| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹69.8 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹75.6 L+₹5.8 L (8.33%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹84.7 L+₹14.9 L (21.3%)Rejected-AOC | L3 | Rejected-AOC Rejected |
Tender Value
₹60.1 L
EMD Value
₹92,600
Closing Date
22 Jul 2021, 11:00 amClosed
Executive Engineer
JSV Division Rohru
SH Repalcement of pumping machinery T Laying jointing of R Main 50 mm dia 80 Rmt GMS tube 20mm dia 1600 Rmt 32mm dia 2700 Rmt 1 No Storage tank of capcity 10000 ltr Common Header P F fencing pannel Booster pump Providing household conne
2021_HPIPH_49807_1
JSV-RD-AB-Tender 21-3661-85
Open Tender
Civil Works - Others
Item Rate
180 days
Rohru Town
Tender Document
8 documents required · 8 mandatory
₹800
Yes
EE Rohru
₹92,600
Yes
16 Sept 2021
13 Jul 2021
22 Jul 2021
13 Jul 2021
22 Jul 2021
13 Jul 2021
Amount
Stage-1stSupply of horizontal spindle,horizontal split casing Single/Multistage centrifugal pumps of standarad make such as KSB/Mather & Platt/Jyoti/Kirloskar conforming to BIS 1520-1980 (latestwith upto date ammendments) read with BIS 9137-1978 or latest to handle clear water having turbidity 50 ppm. with impelleres,casing ring & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate to Kirlokar/NGEF/Crompton/ Siemen/Jyoti slip ring/squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below. 60 BHP 60x1=60 BHP
Supply of suitable oil immersed star delta starter/ATS/stator rotor starter of standarad make such as MEI/Kilburn/Jyoti/ Siemens cnonforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slipriing motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling . Oil immersed star-delta-starter Note:- Star - delta - starter upto 37.5 KW , ATS between 37.5 KW to 50 KW and stater rotor starter with slipring motor beyond 50 KW.
Providing M S sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angale iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessaries with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer in charge.
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediatly after the power meter of HPSEB. 100 Amp
Busbar chamber having 3 copper bars of suitable rating for full length equal to wirdth of board of 3 live phases and one copper bar of half reating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date ammendments.
MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in comming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release. 100Amp
3 phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date ammendments.
Earth leakage circuit breaker of requcemended (Kilburn/L&T/MET/GEC as per BIS-2516-1977with upto date ammendments and of suitaible range with which should have control box, oprating handel and trip/reset bush button on/ off indicators, re-indicating off spring conditionof the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breakeron occurance of earth fault on/ of breaker load side.
Hour run meter of reputed make of four digit capacity conforming to BIS-722(latest edition)/recommendations.
Suitable three phase voltage monitor relay with all protections & usual indicators with electricalsirens against single phasing,no voltage,high voltage & overloading & phase voltage difference
Change over Switch of reputed make & suitable capacity
Single phase preventor of reputed make & suitable capacity
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/ of reputed make of suitable size cast iron/cast steel double flanged sluice valve having size equal to delivery of pump and capable of with standing nominal seat pressure of 52 kg/cm^2 Class=300ASA MAKE=Cast Steel NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammend--ments.However if the seat pressure exceeds the limits prescribed in BIS 780 then thesluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) or class 600 ASA (seat pressure 104 Kg/Cm2)as per BS 1414(API 600) .
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader of suitable size cast iron/ cast steel double flanged swing check type reflux valve having bye pass arrangement & size equal to delivery of pump for withstanding nominal seat pressure of 52 kg/cm^2 50mm dia CLASS=300ASA MAKE=Cast Steel NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammend--ments.However if the seat pressure exceeds the limits prescribed in BIS 780 then thesluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) or class 600 ASA (seat pressure 104 Kg/Cm2)as per BS 1414(API 600) .
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader of suitable size cast iron/Cast Steeldouble flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/main for withstanding nominal seat pressure of 52 kg/cm^2 CLASS=300ASA MAKE=Cast Steel NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammend--ments.However if the seat pressure exceeds the limits prescribed in BIS 780 then thesluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) or class 600 ASA (seat pressure 104 Kg/Cm2)as per BS 1414(API 600) .
Supply of Kirloskar/Jyoti/Standard/Kilburn make cast irom flanged screwed type foot valve with strainer of dia equal to dia of suction pipe conforming to BIS 4038-1986 or latest with up to date ammendments.
P/L suitable size copper PVC insulated armoured power 3 1/2 core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments Siemen/Gloster/ICC make from meter of HPSEB to OCB & from OCB to Busbar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor .The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.. 25 SQMM
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554(part I)-1988 or latest with up to date ammendments Siemen/Gloster/ICC make from switch to starter & starter to motor (one cable for carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. 16 SQMM
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments for above motors & other electrical equipment.
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/ Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/ Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer. Shunt capacitor 9 KVAR
Supply of standarad make 100mm dia circular dial pressure gauge of suitable range Fiebeg/ Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
Errection of all equipments from S.No. 1 to 4, 6 & 6 i/c cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Stage 2nd Supply of horizontal spindle,horizontal split casing Single/Multistage centrifugal pumps of standarad make such as KSB/Mather & Platt/Jyoti/Kirloskar conforming to BIS 1520-1980 (latestwith upto date ammendments) read with BIS 9137-1978 or latest to handle clear water having turbidity 50 ppm. with impelleres,casing ring & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate to Kirlokar/NGEF/Crompton/ Siemen/Jyoti slip ring/squirrel cage screen protected drip proofinduction electric motor suitable for operation on the data given below.1 set of 60.00 BHP 60x1=60 BHP
Supply of suitable oil immersed star delta starter/ATS/stator rotor starter of standarad make such as MEI/Kilburn/Jyoti/ Siemens cnonforming to BIS-8544-1979 latest with up to date ammendments for squirrelcage/slipriing motor (make to be specified by the tenderers) mounted on panel board withmagnetic type over load release & dashpot,time lag,under voltage release with initial oil filling . Oil immersed Star-deleta-starter Note:- Star - delta - starter upto 37.5 KW , ATS between 37.5 KW to 50 KW and stater rotor starter with slipring motor beyond 50 KW.
Providing M S sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angale iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessaries with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer in charge.
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and havingcapacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediatly after the power meter of HPSEB.100 Amp
Busbar chamber having 3 copper bars of suitable rating for full length equal to wirdth of board of 3 live phases and one copper bar of half reating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date ammendments.
MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in comming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release. MCCB 100 Amp
3 phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date ammendments.
Earth leakage circuit breaker of requcemended (Kilburn/L&T/MET/GEC as per BIS-2516-1977with upto date ammendments and of suitaible range with which should have control box, oprating handel and trip/reset bush button on/ off indicators, re-indicating off spring conditionof the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breakeron occurance of earth fault on/ of breaker load side.
Hour run meter of reputed make of four digit capacity conforming to BIS-722(latest edition)/recommendations.
Suitable three phase voltage monitor relay with all protections & usual indicators with electricalsirens against single phasing,no voltage,high voltage & overloading & phase voltage difference
Change over Switch of reputed make & suitable capacity
Single phase preventor of reputed make & suitable capacity
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/ of reputed make of suitable size cast iron/cast steel double flanged sluice valve having size equal to delivery of pump and capable of with standing nominal seat pressure of 52 kg/cm^2 CLASS=300 ASA MAKE NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammend--ments.However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) or class 600 ASA (seat pressure 104 Kg/Cm2) as per BS 1414(API 600) .
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader of suitable size cast iron/ cast steel double flanged swing check type reflux valve having bye pass arrangement & size equal to delivery of pump for withstanding nominal seat pressure of 52 kg/cm^2 50 mm dia CLASS=300ASA MAKE=Cast Steel NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammend--ments.However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) or class 600 ASA (seat pressure 104 Kg/Cm2) as per BS 1414(API 600) .
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader of suitable size cast iron/Cast Steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/main for withstanding nominal seat pressure of 52 kg/cm^2 CLASS=300ASA MAKE=Cast steel NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammend--ments.However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) or class 600 ASA (seat pressure 104 Kg/Cm2)as per BS 1414(API 600) .
Supply of Kirloskar/Jyoti/Standard/Kilburn make cast irom flanged screwed type foot valve with strainer of dia equal to dia of suction pipe conforming to BIS 4038-1986 or latest with up to date ammendments.
P/L suitable size copper PVC insulated armoured power 3 1/2 core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments Siemen/Gloster/ICC make from meter of HPSEB to OCB & from OCB to Busbar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor .The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.. 25 SQMM
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554(part I)-1988 or latest with up to date ammendments Siemen/Gloster/ICC make from switch to starter & starter to motor (one cable for carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. 16SQMM
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments for above motors & other electrical equipment.
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/ Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/ Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.Shunt capacitor 9 KVR
Supply of standarad make 100mm dia circular dial pressure gauge of suitable range Fiebeg/ Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
Errection of all equipments from S.No. 1 to 4, 6 & 6 i/c cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Stage-1st Supply of horizontal spindle,horizontal split casing Single/Multistage centrifugal pumps of standarad make such as KSB/Mather & Platt/Jyoti/Kirloskar conforming to BIS 1520-1980 (latestwith upto date ammendments) read with BIS 9137-1978 or latest to handle clear water having turbidity 50 ppm. with impelleres,casing ring & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate to Kirlokar/NGEF/Crompton/ Siemen/Jyoti slip ring/squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below. 1 set of 30 BHP 30x1=30 BHP
Supply of suitable oil immersed star delta starter/ATS/stator rotor starter of standarad make such as MEI/Kilburn/Jyoti/ Siemens cnonforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slipriing motor (make to be specified by the tenderers) mounted on panel board withmagnetic type over load release & dashpot,time lag,under voltage release with initial oil filling . Oil immersed Star-delta-starter Note:- Star - delta - starter upto 37.5 KW , ATS between 37.5 KW to 50 KW and stater rotor starter with slipring motor beyond 50 KW.
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediatly after the power meter of HPSEB. 100 Amp
Busbar chamber having 3 copper bars of suitable rating for full length equal to wirdth of board of 3 live phases and one copper bar of half reating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date ammendments.
MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in comming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release. M.C.C.B 100 Amp
3 phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date ammendments.
Earth leakage circuit breaker of requcemended (Kilburn/L&T/MET/GEC as per BIS-2516-1977with upto date ammendments and of suitaible range with which should have control box, oprating handel and trip/reset bush button on/ off indicators, re-indicating off spring conditionof the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breakeron occurance of earth fault on/ of breaker load side.
Hour run meter of reputed make of four digit capacity conforming to BIS-722(latest edition)/recommendations.
Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing,no voltage,high voltage & overloading & phase voltage difference
Change over Switch of reputed make & suitable capacity
Single phase preventor of reputed make & suitable capacity
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/ of reputed make of suitable size cast iron/cast steel double flanged sluice valve having size equal to delivery of pump and capable of with standing nominal seat pressure of 52 kg/cm^2 NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammend--ments.However if the seat pressure exceeds the limits prescribed in BIS 780 then thesluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) or class 600 ASA (seat pressure 104 Kg/Cm2)as per BS 1414(API 600) . CLASS=300 ASA MAKE= Cast Steel
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader of suitable size cast iron/ cast steel double flanged swing check type reflux valve having bye pass arrangement & size equal to delivery of pump for withstanding nominal seat pressure of 52 kg/cm^2 NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammend-ments.However if the seat pressure exceeds the limits prescribed in BIS 780 then thesluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) or class 600 ASA (seat pressure 104 Kg/Cm2) as per BS 1414(API 600) . 50MM Dia CLASS =300ASA MAKE=Cast Steel
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader of suitable size cast iron/Cast Steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/main for withstanding nominal seat pressure of 52 kg/cm^2 NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammend--ments.However if the seat pressure exceeds the limits prescribed in BIS 780 then thesluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) or class 600 ASA (seat pressure 104 Kg/Cm2) as per BS 1414(API 600) . CLASS =300ASA MAKE=Cast Steel
Supply of Kirloskar/Jyoti/Standard/Kilburn make cast irom flanged screwed type foot valve with strainer of dia equal to dia of suction pipe conforming to BIS 4038-1986 or latest with up to date ammendments.
P/L suitable size copper PVC insulated armoured power 3 1/2 core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments Siemen/Gloster/ICC make from meter of HPSEB to OCB & from OCB to Busbar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor .The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.. 25 SQMM
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554(part I)-1988 or latest with up to date ammendments Siemen/Gloster/ICC make from switch to starter & starter to motor (one cable for carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. 16 SQMM
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments for above motors & other electrical equipment. Shunt capacitor 9 KVAR
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/ Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/ Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer. Shunt capacitor 9 KVAR
Supply of standarad make 100mm dia circular dial pressure gauge of suitable range Fiebeg/ Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
Errection of all equipments from S.No. 1 to 4, 6 & 6 i/c cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Stage 2nd Supply of horizontal spindle,horizontal split casing Single/Multistage centrifugal pumps of standarad make such as KSB/Mather & Platt/Jyoti/Kirloskar conforming to BIS 1520-1980 (latestwith upto date ammendments) read with BIS 9137-1978 or latest to handle clear water having turbidity 50 ppm. with impelleres,casing ring & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate to Kirlokar/NGEF/Crompton/ Siemen/Jyoti slip ring/squirrel cage screen protected drip proofinduction electric motor suitable for operation on the data given below. 1set of 30.00 BHP 30x1=30 BHP
Supply of suitable oil immersed star delta starter/ATS/stator rotor starter of standarad make such as MEI/Kilburn/Jyoti/ Siemens cnonforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slipriing motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling . Note:- Star - delta - starter upto 37.5 KW , ATS between 37.5 KW to 50 KW and stater rotor starter with slipring motor beyond 50 KW. Oil immersed Star -delta-starter
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediatly after the power meter of HPSEB. 100 Amp
Busbar chamber having 3 copper bars of suitable rating for full length equal to wirdth of board of 3 live phases and one copper bar of half reating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date ammendments.
MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in comming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release. M.C.C.B 100 Amp
3 phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date ammendments.
Earth leakage circuit breaker of requcemended (Kilburn/L&T/MET/GEC as per BIS-2516-1977with upto date ammendments and of suitaible range with which should have control box, oprating handel and trip/reset bush button on/ off indicators, re-indicating off spring conditionof the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breakeron occurance of earth fault on/ of breaker load side.
Hour run meter of reputed make of four digit capacity conforming to BIS-722(latest edition)/recommendations.
Suitable three phase voltage monitor relay with all protections & usual indicators with electricalsirens against single phasing,no voltage,high voltage & overloading & phase voltage difference
Change over Switch of reputed make & suitable capacity
Single phase preventor of reputed make & suitable capacity
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/ of reputed make of suitable size cast iron/cast steel double flanged sluice valve having size equal to delivery of pump and capable of with standing nominal seat pressure of 52 kg/cm^2 NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammend--ments.However if the seat pressure exceeds the limits prescribed in BIS 780 then thesluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) or class 600 ASA (seat pressure 104 Kg/Cm2) as per BS 1414(API 600) . CLASS=300ASA MAKE=Cast Steel
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader of suitable size cast iron/ cast steel double flanged swing check type reflux valve having bye pass arrangement & size equal to delivery of pump for withstanding nominal seat pressure of 52 kg/cm^2 NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammend--ments.However if the seat pressure exceeds the limits prescribed in BIS 780 then thesluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) or class 600 ASA (seat pressure 104 Kg/Cm2) as per BS 1414(API 600) . 50 mm dia CLASS=300 ASA MAKE= Cast Steel
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader of suitable size cast iron/Cast Steeldouble flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/main for withstanding nominal seat pressure of 52 kg/cm^2 NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammend--ments.However if the seat pressure exceeds the limits prescribed in BIS 780 then thesluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) or class 600 ASA (seat pressure 104 Kg/Cm2) as per BS 1414(API 600) . CLASS=300 ASA MAKE=Cast Steel
Supply of Kirloskar/Jyoti/Standard/Kilburn make cast irom flanged screwed type foot valve with strainer of dia equal to dia of suction pipe conforming to BIS 4038-1986 or latest with up to date ammendments.
P/L suitable size copper PVC insulated armoured power 3 1/2 core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments Siemen/Gloster/ICC make from meter of HPSEB to OCB & from OCB to Busbar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor .The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.. 25 SQMM
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554(part I)-1988 or latest with up to date ammendments Siemen/Gloster/ICC make from switch to starter & starter to motor (one cable for carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. 16 SQMM
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments for above motors & other electrical equipment.
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/ Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/ Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer. Shunt capacitor 9 KVAR
Supply of standarad make 100mm dia circular dial pressure gauge of suitable range Fiebeg/ Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
Errection of all equipments from S.No. 1 to 4, 6 & 6 i/c cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Excavation in foundation trenches(for pipes & pits) upto all depths in all class fication of earth work such as pick work, jumper work, saturated soil including bailling and pumping out water, blasting soft/hard rock or chieselling soft/hard rock where blasting is protibited in all lifts including trimming and dressing of sides, leveling of beds to correct grade i/c shoring/strutting, planking,timbering & dewatering wherever required, stacking the useable & unuseable material/soil separately & after laying jointing & testing of pipes, returning the useable soil in trenches in 15cm. layers including consolidating of such deposoited layer by ramming & watering & then disposing of all surplus excavated soil/unuseable material as directed within all leads and lifts including restoration unmetalled surfaces to its original condit on & including cost of diversion for traffic, night signal, fixing caution boards crossing over trenches for access to houses, fencing etc. complete in all respects within all leads & lifts as per direction of Engineer-in-charge.
Providing and laying cement concrete work 1:3:6(1cement:3approved sand:6approved graded stone agg.20mm nominal size)& curing complete excluding cost of form work in foundation and plinth within all leads and lifts and as directed by the Engineer-in-charge.
Providing and laying cement concrete 1:.1.5 :3( 1cement: 1.5 sand: 3graded stone aggregate 20 mm nominal size )and curing complete excluding the cost of form work and reinforcement in:-
Foundation and plinth Bed and wall ncluding attached buttress, pillasters and their caps and string cources etc. upto floor two level within all leads and lifts and as directed by the Engineer-in-charge
ii) Walls(any thickness but ot less than 0.1 mtr thickness) attached pilasters, buttresses, plinth and string courses etc. from top of foundation level up to floor two level.
Providing mild steel/tor steel for RCC work including bending binding and placing in p[osition complete upto floor two level within all leads and lifts and as directed by the Engineer-in-charge.
Providing form work with steel plate 3.15mm thick welded with angle iron frames 30x30x5mmso as give a fair finish i/c centring, shuttering, ¢ring below supporting floor to ceiling not exceeding 4mtrs. &removal of the same for in-situ reinforced concrete & plain concrete work in:
Vertical surface such as wall(any thickness) partitions and the likeincluding attached pillasters, buttresses, plinth and string cources and thelike within all leads and lifts.
Flat surface such as soffits of suspended floor, roofs, landing and the likefloor etc. upto 200mm in thickness within all leads and lifts.
Edges of slab and breaks in floors and walls under 20cm. Wide within all leads and lifts.
10mm thick cement plaster on fair sides of brick/stone masonery convrete walls for interior plastering upto floor two level including arises internal rounded angles not exceeding 80mm girth in cm 1:3 (1cement:3sand)within all leads and lifts and as directed by the Engineer-in-charge.
White washing with lime on undecorated wall surfaces(two coats) to give an even shade i/c thoroughly brooming the surface to remove all dust dirt & other foreign matter within all leads and lifts and as directed by the Engineer-in-charge.
Providing and fixing (M.S.Sheet &Angle iron) 600X600 mm dia man hole cover with frame & cantrolling chamber for wheel valve compelete. In all respect i.e locking arrangement etc.( not less than 35 kg each) and angle iron stir case for up & donw (not less than 75kg)
Providing and fixing GMS ventilating pipe/ over flow pipe( 25 to 32) mm dia.incluing all filling as req.
Prov. and fixing GMS tubes of following dia in walls, floors etc. including tube fittings and making the wall, floors etc. good. i.e welding with one feets 25mm flat iran both side of req.pipes. 25 to 32 mm
Providing & fixing cantrolling arrangement with( 25 to 32) mm dia wheel valve i/c all type of tube fitting compelete.
Providing and laying cement concrete 1:2:4(1cement:2 approved sand:4approved graded stone agg. 20mm nominal size) & curing complete excluding cost of form work in foundation and plinth:
In suspended floor roofs landing shalves & their support balconies,beams, girders bressumers cantilevers upto floor two level
Manufacturing and fixing wheel box MS chamber of size 60x60x30 CM with M.S Sheet (2.50 mm or (12 B.G.) thick) duly welded with angle iron of Angles Iron 40x40x5mm and also provided extra length of 250mm of same angle (as tee) in the bottom of all four legs for embending in cement concrete C.C. 1 :2 :4 and top opening will provide with hinges with lock arrangement etc.complete and also providing hole on three sides of chamber for crossing different size of pipes and as per satisfaction of Engineer-in-charge including entire carriage of material upto all leads and lifts
Making of Common header for distribution system of water at Storage Tanks including all fitting and fixing as per drawing etc.with all leads and lifts as per direction and satisfactions of Engineer in charge
Supply of horizontal spindle,horizontal split casing Single/Multistage centrifugal pumps of standarad make such as KSB/Mather & Platt/Jyoti/Kirloskar conforming to BIS 1520-1980(upto date ammendments) read with BIS 9137-1978 or latest to handle clear water having turbidity 50 ppm. with impelleres,casing ring & shaft sleeves of bronze, shaft of steel in CI casing of suitable capacity coupled directly through a flexible coupling on a common base plate to Kirlokar/NGEF/Crompton/ Jyoti slip ring/squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below. (10 HP)
Providing and laying cement concrete 1:6:12 (1 cement:6 sand :12graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation & plinth in brest & R/wall
R/R masonery/Polygonal Mrubble Masonery (Uncoursed /Brought to courses) with hard stone of approved quality in foundation and plinth i/c levelling up with in C.C nominal size) at plinth level in cm 1:6 (1cement:6sand)1:6:12(1cement:6sand:12 aggregate) 20mm
Manufacuring and supplying of fencing pennel size 2.30x1.30 mtr of jali 25x25mm welded to M.S. Black tube of 32mm dia of 14 guage mm thick with MS flat 20x3 mm welded all arround the pipe pennel 2 nos on both sides and providing hold fast 7 nos of MS Flat of 32x3mm thickness having consisting of tee of size 15x15 cms tee acting as hold fast painting red oxide paint complete to all respect including cutting ewlding and as per the direction of engineering in charge
Trenching Laying and jointing in trences G,M,S, tube (earth work in treanches to be measured and paid for separately) including all leads and lifts and as directed by the Engineer-in-charge.
20 mm dia (twenty milimeters) nominal size (L)
32 mm dia (thirty two milimeters) nominal size (L)
15 mm dia (Fifteen milimeters) nominal size (L)
Providing and fixing G.I. Union to pipes of various dia @ 1no/100 metres of pipe length
20mm dia(twenty milimetres)nominal size.
32mm dia(thirty two milimetres)nominal size.
Providing and fixing of G.M. gate /C.I. sluice valves of various dia in pipes @ 1No in each branch
20 mm dia(twenty milimetres)nominal size.
32 mm dia(thirty two milimetres)nominal size.
Providing household connection including elbow,tee,socket,union,nipple,6mm ferrule and brass tap as directed by engineering in charge.
laying, testing & commissioning at site in trenches bevelled ended conforming to IS/ISO:3183-2007 latest having wall thickness & per Rmt. weight as mentioned below & capable of withstanding required test pressure as prescribed in BIS code, in random lengths of 5.5 to 6.5 mtr. The pipe ends shall be bevelled suitable for butt welding, including the cost of jointing with butt welding confirming to IS 816-1969 or latest as applicable and with uptodate ammendements (leak proof) in three layers at site of work welding rods of Advani/oerliken make/ISI marked (welding rods 3mm to 4mm) and all allied accessories whatever required for welding at site, tail please, tees, bends & other special manufactured from parent pipes as applicable to the particular reach and of approved specification as per site conditions and cutting of pipe wherever required as per site requirement including carriage in all leads & lifts and as directed by the Engineer-in-charge. The pipe shall have zinc coating inside & out side confirming to IS-4736-1986 or latest with upto date ammendments & shall be engraved with API X42,46,52,56 etcThe laying shall confirming to BIS 5822-1970 or latest with upto date ammendments to the entire satisfaction of Engineer-in-charge (Earth work & cost of MS flanges after 100meter length shall be measured and paid for seperately) including all leads ,lifts and carriage of materials at site and as per direction and to the entire satisfaction of the Engineer-in-charge.100 mm dia
AMAN CONSTRUCTIONS
HYDRAULIC ENGINEERING COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .