase KWH meter Digital type (xi) Contactors 630 Amps and complete connected items - 02 Nos. | |||||||
| 2.07SER. ITEM No. 2.00 Contd.... Notes :- (i) The capacity of Generator set shall be net after all due derating factors as per relevant ISI design. (ii) Rate quoted shall be deemed to be inclusive of cable terminations from Generator to the Panel all as specified and directed. (iii) The quoted rate shall be deemed to be inclusive of first fill of oil and FOL for final successful acceptance test. (iv) The contractor shall arrange for external artificial load bank and fuel for Phase-I and phase -II testing of DG Set at site and the cost thereof shall deemed to be included in the quoted rate without any extra cost to the Deptt. (v) The quoted rate shall be deemed to be inclusive of 12 hours test run at site including of half an hour on 10% overhead in presence of representative detailed by accepting Officer, all arrangements are to be made by the contractor for tests. (vi) Cost of all civil works including PCC platform and foundations work required for panel/DG Sets and equipments including making good during installation and commissioning of genset shall deemed to be included in quoted rate. The depth of the foundation and PCC shall be provided as per recommendations of the manufacturer/OEM. (vii) Cost of necessary cable / communication cables of suitable size for DG set to AMF panel and battery charger shall deemed to included in quoted rate. | |||||||
| 3.00 | M & L for Earthing with 600mm x 600mm x 6.00mm Galvanised steel earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5 m below ground level, connected to and including Galvanised steel Strip of size 32x6 mm by means of bolts, nuts and check nuts and washers of galvanised steel with and including 40 mm dia GI medium grade pipe for protection of GI strip to the extent of 7.5 metres as earthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per Electrical Plate No. 3 of SSR Part I (2009) including PCC foundation / chamber in mix 1:2:4 type B1 with M.S. angle iron frame, C.I. Cover with provision of locking arrangement and 20 mm dia light grade G.I. Pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement, complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal of excavated material from the site complete all as specified and directed.
Note :- Cost of earth protection pipe & earthing strip upto and including 7.5 m length is deemed included in unit rate quoted by the contractor. | 6 | EACH | 5,000 ₹30,000 Lowest | 6,900 ₹41,400 | 6,500 ₹39,000 | 8,750 ₹52,500 |
Tender Value
₹47.8 L
EMD Value
₹95,700
Closing Date
3 Sept 2025, 6:00 pmClosed
COMMANDER WORKS ENGINEER PUNE
HEADQUARTERS COMMANDER WORKS ENGINEERS GEN CARIAPPA MARG, PUNE-411 001
86209 SPL REPAIR / REPLACEMENT AGAINST BER DG SET ALONG WITH ITS OTHER CONNECTED ACCESSORIES FOR AFMC UNDER GE (CENTRAL) PUNE
2025_MES_724756_1
86209 CWE PUNE
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
GE (CENTRAL) PUNE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (CENTRAL)
₹95,700
Yes
29 Oct 2025
6 Aug 2025
10 Sept 2025
6 Aug 2025
3 Sept 2025
20 Aug 2025
6 Aug 2025 - 12 Aug 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .