Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹1.4 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹1.4 Cr+₹2.0 L (1.50%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹1.4 Cr+₹2.0 L (1.50%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹1.7 Cr+₹33.7 L (24.8%)Rejected-Finance JAMMU AND KASHMIR JAMMU AND KASHMIR | JAMMU | JAMMU AND KASHMIR | 181122 | ₹1.7 Cr+₹33.7 L (24.8%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹1.8 Cr+₹44.1 L (32.4%)Rejected-Finance 1ST 2ND FLOOR PLOT NO 13 C 13 3 RAMA ROAD SIDE INDUSTRIAL AREA NAJAFGARH ROAD DELHI 110015 INDIA | WEST | DELHI | 110015 | ₹1.8 Cr+₹44.1 L (32.4%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹1.8 Cr+₹45.0 L (33.1%)Rejected-Finance | ₹1.8 Cr+₹45.0 L (33.1%) | L5 | Rejected-Finance Other than lowest |
Tender Value
₹2.4 Cr
EMD Value
₹3.1 L
Closing Date
17 Jun 2024, 6:00 pmClosed
Chief Engineer Udhampur Zone
HQ Chief Engineer Udhampur Zone Pin 900386, C/O 56 APO
REPLACEMENT OF OH CONDUCTION WITH UG CABLES AT SUNDERBANI UNDER GE (N) AKHNOOR
2024_MES_652901_1
87933-A/E8
Open Tender
Civil Works
Item Rate
365 days
Akhnoor
As per NIT
8 documents required · 8 mandatory
₹2,000
GE (N) Akhnoor
₹3.1 L
Yes
30 Aug 2024
9 May 2024
20 Jun 2024
9 May 2024
17 Jun 2024
12 Jun 2024
Amount
Dismantling steel/PCC poles/struts of any size, complete all as specified and directed.
Dismantling Cross arms of MS channel or angle sections etc. complete all as directed.
Dismantling Insulators any type, any size complete all as directed.
Dismantling Stay assembly complete all as directed.
Dismantling Earth wire or copper conductor,service feeder or distributor span complete all as directed.
Dismantling of ACSR conductors complete all as directed.
Taking down street light fittings including GI bracket complete all as directed. Note:- Street light fittings shall be deposted to MES store yard.
Steel tubular swaged pole complete with base plate welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-31 (9.0m long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC, complete all as specified and directed. Note :- PCC, earth work shall be measured & paid separately under respective items.
Loop in/loop out cable, juntion/terminal box for cable connection made out with thermoplastic of size 200mm x 160mm x 98mm including MCB SPN 6 Amps 230 Volts with provision of external fastening with metric knockouts for cable entry & outgoing for service connection to security light complete all as specified and as directed.
Galvanaised iron tubing light grade of size 20 mm dia, 6 meter long suitable for 1.5 sqmm, 3 core cable of length 7 meter from looping box to street light connector, holding in MS clamp of size 25X2 mm thick at every one mtr used in each pole 04 Nos of clamps with necessary nut, bolts and washers etc and including PVC sheathed three core multistranded copper conductor cable of size 1.5 sqmm from looping box to security light fitting connector complete all as specified and directed.
Stay assembly complete with aceessories and stay rod 20mm dia and 180cm long, stay bow 14mm dia and 40cm long, stay wire of size 7/4mm, stranded galvanised including MS Galvanised stay plate 300mm x 300mm x 6mm, galvanised thimble stay clamps and loop type insulator complete all as specified and as shown in electric plate No. 01 of SSR Part-I (Specification). Note :- Excavation & concrete measured and paid separately.
Earthing complete with galvanised steel earth plate elcrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground) with top edge of plate not less than 1.5m below normal ground level connecting to the GI earthing strip 32x6mm by means of bolts, nuts check nuts and washers of galvanised iron and GI Strip 32x6mm protected by provision of GI Light grade pipe of 40mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregrate with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4Kg/sqm) and frame of angle iron 25x25x6mm with lugs 02 nos and 6mm dia MS bars handle made to shape, GI Light grade 20mm bore pipe for watering perforated at bottom 1.75m long placed on top edge for earth plate incl common salt and charcoal filling, test point made out of 75x50x6mm phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50m all as per electrical plate no 3 of SSR 1991 Pt-I and connecting to earth test point incl testing on the site, complete all as specified and directed.
Earthing complete with steel earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanised iron earth wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and steel earthwire protected by provision of GI Medium grade pipe 15 mm bore including provision of concrete pit made from PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25 x 25 x 6 mm with lugs 02 No and with 6 mm dia MS bar handle made to shape GI medium grade 20 mm bore pipe for watering perforated at bottom, 1.75 metere long placed on top edge of earth plate, common salt and charcoal fittings, test point made out of 17 mm x 8 mm FI with fixing arrangement, funnel wire mesh and earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 M all as per electrical plate No.03 of SSR Part- I connected to earth test point complete all as specified and directed or indicated including testing on completion.
Supply, laying, jointing and testing, laid in trenches/road crossing/under floor/on walls/on poles including clamps or passing through pipes, 1100 volts grade, LT XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor of following cross sectional area complete all as specified and directed.
Cross sectional area 150 Sqmm, 3.5 core.
Cross sectional area 120 Sqmm, 3.5 core.
Cross sectional area 95 Sqmm, 3.5 core.
Cross sectional area 70 Sqmm, 3.5 core.
Cross sectional area 50 Sqmm, 3.5 core.
Cross sectional area 35 Sqmm, 3.5 core.
Cross sectional area 25 Sqmm, 4 core.
Cross sectional area 16 Sqmm, 2 core.
Note for Srl item No. 14.00 :- (a) Earth work shall be measured and paid separately. (b) The quoted rates shall be deemed to be include the following :- (i) Colour code of LT cables shall be as per IS standard. (ii) Pre-dispatch inspection of LT cables shall be carried out at manufacture's factory by the rep of Accepting Officer before dispatching to site. (iii) Cable shall be marked or embossed as 'GE (N) Akhnoor' at every one metre length.
Cable jointing kit for 1100V grade cable for straight through joint complete, heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE, armoured, aluminium conductor cable of size 25 Sqmm to 50 sqmm, complete all as specified and directed.
Cable jointing kit for 1100V grade cable for straight through joint complete, heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE, armoured, aluminium conductor cable of size 70 Sqmm to 95 sqmm, complete all as specified and directed.
Street light bracket made out of 40mm dia medium grade GI pipe of 1.2m length bent to required shape suitable for fixing street light/security light fitting on Steel tubular pole/RCC pole/building wall including two Nos clamps made out 30mm X 5mm flat with suitable nuts and bolts (clamp type - as per site requirement) including two coats of aluminium paint over a coating of red oxide primer, complete all as specified and directed.
LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete all as specified and directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc and getting out in any type of soil complete all as specified and directed.
All as per Srl item No. 25 here-in-before but for depth exceeding 1.5m and not exceeding 3.00m deep.
Plain cement concrete 1:2:4 type B-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
Plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
Plain cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in pole coping and chamfered on adges including use of form work complete all as specified and directed.
Returning, filling in any type of soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Reel type insulator 65 mm dia x 31 mm hole x 20 mm hole complete all as specified and directed.
Double walled corrugated (DWC) pipe of size 40mm/ 32 mm (OD/ID) including snap fit coupler conforming to IS14930 (Pt-II) IS16205 (Pt-II) for protection of cable in underground complete all as specified and directed.
Double walled corrugated (DWC) pipe of size 63mm /51mm (OD/ID) including snap fit coupler conforming to IS14930 (Pt-II) IS16205 (Pt-II) for protection of cable in underground complete all as specified and directed.
Double walled corrugated (DWC) pipe of size 75mm /63mm (OD/ID) including snap fit coupler conforming to IS14930 (Pt-II) IS16205 (Pt-II) for protection of cable in underground complete all as specified and directed.
Double walled corrugated (DWC) pipe of size 90mm /76mm (OD/ID) including snap fit coupler conforming to IS14930 (Pt-II) IS16205 (Pt-II) for protection of cable in underground complete all as specified and directed.
Double walled corrugated (DWC) pipe of size 120mm /103mm (OD/ID) including snap fit coupler conforming to IS14930 (Pt-II) IS16205 (Pt-II) for protection of cable in underground complete all as specified and directed.
Double walled corrugated (DWC) pipe of size 160mm /135mm (OD/ID) including snap fit coupler conforming to IS14930 (Pt-II) IS16205 (Pt-II) for protection of cable in underground complete all as specified and directed.
Deduction to be made from BOQ for Sch 'A' Part - II (Schedule of credit) Amount of Rs. 4,44,985.00 during AOC. Note :- Tenderers shall not quote for this schedule.
R D Bansal
V K Sales and Construction Co
Vardhman Airport Solutions Private Limited
RSP Contractors India Private Limited
FANGALIA TRADERS
SHREE KARNI LIGHT HOUSE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .