Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹1.3 L
Closing Date
2 Apr 2022, 6:00 pmClosed
GE Project Bangalore
GE Project Bangalore
Soil Investigation
2022_MES_513894_1
3011/18/E3
Open Tender
Job Works
Works
60 days
GE Project Bangalore
As per tender documents
2 documents required · 2 mandatory
₹0
Exempted
5 Apr 2022
15 Mar 2022
4 Apr 2022
16 Mar 2022
2 Apr 2022
18 Mar 2022
SOIL INVESTIGATION FOR BUILDING (a) Drilling of bore holes of 100mm-150 mm by shelf and auger with MS casing up to a depth possible beyond which diesel operated clay drill bent on it slurry to be used. Depth of bore holes may be taken as min 15m or N value reaches 50, whichever is earlier. Disturbed and undisturbed soil samples to be collected during SPT test laboratory investigation to be carried out as per IS-2131 specification. Soil samples shall be collected and handed over to Engr-in-Charge in wooden boxes. Drilling rate upto 6m including submission of report. (Mobilisation rate as per quotation) (b) Submission of Report and testing of bore holes with analysis of under mentioned tests and recommendation should be submitted in Six copies :- (i) The bore hole may be terminated before 15m if N value reaches 50, carryout SPT in the bore holes to determine N value. (ii) SPT value at every 0.75m intervals and change of strata. (iii) Grain size distribution and analysis. (iv) Soil characteristics. (v) Value of cohesion and angle of internal friction. (vi) Recommended SBC at different depths of foundation i.e at 1000mm, 1200mm, 1500mm & 1800mm, etc upto 5m depth. (vii) SBC and its calculation based on ‘N’ value shear strength and settlement criteria. (viii) Depth of water table (maximum and minimum). (ix) Depth of expansive soil and its properties, if any. (x) Recommendation for type of foundation. (xi) Recommendation for filling under floors and filling under protection including plinth protection. (xii) Chemical analysis of soil & water samples. (xiii) Details of soil profile and bore logs. (xiv) Any other recommendation. (xv) Location of bore should be shown alongwith the proposed bldg layout in the report in a site plan duly signed by GE and testing Lab rep. (xvi) Testing should be done only at NABL recognized test house/Govt Engineering College as per NBC, IS 1892, 2131, 2132, 1888, 2720, 1904, 6403, 8009, 1498 and SP 36 in general containing. (xvii) Water table level, chemical characteristics of soil eg. Chloride and Sulphate content and expansive characteristics of soil if any should be given in the report. (xviii) The levels of each SPT bores shall be reflected with respect to permanent bench mark levels.
SILOAM GEOTECH SERVICES LLP
Geo Quest Incorporation
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .