| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 LAdmitted-Finance | ₹5.5 L | L1 | Admitted-Finance |
| 2 | L2₹5.8 L+₹30,583 (5.59%)Admitted-Finance | ₹5.8 L+₹30,583 (5.59%) | L2 | Admitted-Finance |
| 3 | L3₹6.0 L+₹49,053 (8.97%)Admitted-Finance | ₹6.0 L+₹49,053 (8.97%) | L3 | Admitted-Finance |
| 4 | L4₹6.2 L+₹77,004 (14.1%)Admitted-Finance CW 545 SANJAY GANDHI TRANSPORT NAGAR NEW DELHI 110042 | NORTH | DELHI | 110042 | ₹6.2 L+₹77,004 (14.1%) | L4 | Admitted-Finance |
| 5 | L5₹6.4 L+₹93,685 (17.1%)Admitted-Finance | ₹6.4 L+₹93,685 (17.1%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Premier Engineering Company L6 | HYDROCON ENGINEERS L5 | RISHABH ENGINEERS L1 | Devraj Enterprises L4 | N.K. BUILDCOM L3 | Gupta Brothers L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.01 | Wiring of light point /fan point/ exhaust fan point /call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc. as required. (DSR No. 1.10.3 Group C) | 100 | Point | 1,14,400 ₹1,14,400 | 1,180 ₹1,180 Lowest | 61,000 ₹61,000 | 1,05,000 ₹1,05,000 | 70,000 ₹70,000 | 55,000 ₹55,000 |
| 1.02 | Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. (DSR No. 1.32) | 40 | Each | 18,400 ₹18,400 | 472 ₹472 Lowest | 16,400 ₹16,400 | 8,400 ₹8,400 | 20,000 ₹20,000 | 20,000 ₹20,000 |
| 1.03 | Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 in 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. (DSR No. 1.31) | 30 | Each | 11,100 ₹11,100 | 354 ₹354 Lowest | 9,300 ₹9,300 | 8,400 ₹8,400 | 15,000 ₹15,000 | 18,000 ₹18,000 |
| 1.04 | Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2x2.5 sq. mm +1x2.5 sq. mm earth wire. ( DSR No. 1.14.2) | 350 | mtrs | 69,300 ₹69,300 | 2,065 ₹2,065 Lowest | 38,500 ₹38,500 | 49,000 ₹49,000 | 52,500 ₹52,500 | 52,500 ₹52,500 |
| 1.05 | Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2X4 sq. mm +1x4 sq. mm earth wire .(DSR No.1.14.3) | 350 | mtrs | 91,700 ₹91,700 | 2,065 ₹2,065 Lowest | 70,000 ₹70,000 | 64,750 ₹64,750 | 70,000 ₹70,000 | 70,000 ₹70,000 |
| 1.06 | Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2X6 sq. mm +1x6 sq. mm earth wire .(DSR No.1.14.4) | 200 | mtrs | 70,000 ₹70,000 | 1,180 ₹1,180 Lowest | 58,000 ₹58,000 | 50,000 ₹50,000 | 50,000 ₹50,000 | 50,000 ₹50,000 |
| 1.07 | Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 4x10 sq. mm +2x6 sq. mm earth wire. (DSR No. 1.14.10) | 100 | mtrs | 78,300 ₹78,300 | 590 ₹590 Lowest | 47,000 ₹47,000 | 61,000 ₹61,000 | 30,000 ₹30,000 | 45,000 ₹45,000 |
| 1.08 | Supply and fixing call bell/ buzzer suitable for single phase 230V, complete as required.(DSR No.1.38) | 5 | Each | 525 ₹525 | 59 ₹59 Lowest | 950 ₹950 | 1,200 ₹1,200 | 750 ₹750 | 1,500 ₹1,500 |
| 1.09 | Supply and fixing 6 way(4+18), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnetions , powder painted including earthing etc. as required. (DSR No. 2.4.2) | 2 | Each | 7,000 ₹7,000 | 1,180 ₹1,180 Lowest | 5,900 ₹5,900 | 5,700 ₹5,700 | 2,000 ₹2,000 | 6,000 ₹6,000 |
| 1.10 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. - Single pole -(DSR No. 2.10.1) | 40 | Each | 7,920 ₹7,920 | 2,360 ₹2,360 Lowest | 7,600 ₹7,600 | 20,400 ₹20,400 | 8,000 ₹8,000 | 8,000 ₹8,000 |
Tender Value
Refer Docs
EMD Value
₹19,200
Closing Date
16 Jul 2026, 3:00 pmClosed
EE(EnM)M-5
EE(EnM)M-5
Renovation of illumination and electric system at Gulabi Bagh Water Emergency.
2026_DJB_295202_1
NIT NO-07 (2026-2027) EE(EnM)M-5
Open Tender
Miscellaneous Works
Item Wise
15 days
EE(EnM)M-5
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
THROUGH DJB OFFICIAL WEBSITE IN LINK TENDER
₹19,200
Yes
25 Jul 2026
10 Jul 2026
16 Jul 2026
10 Jul 2026
16 Jul 2026
10 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Wiring of light point /fan point/ exhaust fan point /call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc. as required. (DSR No. 1.10.3 Group C) | 100 | Point | - | - |
| 1.02 | Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. (DSR No. 1.32) | 40 | Each | - | - |
| 1.03 | Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 in 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. (DSR No. 1.31) | 30 | Each | - | - |
| 1.04 | Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2x2.5 sq. mm +1x2.5 sq. mm earth wire. ( DSR No. 1.14.2) | 350 | mtrs | - | - |
| 1.05 | Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2X4 sq. mm +1x4 sq. mm earth wire .(DSR No.1.14.3) | 350 | mtrs | - | - |
| 1.06 | Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2X6 sq. mm +1x6 sq. mm earth wire .(DSR No.1.14.4) | 200 | mtrs | - | - |
| 1.07 | Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 4x10 sq. mm +2x6 sq. mm earth wire. (DSR No. 1.14.10) | 100 | mtrs | - | - |
| 1.08 | Supply and fixing call bell/ buzzer suitable for single phase 230V, complete as required.(DSR No.1.38) | 5 | Each | - | - |
| 1.09 | Supply and fixing 6 way(4+18), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnetions , powder painted including earthing etc. as required. (DSR No. 2.4.2) | 2 | Each | - | - |
| 1.1 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. - Single pole -(DSR No. 2.10.1) | 40 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.07 MB
BOQ_392760.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .