Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹12.3 L+₹2.4 L (23.7%)Rejected-Finance | L2 | Rejected-Finance Being other then L1 bidder | |
| 3 | L3₹14.4 L+₹4.4 L (44.0%)Rejected-Finance | L3 | Rejected-Finance Being other then L1 bidder |
Tender Value
₹16.5 L
EMD Value
₹33,000
Closing Date
27 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE RAJOURI
HQ CWE Rajouri PIN 900129 c/o 56 APO
REPAIR/ MAINT OF TRANSFORMER, HT LINES AND CONNECTED WORKS IN THE AOR OF HQ 6 and 13 SECTOR UNDER AGE (I) CIF (R)
2023_MES_616454_1
CWE/PAL-32/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AoR of AGE (I) CIF (R)
Please refer tender documents
9 documents required · 9 mandatory
₹500
AGE CIF (R)
₹33,000
Yes
16 Nov 2023
30 Aug 2023
2 Oct 2023
30 Aug 2023
27 Sept 2023
13 Sept 2023
Amount
Dsmantling and taking up bend/rusted PCC/Steel tubular pole by breaking PCC ,staking at site or shifting to MES store yard. complete all as specified and directed.
Supply and fix in replacement danger notice plate of 1.6 mm thick mild steel sheet vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with M S Clamps, bolt and nut approved size for HT poles, 25 x 20 cm size including taking out old unserviceable danger notice plate complete all as specified and directed.
M&L for in replacement Cross-arms, Bracings, Supports, Clamps and Back Plates fabricated from Structural Steel Sections including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated/ directed and inclusive of two coats of Aluminium Paint over a Coat primer, complete all as specified and as directed.
M & L for replacement of Switch Air Break Gang Operated for 11 KV grade, Triple Pole vertically mounted having 12 insulator and fitted on steel frame suitabe for, current rating 400 Amps, mechanically operated mechanism consisting of Operating Rod of GI Pipe 25mm bore (dia) ‘light grade’ of suitable Length worked From Ground Level and with Locking Arrangement Mild Steel Flat Iron Clamp 50x6mm including Expulsion Fuse, Single Pole, Channel type/ drop out type suitable as per Site requirement with Working Pressure 11 KV grade of capacity 50 to 100 Amps including taking down unservice-able Fuse , complete all as specified and as directed.
Supply and fix anti climbing devices, comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered complete all as specified and directed. Note :- Clamps will be measured separately.
Supply & laying in replacement of HT XLPE Cable, insulated, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, conforming to IS:7098 (Part II), 11 KV, ‘Earthed Grade, cross-sectional area 95 Sqmm 3 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/under Road including Testing, complete all as specified and as directed. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
Supply & laying under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armored, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 120 sqmm, 3.5 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including disconnecting and taking out of existing LT cable of any type and size complete all as specified and directed. Note:- Excavation and earth, sand coushioning and protection for cable work shall be measured and paid separately.
Supply & laying under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armored, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 95 sqmm, 3.5 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including disconnecting and taking out of existing LT cable of any type and size complete all as specified and directed. Note:- Excavation and earth, sand coushioning and protection for cable work shall be measured and paid separately.
Materials and labour for replacement of outdoor cable end termination joint Heat shrink type suitable for 11 KV, 50 to 95 sq mm 3 core HT XLPE 11000 volts heavy duty armoured cable complete all as specified and directed.
Materials and labour for replacement of outdoor cable end termination joint Heat shrink type suitable for 11 KV 120 to 185 sq mm 3 core HT XLPE 11000 volts heavy duty armoured cable complete all as specified and directed.
Cable jointing kit for replacement of 11 KV (earthed) heat shrinkable, straight through joint out door suitable for cross sectional area 95 Sqmm, 3 core aluminium conductor XLPE Cable including jointing material and accessories complete and cutting of old cable complete all as specified and directed by Engineer-in-Charge. Note:- (i) Fault location shall be detected and cost of same shall deemed to be included in the quoted rate including necessary earth work.
S&F in replacement of Lightening Arrester Expulsion type complete with all Fittings Transmission Class discharge capacity 65 KA suitable for working pressure of 11000 Volts , complete all as specified and directed.
Dismantling and taking down any type of transformers indoor/outdoor by disconnecting HT & LT connections from plinth/ platform/ pole mounted and shifting to workshop Draining out all the transformer oil, dismantling and inspection of transformer core and winding including taking out burnt out winding/insulation of LV / HV coils in the presence of the authorized rep.. and rewinding the damaged core wih suitable gauge of copper winding wire winding, drying out in Heat chamber till specified IR values are obtained and providing new insulation materials, gasket, nuts , bolts, checking of leakages and rectifying the same by welding etc and conducting all tests as per IS 6792-1972 as specified, for transformer ,complete all as specified and directed. Note: (i) LV/HV bushes, Silica gel breather etc will be measured and paid for separately (ii) While removal of the core, care shall be taken not to spoil the transformer oil and required filtration including topping up shall be carried out, which shall be measured and paid under respective items of schedule.for carry out repair (rewinding) works as directed and reinstall back in original location including re-connection of HT & LT supply system including testing complete all as specified and directed.for the following capacity.(Note spare items required for repair including rewinding will be measured and paid seperately under respective items of Sch. (iii)Placing/removing stand by transformer in the place of defective transformer under repair will be the responsibility of the contractor, stand by transformer of same rating and capacity will be provided by the Contractor till refixing / replacing of repaired transformer.Quoted rate shall be deemed to include hiring charges of standby transformer till commissioning of repaired transformer and satisfaction of Engineer in Charge.If standby Transformer not provided within 8 hours of breakdown ,a penalty recovery will be done from RAR/bill as follows: (a) For first day Rs 5000 (b) For second day Rs 1000 (c) For next every day Rs 1000.
(a) 63 KVA to 160 KVA
(b) 200 to 400 KVA Note:- (a) Required tools & plant including lifting arrangement, transport etc shall be included in the rate quoted. (b) Any damage occurred during lifting/ transporting, the firm will be responsible to rectify such defect free of cost.
Rewinding (Double paper covering) of HT coils of any size and type of transformer including cleaning the burnt out insulating materials, brazing and rewinding with appropriate turns and size of super enamelled copper winding wire including filling insulation paper etc all as specified in particular specifications. Note :- (i) Burnt coils shall be handed over to the contractor by the Engineer-in-Charge through issue voucher for rewinding giving reference of transformer i.e. make Capacity, MES/SM number of transformer etc. (ii) Weight, number of turns, gauge, insulation of winding wire shall be as per OEM. ((iii) Work of rewinding work shall be carried out throught OEM or their authorised vendor only. (iv) Old winding copper wire shall be contractor's property and necessary amount as per schedule of credit shall be deducted from the contractor's due payment.
All as per item No- 16 above but of LT coils of any size and type of transformer complete all as specified in particular specifications.
Materials and labour for replacement of silica gel of breather including providing silica gel as per the existing size / model complete all as specified and directed.
Supply & fixing in replacement breather assly complete with first fill of silica gel all as specified and directed for 63 KVA-160 Kva transformer as per existing make and size.
All as per item No- 19 above 200 KVA - 400 KVA Transformer. complete all as specified and directed.
Materials and labour for replacement of temperature gauge as per the existing size / model complete all as specified and directed.
Supply and fixing in replacement of burnt out/ damaged LV bushes with porcelain insulator and replace with Brass LV bushes, nuts , check nuts, rubber washer etc complete as per the existing size / model, for transformers of capacity complete all as specified and directed for 63 KVA - 160 KVA transformer.
All as per item No- 22 for 200 KVA to 400KVA transformer
Supply and fixing in replacement of burnt out/ damaged HV bushes with porcelain insulator and replace with Brass HV bushes, nuts , check nuts, rubber washer etc complete as per the existing size / model, for transformers of capacity complete all as specified and directed for 63 KVA - 160 KVA transformer.
All as per item No 24 for 200 Kva to 400KVA transformer
Dehydration / Filtration of transformer oil by using Filter Plant and till obtaining the oil dielectric strength 60 KV including topping up of transformer oil to the required level in various transformers located outdoor / indoor sub stations complete all as specified and directed. (Note :- Transformer oil for topping up will be measured and paid separately)
Supply and replacement of topping up of new low viscosity transformer oil from sealed drums conforming to IS 335-1993 Part-II after testing the correct dielectric strength up to 60KV duly de-hydrated complete all as specified and directed.
Material & Labour for 32 mm dia gun metal drain valve of transformer as per existing one complete all as specified and directed.
M&L for preparation of old painted steel or iron surfaces of transformer of 50 to 400 KVA , 11/0.433 Volts capacity transformers by scrapping with steel wire brush/scrapper emery paper, etc. and applying two coats of synthetic enamel smoke grey paint over a coat of red oxide primer (painting shall be done by spray machine) including writing of SM No, MES No etc. at prominent place/location of transformer with black synthetic enamel thick paint in white back ground complete all as specified and directed.
Supply and fixing of Ring type Copper thimble of size 120 sqmm for terminal end of HT cable suitable for 11KV high Voltage carrying high quality material complete all as specified and directed.
Suply only Electrical insulation HT tape of 3/4"width of 30 feet length Etylene Propylene backing highly comfortable to wrap snugly over any shape stretches up 100 percent to avoid moisture, resistant insulation tape of Make as approved.
Excavation in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for Pole, shafts, cesspits, manholes, pier holes, etc and getting out of any type of soil complete all as specified and directed.
All as per Item No: 32 above but depth exceeding beyond 1.5mtr and not exc 3 metre all as specified and as directed
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and as directed.
Material and labour for sand cushioning with fine dry unwashed sand in trenches for protection of cables complete all as specified and directed.
Material and labour for well burnt bricks,Sub class 'B' bricks, best quality locally available laid flat, dry in trenches for cable protection complete all as specified and as directed
Supply & fixing GI Pipe light grade 80 mm dia, ISI marked, of required length for protection of cables complete including necessary MS clamps, nuts, bolts and washers etc complete all as specified and directed.
All as per Srl item No 38 here-in-before but 50mm dia complete all as specified and directed.
Materials and labour in replacement of Stay assy complete with accessories as shown in electric plate No.1 stay rod 16mm incl taking down complete (loop type insulator stay clamps excavation & concrete measured separately) complete all as specified and directed.
S&F in replacement Loop type insulator vitreous porcelain, brown or green with overall dimensions 65 x 90 mm, clearance of hole 16mm all as specified and as directed.
Materials and labour in replacement pin type porcelain , vitreous, white, brown or green insulator including one galvanized mild steel spindle, two G I washers and one G I nut, 150 mm height and 150 mm dia suitable for 11000 Volts grade complete all as specified and directed.
Material & Labour in replacement for Disc Insulator porcelain viterous ,Whit/Brown/Green 145mm high and 255 mm dia ball and socket type for working 11000Volts complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation of poles etc including necessary form work, complete all as specified & directed.
M&L for PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as in stay etc including necessary form work, complete all as specified & directed.
M&L for PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in coping of pole etc including necessary form work, complete all as specified & directed.
Material and labour steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (11 meters long) and applying two coats of aluminum paint over a coat of red oxide primer,the embeded portion shall be applied with two coats bituminous paint complete all as specified and directed.Note : PCC & Earth work will be measured and paid seperately.
Material and labour for aluminium conductor steel reinforced (ACSR) of any size stringing properly on insulators on pole and binding with aluminium tape /binding with connectors, jumpers etc including dismantling and taking down old unserviceable ACSR conductor complete all as specified and directed.
Restringing of HT/LT overhead line conductor comprising of three run ACSR conductor and two run GI earth contunity conductor after opening from insulators, including restraining same and winding on insulator with proper size of binding wire upto permissible sag complete all as specified and directed by Engineer-in-Charge. Note :- Quoted rate shall be deem to included the cost of winding wire and replacement of insulator if damaged during restraining of conductor. (ii) Insulator shall be paid separately as supply only under respective item of this schedule.
S&F Galvanised Steel Wire 3.15 or 4.0mm dia as Earth Continuity Conductor and fixed to Pole, binding with Aluminium Binding Wire, complete all as specified and as directed. NOTE : Cost of Binding Wire will deem to be included in the Quoted Unit Rate.
S&F Cradles, hexagonal/rectangular fabricated with Galvanised Steel Wire with 4.00mm dia including binding with Aluminium Binding Wire, including taking out old cradles complete all as specified and as directed. NOTE : Cost of Binding Wire is deemed to be included in the Quoted Unit Rate.
Material and labour for painting to steel tubular pole 11/9 metre long with two coats of synthetic enamel silver up to below 1.5M from Top edge and 1.50 metre height from ground level in 30 cm alternative black and red strips and remaining portion with alluminium paint incl numbering of pole no by stensils and MS frames like channel,clamps, angle, D-clamps etc with two coats of aluminium paint complete all as specified and directed.
Materials and Labour for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge of the earth plate at a depth not less than 1.5M below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm (Reinforced with 8 mm dia. TMT bars @ 150 mm, center to center both ways) with one handle for lifting made out of 8 mm dia. MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing light grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown on electrical plate No 3 of SSR Part-I (2009) complete as specified and directed.
All as per item No 53 herein before but with Galvanized iron strip of size 32 x6mm all as specified and directed.
S&F Earth continuity conductor passing through PVC Conduit of size 40 mm main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required 32x6 mm galvanised iron strip complete all as specified and directed by Engr-in-Charge.
Cutting of green growth and wild grass by manual labour or by machine at electrical installation premises,around the pole,along the fencing,removing rubbish from the site of work and depositing where directed not exc 100 Mtr from the starting point. complete all as specified and directed. Note :- The item shall be operated maximum 4 times in the entire period of the contract and the measurement will be taken every time independently for the payment.
Cutting and trimming of tree branches to clear the over head lines in the arc of HT/LT over head lines/feeders (including repairing and jointing of ACSR conductor if damaged during cutting of trees branches) and removal of trimmed branches of trees and depositing the same in waste bin inside the campus all as specified and directed (Span length not more then 50 Mtr).
narayan construction
CHOPRA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .