| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.2 LAccepted-AOC D 154 ADARSH NAGAR JABALPUR MP 482001 | JABALPUR | MADHYA PRADESH | 482001 | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹37.0 L+₹2.6 L (7.58%)Rejected-Finance 116 JAI BHEEM NAGAR POLIPATHAR GWARIGHAT ROAD JABALPUR MP 482008 | JABALPUR | MADHYA PRADESH | 482008 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹38.2 L+₹3.9 L (11.3%)Rejected-Finance HDLX 31 JASUJA CITY JABALPUR MP 482003 | JABALPUR | MADHYA PRADESH | 482003 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹38.6 L+₹4.2 L (12.3%)Rejected-Finance HOUSE NO 25 CANTT BOARD WARD SADAR BAZAR CANTT JABALPUR MP 482001 | JABALPUR | MADHYA PRADESH | 482001 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹39.3 L+₹5.0 L (14.4%)Rejected-Finance 1 SANCHAR NAGAR NEAR KRISHI UPAJ MANDI DAMOH ROAD JABALPUR M P | JABALPUR | MADHYA PRADESH | 482001 | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | Kirti Chandeliya and Assosicates L5 | RP ANAND L1 | ANAMIKA CONSTRUCTION L3 | chandra builders L2 | Arpit dixit construction L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of cement concrete (unreinforced) in ground floors and paving n exc 15 cm thickness incl part chipping (below or above ground level) complete all as specified and as directed. | 8.49 | Cum | 50 ₹424.5 Lowest | 200 ₹1,698 | 200 ₹1,698 | 200 ₹1,698 | 150 ₹1,273.5 |
| 2.00 | Demolition of brick work or stone/boulder masonry built in cement mortar of any description including all quions, arches, pillars, etc excluding ashlar facings, preacast concrete articles complete all as specified and as directed. | 3 | Cum | 60 ₹180 Lowest | 150 ₹450 | 125 ₹375 | 100 ₹300 | 150 ₹450 |
| 3.00 | Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth ;for foundation etc.or for shafts well cesspit,maholes, pier holes etc.n exc 10 sqm on plan area as in soft /loose soi complete all as specified and as directed | 50 | Cum | 170 ₹8,500 | 150 ₹7,500 | 125 ₹6,250 Lowest | 200 ₹10,000 | 150 ₹7,500 |
| 4.00 | Excavation in trenche ,n exc 1.5m wide and exc 1.5m in depth but n exc 3.0m in depth ;for foundation etc.or for shafts well cesspit,maholes, pier holes etc.n exc 10 sqm on plan area as in soft /loose soi complete all as specified and as directed | 10 | Cum | 180 ₹1,800 | 150 ₹1,500 | 145 ₹1,450 Lowest | 250 ₹2,500 | 250 ₹2,500 |
| 5.00 | Excavating in post holes (or similar holes) each n.exc 0.5 cu.m getting out, returning filling in and ramming earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface as in soft and loose soil complete all as specified and as directed. | 54 | Each | 100 ₹5,400 | 30 ₹1,620 Lowest | 90 ₹4,860 | 150 ₹8,100 | 100 ₹5,400 |
| 6.00 | Returing, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft /loose soil,complete all as specified and as directed. | 8 | Cum | 70 ₹560 | 20 ₹160 Lowest | 40 ₹320 | 50 ₹400 | 100 ₹800 |
| 7.00 | M&L for PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete,complete all as specified and as directed. | 10 | Cum | 3,000 ₹30,000 | 2,800 ₹28,000 | 2,500 ₹25,000 Lowest | 2,700 ₹27,000 | 3,900 ₹39,000 |
| 8.00 | M&L for cement concrete type C-2 1:3:6 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. | 7.57 | Cum | 3,600 ₹27,252 | 3,200 ₹24,224 | 3,000 ₹22,710 Lowest | 3,000 ₹22,710 Lowest | 4,000 ₹30,280 |
| 9.00 | M&L for cement concrete type C-0 1:3:6 (using 12.5 mm graded stone aggregate) as in surface channels and drains complete all as specified and as directed. | 2 | Cum | 4,800 ₹9,600 | 3,200 ₹6,400 | 3,200 ₹6,400 | 3,000 ₹6,000 Lowest | 4,100 ₹8,200 |
| 10.00 | Taking down cement plaster on brick/ stone masonary including raking out joints, hacking for scrubbing down with water etc. complete all as specified and as directed. | 100 | Sqm | 15 ₹1,500 | 25 ₹2,500 | 10 ₹1,000 Lowest | 20 ₹2,000 | 20 ₹2,000 |
Tender Value
₹45.1 L
EMD Value
₹90,140
Closing Date
24 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
SPL REPAIR TO BLDG NO P-186 OF COBRA OFFRS MESS AND CERTAIN MINOR AND REV WORKS IN THE AREA OF AGE B/R-I UNDER GE (WEST) JABALPUR
2025_MES_710619_1
8876/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Jabalpur
As per tender documents
6 documents required · 6 mandatory
₹500
GE (West) Jabalpur
₹90,140
8 Sept 2025
27 May 2025
27 Jun 2025
28 May 2025
24 Jun 2025
10 Jun 2025
28 May 2025 - 5 Jun 2025
Amount
Demolition of cement concrete (unreinforced) in ground floors and paving n exc 15 cm thickness incl part chipping (below or above ground level) complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry built in cement mortar of any description including all quions, arches, pillars, etc excluding ashlar facings, preacast concrete articles complete all as specified and as directed.
Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth ;for foundation etc.or for shafts well cesspit,maholes, pier holes etc.n exc 10 sqm on plan area as in soft /loose soi complete all as specified and as directed
Excavation in trenche ,n exc 1.5m wide and exc 1.5m in depth but n exc 3.0m in depth ;for foundation etc.or for shafts well cesspit,maholes, pier holes etc.n exc 10 sqm on plan area as in soft /loose soi complete all as specified and as directed
Excavating in post holes (or similar holes) each n.exc 0.5 cu.m getting out, returning filling in and ramming earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface as in soft and loose soil complete all as specified and as directed.
Returing, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft /loose soil,complete all as specified and as directed.
M&L for PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete,complete all as specified and as directed.
M&L for cement concrete type C-2 1:3:6 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for cement concrete type C-0 1:3:6 (using 12.5 mm graded stone aggregate) as in surface channels and drains complete all as specified and as directed.
Taking down cement plaster on brick/ stone masonary including raking out joints, hacking for scrubbing down with water etc. complete all as specified and as directed.
Dismantling floor , hearth or wall tiling including cement mortar bedding (but not backing ) removing rubbish outside MD land complete all as specified and as directed.
M&L for broken bricks or brick bat loose filligs with aggregate of gauge 80 to 150mm in soakage pits,soakage well complete all as specified and as directed
M&L for Extra for forming fair finish for channel 30 cm inner girth in cement concrete using extra cement incl form, mould,mitred/stopped etc complete all as specified and as directed
M&L for Concrete bed to drain pipes including packing under and haunching against the sides of pipes after the air laid and tested in Cement Concrete 1:3:6 type C2 (using 40mm graded stone aggregate) for bore of pipes 150 mm dia complete all as specified and as directed.
M&L for Concrete bed to drain pipes including packing under and haunching against the sides of pipes after the air laid and tested in Cement Concrete 1:3:6 type C2 (using 40mm graded stone aggregate) for bore of pipes 200 mm dia complete all as specified and as directed.
M&L for double wall corrugated (DWC) pipes 150 mm bore inner dia class class SN-8 confirming to IS-16098:2013 (Part-2) laid and jointed, with collars complete all as specified and as directed
M&L for double wall corrugated (DWC) pipes 200 mm bore inner dia class class SN-8 confirming to IS-16098:2013 (Part-2) laid and jointed, with collars complete all as specified and as directed
S&F, for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description, over 10cm width or girth including preparation complete all as specified and as directed.
M&L for MS work as in wind ties for roof including securing bolts, drilling holes, notching for wire etc complete all as specified and as directed.
Supply only liquid water proofing compound complete all as specified and as directed.
M&L for 20-25mm machine cut kota stone slab flooring thick laid and jointed with grey cement slurry mixed with pigment over and including 20mm thick screed bed or bedding layer in CM 1:6 to match the shade of the slab including rubbing and mirror polishing complete all as specified and as directed.
M & L for precast cement concrete type B-1 1:2:4 ( using 20 mm graded stone aggregate ) as in landing cover slab and set in CM 1:4 including necessary form work if required complete all as specified and as directed.
S&F for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming,complete all as specified and as directed.
S&F for TMT bars 8mm dia cut cut to length bent to shape required including binding with mild steel wire (annealed) not less than 0.9 mm dia, complete all as specified and as directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Dismantling of timber scantlings as in unframed work 40Sq Cm and over in section, in any position complete all as specified and as directed.
Dismantling of plain/ corrugated AC/Steel Roof sheeting of any description including stacking and removing to store complete all as specified and as directed.
Use & waste for form work to soffits of suspended slab such as roof slab, floor slab , landing and similar work; not exc 200 mm thick horizontal or sloping, finished fair and even complete all as specified and as directed.
Formwork to edges of concrete flats, treads, breaks in floors,window cills, concrete railings,openings in concrete walls, floor and roofs and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 5cm but n exc 10cm wide Rough finished surfaces of concrete complete all as specified and as directed
M & L for RCC 1:2:4 type B1 using 20mm graded aggregate in slabs supported on wall and beams and column in floors,roofs landing etc,complete all as specified and as directed.
M&L for 25 mm thick plain cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in base finishing the surface even and smooth complete all as specified and as directed.
M&L for Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and as directed.
M&L for 75mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate, as in plinth protection laid in panels and finished even and smooth without using extra cement including necessary form work complete all as specified and as directed.
M&L for 15 mm thick rendering on fair faces of brick work concrete surfaces in CM (1:6), finished even and smooth (without using extra cement ) complete all as specified and as directed.
M&L for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding/ ridge to wall, fixed with self tapping screws complete all as specified and as directed.
M&L for Rolled sections of Fe 410 -W (Gde-E- 250) quality-A as in main and cross beams, hip and jack rafters purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates complete all as specified and as directed.
M&L for 150 mm thick cement concrete type C-2, 1:3:6 using 40mm graded stone aggregate as in sub-base complete all as specified and as directed.
S & F for 2nd class hardwood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and as directed.
S & F for 35 mm thick 2nd class hardwood moulded glazed/gauged door with pre pressed lamination on both side, solid core construction & prepared to receive glass/wire mesh including fixing of SS wiremesh of nominal dia 0.36 mm , 2 Nos door handle, 0.3 Nos butt hing of 100mm , 2 nos tower bolt 150mm length in each shutter complete all as specified in SSR Part I fitted to chowkhats complete all as specified and as directed.
S & F 30 mm thick 2nd class hardwood moulded flush door with pre pressed lamination on both side, solid core construction 2 Nos door handle, 0.3 Nos butt hing of 100mm , 2 nos tower bolt 150mm length and 300 mm length sliding door bolt in each shutter complete all as specified in SSR Part I fitted to chowkhats complete all as specified and as directed.
S&F for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming Fe-410W(GdeE-250) quality B complete all as specified and as directed.
S&F for 1.25mm thick mild steel, plain, black sheet in hearths; covering to door shut ters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required complete all as specified and as directed.
S&F for 150 mm aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed.
S&F for 150 mm extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
S&F for 100mm long Butt hinges medium weight, cold rolled mild steel, and fixed complete all as specified and as directed.
S&F, for 300mm Mild steel , ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.
S&F for 300mm long aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and as directed.
M&L for 3mm thick sheet glass ordinary quality and glazing with oil putty in square n,exc 0.5Sqm in each pane complete all as specified and as directed.
S&F for stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staple/ wooden beads complete all as specified and as directed.
M&L for applying two coats of oil bound distemper over a coat of chalk whitening primer over 2mm thick wall care putty on newly plastered or un-plastered surfaces of walls including preparation complete all as specified and as directed.
M&L for applying two coats of oil bound distemper over a coat of birla wall care putty on old decorated surfaces of walls by complete removal of existing treatment including preparation complete all as specified and as directed.
M&L for applying two coats of synthetic enamel paint over a coat of pink primer on new wood or wood based materials of any description not other described over 10cm width or girth including preparation complete all as specified and as directed
Complete removal of existing surface and applying 2 coat of exterior emulsion paint over a coat of Primer on old decorated surfaces including preparation of surfaces complete all as specified and as directed.
S&F, for 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in walls complete all as specified and as directed.
S&F, for 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in walls complete all as specified and as directed.
S&F for 110mm bore PVC (SWR) bends ISI marked of any radius with access door complete all as specified and as directed.
S&F for 75mm bore PVC (SWR) bends ISI marked of any radius with access door complete all as specified and as directed.
S&F in repairs 110 mm bore PVC (SWR) junction single, (single T) equal or un equal complete all as specified and as directed
S&F in repairs 75 mm bore PVC (SWR) junction single, (single T) equal or un equal complete all as specified and as directed
S&F in repairs 110 mm bore PVC (SWR) vent cowl complete all as specified and as directed
M & L for 60 mm thick Machine pressed coloured precast concrete rubbber moulded interlocking paver block of any shape and size conforming to IS 15658-2006 of , M-35 Grade complete all as specified and as directed
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in copings, kerbs, and the like all incl necessary form work complete all as specified and as directed
M & L for 50 mm thick Sand filling below the interlocking paver block including watering and consolidation complete all as specified and as directed
M & L for 100mm thick Cement concrete type D-2, 1:4:8, using 40mm graded stone aggregate as in subbase complete all as specified and as directed.
M&L for glazed ceramic coloured tiles of size 450 x 300 x 6 to 7 mm,450x350 or 350x250 6 to 7mm thick on vertical surface such as skirting/dado etc. ,set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile with & including 10 mm thick rendering in cement mortar 1:4 finished rough to fix tiles complete all as specified and as directed
M&L for Virified Ceramic tiles dark shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM (1:6) complete all as specified and as directed.
M & L for Aluminium powder coated( minimum thickness of powder coating 50 micron) sliding windows(three track) of frame of size bottom section 92.00x31.75x1.50mm ( Section No 20832),Top and Sides of size ( Section No 20831) with anodised aluminium shutters Top and bottom size 40x18x1.55mm (section 20736) and sides ( handle) of size 40x18x1.55mm (section 20738) and lock side shutter frame size 40x18x1.45mm (section 20737) including rubber gasket,beading and locking arrangement , both glazed and gauzed with 5.0 mm thick glass, stainless steel wire cloth netting(0.36mm nominal dia and averege width of aperture 1.40mm), and fixed including necessary glazing clips, rubber packing, anodized aluminiunm snap beading screws and aluminium fittings of standred size complete all as specified and as directed. ( Notes : (i) Glazing and stainless steel wire cloth will not be measured and paid for separately
Surface excavation n.exc not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft /loose soil complete all as specified and as directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
M & L for 80 mm thick Machine pressed coloured precast concrete interlocking paver block any shape and size ( with grey cement and pigment) confirming to IS 15658-2006 of M-40 Grade complete all as specified and as directed.
M & L for Factory made precast cement concrete blocks made of 1:2:4 type B-1, using 20mm graded stone agg as in kerb stone chamfered and fixed in CM 1:6 complete all as specified and as directed.
S & F for Framed work such as Gate, grills, gratings, with ornamental & intricate design for spikes etc., with ends of bar shoulder &/or riveted, or forged into spikes; incl hinges & similar work conforming to Fe 290 GDE -E-165 complete all as specified and as directed.
M&L 15mm thick rendering on Fair Faces of Brick Walls or on Concrete Surfaces with water proofing compound in Cement Mortar 1:4 Finished fair and even complete all as specified and as directed. Note: WPC shall be measured and paid separately.
M&L for applying two coats of cement base paint over a coat of alkali resistant primer on newly plastered surfaces of walls including preparation and complete all as specified and as directed.
M&L for Hardcore of Broken stone or boulders gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M & L for 20mm thick granite (of any type) work Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
S&F for steel work in tubular trushes including special shaped washer etc complete using ERW or induction but welded tubes confirming to I.S. 1161-1979 grade St. 240 etc complete all as specified and as directed.
M&L for brick work using old size fly ash bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M&L for brick work using old size fly ash bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and as directed.
M&L for 100 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, as in floor for making good disturbed portion finished even and smooth without using extra cement including necessary form work complete all as specified and as directed.
S&F in replacement of sheet steel enclouser distribution boards, double door factory made VTPN 4 way 3 phase 415 volts 4 way with 200 amps rating copper bus bar and PVC insulated copper jumpers of suitable size from the MCCB to the out going circuits one incoming MCCB 160 amps and MCB TP 100 A -02 Nos,MCB SP 32 -08 Nos circuits comprising of 3 phase 4 wire of suitable rating complete all as specified and as directed.
Supply and fixing Single phase wall mounted remote controlled fan heavy duty AC 230 volts 400 mm sweep, metallic body complete including electric connection with twin core copper wire for wall mounted fan, nut, clamp & bolt etc complete all as specified and as directed.
M&L for Point wiring with PVC insulated 1.5 sq mm multi stranded copper conductor cable 1100 volts grade drawn into and including concealed PVC conduit not less than 20mm (ISI marked) including all fitting and fixing accessories including sunk in cast iron/pressed steel terminal boxes duly painted with two coats of antirorrrosive paint outside and two coats of aluminium paint inside, 2.8mm thick hylam brand laminated white bakelite sheet cover for mounting of switches, sockets, fan regulators etc and PVC insulated 1.5 Sqmm multistranded copper conductor cable as earth wire and making good the disturbed surfaces to match with the existing surfaces complete all as specified and as directed.
(a) One light /fan point controlled by one switch.
(b) One indepenmdent socket controlled by one switch.
S & F in repair for Switch piano flush type AC 230 volts 5 Amps single pole one way complete all as specified and as directed.
S & F in repair for Socket outlet 3 pin, 5 Amps and AC 230 volts flush type complete all as specified and directed by Engineer in charge
Description all as per item No 61 here in befor but with 1100 volts grade copper standard conductor cable of size 2.5Sqmm with 1.5Sqmm solid copper conductor PVC for 3 pin switch socket outlet15Amp independent board complete all as specified and as directed.
M&L for switch socket combination multipin 5 and 16 Amps AC 230 volts flush type complete all as specified and as directed.
Supply & Fixing in repair sheet metal enclosure MCB DB double door [Acrylic], single pole and neutral, 240 volts, 8 way with 200 Amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified and as directed.
Supply & Fixing in repair single pole and netural sheet metal enclosure with a two pin and earth plug and socket complete with 01 number single pole MCB 20 Amps complete all as specified & directed. Make:- Legrand/ havells or Equivalent
S & F for MCB Single pole and neutral rated capacity 40 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
M&L for Ceiling rose surface bakelite 65 mm x50 mm three terminal AC 230 volts flush type complete all as specified and as directed.
Taking down carefully any type point wiring (light, fan, socket bell or power) , complete with fitting such as switches ceiling roses,lamp holders sockets,regulators,call bell light fitting with PVC conduit surface /concealed or wooden pattens including sunken cast iron /pressed steel terminal boxes etc and making good the disturbed surfaces of walls, roof, floors etc to match with the existing surfaces complete all as specified and as directed.
Taking down carefully ceiling fan/Exhaust Fan of any sweep and size and depositing to MES store complete all as specified and as directed.
Taking down carefully Main switch and Distribution boards any make and size complete all as specified and as directed.
Supply & Fixing in repair Smart bright Batten Series, LED luminaire using LEDs 22 watt 110 LM/watt with diffuser which ensures uniform distribution and comfort batten series features latest LEDs and delivers consistent light output, stable color start Extruded Aluminum housing, Energy efficient, Flicker free start Inbuilt driver unit Suitable for wall and ceiling mounting using brackets (supplied along with The Luminaire has been tested as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Secl), report has established conformity of the product(s) to the requirements of the Standard/Specification complete all as specified and as directed.
Material & Labour for Sub main wiring with four single core PVC Insulated cable two run of size 4.0 Sqmm multi-strand copper conductor FRLS cable 1100 volts grade drawing into PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 4.0 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire including making good disturbed surface to match existing complete all as specified and as directed. Note : - two runs of 4.0 Sqmm & one run of 4.0 Sqmm cable shall be measured as one unit run.
Supply & fix in replacement of LED Security Light Luminaire 35 watt 6000K with .high power LED cool white,CRI 75,+/- 5% supply voltage 220/240/50 Hz, light engine driver base.pole adapter,powder coated pressure die cast aluminium with heat resistant toughened glass with lens. complete all as specified and as directed.
S & F in repair MCB single pole 240 volts 6 to 40 Amps, C Series complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
chandra builders (BID ID -3326389)
ANAMIKA CONSTRUCTION (BID ID -3335342)
Arpit dixit construction (BID ID -3335391)
Kirti Chandeliya and Assosicates (BID ID -3324882)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .