Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.5 CrAccepted-AOC 81 ARYA NAGAR ASSANDH ROAD PANIPAT HARYANA 132103 | PANIPAT | HARYANA | 132103 | ₹8.5 Cr | L1 | Accepted-AOC Award |
| 2 | L2₹9.0 Cr+₹48.7 L (5.71%)Rejected-Finance | ₹9.0 Cr+₹48.7 L (5.71%) | L2 | Rejected-Finance Rejected |
| 3 | L3₹9.2 Cr+₹70.3 L (8.24%)Rejected-Finance HSVP PANCHKULA | PANCHKULA | HARYANA | 133301 | ₹9.2 Cr+₹70.3 L (8.24%) | L3 | Rejected-Finance Rejected |
| 4 | L4₹9.3 Cr+₹79.9 L (9.37%)Rejected-Finance H NO 1100 SECTOR 3 124001 | ROHTAK | HARYANA | 124001 | ₹9.3 Cr+₹79.9 L (9.37%) | L4 | Rejected-Finance Rejected |
| 5 | L5₹9.4 Cr+₹88.0 L (10.3%)Rejected-Finance 411 URBAN ESTATE SECTOR 8 PART 2 KARNAL KARNAL HARYANA 132001 KARNAL HARYANA 132001 | KARNAL | HARYANA | 132001 | ₹9.4 Cr+₹88.0 L (10.3%) | L5 | Rejected-Finance Rejected |
Tender Value
₹9.6 Cr
EMD Value
₹19.3 L
Closing Date
10 Jul 2024, 4:00 pmClosed
SANJAY SHARMA
Panipat PHED No. 2
AUGMENTATION OF WATER SUPPLY SCHEME BY INSTALLING 9 TUBE WELLS, 2 BOOSTING STATIONS and LAYING THE DISTRIBUTION NETWORK IN BALANCE AREA OF MC AT SAMALKHA TOWN
2024_HRY_376646_1
20244B92B97B F525 4806 9699 1767EB72C79A574PUH
Open Tender
Civil Works
Works
365 days
Samalkha
2 documents required · 2 mandatory
₹20,000
₹19.3 L
Yes
16 Aug 2024
12 Jun 2024
11 Jul 2024
12 Jun 2024
10 Jul 2024
12 Jun 2024
Amount
HT. ALLUMINIUM CABLE: Supply erection testing of standard make XLPE 3 core HT / 11 KV grade ISI marked Stranded compact circular aluminium conductor, conductor screen with extruded semi conducting compound, XLPE insulated, insulation screening with extruded semi conducting compound in combination with copper tape, cores laid up, innersheath of PVC, galvanised steel flat strip armoured, and overall PVC sheathed cable conforming to is 7098 (part-2) 2011 with up to date amendments for making following connection a) from G.O switch to metering equipment . b) from metering equipment to transformer complete in all respect. Make: Indian Cables Ltd./ Polycab / RR Cables / CAPP / Finolex / Havells / Gloster / Universal / Fort Gloster Industries Ltd./ Indian Cable Co. / Asian Cables Corporation Ltd 35 Sqmm sizet.
LT CABLE ALLUMINIUM: Supply, erection, testing and commissioning of IS marked 3.5 core Cables, Solid Aluminum conductor up to 10sqmm and balance stranded conductor, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Aluminium wire for single core up to 70sqmm and balance Aluminium strip, Glavanised wire for cables up to2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip) extruded PVC type ST2 Outer sheathed, 650/1100V grade as per IS7098 (Part-1) 1988 with up to date amendments along with all accessories complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables / CAPP / Gloster / Universal / Fort Gloster Industries Ltd./ Asian Cables Corporation Ltd. 35 Sqmm size
COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-incharge complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables / CAPP / Gloster / Universal / Fort Gloster Industries Ltd./ Asian Cables Corporation Ltd 16 mm2 3core
Provision for providing and fixing flow meter with electronic display on delivery pipe inside pump chamber complete in all respects.
COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-incharge complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables / CAPP / Gloster / Universal / Fort Gloster Industries Ltd./ Asian Cables Corporation Ltd 10 mm2 3core
Providing and fixing of 15 mm nominal diameter water meter as per IS 779:1994 Inferential type dry dial, mechanical driven, non megnatic drive, straight reading cyclometer type, 7-inline consequent digits with one centre point for easy reading complete in all respect.
FHTC: Making functional househlod tap connections including dismentling and restoration of existing CC/IPB Road / street, digging suitable size pit, trench for connecting line. Supply, erection and commossioning of 10 mm i/d brass / Gun metal ferrule, 3.00 m long IS marked 15 mm i/d G.i pipe class B including all fittings as per specifications and entire satisfaction of Engineer-in-charge complete in all respect.
Supplying, erection, testing and commissioning Variable frequency drive for 30 HP Submersible Motor Compatible to work with cable length of 300 meters and to ensure that there is no voltage drop , Variable frequency drive IP66 with mains Disconnect having Modbus Communication and designed at 50 Degree Celsius without any deration with inbuilt real time clock for time assistance. Variable frequency drive All Electronic cards should be 3C3 Coated. Variable frequency drive with Dual DC choke at both the Limbs with 5 % Impedance. Variable frequency should be having all protection features like Dry Run detection, Deragging, Automatic energy optimization, Low flow detection, sleep mode, complete in all respect including earthing and its connection, erection and commissioning complete in all respect to the entire satisfaction of engineer in charge.
Supplying, erection, testing and commissioning Variable frequency drive for 25 HP Submersible Motor Compatible to work with cable length of 300 meters and to ensure that there is no voltage drop , Variable frequency drive IP66 with mains Disconnect having Modbus Communication and designed at 50 Degree Celsius without any deration with inbuilt real time clock for time assistance. Variable frequency drive All Electronic cards should be 3C3 Coated. Variable frequency drive with Dual DC choke at both the Limbs with 5 % Impedance. Variable frequency should be having all protection features like Dry Run detection, Deragging, Automatic energy optimization, Low flow detection, sleep mode, complete in all respect including earthing and its connection, erection and commissioning complete in all respect to the entire satisfaction of engineer in charge.
Supplying, erection, testing and commissioning Variable frequency drive for 20 HP Horizontal Pump Motor Set Compatible to work with cable length of 300 meters and to ensure that there is no voltage drop , Variable frequency drive IP66 with mains Disconnect having Modbus Communication and designed at 50 Degree Celsius without any deration with inbuilt real time clock for time assistance. Variable frequency drive All Electronic cards should be 3C3 Coated. Variable frequency drive with Dual DC choke at both the Limbs with 5 % Impedance. Variable frequency should be having all protection features like Dry Run detection, Deragging, Automatic energy optimization, Low flow detection, sleep mode, complete in all respect including earthing and its connection, erection and commissioning complete in all respect to the entire satisfaction of engineer in charge.
Gas Chlorination: Providing, fixing,testing and commissioning of Vacuum Gas Chlorination system of rating 2000 grams per hour having the control of gas 20th part of max. dose and which can start working automatically on switching in the supply of water at the site of boosting station consisting of following parts:- a) vacuum regulator b) flow meter with control valve assembly c) Differential pressure regulator d) Pressure relief valve e) Vacuum relief valve f) Online Chlorine Analyzer for chlorine and turbidity of water g) Auto Shut off Valve h) Automatic Switchover System (1 Working plus 1 Standby) i) 2 nos. filled of chlorine cylinders of capacity 100 kg duly certified and approved by BIS and explosive department Govt. of India j) Chlorine Gas Detection System(chlorine leak detector with hooter and sensor) k) Chlorine Gas Scrubber including spanner with cylinder opening key, 2 set connectors, iron cage guard, safety equipments consisting of chlorine mask with canister and complete installation of the equipments and all other works contingent thereto as per detailed specification as per Annexure A and as per satisfaction of Engineer-In-Charge including operation and maintenance of entire system during defect liability period of 1 year after successful trial run period of 3 months and thereafter operation and maintenance for 5 years.
Bidder Name
Amount
Ram Narain Jain Contractor (GSTN-06ACLPJ0885F1ZK) BID ID -1102445
Kulbir Singh Contractor (GSTN-06ATZPS6352H1ZW) BID ID -1108977
Himmat Singh Contractor(GSTN-NA)--1112071
Rajesh Kadiyan Contractor(GSTN-NA)--1113641
kapil engineering company(GSTN-NA)--1114078
Sh.Jasveer Singh Dahiya(GSTN-NA)--1114033
RAJEEV KUMAR GOEL CONTRACTORS(GSTN-NA)--1112142
ARUNESH GUPTA(GSTN-NA)--1113438
Ram Narain Jain Contractor
Kulbir Singh Contractor
Himmat Singh Contractor
ARUNESH GUPTA
Rajesh Kadiyan Contractor
RAJEEV KUMAR GOEL CONTRACTORS
kapil engineering company
Himmat Singh Contractor
Sh.Jasveer Singh Dahiya
RAJEEV KUMAR GOEL CONTRACTORS
Kulbir Singh Contractor
Ram Narain Jain Contractor
ARUNESH GUPTA
kapil engineering company
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .