| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAccepted-AOC | L1 | Accepted-AOC Reasonable lowest tenderer | |
| 2 | L2₹28.6 L+₹2.4 L (9.24%)Rejected-Finance LABU RAM STREET KOTKAPURA PB 151204 | KOTKAPURA | FARIDKOT | PUNJAB | 151204 | L2 | Rejected-Finance Not Lowest tenderer |
Tender Value
₹33.1 L
EMD Value
₹66,220
Closing Date
24 Feb 2024, 6:00 pmClosed
GE (East) Ferozepur Cant
GE (East) Ferozepur Cant
Provn of rewiring in Bldg No. E17 C and D at Rajput and 10 KVA Stabilizer 3 phase at Oxygen Plant of Fd Hosp and Addn altn to Bldg No. E3 at Inf, P12 Office Bldg of Stn HQ and OR Institute and Guard room of Adm Bldg under GE (East) FZR Cantt.
2024_MES_639406_1
8157/GE/E/FZR/23-24/E8
Open Tender
Civil Works
Item Rate
180 days
GE (East) Ferozepur Cant
Please refer Tender Documents
8 documents required · 8 mandatory
₹500
Yes
GE (East) FZR Cantt
₹66,220
Yes
23 Mar 2024
29 Jan 2024
26 Feb 2024
29 Jan 2024
24 Feb 2024
12 Feb 2024
Amount
B/R Works Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) of not exc 1.5 sqm each complete all as specified and directed.
Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) of exc 1.5 sqm but n exc 4 sqm each complete all as specified and directed.
S&F Factory made box type steel ventilator with glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified and directed.
Demolition of brick work or stone/boulder masonary built in cement mortor including all quoins,arches,pillars etc, complete all as specified and directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and directed.
Taking down cement plaster on brick walls of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed
M&L for rendering 15 mm thick in cement mortar (1:4) on any face of brick walls or concrete surfaces, finished even and smooth(without using extra lime or cement) complete all as specified and directed
M&L for rendering 15 mm thick in cement mortar (1:6) on any face of brick walls or concrete surfaces, finished even and smooth(without using extra lime or cement) complete all as specified and directed
Preparation of newly plastered surface of wall and applying two coat of oil emulsion distemper over primer coat complete all as specified and directed
Preparation of new plastered surfaces and applying two coats of cement base paint complete all as specified and directed.
M&L for Preparation of old decorated surface of wall and applying one coat of oil emulsion distemper complete all as specified and directed.
M&L for Preparation of old decorated surface of wall and applying one coat of cement based paint including corneces, pillars etc complete all as specified and directed.
Demolition RCC Roofs, floors (other than ground floors), beams staircases, landing, chajjas, and similar suspended work complete all as specified and directed.
M&L for use & waste wooden form work (rough finished surfaces ) to sides & soffits of Chajjas, parapets & facia and similar work n. exc 200 mm thick, complete all as specified and directed.
M&L for RCC type B1, 1:2:4 (20 mm graded Stone agg) as in RCC platform complete all as specified and directed.
Mild steel TMT Mild steel bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with theincluding mild steel wire (annealed) not less than 0.9mmdia or securing with clips complete all as specified and directed.
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in 10mm thick screed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
S & F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates,rivetting, etc., n exc 10 kg each brackets, conforming to FE 410-0 or FE 310-0 (Brackets over 10kg each to be measured under `Structural Steel') complete all as specified and directed.
S&F anodised aluminium powder coated (minimum thickness of powder coating 50 micron) frame for doors,windows,ventilators, partition with one or more rebated incl joining cleat for fixing etc. complete all as specified and directed.
S & F Anodiesed aluminium powder coated door shutters aluminimum section weighing 0.55 Kg/m incl necessary joining cleats glazing clips, rubber neoprene packing, handles 2 nos in each doors, hinges, anodiesed aluminium snap beading screw etc complete all as specified and directed.
S & F Anodised aluminium powder coated window and ventilator shutters, side hung type without sash bars, aluminium sections weeighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fitings such as peg stays 150mm long (1 No.) hinge type B-21 100mm long (2 No.) suitable handle (1 No.) complete all as specified and directed.
S&F 5mm thick PVC plain colour PVC sheet in strips & channel feathered at the edges for fixing on Solid PVC Wall Linning, Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of solvent Cement and fixing at site complete all as specified and directed.
S&F 5.5 mm thick sheet glass, ordinary quality in Aluminium door with solar control film 50 micron in squares exc 0.5 sqm each pane complete all as specified and directed.
S&F Brass mortice lock 100 mm,4 levers, vertical type, fixed to cupboard shutters, complete all as specified and directed.
S&F Hydraulic door closer of aluminium die cast body,designation No-3 universal type suitable for door shutter of 851 mm to 1000 mm weight between 61 Kg to 80 kg etc, complete all as specified and directed.
S&F Aluminium tower bolts powder coated , 150 mm long and fixed with steel screws, complete all as specified and directed.
S&F 100mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-22, complete all as specified and directed.
M & L PVC Wall Lining consisting of 5mm thick hollow Plain /wooden grain colour PVC sheet inclusive of solvent cement and fixing at site incl PVC beading of angle, edges etc as per specifications and drawing complete all as specified and directed.
S&F 3mm thick, plain sheet glass ordinary quality and glazing, with oil putty or with wooden beads (supplied alongwith shutters), in squares n.exc 0.50 Sqm complete all as specified and directed.
Dismantling floor ,hearth or wall tiling including cement morter beddind (but not backing removing seviceable tiles to store and rubbish off the premises, complete all as specified and directed.
M&L for Glazed ceramic coloured (colour & shade as approved) tiles non skid of size 400x400x7mm thick as in floor set and jointed in neat cement slurry over and including 15mm thick screed in cement mortar (1:6) and pointed in white cement with pigment to match the colour of tiles complete all as specified and directed.
All as per Item No-above here in before but as on vertical surfaces such as skirting/dado over and including 10 mm thick rendering in cement mortar (1:4), complete all as specified and directed.
Surface dressing n exc 15 cm deep and getting out soft/ loose soil, complete all as specified and directed.
M&L for Hardcore of broken stone gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
M&L for cement concrete type D-2 (1:4:8) 50 mm thick, complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement plaster 1:6 complete all as specified and directed.
M&L Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigments, complete all as specified and directed.
Excavating in post holes (or similer holes) each n. exc. 0.5 Cum. Getting out returning,filling in and ramming earth or broken rubble mixed with earth around in layer not exc.25 cm, complete all as specified and directed.
M&L for cement concrete type C-2 1:3:6 using 40mm graded stone aggergate as in foundations filling and mass concrete complete all as specified and directed.
M&L Pre painted galvatume aluminum zink coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Steel work in tubular trusses 50mm internal dia incl. special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS 11614-1979 grade St-240, complete all as specified and directed.
M&L for Preparation of new steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over priming with a coat of red oxide, zinc chrome primer complete all as specified and directed.
S&F decorative anodised aduminium alloy curtain rails of 20 mm dia brackets fixed with steel screws & PVC rawl plugs, complete all as specified and as directed
Dismantling of brick tiles or terracing tiles single layer laid on roof jointed & pointed in cement mortar complete all as specified and directed
Demolition of un reinforced cement concrete of any description and in any position not otherwise specially provided for complete all as specified and directed.
Dismantling brick tiles laid in double layer jointed & pointed in cement mortar incl removal of grass vegetation complete all as specified and directed.
Dismantling timber scantlings in fillets, rails, posts, rafters, purlins, etc; under 40 sq. cm in each section, fixed in any position as in framed work complete all as specified and directed.
M & L PCC (1:2:4) type B-0 using 12.5mm graded stone agg as in haunching ,kerb in roof or similar work complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed.
M&L for polythene film, 150 micron thick, laid on roofs with 150 mm overlaps complete all as specified and as directed.
M&L 80 mm thick average consolidated thickness mud phuska on flat roofs including 25 mm thick mud plaster and 3 mm thick leeping plaster etc complete all as specified and directed
M&L 40 mm thick brick tiles laid on mud mortar and joints grouted flush in cement mortar 1:3 mixed with 5% of crude oil by weight of cement, on mud phuska complete all as specified and directed
All as per srl item No 52 here-in-before but using old brick tiles retrieved from dismantling (item No 44 & 46 above here-in-before) including cleaning and removal of mortar from tiles complete all as specified and directed
M&L flush pointing to brick laid flat or brick tiles in roofs and paving in cement mortar (1:4) complete all as specified and directed
Supply only integral water proofing compound complete all as specified and directed.
Demolition/taking out mud from the roofs, any thickness, including plastering and leaping etc including removing rubbish upto 500 mtr from the site complete all as specified and directed.
M&L for rendering 10 mm thick in CM (1:4) mixed with integral water proofing compound as per mfg instr over the padding concrete while still the concrete is still green, complete all as specified & directed (For roof treatment)
M&L for water proofing treatment to roof surface including parapet wall comprising with the following course of treatment/ specifications form bottom to top:- (a) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg per sqm over a coat of bitumen primer @ 0.30 ltr per sqm including preparation of roof surfaces complete all as specified and as directed. (b) One layer of APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified. Polymeric membrane shall be taken to a height of 60 cm (minimum) and then inserted inside the groove of parapet walls and shall be finished by a membrane flashing. Note: (i) Laying of APP based membranes shall be done by torch on method or as per manufacturer's instructions. (ii) A minimum overlap shall be 75mm length wise and 100 mm width wise of polymeric membranes respectively and sealed all overlaps and joints as manufacturer's instructions.
M&L for rolled mild steel section as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors ; fixed with angle cleats or other connecting plates conforming to grade Fe 410-W (Gde-E250) quality-A complete all as specified and directed.
S&F Framed mild steel work of grade E-165 (Fe-290) as in framed work such as doors, gates or frame for cooler stand with gusset plates, rails, braces etc, drilled for fixing of sheeting or other covering of door etc, to be prepared for hanging or sliding etc including either hooks and hinges or steel hanging door fittings and hanging and fixing complete all as specified and directed.
S & F Anodised aluminium snap grid frame work for false ceiling complete all as specified and directed.
M&L for Providding and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions, complete all as specified and directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:6) including demolition of brick work or stone/boulder masonary built in cement mortor including all quoins,arches,pillars etc,complete all as specified and directed
M&L for rendering 15 mm thick in cement mortar (1:4) on any face of brick walls or concrete surfaces, finished fair and even including preparation of new plastered or unplastered surfaces and applying two coats of cement based paint over a coat of chalk white primer on walls complete all as specified and directed.
Supply only integral water proofing compound (ISI Marked) complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar (1:6) on any face of brick walls or concrete surfaces, finished fair and smooth without using extra cement including Preparation of new surfaces of wall and applying two coats of white lime wash (white washing) on walls including corneces, pillars etc complete all as specified and directed
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces, complete all as specified and directed.
M&L for Preparation of old painted wood or wood based surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for Preparation of old decorated surface of steel surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
S&F Powder coated of ( any colour ) aluminium window , ventilator etc fixed / sliding or pull and push type in shutter frames or shutters with two/three track sliding aluminium frame of Jindal /Hindalco (or) Equivalent make of approved size, including necessary joining cleats, glazing clips,powder coated aluminium snap beading, screws, including necessary anodised aluminium fittings like handles, hinges, tower bolt etc complete all as specified as per manufacturers instructions. Note: EPDM Rubber beading/gasket measured and paid seperatley.
S&F EPDM Rubber beading around glass in aluminium door/windows /ventilator shutters, complete all as specified and directed.
S&F 140 mm Floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring complete all as specified and as directed.
Roof truss (framed) trussed, purlins crane gantries, rails and fastenings and heavy bracket framing (Beam tee, angle channel or flat sections) inclusing distance pieces,cleats etc Fe 410-W (Gde E-250) quality B, complete all as specified and directed.
M&L 75 mm thick PCC, type D-2, 1:4:8 (40mm graded aggregate) as in sub base flooring without using extra cement complete all as specified and directed.
M&L Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35Grade with grey cement and no pigment used, excluding laying of sand cushioning complete all as specified and as directed.Note :- Sand will be measured and paid seperately
M&L sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L Machine cut kota stone slab flooring 18-20mm thick over 20 mm cement screed base CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing polishing and rounded or chamfered for nosing complete all as specified and directed.
E/M Works Taking down carefully existig copper / alumn point wiring for light / fan / bell / socket 5/15 Amp points complete with fitting and fixtures such as switches, sockets, c/ rosess, holders and bracket fittings with battens / conduits / wires,T/L fittings and making good the disturbed surfaces of walls and roofs etc.and to match with existing colour complete all as specified and directed.
Taking down carefully unserviceable main switches and distribution boards with fuses/ MCB's (single phase or three phase) of any capacity all as specified and directed.
Taking down carefully old unserviceable sub main wiring including meters and making good disturbed surfaces and matching with existing complete all as specified and directed.
S&F Point wiring complete with 1100 volts grade PVC FRLS insulated unsheathed cable of copper conductor, multi stranded of size 1.5 Sqmm, single core, drawn through & including PVC rigid concealed conduit, medium grade of suitable size (not less than 20mm dia) duly ISI marked with all accessories such as bends, reducers, spacers, saddles, junction boxes, bakelite sheets, sizes for mounting switch/sockets, fan regulators etc complete with and including continuous earth wire of size 1.5 Sqmm, single core, PVC FRLS copper conductor, insulated, unsheathed,stranded (Green colour) connected to common earth dolly complete all as specified and directed. for following : (a) One light/fan/bell/Bldg security light point controlled by one single pole one way switch.
(b) One 3 pin 5 Amp socket outlet point controlled by one switch on Independent board.
(c) One 3 pin 5 Amp socket outlet point controlled by one switch on same board.
All as per item No. 81 here-in-before but one 15 Amps socket outlet point controlled by one single pole switch one way and wiring with 2.5 Sqmm PVC insulated,stranded,unsheated copper conductor on independednt board with continuous earth wire of size 2.5 Sqmm green colours PVC insulated, unsheathed,stranded copper conductor cable, complete all as specified and directed.
All as per item No. 81 here-in-before but one 15 Amps socket outlet point controlled by one single pole switch one way and wiring with 4.0 Sqmm PVC insulated,stranded,unsheated copper conductor on independednt board with continuous earth wire of size 4.0 Sqmm green colours PVC insulated, unsheathed,stranded copper conductor cable, complete all as specified and directed.
S&F 6 amps piano flush type , single pole, one way switch urea back piece (IP20), 240V, 50Hz, white in colour, duly ISI marked complete all as specified and directed.
S&F Switch piano flush type 20 amps, single pole one way, white in colour, duly ISI marked complete all as specified and directed.
S&F 6 Amps Socket 2 in 1, Urea backpiece (IP20), white in colour, duly ISI marked complete all as specified and directed.
S&F Socket outlet, UNI, 2 in one 10 Amps & 20 Amps, white in colour, duly ISI marked complete all as specified and directed.
S&F Ceiling rose surface type, 240 volts, 50 Hz, 6A, Pilot 3 plate, white in colour, bakelite 65 x 50mm, 3 terminals duly ISI marked complete all as specified and directed.
S&F batten holder (with metal ring), 240 volts, 50 Hz, 6A, white in colour, duly ISI marked complete all as specified and directed.
S&F rotary stepped type electronic fan regulator for ceiling fan 1200/1400mm size, 240 volts, 6 Amps, 100W, deluxe, white in colour, duly ISI marked complete all as specified and directed.
S&F 20W, 6500 K, 4 feet LED Square tube light fitting, energy efficient fixed to wall/ ceiling etc complete all as specified and directed.
S&F LED bulb of 9/10 watt, B22, 6500K complete all as specified and directed.
S&F LED sleeky bldg street light (Lens) fitting of 35 watts, 6000K, including GI bracket bend to shape made out of GI pipe light grade of 25 mm, size up to 1.2 mtr long etc complete with MS clamps made of 25x3mm MS plate, duly painted with two coats of aluminium paint with nuts/ bolts/ washers and all fixing arrangements to wall/ pole, including connecting up with 2 core copper flexible wire of size 23/00.0076 complete all as specified and directed.
S&F Factory made three phase and neutral Sheet Steel made out of CRCA 1.2 mm thick, powder coated double door vertical distribution board 4 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming and outgoing MCBs and the second for protection of MCBs fitted with colour bus bar of capacity 200 Amps, neutral link, earth bar and din rail suitable for use on 240/415V, 50Hz supply, VTPN DB, partly immersed in wall, including of MCCB 4 pole adjustable thermal & fixed magnetic type 100 Amps, 50Hz, 415 Volts with rupturing capacity 16 KA and making good distrubbed surfaces with matching colour, complete all as specified and directed.
S&F Factory made single phase and neutral Sheet Steel made out of CRCA 1.2 mm thick, powder coated double door vertical distribution board 8 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming and outgoing MCBs and the second for protection of MCBs fitted with colour bus bar of capacity 200 Amps, neutral link, earth bar and din rail. suitable for use on 240V, 50Hz supply, partly immersed in wall and making good distrubbed surfaces with matching colour, complete all as specified and directed.
S&F MCB SPN, 40A - 63Amps, 240 volts, "C" series, 10KA duly ISI marked, in MCB DB, complete with connection testing and commissioning complete all as specified and directed.
S&F MCB SP, 6A-32 Amps, 240 volts, "B" series, 10KA duly ISI marked, in the MCB DB, complete with connection testing and commissioning complete all as specified and directed.
M&L for Sub main wiring with two single core 2x6 sqmm FRLS insulated and unsheathed stranded copper conductor alongwith earth wire 6.0 sqmm drawn in FRLS rigid conduit connected to main board complete all as specified and directed (Two runs cable and one number earth wire and suitable FRLS conduit shall measured together as unit length).
S&F exhaust fan heavy duty with louvers complete of sweep size 300mm, 900 RPM, single phase, with bolts, nuts and washers, size of the bolt 15 cm long 12mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan max 1.5 mtr for giving connection complete all as specified and directed.
Cutting holes making good the distributed surface, grouting nuts for fixing of Exhaust fans complete all as specified and directed.
Fixing or hanging only ceiling fans height upto 3mtr to 5 mtrs ceiling height of bldg including three core FR PVC Insulated & overall round sheathed flexible with PVC, colour of cores are Red, Black & Yellow/ Green is for earthing. Sheath colour is Black of cable size 23/0.0076 complete all as specified and directed. Note : Ceiling fans obtained/ taking down from item Sr No. 78 as above
Earthing complete with galvanized steel plate elecrode of size 60 cm x 60cm x 6.3 mm thick burried directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level. Earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and comman salt, earth lead GI wire of 4mm dia (8 SWG) by means of bolts , nuts, check nuts and washers of galvanised iron with thimbles. The other end of GI earth wire is connected to main switch board and protected by light grade GI pipe of 15 mm bore. provision of 20mm bore light grade GI pipe for watering including GI funnel and wire mesh. Pipe shallbe provided vertically upto top level of earth pit and then taken horrizontally to the earth pit. Cement concrete chamber of PCC ( 1:3:6 ) type C-2using 40 mm graded stone aggregate.The chamber shall be constructed one metre away from edge of earth pit. 50 mm thick pre cast cover of cement conrete (1:2:4) type B-1 using 20 mm graded stone aggregate and MS angle iron 50 x 50 x 6 mm frame including two coats of painting over a red oxide to sxposed steel surfaces. excavation in soft / loose soil, returning filling and removal of surplus soil to a distance of 50 mm as directed and shown in Electrical Plate No- 3 of SSR Part-1 (2009).
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanised iron or steel wire, complete all as specified and directed.
S&F XLPE insulated, armoured, 1100 volts grade, heavy duty cable of size 35 Sqmm nominal cross section, 4 core, aluminium conductor, served with inner sheathing of galvanized steel wire or tape and over-all PVC sheathed in service connections, laid in trenches, duct, through pipe, in floor, on pole including jointing with double compression copper stain less steel gland at DBs and testing, complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep and not exc 10 Sqm on plan,for laying of cable and getting out, complete all as specified and directed.
M&L Dry and clean fine sand for cable cushioning to underground cable protection, complete all as specified and directed. (Excavation and earth work measured separately). Note- Punned down thickness shall be measured.
S&F Cover to underground cable with one layer of bricks using sub class ‘B’ bricks (old size) laid flat across the cable complete all as specified and directed. (Excavation and earth work measured separately).
Returning, filling in, earth including spreading, leveling watering and well ramming in layers each not exceeding 25cm thick each layer, complete all as specified and directed.
Removal of surplus soil to a distance not exc. 50 metre and depositing where directed at a level not exc. 1.5 metre above the starting point complete all as specified and directed.
S&F Mild steel galvanised pipe, light grade, 40 mm nominal bore for passing of cable, fixed to poles/walls, laid under floor/road crossings, complete with and including clamps socket & elbow etc complete all as specified and directed.
S&F Bell push flush, type 6 amp single pole one way, white in colour, duly ISI marked complete all as specified and directed.
S&F Door Bell, AC, 230 volts, single pole, white in colour, duly ISI marked complete all as specified and directed.
Supply and fixing LED light fitting 1 x 20 Watt, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with highefficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Supply & Fixing in replacement Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole 20 Amp MCB of 'C' series complete all as specified and directed by Engr in Charge.
S&F Factory made single phase and neutral Sheet Steel made out of CRCA 1.2 mm thick, powder coated double door vertical distribution board 4 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming and outgoing MCBs and the second for protection of MCBs fitted with colour bus bar of capacity 200 Amps, neutral link, earth bar and din rail. suitable for use on 240V, 50Hz supply, partly immersed in wall and making good distrubbed surfaces with matching colour, complete all as specified and directed.
Supply and fix Air circulator wall mounted fans 230 volts single phase osciallating of size 450 mm sweep with 80 Cum/min air delivery, Hi speed fan, plastic body & blades, pull cords for speed regulation & oscillation, mounting with bolts, nuts and including provision of PVC flexible copper conductor cable of size 23/0.0076 three core from ceiling rose to air circulator fan complete all as specified and directed.
S&F as in repairs XLPE insulated, armoured,1100 volts grade, heavy duty cable of size 35 Sqmm nominal cross section, 3.5 core, flat or circular, PVC FRLS insulated aluminium conductor, served with inner sheathing of galvanized steel wire or tape and over-all PVC FRLS sheathed in service connections, laid in trenches, duct, through pipe, in floor, on pole including jointing and testing, complete all as specified and directed.
S&F ceiling fan 1200mm sweep, AC single phase 230 Volts 50Hz including provision of flexible cable 3 core copper conductor of size 23/0.0076 of suitable length from ceiling rose to ceiling fan upto 1.5 mtr for giving connection and all hanging arrangement i.e. standard down rod, hanging clamp, with rubber real nuts bolts, spring washers and locking of splite pin, plastic canopy with screw compete without fan regulator and marking of MES nos with black synthetic enameled paint complete all as specified and directed.
S&F MCB SPN, 40 Amps, 240 volts, "B" series, 10KA duly ISI marked, complete all as specified and directed.
Suplying and fixing in repair 1100 volts grade heavy duty 6 Sq mm two core cable PVC insulated aluminium Solid conductor, served with inner shething of PVC sheathed in service conections suspended by insulating hangers and procelean beat not more than I metre apart including 4Sq mm suspension wire, one twin core cable flat or circular complete all as specified and directed.
Supply and fix Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 10 KVA, complete all as specified and directed.
Supply and lay XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 25 Sqmm 4 core complete all as specified and directed.
supply, installation, testing and commissioning factory made, LT bus bar panel board cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts.The panel board shall be made of 3.15 thick CRCA sheet (Min size 0.6 m x 0.5 m x 0.35 m ) with Synthetic enemal Paint both side. Base frame of the panel shall be made of angle iron of size 50 x50 x 6mm of upto 1/2 mtr hight from GL& 1/2 mtr for Below GL in PCC (1:3:6) type C-2 using 40 mm stone aggregates comprising of following:- The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with and comprising of the following:- (i) Epoxy insulated common aluminium bus bar of capacity 200 Amp TPN each with Color Coding , including aluminium lugs to connect the cable. (ii) MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 16 KA-01 No (For main Incomming ) complete all as specified and directed.
S&F MCB TP 40 Amps, 240 volts, "B" series, 10KA duly ISI marked, complete all as specified.
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6.3 mm thick buried directly in ground (Preferably in vertical position) earth pit not less than 2.25 metre below normal ground level with top edge of the earth plate not less 1.5 metre (BGL) connected to galvanized iron earth strip 32 x6 mm by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 50mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 50 mm bore “light grade” galvanized iron protection pipe for earth strip 32 x6 mm upto 5m length, charcoal, common salt, complete all as shown in EP No 1 of SSR 2009 Part-I, connected to test point complete, all as specified and testing on completion, complete all as specified and directed. Note : GI earth strip 32 x6 mm more than 7.5 m will be measured and paid separately.
M/s Harkesh Kumar Bansal
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .