Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 LAccepted-AOC | L1 | Accepted-AOC successful bidder | |
| 2 | L2₹13.3 L+₹80,441 (6.44%)Rejected-AOC | L2 | Rejected-AOC unsuccessful bidder | |
| 3 | L3₹13.3 L+₹86,550 (6.93%)Rejected-AOC 306 BAKSHI HOUSE 40 41 NEHRU PLACE NEW DELHI 110019 DELHI | SOUTH EAST | DELHI | 110019 | L3 | Rejected-AOC unsuccessful bidder | |
| 4 | L4₹13.6 L+₹1.1 L (8.84%)Rejected-AOC 2 65 GORWA UDAYPARK SOCIETY REFINERY ROAD VILLAGE TOWN VADODARA CITY VADODARA VADODARA GUJARAT 390016 INDIA | VADODARA | GUJARAT | 390016 | L4 | Rejected-AOC unsuccessful bidder | |
| 5 | L5₹14.8 L+₹2.3 L (18.6%)Rejected-AOC | L5 | Rejected-AOC unsuccessful bidder |
Tender Value
Refer Docs
EMD Value
₹27,964
Closing Date
21 Dec 2020, 6:00 pmClosed
AGM(E-E), Juhu Airport, Mumbai-56
AGM(E-E), Juhu Airport, Mumbai-56
SITC of Split Ac At Juhu Airport Mumbai.
2020_AAI_64033_1
AAI/WR/AGM(E-E)/JUHU/08/20-21
Open Tender
Electrical Works
Item Rate
60 days
Juhu Airport, Mumbai-56
as per NIT
2 documents required · 2 mandatory
₹1,120
₹27,964
18 Jan 2021
9 Dec 2020
23 Dec 2020
9 Dec 2020
21 Dec 2020
9 Dec 2020
9 Dec 2020 - 17 Dec 2020
Amount
Supply of 1.5TR Inverter type Split Air-Conditioner of BEE 5 Star rating Hi-wall split 1.5 Ton non ductible fan coil unit (Indoor Unit), Copper Condensing unit (Outdoor Unit) with fan and High Energy Efficiency Ratio Rotary compressor, with cord less remote controller and works with R410A/R32/R 134A gas, suitable for operation on 1 Phase, 230 +/- 10%V, 50Hz AC supply etc. complete as required. The supply of unit shall include the copper pipings, Interconnecting Power cables between the Indoor and Outdoor Unit as per the standard manufacturer design (i.e. Copper pipings of not less than 3 Mtrs) including drain pipe and initial charge of gas etc. complete as required.
Supply of 2.0TR Inverter type Split Air-Conditioner of BEE 3 Star rating Hi-wall split 2.0 Ton non ductible fan coil unit (Indoor Unit), Copper Condensing unit (Outdoor Unit) with fan and High Energy Efficiency Ratio Rotary compressor, with cord less remote controller and works with R410A/R32/R 134A gas, suitable for operation on 1 Phase, 230 +/- 10%V, 50Hz AC Supply etc. complete as required. The supply of unit shall include the copper pipings, Interconnecting Power cables between the Indoor and Outdoor Unit as per the standard manufacturer design (i.e. Copper pipings of not less than 3 Mtrs) including drain pipe and initial charge of gas etc. complete as required.
Installation, Testing and commissioning of 1.5/2.0 TR wall mounted/Hi-wall type Split Air-Conditioner by making required structures of suitable size MS stand/PCC work as per site requirement i/c balancing of Liquid & Gas, Gas charging the system with R410A/R32/R 134A refrigerent if any extra gas required due to increase in length of Copper piping, including covering the Copper piping (i/c Copper pipe came along with the units) with suitable size casing capping/PVC pipe Lifting / Shifting of Outdoor & Indoor units upto site location etc., complete as required.
Supply, Laying and connecting of OEM recommended copper refrigerent Piping(Liquid and Gas) with Nitrile Rubber insulation of thickness not less than 13mm and with all other accessories suitable for 1 phase, 1.5TR split AC including covering the Copper piping with suitable size casing capping/PVC pipe etc. complete as required (Length of Liquid and gas line will be measured as single measurement).
Supply, Laying and connecting of OEM recommended copper refrigerent Piping(Liquid and Gas) with Nitrile Rubber insulation of thickness not less than 13mm and with all other accessories suitable for 1 phase, 2.0TR split AC including covering the Copper piping with suitable size casing capping/PVC pipe etc. complete as required (Length of Liquid and gas line will be measured as single measurement).
Supply and laying/fixing of ISI marked UPVC pipe of 20mm dia with required bends / connectors on surface/suspension for draining out the water including interconnection of drain pipe etc. complete as required.
Supply, Laying and connecting of unarmoured multi core copper conductor control cable of size not less than 3x2.5Sq.mm as per the site requirement etc., complete as required.
Supply and laying of PVC insulated and FR PVC round sheathed 4C X 4 Sq. MM muti core Copper Conductor unarmoured cable of 1.1 KV grade confirming to IS:694 with upto date amendments on surface, cable tray, trech etc. complete as required.
Supply and laying of PVC insulated and FR PVC round sheathed 3C X 4 Sq. MM muti core Copper Conductor unarmoured cable of 1.1 KV grade confirming to IS:694 with upto date amendments on surface, cable tray, trech etc. complete as required.
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commisioning etc. as required
Dismantaling of Split type Airconditioners of capacity of 1.5 TR / 2.0 TR. & shifting the same to AAI Stores as directed by Engineer -in-Charge.
SITC of Dehumidifier with Extraction capacity 60 ltr/24hr( 30C, 80% RH), Coverage for dehumidification upto 7000 cu.ft. , Suitable for operation on power supply 220V-240V/50Hz , Air Flow 360 cum/hr, with Programmable Timer, Electronic Humidity Setting ,Auto Restart/Resume etc. as required (Make :- Origin Novita Model: O60 or Equivalent. )
Anshutech Airconditioning Pvt Ltd
VOLKS ENERGIE PVT LTD
Techno Electricals
New National Airconditioning Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .