Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.5 LAccepted-AOC A 201 BHAWAN ESTATE OPP KAMAYANI HOSPITAL SIKANDRA AGRA U P 282007 | AGRA | AGRA | UTTAR PRADESH | 282007 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹49.3 L+₹26,423.50 (0.54%)Rejected-Finance DAULAT NAGAR SOHALLA ROAD AJIJPUR DHANOLI AGRA UP PIN 282001 | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-Finance Being higher bidder | |
| 3 | L3₹49.4 L+₹37,888 (0.77%)Rejected-Finance 60 310A 3 KHERIA MOD JAGNER ROAD AGRA 01 | AGRA | UTTAR PRADESH | 282001 | L3 | Rejected-Finance Being higher bidder |
| Sl No | Description | Qty | Unit | Jain prem construction L1 | rohan traders L3 | aman construction & general suppliers L2 |
|---|---|---|---|---|---|---|
| 1.00 | Surface Excavation not exceeding 30 Cm deep and averaging 15 Cm deep and getting out in Soft/ Loose soil all as specified and directed. | 934 | Sqm | 10 ₹9,340 Lowest | 14 ₹13,076 | 60 ₹56,040 |
| 2.00 | Dewatering/desludging of septic tanks, Grease trap etc of any depth, cleaning of all sludge, silt residue of both organic and inorganic nature by Mechanically means, using Hydraulic suction sewer cleaning machine having suitable tank capacity including skilled driver, operator & labour etc and disposal off the same out side the defence area all as directed by Engr-in-Charge.
Note - 1. After receiving complaint from MES Rep by Contractor's supervisor / Site Engineer, job to be completed within 12 working hours.
2. Debris and sludge etc taken out shall be measured in "cum" .The quantum of work done for payment purpose shall be the solid content of sludge or debris. Solid content shall be 50% of volume of loose sludge/debris containing sludge water.
3. In case contractor failed to rectify scheduled program a recovery of ₹1000/- per day shall be deducted from his payment. | 125 | Cum | 160 ₹20,000 Lowest | 290 ₹36,250 | 250 ₹31,250 |
| 3.00 | M&L for mechanically used water sucking hydraulic pressure machine(min 3000ltr capacity) for cleaning of blocked manholes/sewage line and disposed off the same out side the defence area all as specified & directed by Engineer-in-charge .
Note :- In case contractor failed to deploy the machine as per scheduled program a recovery of ₹1000/- per day shall be deducted from his payment. | 85 | Each Trip | 900 ₹76,500 | 500 ₹42,500 Lowest | 800 ₹68,000 |
| 4.00 | Cleaning of blockage from WCs/Gully trap/Nahani trap/Floor traps and vertiical pipes of any size by removing cover if required & refixing in position including removal of sludge & sediments from chamber & disposing it away from the domestic premises all as specified and directed.
Note :- Complaint shall be resolve with in 24 Hours from the date of notified to the contractor's rep, failing which a recovery of ₹1000/- per day shall be deducted from his payment. | 1,500 | Each Complaint | 25 ₹37,500 Lowest | 30 ₹45,000 | 35 ₹52,500 |
| 5.00 | Cleaning of chocked /blocked sewage lines of any bore pipe by rodding /mechanically means, taking out loose sedimented sand dirt, oil and grease, sludge water, rags, fibers or vegetation etc from any depth of sewage lines including removal of sludge/debris/building materials to a distance exc 250m but n.exc 500m and buried under ground complete all as specified and as directed.
Note:- All T&P if required are deemed to be included in the item rate. Complaint / blocked line to be cleared with in 24 Hours from the date of notified to the contractor's rep, failing which a recovery of ₹1000/- per day shall be deducted from his payment. | 1,500 | RM | 25 ₹37,500 Lowest | 40 ₹60,000 | 50 ₹75,000 |
| 6.00 | Demolition and breaking up drain pipes 150mm dia salt glazed stone ware/AC or reinforced concrete pipe set in cement mortar including removal from site complete all as specified and directed . | 50 | RM | 10 ₹500 Lowest | 20 ₹1,000 | 50 ₹2,500 |
| 7.00 | Demolition and breaking up drain pipes 200mm dia salt glazed stone ware/AC or reinforced concrete pipe set in cement mortar including removal from site complete all as specified and directed . | 75 | RM | 15 ₹1,125 Lowest | 30 ₹2,250 | 75 ₹5,625 |
| 8.00 | Excavation in trenches in soft / loose soil, not exc 1.5 m wide and not exc 1.5m depth for laying of cable, errection of poles, stay and pipe line etc and getting out, complete all as specified and directed by Engr-in-charge. | 145.8 | Cum | 200 ₹29,160 | 185 ₹26,973 | 135 ₹19,683 Lowest |
| 9.00 | Excavation in trenches in soft / loose soil, not exc 1.5 m wide and exc 1.5m but not exc 3.0m depth and getting out complete all as specified and directed by Engr-in-charge | 35 | Cum | 300 ₹10,500 | 220 ₹7,700 | 160 ₹5,600 Lowest |
| 10.00 | Demolition of brick masonry built in cement or cement or cement lime mortar complete all as specified and directed . | 20 | Cum | 150 ₹3,000 | 200 ₹4,000 | 100 ₹2,000 Lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
17 Dec 2025, 6:00 pmClosed
GE TECH AREA AGRA
Military Engineers Services Garrison Engineer (AF) Tech Area Agra - 282008
COMPREHENSIVE MAINTENANCE TO WSA AND NEAR BY BUILDINGS AND REPAIR TO SEWAGE LINE, CLEANING OF SEPTIC TANKS, MANHOLES, COVER SLABS AND OTHER RELATED MISC WORKS UNDER GE (AF) TECH AREA AT AF STN AGRA
2025_MES_730338_1
8200-1743/E8
Open Tender
Civil Works - Others
Item Rate
270 days
AF TECH ATREA AGRA
Class D and above category a(i)
8 documents required · 8 mandatory
₹500
Yes
GE TECH AREA AGRA
₹1 L
Yes
7 Feb 2026
24 Nov 2025
22 Dec 2025
24 Nov 2025
17 Dec 2025
10 Dec 2025
Amount
Surface Excavation not exceeding 30 Cm deep and averaging 15 Cm deep and getting out in Soft/ Loose soil all as specified and directed.
Dewatering/desludging of septic tanks, Grease trap etc of any depth, cleaning of all sludge, silt residue of both organic and inorganic nature by Mechanically means, using Hydraulic suction sewer cleaning machine having suitable tank capacity including skilled driver, operator & labour etc and disposal off the same out side the defence area all as directed by Engr-in-Charge. Note - 1. After receiving complaint from MES Rep by Contractor's supervisor / Site Engineer, job to be completed within 12 working hours. 2. Debris and sludge etc taken out shall be measured in "cum" .The quantum of work done for payment purpose shall be the solid content of sludge or debris. Solid content shall be 50% of volume of loose sludge/debris containing sludge water. 3. In case contractor failed to rectify scheduled program a recovery of ₹1000/- per day shall be deducted from his payment.
M&L for mechanically used water sucking hydraulic pressure machine(min 3000ltr capacity) for cleaning of blocked manholes/sewage line and disposed off the same out side the defence area all as specified & directed by Engineer-in-charge . Note :- In case contractor failed to deploy the machine as per scheduled program a recovery of ₹1000/- per day shall be deducted from his payment.
Cleaning of blockage from WCs/Gully trap/Nahani trap/Floor traps and vertiical pipes of any size by removing cover if required & refixing in position including removal of sludge & sediments from chamber & disposing it away from the domestic premises all as specified and directed. Note :- Complaint shall be resolve with in 24 Hours from the date of notified to the contractor's rep, failing which a recovery of ₹1000/- per day shall be deducted from his payment.
Cleaning of chocked /blocked sewage lines of any bore pipe by rodding /mechanically means, taking out loose sedimented sand dirt, oil and grease, sludge water, rags, fibers or vegetation etc from any depth of sewage lines including removal of sludge/debris/building materials to a distance exc 250m but n.exc 500m and buried under ground complete all as specified and as directed. Note:- All T&P if required are deemed to be included in the item rate. Complaint / blocked line to be cleared with in 24 Hours from the date of notified to the contractor's rep, failing which a recovery of ₹1000/- per day shall be deducted from his payment.
Demolition and breaking up drain pipes 150mm dia salt glazed stone ware/AC or reinforced concrete pipe set in cement mortar including removal from site complete all as specified and directed .
Demolition and breaking up drain pipes 200mm dia salt glazed stone ware/AC or reinforced concrete pipe set in cement mortar including removal from site complete all as specified and directed .
Excavation in trenches in soft / loose soil, not exc 1.5 m wide and not exc 1.5m depth for laying of cable, errection of poles, stay and pipe line etc and getting out, complete all as specified and directed by Engr-in-charge.
Excavation in trenches in soft / loose soil, not exc 1.5 m wide and exc 1.5m but not exc 3.0m depth and getting out complete all as specified and directed by Engr-in-charge
Demolition of brick masonry built in cement or cement or cement lime mortar complete all as specified and directed .
Demolition of cement concrete (unreinforced) in ground floors and pavings etc exc 15cm thick above or below ground level complete all as specified and directed .
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed .
M&L for brick work with sub class 'B' bricks, using old size bricks, straight or curved on plan exc 6M mean radius built in CM 1:4 complete all as specified and directed.
M&L for 15 mm thick cement plaster in cement mortar 1:4 on concrete or brick surface and finished even and fair without using extra cement mixed with and including water proofing compound (liquid type) @ 200ml per 50Kg of cement or as per manufacurer's instructions complete all as directed and specified.
M&L for 15 mm thick cement plaster in cement mortar 1:6 on concrete or brick surface and finished even and fair without using extra cement mixed with and including water proofing compound (liquid type) @ 200ml per 50Kg of cement or as per manufacurer's instructions complete all as directed and specified.
S&F for 150 mm dia reiforced concrete pipe, class NP-2, drain pipes laid in trenches and jointed with collars all as specified and directed.
S&F for 200 mm dia reiforced concrete pipe, class NP-2, drain pipes laid in trenches and jointed with collars all as specified and directed.
Removing excavated material to a distance n exc 100m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed
Returning, filling soft/loose soil in including spreading, leveling, watering and well ramming in layers not exc 25cm complete all as specified and directed
M&L cement concrete Type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) in kerb stone ,copings,, apex stones, , anchorage blocks, , etc.(of any section as directed), with plain fair faces, including chamfered weatherings, throating etc complete all as specified and as directed.
M&L in repair factory made perforated precast RCC drain cover 75mm thcik any size incl 1mm MS Sheet all around the cover (incl placing ) complete all as specified and directed
M&L in repair factory made perforated precast RCC Manhole cover 75mm thcik any size incl 1mm MS Sheet all around the cover (incl placing) complete all as specified and directed ..
Cutting into existing manholes for 150mm dia of pipe for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required complete all as specified and directed ..
Cutting into existing manholes for 200mm dia of pipe for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required complete all as specified and directed ..
M&L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth protection, path / hardstanding / subbase etc complete all as specified and directed .
M&L for 20-25mm plastic coated coloured chequred tiles of approved colour, area of each tiles exc. 0.05 Sqm but not exc 0.09 Sqm laid over and including screed bed or bedding layer of 20 mm thick in CM 1:6 and pointing with grey cement and pigment complete all as specified and as directed
M & L in repair for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement and pigment laid complete all as specified and directed.
M&L for bedded on sand cushioning of 40mm thick under floors or in foundations including watering and consolidation complete all as specified and directed.
S&F in repair PVC (SWR) pipes 110mm dia single socketed, in any length with rubber ring joints, fixed on walls or floors complete all as specified and as directed
S&F in repair PVC (SWR) plain bend 110 mm dia, of any radius with rubber ring joints, complete all as specified and as directed
S&F in repair PVC (SWR) pipes 160mm dia single socketed, in any length with rubber ring joints, fixed on walls or floors complete all as specified and as directed
S&F in repair PVC (SWR) plain bend 160 mm dia, of any radius with rubber ring joints, complete all as specified and as directed
S&F in repair vitreous china urinal full stall type flat back size of white with grating and union for discharge pipe including chromium plated water spreader, connection pipe and discharge down pipe complete all as specified and as directed
S&F vitreous china wash down water closet pan (padestal pattern) with seat cover plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device (excluding fixing bolts, flushing cistern and flush pipe) etc complete all as specified and as directed.
S&F vitreous china squatting pan ,Orrisa pattern size 680x470mm white, with integral foot rests (excluding fixing bolts, flushing cistern and flush pipe) etc complete all as specified and as directed.
S&F in repair vitreous china wash hand basin, white, (flat back or angle back type) of size 580x450 mm including supplied and fixing angle iron braket and CP Pillar tap fancy type 15 mm bore,CP waste coupling, PVC waste pipe 32 mm dia, and 01 No PVC connection 15 mm dia & 450 mm long complete all as specified and directed.
S&F in repair 32mm dia waste coupling of CP half of full threadel etc complete all as specified and directed.
S&F in repair grating round 140mm size of CP etc complete all as specified and directed.
S&F in repairs PVC connections 15mm size, 650mm long with PTMT nuts on both ends complete all as specified & directed.
S&F CP Jet spray heavy duty with PVC connection as in repair complete all as specified & directed.
S&F CP health faucet with 1.5 m PVC connection as in repairs complete all as specified & directed.
S&F in repair 10 ltr capacity PVC valve less, syphonic action type, flushing cistern, dual flush, top level, white with inlet, ball valve, float and handle incl bracket 32mm dia flush pipe etc complete all as specified & directed.
S&F 10 ltr capacity PVC valve less, syphonic action type, flushing cistern, dual flush, top level, white with inlet, ball valve, float and handle incl bracket 32mm dia flush pipe etc complete complete all as specified & directed.
S&F in repair Cast iron (spun pipe) soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls size of 100mm dia epoxy coated inside and outside with all necessary connected fittings complete all as specified and directed.
S&F in repair gratings of 125mm dia made of stainless steel with waste hole complete all as specified and directed
S&F in repair PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S&F in repair Chromium plated Health Faucet for bore size 15mm (flexible tube and hand shower) ,wall mounting type suitable for EWC; with CP nuts and washer incl square hook ABS , of length 900mm complete all as specified and directed.
S&F in repair 75mm dia PVC (SWR) pipes single socketed, in any length fixed to walls / floors or in trenches with and including stack clamps of suitable size complete all as specified and as directed
S & F in repairs bend suitable for 75mm dia PVC (SWR) pipe complete all as specified and as directed
Taking down GI pipe of any grade of 15mm bore including fittings complete all as specified and directed.
Taking down GI pipe of any grade of 20mm bore including fittings complete all as specified and directed.
S&F steel water tubing medium grade galvanized with all fittings and fixed complete to walls, ceilings or laid on floors, bore of tube 15mm complete all as specified and directed.
S&F steel water tubing medium grade galvanized with all fittings and fixed complete to walls, ceilings or laid on floors, bore of tube 20 mm complete all as specified and directed.
S&F in repair 15mm dia, stop valve fancy type, cast copper alloy, chromium plated ,screwed down high pressure, with crutch or butterfly handles for 15 mm bore pipe or for unions complete all as specified and directed.
S&F in repair CI brackets for WHB, of angle iron 35mm x 35mm x 5mm of required length with and including embedding in PCC 1:2:4 type B1 and two coats of painting with synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F mild steel joist channel ,angle or tee sections, fixed independently without connecting plates etc of grade fe-410-0 or fe 310-0.complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding and removing rubbish off the premises complete all as specified and as directed
M&L for 25 mm thick PCC 1:2:4, type B0 (using 12.5 mm graded stone aggregate) as in flooring in leveling course complete all as specified and as directed
M&L for Non skid, joint free (edge cut) coloured ceramic tiles 7 to 8 mm thick (Square / rectangular) polished area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors and vertical surfaces etc laid over with and including 15 mm thick screed bed or bedding layer in CM (1:6), set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete all as specified and as directed
M&L for factory made stone kerb of roughly squared stones of size 15cmx30cmx35cm, dressed so that the maximum depression from a straight edge held against the dressed surface shall not exceed 6mm for top and exposed surfaces of sides and 20mm for the rest of surfaces jointed in CM 1:6 and struck flush incl two coat of external emulsion paint over one coat of primer complete all as specified and directed
M&L for glazed ceramic coloured tiles 300x450x 7/350x250x7mm thick as in dado with and including 10mm thick rendering for bedding layer in CM (1:4), set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete all as specified and as directed
M&L for vitrified (edge cut) coloured ceramic tiles 8 to 10 mm thick (Square / rectangular) polished area of each tile not exceeding 0.36 sqm as in floors and vertical surfaces etc laid over with and including 15 mm thick screed bed or bedding layer in CM (1:6), set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete all as specified and as directed
M&L in repair On site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for 25 users conventional type complete all as specified and as directed
M&L for Concrete bed in PCC (1:4:8) type D-2 (using 40mm graded stone aggreagates) to drain pipes 150 mm incl packing under,and hunching against the sides after they are laid and tested complete all as specified and as directed
M&L for Concrete bed in PCC (1:4:8) type D-2 (using 40mm graded stone aggreagates) to drain pipes 200 mm incl packing under,and hunching against the sides after they are laid and tested complete all as specified and as directed
M&L for Cement concrete (1:3:6) type C2 (using 40mm graded stone aggregates) as in in foundations, filling and mass concrete / sub base of paving including joint cutting & filling with joint filler complete all as specified and directed .
M&L for Cement concrete (1:4:8) type D2 (using 40mm graded stone aggregates) as in in foundations, filling and mass concrete complete all as specified and directed .
M&L for 50 mm thick PCC 1:2:4 type B-0 ( using 12.5 mm graded stone aggregate as in sub base of flooe and finished the surface even and rough etc complete all as specified and directed .
M&L for 20-25mm thick machine cut kota stone flooring / skirting ,laid over and including cement screed base 15mm thick in CM 1:6 , laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L for anti termite treatment of soil under existing floors using emulsion @one litre per hole , 300mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified and as directed.
M&L for securing or easing of steel door with cleaning/greasing/oiling/ overoiling/welding in gear box, crank handle, rolling spring, channels, ball bearing, pully,Gate wheels, adjustment of lock device etc, & any description each complete all as specified and directed..
Taking down cement plaster in cement or cement lime mortar on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, and removal of debries to a distance exc 1.5 Km but not exc 5.0 Km complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar 1:4 on external wall on fair faces of brick work or concrete surfaces and finish the surface even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation of new surface of walls (external surfaces) and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) in normal pattern including filling of pot holes and cracks with putty, as per manufactures instructions etc complete all as specified and as directed.
M&L for preparation of old surface of walls (external surfaces) and Finishing walls with Acrylic Smooth exterior paint of required shade (Two coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) in Normal pattern, as per manufactures instructions, incl cleaning and ensure that the surface to be painted is free from any loose, dirt, cracks are to be filled with wall care putty or mixture of white cement and fine sand (in the ratio 1:3) complete all as specified and as directed.
M&L for preparation of old plastered surfaces of walls and applying two coats of distemper oil emulsion white or tinted with roller including filling of pot holes and cracks with putty, complete all as specified and directed.
Excavating in post holes (or similar holes) each n.exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25cm, watering, and removing surplus soil to a distance n.exc 50m and making good surface complete all as specified & directed by Engr-in-charge.
Dismantling posts or struts (wood, steel or R.C.C.) any section,embedded in concrete including taking out embedded portion and making good disturbed ground complete all as specified & directed by Engr-in-charge.
Dismantling chain link fencing wire mesh, of any type and size complete all as specified & directed by Engr-in-charge.
M&L for mild steel work as in posts or struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets (for securing wire mesh etc) including all necessary bolting or riveting and spot welding etc and similar work conforming to Fe-290 Gde E-165 complete all as directed by Engr-in-charge.
Supply only chain link fencing mild steel galvanised fencing any size and type (size of mesh and dia of wire as directed by Engr-in-charge) complete all as directed by Engr-in-charge.
Fixing only chain link fencing of any type fixed to RCC / steel post with mild steel flat & nut bolt etc,including necessary bolting complete all as directed by Engr-in-charge.
S&F in repair Galvanised, 2 strand, steel barbed wire 2.24 mm dia, barbed with 2 mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins, etc as directed (each line of wire to be measured) complete all as specified & directed by Engr-in-charge.
S&F in repair concertina coil 900 mm dia ( in stretched position), hot dip galvanised stee wire, coated with CLR anti corrosive paint, making diamond shape with the help of dove tail clips( 18 SWG), fixed to the MS angle iron/precast RCC fencing post with and including binding wire complete all as specified & directed by Engr-in-charge.
M&L for preparation of new surfaces of steel exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of zinc red oxide primer complete all as specified and as directed by Engineer-In-Charge.
M & L for prepararing old decorated steel surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as directed.
M&L ATT along the external wall below concrete or masonary apron using chemical emulsion @ 2.25 litres per linear meter including drilling and plughing holes etc in apron complete all as specified and as directed by Engineer-In-Charge.
M&L for cleaning of drain n.exc. 60 cm wide and n.exc 60cm in depth by removing deposited soft / loose soil, vegitation/grass and other foreign material and removal of excavated material to a distance exc 50 m but n.exc. 100 m and deposited wherever directed complete all as specified and directed by Engr-in-Charge.
Taking down existing door frame / shutters of area n. exc 60 Sqm with required tools & plant, without causing damage to other components of Bldg for repairing work and re-fixing the door shutters in same position after necessary repairs, oiling and Greasing complete all as specified and as directed. Note :- (a) Damages if any, caused due to poor workmanship shall be made good by the contractor at his own cost to match with the existing complete without any extra cost to the department.
S&F top/bottom wheel made up of taplon / cast iron wheel, including fixing only of ball bearings 02 Nos circlips, 01 No shaft of dia 25 mm x 120 mm long or size as per required at site , including necessry welding, drilling and other fittings etc all complete and all as specified and as directed.
Supply and fixing Ball bearing roller of make SKF of size 100 x 60 mm, or size as per site requirement complete all as specified and as directed..
Taking down carefully aluminium/copper point wiring (light/fan/socket or power) complete including fitting fixtures such as switches, socket, ceiling rose, brackets, holders, bulk head/tube light fitting etc. and removing materials from site and making good disturbed surface of walls/ floors etc. complete all as specified and directed
M&L Point wiring for One light/fan point controlled by one switch using approved colour coding as per IS, with Zero Halogen Flame retardant (HFFR), smoke free, non toxic, non corrosive installation cable with UNILAY construction copper conductor 1.5 Sq. mm (nominal area), single core, insulated and unsheathed stranded cable 1100 Volts grade ISI-694 marked TEC and FIA approved in & including heavy duty, electric resistance welded (ERW) stove enameled surface Steel mounted conduit, heavy duty ISI marked as per IS:9557 (Part I) 1980 including HFFR insulated unsheathed unitary construction copper conductor 1.5 Sq. mm nominal cross sectional area wire as earth continuity conductor up to common earth and connecting to earth dolly. All conduit accessories such as bends elbows Tee etc shall be Flame proof certified by CMRS Dhanbad complete all as specified and directed
M&L Point wiring for socket point using approved colour coding as per IS, with Zero Halogen Flame retardant (HFFR), smoke free, non toxic, non corrosive installation cable with UNILAY construction copper conductor 2.5 Sq. mm (nominal area), single core, insulated and unsheathed stranded cable 1100 Volts grade ISI-694 marked TEC and FIA approved in & including heavy duty, electric resistance welded (ERW) stove enameled surface Steel mounted conduit, heavy duty ISI marked as per IS:9557 (Part I) 1980 including HFFR insulated unsheathed unitary construction copper conductor 2.5 Sq. mm nominal cross sectional area wire as earth continuity conductor up to common earth and connecting to earth dolly. All conduit accessories such as bends elbows Tee etc shall be Flame proof certified by CMRS Dhanbad complete all as specified and directed
M&L for flame proof switch socket & plug combined point controlled by single pole one way 16 Amp ON-OFF rotary switch. Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified and directed.
S&F in repair flame proof weather rotary switch with cable terminal box in cat aluminum alloy ( LM-6) construction, epoxy powder coated, single pole 16 Amp ON/OFF type, 230 V AC, certified by CMRS for Group IIA & IIB complete including compression glands all as specified and directed.
S&F in repair flameproof tube light fitting CIMFR certified LED flameproof batten suitable for single T8 tube of 16W/20W. Recommended for Gas/Vapour group of IIA & llB and Zone 1 & 2 .IP65 Protected LED flameproof made of aluminium alloy LM6 etc. complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make- Crompton/ Sudhir/Baliga
S&F in repair MCB, SP, AC, 240 volts of 06 to 32 Amps capacity "C" series and making connections complete all as specified and directed.
S&F in repair isolator, SPN, AC, 240 volts of 6-32 Amps for inductive load connected through cable lugs of suitable size, complete all as specified and directed.
Disconnection and taking down any type any watt tube light fitting from wall/ceiling for cleaning & repair including replacement of worn out parts to make it fully functional and re-fixing on existing location complete all as specified and as directed. Note : Parts will be measured and paid separately as supply only under respective items of BOQ .
Supply only, 20 W , Photon ultra plus LED tube light rod with new Ultra bright LED polycarbonate tubelight with <10% THD with very high efficacy suited for installation in existing old serviceable T8 tube light batten fitting with G13 lamp holders and making electric connection complete all as specified and directed. Make- orient/Jaquar/Crompton
S&F in repair LED street/security light fitting of 60 Watt complete with new generation energy saving and environmental friendly long life versatile pressure die-cast aluminium IP 66 roadway luminarise with high power LEDs, fixed on walls with and including FI clamps , GI Pipe 40 mm dia, 1.5 mtr long in shape complete all as specified and directed. Make- orient/Jaquar/Crompton
S&F in repair of Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed.
S&F in repair of Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled screwed including 3 Nos, 8mm dia, 25mm long hex head screw complete all as specified and directed.
S&F in repair of Copper strip 20 x 3 mm with DMC type saddles/insulators or as earthing electrode and fixing screws etc. complete all as specified and directed.
S&F in repair of galvanised strip 25 x 4 mm with DMC type saddles/insulators or as earthing electrode and fixing screws etc. complete all as specified and directed.
S&F in repair of aluminum strip 25 x 3 mm with DMC type saddles/insulators on roof/wall and connecting to test point etc all as specified and directed.
Removal of surplus excavated soil to a distance n. exc 50 m above the starting point complete all as specified and as directed.
Supply and Laying double walled corrugated (DWC) HDPE duct pipe in 6 mtr lenght conforming toIS 16205 Pt-24 of approved color complete with fittings for cable protection of size 50mm outer dia and 38mm inner dia Make:- Astral/ Universal/ Dutron/SFMC as approved by GE.
Taking down and relaying serviceable XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of sizes 10 to 16 sqmm 3.5/4 core laid in trenches or fixed on walls/floor/pole complete all as specified and as directed.
Supply and laying in repair XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 10 sq mm, 4 core in trenches or fixed on wall/floor/poles complete all as specified and directed.
Supply and laying in repair XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 16sq mm, 4 core in trenches or fixed on wall/floor/poles complete all as specified and directed.
S&F in repair Weather Proof thermo plastic (Polysterene) Cable Junction box with 4 aluminium strip bar (25x3 mm) , having protection class IP-65 and of overall size not less than 205mm x 255mm x 112mm having metric knockouts on the wall, duly fixed with the pole with clamp, GI bolts, nuts, washers and 2 Nos polymide weather proof cable glands (Complete with check nut) and including 1 No. 6 Amps SP MCB. Make of Box :havells/sintex Equivallent in SPELSBERG / RITTAL
Preparation of old painted surface of steel tubular poles of 9 mtr long including cross arms, cable protection pipe, bus bar box and painting of complete area with one coat of aluminium paint from 1.5 mtr above ground level to top of pole and making alternate strips/layers (30 cm wide) with white and blue synthetic enamel paint upto the 1.50 meter height from the ground level including writing the pole number in white letters on black background and cleaning/cutting the grass/bushes at a radius of 2 mtr surrounding the pole complete all as specified and directed.
Supply and fixing in repair 2 core, 2.5 Sqmm PVC insulated heavy duty electric cable unarmoured with stranded aluminium conductor complete all as specified and directed .
Supply & fixing pvc knobs compatible with existing flame proof switchs complete all as specified and directed .
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground vertically at a depth not less than 2.25 metre below normal grond level with top edge of eath plate at a depth not less than 1.5 metre below normal ground level, earth plate surronded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron strip of 25 x 4 mm as earthing lead (upto the body of the equipment) by means of bolts, nuts check nuts and washers made of galvanised iron and connected to main switch board or main control board or equipment with testing point to check the earthing values and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, and PCC chamber pit with PCC (1:3:6) Type C-1 using 20mm graded stone aggregate, 40cm x 40cmx40mm thick well dressed jodhpur stone by holing at middle including MS handle of made by 10mmdia MS rod, including excavation and earth work in any type of soil returning filling and disposal of surplus soil to a distance not exceeding 50m. all as specified and shown in electrical plate No 3 of SSR 2009 (Part-1) complete all as specified and as directed by Engineer-in-charge.
aman construction & general suppliers (BID ID -3500330)
rohan traders (BID ID -3512663)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
1743tENDER.pdf
Tender Documents • 1.70 MB
BOQ_830132.xls
BOQ • 5.87 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .