Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 LAccepted-AOC C O EROS PALA EAST LABAN ROAD SHILLONG 793004 | EAST KHASI HILLS | MEGHALAYA | 793004 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹25.7 L+₹1.4 L (5.57%)Rejected-Finance 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L2 | Rejected-Finance REJECTED BEING OTHER THAN L1 BIDDER | |
| 3 | L3₹25.9 L+₹1.6 L (6.50%)Rejected-Finance 1630 SECTOR 7C CHANDIGARH 160019 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160019 | L3 | Rejected-Finance REJECTED BEING OTHER THAN L1 BIDDER | |
| 4 | L4₹27.3 L+₹3.0 L (12.5%)Rejected-Finance RONGMEN BLOCK IV NEAR UMROI MILITARY STATION P O BARAPANI SHILLONG 793103 | SHILLONG | RI BHOI | MEGHALAYA | 793103 | L4 | Rejected-Finance REJECTED BEING OTHER THAN L1 BIDDER | |
| 5 | L5₹27.7 L+₹3.3 L (13.8%)Rejected-Finance DEEDAR MARKET ROOM NO 16 POLICE BAZAR SHILLONG 793001 | SHILLONG | EAST KHASI HILLS | MEGHALAYA | 793001 | L5 | Rejected-Finance REJECTED BEING OTHER THAN L1 BIDDER |
| Sl No | Description | Qty | Unit | M/s A L Traders L10 | HAMZA CONSTRUCTION CO L8 | M/S Mani Construction L7 | A K ENTERPRISE L6 | S K Construction L1 | TN CONSTRUCTION L5 | MAHINDER ELECTRICALS L2 | SAGGI ELECTRIC COMPANY L3 | M/S AKC ENTERPRISE L9 | M/s S L Wankhar L11 | Singh and Co L12 | M S Umesh and Co L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down and dismantling of street/security/posttop light fittings of any type size and model (FTL, HPSV, MVL, MH, floodlight , LED Fittings etc), and check at the site in the presence of MES rep, repaire at the site with replacement of spare parts ( wire, drivers, choke etc) and refixing after cleaning and testing. If not found repaireble than depositing the same to MES store yard for replacement as directed by Engr in Charge complete.
Note :- The Quoted rates shall to be included for the following :-
(a) As the above work is required to be carried out for repair/maint of street/security/posttop light fittings entire Cantt area Shillong , HV Area and SE Falls area hence complaints of the US street/security/posttop light fittings to be handed over daily basis (if received) for different units locations and repairs to be carried out on the same day or next day or as directed by Engr-in-Charge.
(b) The contractor shall depute adequate well experienced electrician and helper (As per the complaint) with all connected tools on daily basis (if required) with suitable vehicle & T&P arrangement to repairs and attend the complaints in various units under AOR of GE Shillong and manage all spares included in this CA in advance or as directed by Engr-in-Charge. | 1,500 | Each Job | 350 ₹5,25,000 | 200 ₹3,00,000 | 80 ₹1,20,000 | 52 ₹78,000 | 100 ₹1,50,000 | 40 ₹60,000 Lowest | 145.55 ₹2,18,325 | 243 ₹3,64,500 | 190 ₹2,85,000 | 50 ₹75,000 | 230 ₹3,45,000 | 271 ₹4,06,500 |
| 2.00 | Supply and fixing of driver for LED luminary suitable for single phase 45 watts complete incl taking out of fitting from pole and refixing after repair complete all as per existing specification & Make as per fitting fixed at site. | 70 | Each | 1,100 ₹77,000 | 620 ₹43,400 | 740 ₹51,800 | 620 ₹43,400 | 1,000 ₹70,000 | 1,240 ₹86,800 | 750 ₹52,500 | 405 ₹28,350 Lowest | 1,700 ₹1,19,000 | 800 ₹56,000 | 800 ₹56,000 | 949 ₹66,430 |
| 3.00 | Supply and fixing of driver for LED luminary suitable for single phase 60 watts complete incl taking out of fitting from pole and refixing after repair complete all as per existing specification & Make as per fitting fixed at site. | 50 | Each | 1,350 ₹67,500 | 750 ₹37,500 | 906 ₹45,300 | 830 ₹41,500 | 1,200 ₹60,000 | 1,540 ₹77,000 | 750 ₹37,500 | 405 ₹20,250 | 1,700 ₹85,000 | 1,000 ₹50,000 | 350 ₹17,500 Lowest | 1,191 ₹59,550 |
| 4.00 | Supply and fixing of driver for LED luminary suitable for single phase 25/35 watts complete incl taking out of fitting from pole and refixing after repair complete all as per existing specification & Make as per fitting fixed at site. | 50 | Each | 750 ₹37,500 | 535 ₹26,750 | 660 ₹33,000 | 624 ₹31,200 | 700 ₹35,000 | 850 ₹42,500 | 498 ₹24,900 | 405 ₹20,250 | 1,170 ₹58,500 | 500 ₹25,000 | 220 ₹11,000 Lowest | 681 ₹34,050 |
| 5.00 | Supply and fixing of driver for LED Bollard 08 watt complete incl taking out of fitting and refixing after repair complete all as per existing specification & Make as per fitting fixed at site. | 16 | Each | 1,650 ₹26,400 | 430 ₹6,880 | 560 ₹8,960 | 936 ₹14,976 | 1,250 ₹20,000 | 1,850 ₹29,600 | 1,800 ₹28,800 | 405 ₹6,480 | 900 ₹14,400 | 800 ₹12,800 | 150 ₹2,400 Lowest | 2,756 ₹44,096 |
| 6.00 | Supply and fixing of driver for LED Bollard 09 watt complete incl taking out of fitting and refixing after repair complete all as per existing specification & Make as per fitting fixed at site. | 20 | Each | 1,650 ₹33,000 | 430 ₹8,600 | 560 ₹11,200 | 1,040 ₹20,800 | 1,250 ₹25,000 | 1,850 ₹37,000 | 2,222.25 ₹44,445 | 405 ₹8,100 | 900 ₹18,000 | 900 ₹18,000 | 160 ₹3,200 Lowest | 2,905 ₹58,100 |
| 7.00 | Supply & fixing in repair Gate / Post Top lantern LED lights fitting of capacity 20 W die-cast aluminium body, 20 watt LED 3000/5700K and toughened glass complete with all accessories incl taking out old unserviceable one all as directed. | 10 | Each | 4,150 ₹41,500 | 4,700 ₹47,000 | 6,000 ₹60,000 | 6,100 ₹61,000 | 2,800 ₹28,000 | 4,540 ₹45,400 | 2,955.55 ₹29,555.5 | 2,025 ₹20,250 | 4,500 ₹45,000 | 5,000 ₹50,000 | 1,550 ₹15,500 Lowest | 3,551 ₹35,510 |
| 8.00 | Supply & fixing in repair Gate / Post Top lantern LED lights fitting of capacity 40 W die-cast aluminium body, 40 watt LED 3000/5700K and toughened glass complete with all accessories incl taking out old unserviceable one all as directed. | 10 | Each | 6,350 ₹63,500 | 7,200 ₹72,000 | 7,200 ₹72,000 | 8,320 ₹83,200 | 4,500 ₹45,000 | 7,000 ₹70,000 | 2,850 ₹28,500 | 3,321 ₹33,210 | 7,000 ₹70,000 | 8,000 ₹80,000 | 1,250 ₹12,500 Lowest | 6,500 ₹65,000 |
| 9.00 | Supply & fixing in repair Garden light/LED Bollard LED Warm white lighs fitting of capacity 10 W die-cast aluminium body, 10 watt LED toughened glass complete with all accessories incl taking out old unserviceable one complete all as specified and directed. | 40 | Each | 3,990 ₹1,59,600 | 3,700 ₹1,48,000 | 3,700 ₹1,48,000 | 5,200 ₹2,08,000 | 2,700 ₹1,08,000 | 4,450 ₹1,78,000 | 2,899 ₹1,15,960 | 2,835 ₹1,13,400 | 3,995 ₹1,59,800 | 6,000 ₹2,40,000 | 800 ₹32,000 Lowest | 3,500 ₹1,40,000 |
| 10.00 | Supply & fixing in repair Garden light/LED Bollard LED light fitting of capacity 10 W die-cast aluminium body, 10 watt LED toughened glass complete with all accessories incl taking out old unserviceable one complete all as specified and directed. | 39 | Each | 3,300 ₹1,28,700 | 3,950 ₹1,54,050 | 6,000 ₹2,34,000 | 3,640 ₹1,41,960 | 2,700 ₹1,05,300 | 3,700 ₹1,44,300 | 2,899 ₹1,13,061 | 2,835 ₹1,10,565 | 3,700 ₹1,44,300 | 4,000 ₹1,56,000 | 450 ₹17,550 Lowest | 3,427 ₹1,33,653 |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
19 Jul 2025, 6:00 pmClosed
GE SHILLONG
GE SHILLONG SHILLONG PIN 793002
REPAIR/MAINT OF STREET LIGHT AND GARDEN LIGHTS AT 58 GTC AND ARC AND 11 WEU AND SE FALLS SHILLONG CANTT UNDER GE SHILLONG
2025_MES_717371_1
GE/SHL/TOKEN-45 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE SHILLONG
ALL AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE SHILLONG
₹72,000
Yes
20 Aug 2025
28 Jun 2025
21 Jul 2025
28 Jun 2025
19 Jul 2025
12 Jul 2025
Amount
Taking down and dismantling of street/security/posttop light fittings of any type size and model (FTL, HPSV, MVL, MH, floodlight , LED Fittings etc), and check at the site in the presence of MES rep, repaire at the site with replacement of spare parts ( wire, drivers, choke etc) and refixing after cleaning and testing. If not found repaireble than depositing the same to MES store yard for replacement as directed by Engr in Charge complete. Note :- The Quoted rates shall to be included for the following :- (a) As the above work is required to be carried out for repair/maint of street/security/posttop light fittings entire Cantt area Shillong , HV Area and SE Falls area hence complaints of the US street/security/posttop light fittings to be handed over daily basis (if received) for different units locations and repairs to be carried out on the same day or next day or as directed by Engr-in-Charge. (b) The contractor shall depute adequate well experienced electrician and helper (As per the complaint) with all connected tools on daily basis (if required) with suitable vehicle & T&P arrangement to repairs and attend the complaints in various units under AOR of GE Shillong and manage all spares included in this CA in advance or as directed by Engr-in-Charge.
Supply and fixing of driver for LED luminary suitable for single phase 45 watts complete incl taking out of fitting from pole and refixing after repair complete all as per existing specification & Make as per fitting fixed at site.
Supply and fixing of driver for LED luminary suitable for single phase 60 watts complete incl taking out of fitting from pole and refixing after repair complete all as per existing specification & Make as per fitting fixed at site.
Supply and fixing of driver for LED luminary suitable for single phase 25/35 watts complete incl taking out of fitting from pole and refixing after repair complete all as per existing specification & Make as per fitting fixed at site.
Supply and fixing of driver for LED Bollard 08 watt complete incl taking out of fitting and refixing after repair complete all as per existing specification & Make as per fitting fixed at site.
Supply and fixing of driver for LED Bollard 09 watt complete incl taking out of fitting and refixing after repair complete all as per existing specification & Make as per fitting fixed at site.
Supply & fixing in repair Gate / Post Top lantern LED lights fitting of capacity 20 W die-cast aluminium body, 20 watt LED 3000/5700K and toughened glass complete with all accessories incl taking out old unserviceable one all as directed.
Supply & fixing in repair Gate / Post Top lantern LED lights fitting of capacity 40 W die-cast aluminium body, 40 watt LED 3000/5700K and toughened glass complete with all accessories incl taking out old unserviceable one all as directed.
Supply & fixing in repair Garden light/LED Bollard LED Warm white lighs fitting of capacity 10 W die-cast aluminium body, 10 watt LED toughened glass complete with all accessories incl taking out old unserviceable one complete all as specified and directed.
Supply & fixing in repair Garden light/LED Bollard LED light fitting of capacity 10 W die-cast aluminium body, 10 watt LED toughened glass complete with all accessories incl taking out old unserviceable one complete all as specified and directed.
Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with Efficacy > 100 LPW , 10 KV SPD, high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete suitable for GI bracket of dia 43 mm all as directed by Engr-in-Charge.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with Efficacy > 100 LPW , 10 KV SPD, high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete suitable for GI bracket of dia 43 mm all as directed by Engr-in-Charge.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with Efficacy > 100 LPW , 10 KV SPD, high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete suitable for GI bracket of dia 43 mm all as directed by Engr-in-Charge
Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with Efficacy > 100 LPW , 10 KV SPD, high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete suitable for GI bracket of dia 43 mm all as directed by Engr-in-Charge
Supply and fixing LED flood light 120 watt 230 V AC outdoor type with Efficacy > 100 LPW , 10 KV SPD with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp fixed on wall/roof/pole/floor/highmast with the help of nuts, bolts , washers and clamps etc all as directed by Engr-in-Charge
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with Efficacy > 100 LPW , 10 KV SPD with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp fixed on wall/roof/pole/floor/highmast with the help of nuts, bolts , washers and clamps etc all as directed by Engr-in-Charge Note applicable for item No 7 to 16 :- (i) 03 years warranty certificate from OEM shall be submitted by the contractor. (ii) CA No shall be marked on each fitting with permanent marker)
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for laying of cable/erection of pole and getting out in soft/loose all complete as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5 m in depth for laying of cable/erection of pole and getting out in soft/loose all complete as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in hard/dense soil complete all as specified and as directed.
Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as directed.
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles , including necessary form work finishing even and smooth without using extra cement , all as specified and directed.
M&L PCC (1:3:6) type C2 using 40mm graded aggregate as in foundation for stay set /Pole/ FPB etc including fair finish even and fir to exposed surfaces without using extra cement complete all as specified and as directed.
Supply & laying Sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable ) and gently punned down to 18cm thickness all complete as specified and as directed. Note :- Only punned down sand shall be measured.
M&L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete.
Dismantling/taking out carefully of old LT cable of any size type or core and kept aside for reuse / rerouting / jointing / replacement etc complete
Dismantling/taking out carefully of old bricks any size type kept aside for reuse / rerouting / jointing / replacement etc complete
Laying only serviceable bricks for protection of cable obtained during excavation from item No. 8 here-in-before.
M & L laying or passing through pipe LT UG XLPE insulated, armoured heavy duty 1100 volts grade with aluminum stranded conductor of cross sectional area 16 sq mm 4 core complete all as directed.
All as per Item No 28 here and above but 10 sqmm 4 core
All as per Item No 28 here and above but 10 sqmm 2 core
Supply and fixing/laying 40mm bore, steel tubings, galvanised, light grade with all fitting laid across road , in trenches or across PCC drain or along electric pole or floor/wall etc for protection of cable including taking down old unserviceable one complete all as specified and as directed.
Dismantling existing steel poles/ struts, any size carefully for reuse including necessary excavation demolition of concrete transportation cost etc. and removing the old unserviceable rubbish etc
M & L for Steel tubular swaged poles complete with cast iron/MS base plate , finial taper plug , bolts , nuts & screws as specified type 410 SP-22 , 8.5 meter long complete. Note: PCC anti climbing device, cross arms, insulator, ACSR conductor and earth work measured and paid separately)
S&F in repair GI Bracket of dia 40 mm light grade with 1.2 mtr length including fixing the fitting removed for changing the bracket and connection with existing wire etc all as directed.
Supply and fixing PVC Insulated and sheathed three core Heavy duty cables 1100 volts 03 core having multi stranded aluminium conductor service cable size 4 sqmm complete all as specified and directed.
Supply & Fixing junction box in repair made of polycarbonate with IP 65 degree of protection , dust proof, water tight, light weight, acid resistant, corrosion proof inslated & shock proof, fire retardant, self extinguishing, halogen & silica free non-toxic material, UV resistant, with internally ebbedded gasket fitted with required connector/terminals for upto size 25 sqmm 4 core cable and with openable front including Glands and Street light connection incl taking down old unserviceable one
Supply and fixing in repair of street light timer panel made of polycarbonate body including Digital Timer Switch, 40/63A 3 phase Contactor, MCB and wiring if any required with min 1 Sqmm copper conductor cable and instrument wiring with 1.5 Sqmm fine, terminal blocks etc incl taking out old unserviceable one complete .
Supply & Fixing in repair of power contactor three pole 40/63 Amp 415 Volts din rail mounted type on existing panel complete.
Supply & Fixing in repair of Digital Timer Switch (Crono time switch) 110-240V AC 1 C/O - 2 Module on existing panel complete.
Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized iron wire of 4 sqmm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 15 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, Chequred plate cover plate of size 30x30x10 cm with one handle for lifting made out of 8 mm dia MS bar, funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SRR part 1 including testing on completion all as specified and directed. incl demolition to existing one complete.
Taking down lumanaries of High Mast and servicing the motor, gear, Chain etc and restoring the lumanaries to top of the mast of pole, including charges for machinery/hydra required for fixing at top position as directed.
S & Fix LED light strip type 11.5 watt of 20 mtrs length all as dirceted.
Supply and fixing or passing through pipe, service connection cable 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 sq. mm 2 core nominal cross section in service connections
Supply and fixing or passing through pipe, service connection cable 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq. mm 2 core nominal cross section in service connections
Supply and fixing or passing through pipe, service connection cable , 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm 2 core nominal cross section in service connections
Supply and fixing or passing through pipe, service connection cable , 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 16 sq. mm 2 core nominal cross section in service connections
Supply and fix in repairs MCB, single pole 240 volts 6 to 32 Amps capacity fixed in existing junction box
MAHINDER ELECTRICALS (BID ID -3363550)
SAGGI ELECTRIC COMPANY (BID ID -3364512)
M S Umesh and Co (BID ID -3364591)
TN CONSTRUCTION (BID ID -3364473)
A K ENTERPRISE (BID ID -3364705)
M/S Mani Construction (BID ID -3364810)
HAMZA CONSTRUCTION CO (BID ID -3364540)
M/S AKC ENTERPRISE (BID ID -3364803)
M/s A L Traders (BID ID -3364456)
M/s S L Wankhar (BID ID -3361192)
Singh and Co (BID ID -3364113)
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .