Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.5 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹12.2 L+₹3.5 L (40.1%)Rejected-AOC | L2 | Rejected-AOC Not Accepted | |
| 3 | L3₹12.8 L+₹4.1 L (47.0%)Rejected-AOC SHOP NO 12 KHOPKAR APARTMENT KUMBHARAWADA URAN DISTT RAIGAD 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | L3 | Rejected-AOC Not Accepted |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
15 Mar 2024, 6:00 pmClosed
Garrison Engineer North Mumbai
Garrison Engineer North Mumbai Military Engineer Services Santacruz East, Mumbai 400029
REPAIR MAINTENANCE OF INTERNAL ELECTRIFICATION AT OTM AND MD ACCN AT DGQA GHATKOPAR AND VIKHROLI UNDER GE (N) MUMBAI
2024_MES_642729_1
8182/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer North Mumbai
As per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer North Mumbai
₹30,000
Yes
29 Mar 2024
16 Feb 2024
18 Mar 2024
16 Feb 2024
15 Mar 2024
2 Mar 2024
17 Feb 2024 - 22 Feb 2024
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials out side MD land after Credit for the same is recovered by the dept and making good disturbed surfaces of walls, floors, etc., all as specified and as directed.
Material and labour for Sub main wiring complete with and including 2 runs of 6 sqmm single core FRLS PVC insulated and unsheathed multi stranded copper conductor cable single core 1100 Volts grade drawn through and including PVC FR heavy duty conduit 25mm dia including accessories and fixed on walls and 6 sqmm FRLS PVC multi stranded copper conductor cable for earthing and connected to common earth dolly for housing the wires from main DB to SPN DB including cutting chases & making good disturbed surfaces of walls, taking down the existing sub main wiring etc complete all as specified and as directed by Engineer-in-Charge. Note :(a)Two runs of 6 sqmm PVC insulated cable and one run of 6 sqmm cable and one run of PVC conduit shall be measured as one unit length. (b) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. Make: ANCHOR/HAVELLS/POLYCAB Make of PVC conduit-Anchor, Modi, Pressfit, Precision, Astral, Panasonic Anchor, Polycab, Presto Plast, Supreme
Material and labour for Sub main wiring complete with and including 2 runs of 4 sqmm single core FRLS PVC insulated and unsheathed multi stranded copper conductor cable single core 1100 Volts grade drawn through and including PVC FR heavy duty conduit 25mm dia including accessories and fixed on walls and 4 sqmm FRLS PVC multi stranded copper conductor cable for earthing and connected to common earth dolly for housing the wires from main DB to SPN DB including cutting chases & making good disturbed surfaces of walls, taking down the existing sub main wiring etc complete all as specified and as directed by Engineer-in-Charge. Note :(a)Two runs of 4 sqmm PVC insulated cable and one run of 4 sqmm cable and one run of PVC conduit shall be measured as one unit length. (b) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. Make: ANCHOR/HAVELLS/POLYCAB/Plaza Make of PVC conduit-Anchor, Modi, Pressfit, Precision, Astral, Panasonic Anchor, Polycab, Presto Plast, Supreme
Material and labour for Point wiring for complete with PVC insulated FRLSH cable 1100 volts grade with multi stranded copper conductor conforming to IS-694, 1.5 sqmm (nominal area) drawn through and including non metallic PVC casing / capping (not less than 20mm wide) (ISI marked) and accessories on surface of wall/roof, including provision of PVC insulated FRLSH cable 1100 volts grade with multi stranded copper conductor 1.5 sqmm as earth continuity conductor and connecting to common earth dolly for one light / exhaust fan/ wall fan point controlled by one switch complete all as specified and as directed by Engineer-in-Charge. Make of Cable- Anchor/ havells/finolex /Polycab/Plaza of ISI mark as approved by GE Make of PVC Casing Capping-Anchor, Modi, Pressfit, Precision, Astral, Panasonic Anchor, Polycab, Presto Plast, Supreme
All as per item No.4 here-in before but for one bell point controlled by one bell push
All as per item No.4 here-in before but for one ceiling fan point controlled by one switch & regulator
All as per item No.4 here-in before but for One light point controlled by two, two way switch
All as per item No.4 here-in before but One 3 pin, 5/6 Amps socket point on the independent board controlled by one switch.
All as per item No.4 here-in before but for one 3 pin, 5/6 Amps socket point on same board with other switches controlled by one switch.
All as per item No.4 here-in before but for 3 pin 15/16 Amps switch socket combination on independent board with 2.5sqmm copper cable and provision of 2.5sqmm PVC insulated FRLSH cable 1100 volts grade with multi stranded copper conductor for earth continuity conductor connected to common earth dolly connecting up to fittings complete all as specified and as directed by Engineer-in-Charge.
Material and labour for point wiring with proper colour coding complete with and including PVC insulated unsheathed, flexible bright annealed multi stranded copper conductor single core FRLSH cable 1.5 Sqmm, 1100 volt grade confirming to IS 694, drawn through in and including (heavy grade) rigid non metallic PVC conduit pipe 25 mm size ISI marked with conduit accessories / fittings / junction box / inspection covers etc of ISI marked and cutting chases for concealed conduit with all surfaces by means of screws and sunk / cup washers, with sunken type terminal boxes made out of 3mm thick PVC sheet and 3mm thick laminated sheet cover for housing switches, socket outlets, regulators etc including 1.5 sqmm 1100 volts grade PVC insulated FRLSH unsheathed flexible, multi stranded copper conductor cable (green colour) as continuous earthwire connected to metallic bodies of luminaries / fans etc at one end and to common earth dolly at other end for one light / Fan / Exhaust fan / ceiling fitting point controlled by one, one way switch complete all as specified and as directed Make of Cable- Anchor/ havells/finolex /Polycab/Plaza of ISI mark as approved by GE Make of PVC conduit-Anchor, Modi, Pressfit, Precision, Astral, Panasonic Anchor, Polycab, Presto Plast, Supreme
All as per item No.11 here-in before but One 3 pin, 5/6 Amps socket point on the independent board controlled by one switch.
All as per item No.11 here-in before but for one 3 pin, 5/6 Amps socket point on same board with other switches controlled by one switch.
All as per item No.11 here-in before but for one bell/buzzer point controlled by one push button on same board with other switches controlled by one switch or independent board controlled by one switch..
All as per item No.11 here-in before but for 3 pin 15/16 Amps switch socket outlet, on independent board with 2.5sqmm copper cable and provision of 2.5sqmm PVC insulated FRLSH cable 1100 volts grade with multi stranded copper conductor for earth continuity conductor connected to common earth dolly connecting up to fittings complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs Switch Piano, flush type, single pole, one way, 5 Amps, 240 volts, ISI marked complete all as specified and as directed by Engineer-in-Charge. Make: Anchor / Legrand / Havells/.Crabtree/Leader
Supply and fix in repairs Switch bell push, flush type, single pole, one way, 5 Amps, 240 volts, ISI marked complete all as specified and as directed. Make: Anchor / Legrand / Havells/.Crabtree/Leader
Supply and fix in repairs switch socket outlet, combination 2 in 1, 3/5 Pin, 5 Amps, flush type, universal ISI marked complete all as specified and as directed by Engineer-in-Charge. Make: Anchor / Legrand / Havells/.Crabtree/Leader
Supply and fix in repairs switch socket outlet, combination 5 in 1, 3 Pin, 5/15 Amps, flush type, universal ISI marked complete all as specified and as directed by Engineer-in-Charge. Make: Anchor / Legrand / Havells/.Crabtree/Leader
Supply and fix in repairs stepped type electronic fan regulator on existing phenolic laminated sheet,100W, 230 V etc complete all as specified and as directed by Engineer-in-Charge. Make: Anchor / Legrand / Havells/.Crabtree/Leader
Supply and fix in repairs modular switch,one way 10 amps, one module complete all as specified and directed by Engineer-in-charge. Make:Anchor / Legrand / Havells/.Crabtree/Leader
Supply and fix in repairs modular socket outlet,2/3 pin 06 amps, two module complete all as specified and directed by Engineer-in-charge. Make:Anchor / Legrand / Havells/.Crabtree/Leader
Supply and fix in repairs modular switch,one way 16 amps, one module complete all as specified and directed by Engineer-in-charge. Make:Anchor / Legrand / Havells/.Crabtree/Leader
Supply and fix in repairs modular socket outlet,2/3 pin 06/16 amps, two module complete all as specified and directed by Engineer-in-Charge.. Make:Anchor / Legrand / Havells/.Crabtree/Leader
Supply and fix in repairs Ceiling rose, PVC/polycarbonate body, three terminal 28x50mm, ISI marked complete all as specified and as directed by Engineer-in-Charge. Make: Anchor / Legrand / Havells/.Crabtree/Leader
Supply and fix in repairs modular type stepped fan regulator,120w, 2 module complete all as specified as directed by Engineer-in-Charge. Make:Anchor / Legrand / Havells/.Crabtree/Leader
Supply and fix in repairs holder, PVC/Polycarbonate type complete all as specified and as directed by Engineer-in-Charge. Make: Anchor / Legrand / Havells/.Crabtree/Leader
Supply and fix in repairs B22 base 09 Watt, 6500K , white, LED bulb in the lamp holder complete all as specified and as directed by Engineer-in-Charge. Make: Anchor / Legrand / Havells/.Crabtree/Leader
Supply and fix in repairs Call bell electric (Ding Dong type) suitable for working on 230 volts AC supply multi music type complete all as specified and as directed. Make: Anchor / Legrand / Havells/.Crabtree/Leader
Supply and fix in repairs surface mounted 22 watts LED tube light fitting, ultra slim square profile LED lighting fixture with extruded aluminium, energy efficient light fitting and connecting up with copper 3 core flexible cord of minimum size 0.5 sqmm complete all as specified and as directed by Engineer-in-Charge. Make:- Philips model no BN021C LED22S PSU CW GR or equivalent in Havells/CG
Supply and fix in repairs surface mounted 12 watts LED tube light fitting, ultra slim square profile LED lighting fixture with extruded aluminium, energy efficient light fitting and connecting up with copper 3 core flexible cord of minimum size 0.5 sqmm complete all as specified and as directed by Engineer-in-Charge. Make:- Philips model no BN 021 LED12S 6500 PSU GR or equivalent in Havells/CG
Supply and fix in repairs 3 feet, 6500K surface mounted, 20 watts motion sensor LED tube light fitting, detects movement within 10feet in garage/staircase/balcony/parking & not less than 900 lumens brightness and connecting up with copper 3 core flexible cord of minimum size 0.5 sqmm complete all as specified and as directed by Engineer-in-Charge. Make:- Philips model no PHI-BATTEN-RADAR-20W or equivalent in Havells/CG/Bajaj
Supply and fix in repairs 16 Watt, wall light, 6500K, LED fitting for better apprearance in bathrooms & mirrrors and connecting up with copper 3 core flexible cord of minimum size 0.5 sqmm complete all as specified and as directed by Engineer-in-Charge. Make:- Philips model no Megatron 16W or equivalent in Havells/Bajaj
Supply and fix in repairs 3 feet, 6500K surface mounted, 20 watts rechargable invertor LED batten with automatic DC mode feature on power failure and connecting up with copper 3 core flexible cord of minimum size 0.5 sqmm complete all as specified and as directed by Engineer-in-Charge. Make:- Philips Invertor Batten/ Havells/CG/Bajaj
Supply and fix in repairs recess mounted LED ceiling light fitting, 600mmx600mm 36W, 230V, 50Hz complete with all accessories internally pre wired and including connecting up with twin core twiated flexible copper conductor cable fixed on the false ceilling with neccessory cutting of false ceilling wherever neccessary screws/fastners etc complete all as specified and directed by Engineer-in-Charge-in-Charge, Make : Philips model no RC370B LED 36S or equivalent in Havells/CG/Bajaj
Supply and fix in repairs decorative wall mounting fitting, in durable plastic body & designer mesh in gold finish suitable for 9 W LED lamp working on 240 volts, 50 hz AC including LED bulb of capacity 9 watt complete all as specified and directed by Engineer-in-Charge. Make for fitting : Havells cat part No LHFOECE1TZB014 or equivalent in Wipro/ Havells sample as approved by GE, Make for Bulb :Havells cat part No LHLDEUEEMC8R009 or equivalent in Wipro/ Havells sample as approved by GE.
Supply and fix in repairs LED 18 Watt ftiting, cirular type, surface mounted LED downlighter with white powder coated, aluminium housing with integrated electronic driver of same make and connecting up with three core copper flexible cable 16/0.20mm with fixing accessories complete all as specified and as directed by Engineer-in-Charge. Make: Havells ENDURANEOHESURFACEDLS18WLED 840S or equivalent in Wipro/ Philips sample as approved by GE.
Supply and fix in repairs LED fitting, 20 Watt, square type, recess mounted, to be fitted in False ceiling and connecting up with three core copper flexible cable 16/0.20mm with fixing accessories complete all as specified and as directed by Engineer-in-Charge Make: Wipro cat no.D722060 or equivalent in Philips/ Havells sample as approved by GE.
Supply and fix in repairs LED building security light fitting 45 Watt, luminaire fixture in IP 66 protection level output of LED lamp efficiency minium 100 luman per watt after all losses , pressure die-cast aluminium housing LED Street light complete with GI clamp including connected accessories and bracket made of GI Pipe 50mm dia light grade 1.25 m long, bend to shape with two sets of MS flat iron clamps, nuts, bolts, washers etc. complete all as directed by Engineer-in-Charge. Make Philips : cat pat No BRP409 LED060HENRPC S1PSU GR or equivalent in Wipro cat part No LR02-501-XXX-57-XX / Havells cat part No ENDURACITYLINERNEXGENSL 45WLED757 SASYBOPC.
Supply and fix / lay cable in repair PVC insulated screened PVC bedded, unarmoured, sheathed, electric power cables 1100 volts grade with stranded copper conductor of size 2.5 Sqmm 3 core with 20mm non metalic PVC FR, heavy duty conduit of suitable size (20mm dia or more), with shaddle complete all as specified and as directed by Engineer-in-Charge. Note: Mode of measurement 3 core cable with PVC conduit shall be measured as one length for connecting all building street lights around the building. Make: Cable Corporation of India (CCI)/ Asian Cable Co, Chattisgarh/ Finolex/ Polycab/ Gloster/Universal/ RPG Cables Ltd , Thane/ Havells India Ltd/ RR Kabel/ KEI Industries Ltd(KEI) Make of PVC conduit-Anchor, Modi, Pressfit, Precision, Astral, Panasonic Anchor, Polycab, Presto Plast, Supreme
Supply and fix in repairs double door, sheet metal enclosure, powder coated, MCB DB SPN 8 way fitted with neutral link, earth bar, din rail and 200 amps rated bus bar, 240 Volt, conforming to IS 13032-1991, concealed in the wall or on wooden board in and including copper lugs/thimbles duly crimped for connection complete all as specified and as directed by Engineer-in-Charge. Make: Legrand / L&T / Havells / ABB / Siemens / Schneider//BENTEC
Supply and fix in repairs MCB SP, 6 Amps to 40 Amps, 240 volts,10 KA 'C' Series, ISI marked complete all as specified and as directed by Engineer-in-Charge. Make : Legrand / L&T / Havells / ABB / Siemens / Schneider//BENTEC
Supply and fix in repairs MCB SPN, 63 Amps, 240 volts,10 KA 'C' Series, ISI marked complete all as specified and as directed by Engineer-in-Charge. Make : Legrand / L&T / Havells / ABB / Siemens / Schneider//BENTEC
Supply and fix in repairs 13.5 Watt, 6500K Bulk head fitting, LED, IP54 protection, working on 240 Volts, 50Hz AC fitting comprising with Premiun quality diffuser for even distribution og light for pathway, staircse lighting, corridor lighting etc complete all as specified and directed by Engineer-in-Charge. Make- Havells cat no ELLIPSE NEO 15.5 W HEXA or equivalent in Philips/ Wipro/Bajaj sample as approved by GE.
Material and labour for earthing complete with Galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of earth the plate not less than 1.5 metres below normal ground level, connected to plate with GI earth strip 25 x 6mm, 7.5 m long from earth point to test point and other end connected to control board / panel / equipment, laid under floors/plinths or fixed on walls or concealed in wall etc by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel with provision of charcoal & common salt packed upto minimum 150 mm all around the earth plate and protected by 40 mm bore light grade galvanised iron pipe complete all as shown in electrical plate No.3 of MES schedule Part I, 2009 with PCC pit in PCC 1:2:4 type B1 using 20 mm graded stone aggregate, MS angle iron frame of size 50mm x 50mm x 5mm, cast iron cover with locking arrangements, GI 20 mm bore medium grade pipe and CI funnel with wire mesh for watering arrangement including necessary excavation and earth work in any type of soil/strata & testing complete all as specified and as directed by Engineer-in-Charge.
Note: Deduct Credit for demolished / dismantled material of Rs. (-) 16,461.00 (Minus) as listed in Schedule of Credit. Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum'
AIRDOT ENGINEERING
ENJOY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .