Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L1 | Accepted-AOC Being L1 bidder award of Contract | |
| 2 | L2₹19.4 L+₹1.4 L (8.06%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹20.8 L+₹2.8 L (15.7%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹21.5 L+₹3.6 L (19.9%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹21.5 L+₹3.6 L (19.9%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD PIN 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L5 | Rejected-Finance Not being L1 |
Tender Value
₹21.8 L
EMD Value
₹43,700
Closing Date
21 Jan 2021, 6:00 pmClosed
CWE HQ 133 WKS ENGRS
HQ 133 WKS ENGRS PIN 914133 C/O 56 APO
PROVN OF 160 KVA DG SET AT CSD DEPOT BB CANTT SRINAGAR
2020_MES_406154_1
CWEK-56/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 864 EWS
Class E Category b i
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹43,700
Yes
HQ 133 WKS ENGRS
25 Mar 2021
23 Dec 2020
23 Jan 2021
23 Dec 2020
21 Jan 2021
7 Jan 2021
23 Dec 2020 - 31 Dec 2020
31 Dec 2020
Amount
Excavating in trenches, not exceeding 1.50 metre wide and not exceeding 1.50m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10 sq.m on plan and not exceeding 1.50m in depth and getting out in soft/loose soil, complete all as specified and as directed .
Returning filling in including spreding leveling watering and well ramming in layers not exc 25 cm each in soft/loose soil, complete all as specified and as directed .
Removing excavated materials to a distance not exc 50 m and depositing where directed at level n exc 1.5 above the starting points, complete all as specified and as directed .
Material and Labour for Fine and dry sand cushioning for underground cable by providing a layers of sand 8cm deep before laying and 15cm deep after laying the cable including tretching the cable, complete all as specified and as directed . Note - Punned thickness of sand layer shall be measured and paid to contractor.
Material and labour for sub class brick laid dry width wise across the cable in trenches for protection of cable complete all as specified.
Supply, Installation, testing and commissioning of silent type Diesel engine driven generating set with Governing class (as per ISO 8528 Part V) -G2 incl sound reducing canopy (sound level not more than 75 db) 14 guage as per guideline issued by Ministry of Environment & forest notification, & Central pollution control board or GSR 54(E) dt 23 Jan 2015, 415 volts, 3 phase, 50 Hz supply complete with panel for automatic starting or main failure control panel suitable for giving an output of 160 KVA after considering derating factor confirming to IS-1601 at 1800 metre altitude above mean sea level and capable of operating between temperature range (-20) degree C to 40 degree C (at Srinagar area of J & K) and alternator of suitable capacity and RPM coupled with each other & capable of taking 10% over load for one hours on every 12 hours (As per BS-5514/649) with flexible coupling mounted on common base plate on Antivibration pads on foundationas recommended by manufacture. The DG set shall comprise of Electric starter motor with batteries, Turbocharger, water cooled & comprising all standard fittings, fixtures & all piping etc as below :- (a) Alternator : Directly coupled with Engine and suitable to produce 415 volts, 3 phase 4 wire system, 50 Hz 0.8 PF @1500 RPM of capacity 160 kVA all as per as per IS: 13364 and up to date amendments with H class insulation having efficiency 91% on 100% load at 0.8 PF, self excited, self regulated, screen protected drip proof type with two end shield ball/Roller bearing with damper winding in each pole faces as per IS-4722 or BS 2613-1970 all as specified and directed (b) Engine : Water cooled Deisel Engine (CPCB Norms Compliance) developing Min 248 BHP or as recommended by the manufacturer for 1800 mtr altitude having Self start engine (including batteries with provn of charging the batteries and leads) suitable to drive above specified alternator complete with foundation (foundation design as per OEM), as per IS:10001/ 10002, coupled directly through flexible coupling, multi cylinder four stroke, cold starting, 1500 RPM industrial type as per BS-649 or IS-1601 with AI electronic governer suitable to regulate speed of DG set from No load to full load completed with fuel tank of cap as per manufacturer recommendations, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and silencer mufflers etc for continuous operation and standard accessories, sump pre heaters, cold start kit etc all as specified and directed. (c)Canopy : Acoustic enclosure shall be powder coated and fabricated out of 16 SWG CRCA MS sheet. The silent canopy shall be of nut bolt type construction. Critical processes of punching is done on CNC machines to maintain dimensional accuracy of holes within 0.1 mm. Powder coating is done after seven‐tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE‐RETARDANT foam as acoustic material . Four hinged doors shall be provided to canopy, one door shall have glass window for control panel.
(d) Base Frame : Base frame is fabricated in sheet metal. The base frame will be primer coated and painted. The base frame is rugged n construction and designed for mounting engine and alternator close coupled, with cross members mounted on AVM. The base frame shall have provision for mounting of acoustic enclosure & control panel on in it. The base frame is having provision of lifting hook for convenient lifting of complete set, i.e. along with canopy, engine and alternator. (e) Generating Panel :- DG set should consist of standard Generating Panel. (f) Exhaust System: The exhaust system and noise suppressor shall be provided with thermal insulation by using fire retardant / non igniting foam conforming to BIS 7888/BS 4375 to prevent excess heat radiation on the engine and safe for operator. (g) Fuel Tank: Fuel tank shall be fabricated out of 16 SWG CRCA MS Sheet . It is duly painted and fitted with inlet and outlet connections. Float gauge and fuel float switch is provided. Fuel tank shall have guage duly calibrated at every 5 mtrs. daily service fuel tank of suitable capacity as per manufacturer's instruction of having min fuel storing cap of 12 hours for running DG set including fuel oil indicating gauge drain and vent plug etc complete on a common base within the acoustic enclosure. (g) Control Panel :- Alternator inbuilt control panel 415 Volt ,3 phase, 4 wire, 50 cycle fabricated out of 1.6mm thick MS sheet painted with internally/externally with two coats of synthic enamelled paing over one coat of primer complete with internal copper wiring sutiable for 160 KVA DG Set comprising of MCCB 4P,250 Amp 36 KA 01 No with spreader link,Multifunctional meter suitable to indicate Volt,power factor,bty voltage,RPM frequency,temp, oil pressure,hours run,Current AMP,KW, KWH etc. Note:- 1. Capacity of alternator at 1800 meters altitute -160 kVA, AC 3 Phase, 415 volts, 50 Hz. and as recommended by the manufacturer for above sized motor. 2. Place of installation- Near CSD depot BB Cantt Srinagar. 3. PCC platform 1:2:4 600 mm thick using 40mm graded stone aggregate to suit base frame size 45 cms below & 15 cms above ground level. Grouting 08 bolts of 600mm x 30mm and fixing the engine and alternator with base frame on the platform. PCC shall be measured & paid separately. 4. Engine and alternator shall be assembled on common steel frame by the manufacturer itself and not by rep / authorised agent / sister concern etc. 5. Engine shall be designed keeping in consideration of de-rating factor for 1800 meters altitute. 6. Canopy and engine shall be of same make. 7. Installation, testing and commissioning of Gen Set shall be done in presence of maufacturer's Engineer and not by any authorised person / rep/sister concern etc 8. DG Set to be tested for 12 Hrs contineously on full load (Rated load) including 1 Hr at 110% load. All testing materials and fuel to be provided by the contractor. 9. Rates also incl a skilled labour (FGM) for operation & training purpose for the period of 90 Days after handing / taking of DG set with user unit. FGM should have minimum qualification as per central Govt rule and should have minimum five year experience to maintain and opearte the DG Set. Bidder has to follow minimum wages as notified by the Government of India / State Government / Local body whichever is higher including all statutory provisions 10. complete unit/set shall be equipped with all standard fitting as per manufacture recommendations and mounted on common base frame with following fitting and rates shall be deemed to be inclusive of the same:-
(a) Fly wheel with bousing (b) Cooling system : Mounted radioter with fan and belt (c) Cooling water pump : Centrifucal type belt driven (d) Exhaust gas (i) turbo charger type (ii) Exhaust mainfold, Silencer : (i) Residential type,(ii) Bellows (d) Fuel System: Fuel injection system with fuel injectors fuel injection solenoid switch/nozzle/governer electronic type capable for 1% speed/frequency reglation.fuel filters,fuel hoses(e)Lub oil System:(i) Lubricating oil filter (ii) Lubricating pump (f) Air intake System :(i) Air intake Manifold (ii) Air cleaner dry type (g) Governer : Electronic Governer with actuator (h) Starting System : Electric Self starter with maintenance free batteries including battery charging alternator
(j) Batteries : maintenenace free batteries of 12 Volt /24 volt as per manufacturer direction complete with copper conductor multistranded lead of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electronic all as specified. Starter gear ring, start and stop push button , ignition key/switch,(k) Handing and operation : Sailent features of accessories shall be as under :-Radiator with blower fan , Corrosion inhibitor coolent, paper element filter for fuel, lub oil and by pass, Elecronic governer controlled direct fuel injection system, Fly wheel housing and fly wheel (k) Generator Monitoring Panel : Comprising of following:- (i) Microprocessor based genset controller for metering, monitoring,governing and protection (ii) Engine protection for low oil pressure, high coolent temperature (alarm & shutdown) (iii) Alternator protection parameter like under voltage, over current, under frequency, over frequency, (alarm & shutdown) (iv) Relay drivers for remote annuciations (v) Cyclic cranking (vi) Auto/manual strat/stop (vii) Operator within a temperatur ( range (-20 to 60 degree C) and humidity upto 95% (viii) Remote monitoring capacity throught separate interface moudules (m) Genset metering parameters like lube oil pressure, coolent temperature, engine speed (RPM), run hours, DC voltage, intake manifold temperature, 3 phase volts and 3 phase amperes,frequency, KW,KVA, power factor. (n) Safety Controls :- Engine low lube oil pressure, high water temparature and over speeding of engine (o) Coupling arrangement : Flexible coupling, fly wheel to suit flexible coupling fly wheel housing (p) Accessories :- AVM pads builts or separately mounted to manufacture base frames.(q) Base frame : Stardy design made of MS channel with necessary reniforcement and predetermined holes. (r) daily service fuel tank of suitable capacity as per manufacturer's instruction of having min fuel storing cap of 12 hours for running DG set including fuel oil indicating gauge drain and vent plug etc complete on a common base within the acoustic enclosure.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core complete all as specified and directed.
Supply, install, test & commission LT panel outdoor type, dust & Vermin proof self supporting fabricated out of CRCA steel sheet 3 mm thick at outer cover and 1.6 at inner compartment of size 1200 X 2000 X 450 ( l x b x h) mm with base ISMB 100 mm and Angle Iron frame (50x50x5mm) support to mount panel and tightened with 06 Nos 30 mm x 15 mm bolts & nuts with 4 Legs 30 cms below & 30 cms above GL grouted in PCC 1:3:6 Type C2 , cubicle type floor mounting, suitable for 3 phase 4 wire, 415 V, 50 Hz, AC supply, having cable ally on both sides of panel independant bays for incomming & outgoings with openable from front, rear, left & right side . Duly painted with powder coating (7 tank process) and PU gasket . Cable lugs are to be used to terminate cables/wires. Existing incomming connections are to be re-arranged as directed by Engineer-in-Charge. Single core copper cables shall be used for connections from bus bar to MCCBs/MCBs/instuments etc.
Surface levelling and excavation for PCC 1:2:4 plateform of size 5 mX 3.0 m X 0.3m including hard core, mild steel work post, trusse purlin rafter inclusing other work including special shaped washer etc complete using EWR or induction butt welded of any section with 0.5 mm thick pre painted galvanised aluminium zinc coating GI based corrugated sheet having tensile strength of 550 mpa as in roof covering , shed of 6.0 X 4.0 mtr for packaged type DG Set including steel structure for protection from rain and snow etc all as per site requirement and all as directed by Engr-in-charge.
Earthing complete with galvanised steel earth plate of size 60cmx60cmx6mm thick, burried directly in ground, earth pit not less than 2.25m deep below normal ground level with top edge of the plate not less than 1.5m below normal ground level, connected to equipment by using GI strips of size 32x6mm as earthing lead by means of bolts,nuts,checknut & washers of galvanised iron all as shown in elect plate No.5 of MES schedule and connected to earthing test point all as specified and directed including earth pit of size 30cmx30cmx45cm made of PCC 1:3:6 and PCC 1:2:4 cover, funnel, GI tubing etc. & testing on completion, all as specified. Note : The units rate includes the cost of excavation & earth work in any type of soil charcoal & salt in altemate layers, 20mm GI Pipe (light grade) for watering 40mm GI protection pipe (light grade) funnel wire mesh PCC 1:2:4 type B1 chamber in cement concrete ,50 mm thick precast RCC M-25 cover duly reinforced with XPM (weight not less than 3 kg /sqm ) and CI frame etc , and including provision of test point , connecting to test point and testing on completion etc, complete all as specified.
Galvanised iron strip 32 x 6mm buried in ground complete all as specified and directed.
GI pipe, light grade 100 mm bore, ISI Marked for protection to cable along the pole/across road crossing/passing through culvert complete all as specified.
PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) in foundation of electric poles, struts PCC blocks and fair finish to exposed surfaces without using extra cement etc complete all as specified.
ALCO ENGINEERSPVT LTD
M/S Mohammad Saleem and Co
M/S Khan Hussain & Co.
national engineering
RAMESH AND CO
ABDUL MAJID BHAT
CHINAR CONSTRUCTION TRADERS
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .