Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹42.0 L+₹1.3 L (3.29%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹43.6 L+₹2.9 L (7.12%)Rejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹46.9 L+₹6.3 L (15.4%)Rejected-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | RAJ MOHD L1 | KARAN TRADERS L2 | ANIKET TRADERS L3 | DAVINDER SINGH L4 |
|---|---|---|---|---|---|---|---|
| 1.00Schedule 'A' Part-I (Building Works) | |||||||
| 2.00 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed by Engr-in-Charge. | 950 | Sqm | 10 ₹9,500 Lowest | 20 ₹19,000 | 11 ₹10,450 | 10 ₹9,500 Lowest |
| 3.00 | M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished with even and smooth w/o using extra cement complete all as specified and directed by Engr-in-Charge. | 920 | Sqm | 100 ₹92,000 Lowest | 170 ₹1,56,400 | 160 ₹1,47,200 | 175 ₹1,61,000 |
| 4.00 | M&L for 5mm thick rendering in cement mortar 1:3 on concrete surfaces, ceiling etc finished surface even and smooth, without using extra cement complete all as specified and directed by Engr-in-Charge. | 30 | Sqm | 100 ₹3,000 Lowest | 170 ₹5,100 | 160 ₹4,800 | 150 ₹4,500 |
| 5.00 | M&L for preparation of newly plastered wall surfaces and applying 3mm thick wall care putty on wall complete, all as specified and as directed. | 920 | Sqm | 20 ₹18,400 Lowest | 40 ₹36,800 | 66 ₹60,720 | 70 ₹64,400 |
| 6.00 | M&L for two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified and directed by Engr-in-Charge. | 780 | Sqm | 10 ₹7,800 Lowest | 25 ₹19,500 | 50 ₹39,000 | 45 ₹35,100 |
| 7.00 | M&L for preparation of newly plastered surfaces and applying two coats of white wash on ceiling complete all as specified and directed by Engr-in-Charge. | 30 | Sqm | 5 ₹150 Lowest | 15 ₹450 | 22 ₹660 | 20 ₹600 |
| 8.00 | M&L for finishing walls with acrylic smooth exterior paint of required shade new work (two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed by Engr-in-Charge. | 140 | Sqm | 35 ₹4,900 Lowest | 70 ₹9,800 | 66 ₹9,240 | 70 ₹9,800 |
| 9.00 | M&L for complete removal of existing surface of wall of any description and applying two coats of oil bound distemper over a coat of wall care putty complete all as specified and directed by Engr-in-Charge. | 2,700 | Sqm | 30 ₹81,000 | 25 ₹67,500 Lowest | 55 ₹1,48,500 | 40 ₹1,08,000 |
| 10.00 | M&L for preparation of old surface of ceiling of any description and applying two coats of white wash complete all as specified and directed by Engr-in-Charge. | 1,600 | Sqm | 10 ₹16,000 Lowest | 15 ₹24,000 | 11 ₹17,600 | 10 ₹16,000 Lowest |
Tender Value
₹78.4 L
EMD Value
₹1.4 L
Closing Date
5 Dec 2025, 6:00 pmClosed
HQ CWE AF Jammu
HQ CWE AF Jammu Air Force Station Jammu
CA NO CWEAFJ-30/2025-26 SPECIAL REPAIR FOR RE-WIRING ALONGWITH ASSOCIATED WORKS AT CERTAIN BUILDINGS AT AF STATION UDHAMPUR UNDER GE (AF) UDHAMPUR
2025_MES_738832_1
CA NO CWEAFJ-30/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
UDHAMPUR
As per NIT and Tender Document
9 documents required · 9 mandatory
₹1,000
GE AF Udhampur
₹1.4 L
Yes
20 May 2026
7 Nov 2025
8 Dec 2025
7 Nov 2025
5 Dec 2025
28 Nov 2025
Amount
Schedule 'A' Part-I (Building Works)
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed by Engr-in-Charge.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished with even and smooth w/o using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for 5mm thick rendering in cement mortar 1:3 on concrete surfaces, ceiling etc finished surface even and smooth, without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for preparation of newly plastered wall surfaces and applying 3mm thick wall care putty on wall complete, all as specified and as directed.
M&L for two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified and directed by Engr-in-Charge.
M&L for preparation of newly plastered surfaces and applying two coats of white wash on ceiling complete all as specified and directed by Engr-in-Charge.
M&L for finishing walls with acrylic smooth exterior paint of required shade new work (two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed by Engr-in-Charge.
M&L for complete removal of existing surface of wall of any description and applying two coats of oil bound distemper over a coat of wall care putty complete all as specified and directed by Engr-in-Charge.
M&L for preparation of old surface of ceiling of any description and applying two coats of white wash complete all as specified and directed by Engr-in-Charge.
M&L for two coats of white wash on old plaster wall surfaces including preparation of surfaces complete all as specified and directed by Engr-in-Charge.
Demolition of stone slabs and tiles laid, bedded and pointed in any mortar of any description or thickness in floors, aprons etc complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete (unreinforced) as in ground floors and pavings n exc 15cm thickness complete all as specified and directed by Engr-in-Charge.
M&L for Cement concrete type B-1, 1:2:4 (20 mm graded crushed stone aggregate) 25mm thickness as in floor for laying tiles complete all as specified and directed by Engr-in-Charge.
M&L for non - skid coloured ceramic colour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over a screed bed 15mm thk in CM 1:6 complete all as specified and directed by Engr-in-Charge.
S&F in repair for coloured glazed ceramic tiles in vertical surface 350 x 250 x 7mm/450 x 350 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the surface including 10mm thick plaster in CM 1:3 complete all as specified and approved by Engineer-in- Charge.
Dismentling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed by Engr-in-Charge.
Providing & fixing false ceiling with semi perforated 12mm thick micro tegular edged at all heights with GRG (glass fibre reinforced gypsum) false ceiling tiles of size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRCO 0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part-4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-grid of hot dipped galvanized iron section of .33mm thick(galvanizied @ 120 grams per sqm including both sides) comprising of maint runners of size 15 x 32mm of length 3000mm, cross-T of size 15 x 32 mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e. 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm legth and L- shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x24x.40mm of length 3000mm to be fixed on periphery wall/partition with the help of plastic rawl plugs at 450 mm center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge, complete all as specified and directed.
M&L for granite work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match over a screed Bed 15mm thk in CM 1:4 complete all as specified and directed by Engr-in-Charge.
Taking down chowkhats or frame (without taking off shutter from the frame) not exc. 1.50 Sqm each complete all as specified and directed by Engr-in-Charge.
S&F for plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment (Fe 410-W(Gde-E-25) quality-A Fe) complete all as specified and directed by Engr-in-Charge.
M&L for mild steel round bar Fe-410-W (Gde.E-250) quality-A or Fe 290 (Gde - E-165) 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge.
S&F for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; ramed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed by Engr-in-Charge.
S&F for steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed by Engr-in-Charge.
M&L for Preparation of new steel iron surfaces of any descripotion over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
Schedule 'A' Part-II (E&M Works)
Taking down carefully aluminum/copper point wiring (light/ fan/socket or power) complete with fittings such as switches, tube lights, ceiling rose, pendants, regulators, MCB DB, MCBs, Main switches from control board and making good disturbed surfaces of walls, floor to match with existing specifications complete all as specified and directed by Engr-in-Charge.
S&F in repair for point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm, 1100 volts grade, with two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm, 1100 volts grade for earth continuity conductor to common earth and connected to earth dolly including new concealed type rigid non-metallic PVC conduit of suitable size but not less than 20mm dia, with all fittings, fixed on wall/ceiling /floor inculding including steel sunken boxes 1.6 mm thick covered with provision of 3 mm thick plastic laminated sheet suitable for housing piano switch, sockets etc including making good the distrubed surface of walls/floors complete all as specified and as directed by Engineer-in-charge.
One light/Fan/Exhaust fan point controlled by one switch complete all as specified and directed by Engr-in-Charge.
One bell/buzzer point controlled by one push button complete all as specified and directed by Engr-in-Charge.
One 5 pin 5 Amp switch socket out let point on the same board with other switches complete all as specified and directed by Engr-in-Charge.
One 5 pin 5 Amp switch socket out let point on an independent board complete all as specified and directed by Engr-in-Charge.
S&F in repair for point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 2.5 Sqmm, 1100 volts grade, with two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLS cable of size 2.5 Sqmm, 1100 volts grade for earth continuity conductor to common earth and connected to earth dolly including new concealed type rigid non-metallic PVC conduit of suitable size but not less than 20mm dia, with all fittings, fixed on wall/ceiling /floor inculding including steel sunken boxes 1.6 mm thick covered with provision of 3 mm thick plastic laminated sheet suitable for housing piano switch, sockets etc including making good the distrubed surface of walls/floors complete all as specified and as directed by Engineer-in-charge.
S&F for bell switch AC, 230 Volt single pole complete all as specified and directed by Engr-in-Charge.
S&F for switch piano, flush type, 5 amps single pole, one way complete all as specified and directed by Engr-in-Charge..
S&F for switch piano, flush type, 16 amps single pole, one way complete all as specified and directed by Engr-in-Charge.
S&F for socket, flush type, 5 pin, 16 amp multi purpose complete all as specified and directed by Engr-in-Charge.
S&F for socket 2 in 1, 3 pin, 5pin 5 Amps flush type complete all as specified and directed by Engr-in-Charge.
S&F in repair for modular ceiling rose 3 phase /PVC/polycarbonate,isolated body complete all as specified and directed by Engr-in-Charge.
S&F for Ding dong bell AC 230Volts ,single pole complete all as specified and directed by Engr-in-Charge.
M&L for plates (Plain or chequered) channels ,square cut or notched (ordinary and counter sunk) forming holes,with out any attachment complete all as specified and directed by Engr-in-Charge.
M&L in repair for sub main wiring (using approved colour coding as per IS) with two runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLSH) cable of size 4.0 sqmm, LT, 1100V grade, in concealed and incl adequate size of PVC non metallic rigid conduit of suitable dia with accessories and fittings and one run of 4.0 sq mm single core multi stranded copper conductor cable as earth continuity conductor and connected to main board and making good the disturbed surface of walls/floors complete all as specified and directed by Engineer-in-charge at site. Note 1. Two runs of cable, one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length. 2. Cable required for connection to DBs shall deemed to be incl in the quoted rates and shall not be measured separately.
M&L in repaire for sub main wiring using approved colour coding as per IS with two runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLSH) cable of size 4.00 sqmm, LT, 1100V grade, in existing conduit and one run of 4.00 sq mm single core multi stranded copper conductor cable as earth continuity conductor and connected to main board and making good the disturbed surface of walls/floorscomplete all as specified and directed by Engineer-in-charge . Note 1. Two runs of cable, one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length. 2. Cable required for connection to DBs shall deemed to be incl in the quoted rates and shall not be measured separately.
M&L of Sub main wiring using approved colour coding as per IS with two runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLSH) cable of size 10.0 sqmm, LT, 1100V grade, in concealed and incl adequate size of PVC non metallic rigid conduit of suitable dia with accessories and fittings and one run of 10.0 sq mm single core multi stranded copper conductor cable as earth continuity conductor and connected to main board and making good the disturbed surface of walls/floors complete all as specified and directed by Engineer-in-charge. Note 1. Two runs of cable, one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length. 2. Cable required for connection to DBs shall deemed to be incl in the quoted rates and shall not be measured separately.
S&F in repair for sub main wiring using approved colour coding as per IS with two runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLSH) cable of size 16.00 sqmm, LT, 1100V grade, in existing conduit and one run of 16.00 sq mm single core multi stranded copper conductor cable as earth continuity conductor and connected to main board and making good the disturbed surface of walls/floorscomplete all as specified and directed by Engineer-in-charge at site. Note 1. Two runs of cable, one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length. 2. Cable required for connection to DBs shall deemed to be including in the quoted rates and shall not be measured separately.
Supply and fixing of Inverter LED tube light fitting 20 Watt with minimum 04 hours battery back up 2600 Mah Li-ION battery voltage surge protection, backup lumen > 450 lumen batten with diffuser and including 20 Watt LED hight efficient , AC 220-240 V, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position ccomplete all as specified and directed by Engr-in-Charge.
S&F in repair Lamp holder, insulated body, cord grip pattern SP 230 volt, complete all as specified and directed by Engr-in-Charge.
S&F in repair for LED luminaire 600mm x600 xmm ,40 watt , 220 V, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver,holders& LED Lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr-in-Charge..
S&F in repairs of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. As per existing make requied complete all as specified and directed by Engr-in-Charge.
S&F for electric water heater (Geyser) storage type 25 Itr capacity vertical mounting type, BEE 5 Star rated, 230 V, 50Hz, 2000 watt with suitable size fastner including provision and connecting up suitable size and length of SS braided pipe with adaptor for inlet an outlet water connection. Geyser of ABS/ metal body water proof and rust proof, water resistance & splash proof (IPX4). inner tank superior glass line enamel coating single weld line, heavy duty magnesium anode rod, corrosion resistance, PUF insulation for radient heat loss and energy saving. Temprature gauge and adjustable knob for temperature setting, auto cut off, capillary thermostat, multiple safety system for 1.00 protection against dry heating, over heating and over pressure, rated water pressure 8 bar, whirl flow technology, anti rust copper element, safety valve, NRV incl all fixing accessories all as specified and as directed:- Note: (i) Minimum 2 year warrenty on product. (ii) Minimum 3 year warranty on Heating Element. (iii) Minimum 7 Year warranty on Inner Tank.
S&F for exhaust fan made of sturdy Engineering plastic complete with louvers shutter ,voltage 230V, 50Hz, of suitable RPM , Copper winding of sweep 250 mm complete all as specified and directed by Engr-in-Charge.
S&F for ceiling fans complete with blades,down rods remote, 5 years company warranty, 225CMM air delivery, curved blade design less than 32 W and accessories ,230 V,1200 mm sweep Min Air delivery 210CFM with service value 6.00 BEE .five star rated with Brush Less Direct Current motor (BLDC) complete all as specified and directed by Engr-in-Charge.
S&F for wall mounted fan 400 mm sweep,motor mounting accossires kit blade, guard set guard ring ,of 1500 RPM, 5 star rated BLDC motor, 76 EMM, 90 degree rotation and 2 year company warranty complete all as specified and directed by Engr-in-Charge.
S&F for LED light fitting mirror type with high out put diffuser 2 feet ,10 watt 220 AC decorative type with driver holder and PIR sensor and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge.
S&F for decorative wall light 9 Watt B-22 ,base with including LED Bulb complete all as specified and directed by Engr-in-Charge.
S&F in repair of red bulb 0.5 Watt complete all as specified and directed by Engr-in-Charge.
S&F in repair of green bulb 0.5Watt complete all as specified and directed by Engr-in-Charge.
S&F in repair of LED bulb 12 Watt with latest star rating complete all as specified and directed by Engr-in-Charge.
Supply and fixing of LED security light luminaire 35 watt, 10 KV surge protection, pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDs having optical grade polycarbonate lens with all accessories internally pre wired and including bracket /fixing arrangements and connecting up with two core 1.5 sq mm copper conductor cable from connector to ceiling rose to connection of light complete all as specified and directed by Engr-in-Charge.
S&F for double door 240 Volt single pole and neutral sheet metal Enclosure for DBs When MCBs to be used 8 way with 200 Amps rated bus bar complete all as specified and directed by Engr-in-Charge.
S&F for double door 240 Volt single pole and neutral sheet metal Enclosure for DBs When MCBs to be used 4 way with 200 Amps rated bus bar complete all as specified and directed by Engr-in-Charge.
S&F for double door 240 Volt single pole and neutral sheet metal Enclosure for DBs When MCBs to be used 12 way with 200 Amps rated bus bar complete all as specified and directed by Engr-in-Charge.
S&F for double door 415 Volt Tripple pole and neutral sheet metal enclosure for DBs When MCBs to be used 12 way with 200 Amps rated bus bar complete all as specified and directed by Engr-in-Charge.
S&F for 240V , 10 KA C curve miniature circuit breaker (MCB) poles and current carrying capacity in the MCB DB complete with connection testing and commissioning of MCB TPN 40 to 100 Amps complete all as specified and directed by Engr-in-Charge.
S&F for 240V, 10 KA C curve miniature circuit breaker (MCB) poles and current carrying capacity in the MCB DB complete with connection testing and commissioning of MCB SPN 40 to 63 Amps complete all as specified and directed by Engr-in-Charge.
S&F for 240V , 10 KA C curve miniature circuit breaker (MCB) poles and current carrying capacity in the MCB DB complete with connection testing and commissioning of MCB SP 06 to 32 Amps complete all as specified and directed by Engr-in-Charge.
S&F for sheet metal enclosures Single pole and neutral with a two pin and earth plug and socket with 20 Amps MCB complete with one Single pole MCB complete all as specified and directed.
S&F in repair for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, of size 120 sqmm 3.5 core laid in trenches or passing through pipes/ ducts complete all as specified and directed by Engineer-in-charge.
S&F in repair for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, of size 70 sqmm 3.5 core laid in trenches or passing through pipes/ ducts complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc and getting out in soft soil, complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each in any type of soil , complete all as specified and directed by Engineer-in-Charge
Removing excavated spoil (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point , complete all as specified and directed by Engineer-in-Charge.
Sand cushioning for 8 cm before laying the cable and then after laying the cable 15 cm width of trenches for protection of cables including punning down complete all as specified. Note :- Thickness of sand cushioning shall be the thickness after punning down.
Supply and fixing of Brick tiles; common burnt clay building /ducts bricks’ sub-class `B’ Designation 75 (230 mmx115 mmx75 mm) complete all as specified and directed by Engineer-in-Charge
Supply and fixing of GI tubing medium grade 80 mm bore cut to size and fixed along the pole /road cable protection all as required at site or directed by Engineer-in -Charge including taking down old.
M&L in repair for earthing complete with copper earth plate electrode of size 60 cm x 60 cm x 3.15 mm thick as earth electrode burried directly in ground with top edge of the earth plate not less than 2.5mtr below ground level using copper earth strip 20 x 3 mm dia as earth continuity conductor connected to earth plate by means of copper thimbles, nuts, bolts, washers including brazing etc of earth electrode and earth wire by means of welding, all as directed including providing watering pipe 20mm dia with wire/strip mesh and funnel at top, earth pit and pit cover made of PCC 1:3:6 type C1 (20 mm graded crushed stone aggregate) and RCC pit cover with handle, adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil , removing surplus excavated material all as required at site and as specified.
M&L in repair earthing complete with galvanised steel earth plate electrode of size 60 cm x 60 cm x 3.15 mm thick as earth burried directly in ground (earth pit not less than 2.25 Meter deep below ground level) with top edge of the earth plate not less than 1.5mtr below ground level using copper earth lead wire 4.0 mm dia as earth continuity conductor connected to earth plate by means of copper thimbles, nuts, bolts, washers including jointing of earth electrode and earth wire by means of welding, all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and pit cover made of PCC 1:3:6 type C1 (20 mm graded crushed stone aggregate) and RCC pit cover with handle adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil , removing surplus excavated material all as required at site and as specified in EP No 3 of MES SSR Part-I (2009) directed by Engineer-in-charge .
S&F for earth continuity conductor 20 x 3.00 mm copper strip or main earthing lead fixed to walls on batten or recess or chassis or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and directed by Engineer-in-Charge
S&F for earth continuity conductor or main 4 mm galvanised iron wire fixed to wall on batten or recess or chases including or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and directed by Engr-in-Charge.
M&L in repair of VTPN vertical three phase distribution board, VTPN, 4 way 440 volts having IP-54 isolated busbar assembly IK 09 Mechnical impact strength door earthing protection, double door with provision for fixing of MCCBs as incomer up to 125 Amps and MCBs as outgoing complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs of MCCB 4P 63 Amps/415Volts 16 KA ,having breaking capacity with complete accessories as per existing suitable size ccomplete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs of MCCB 4P 100 Amps /415Volts 16 KA ,having breaking capacity with complete accessories as per existing suitable size complete all as specified and directed by Engr-in-Charge.
Supply and fixing of DWC HDPE tubing 40 mm including all fitting/fixtures such as Tee/Elbow/Socket/ Nipple etc.Conforming to IS 16205 bore for laying cable, cut to size and making the tubing for cable protection along with drawn in cable into the HDPE tubing on the surface/on the wall /along drainage etc cutting of road etc cutting of PCC and making the good surface complete all as specified and directed by Engineer-in-Charge. Note :- (a) The using of GI Clamp in the wall/drainage,etc rate are deemed to be included in the quoted rate and nothing shall extra paid to contractor
M&L framed brackets of angle or tees with web and flanges cut to shape,drilled and countersunk for screw,including bending and welding angles,as necessary, gusset plates,riveting etc. n exc 10 kg each brackets,conforming to fe-290 Gde-E-165 (Brackets over 10 kg each to be measured under Structural steel)
Supply and fixing of testing and commissioning outdoor type LT cubical panel CPRI Approved Factory fabricated as per IS/IEC 61439-1: 2011 &IS/IEC 61439-2:2011 CRCA Sheet powder coated with structureal siemens grey RAL 7032 paint front and back openable and lockable by key from both side having louvers and air vent gasket and totally vermin proof made out of 3.15 mm thick CRCA sheet duly compartmentalized for incoming and outgoing laminated copper busbar suitable for 400 Amp duly insulated with colour coded heat shrinkable sleeves and mounted on DMC/epoxy insulators The incomer and outgoing shall have extension link two times the rating of individual feeder. All links shall be insulated with colour coded heat shrinkable sleeves having provision for termination of incomers and outgoing cables. All control wires shall be not less than 2.5 Sq mm multi stranded copper conductor and properly bunched/tied, ferruled for proper identification and crimpled with adequate size of lugs.
The cubical will have a support of angle size 50x50x5mm, & -04 Nos duly grouted 30 Cm below & 40cm above the GL in PCC including a detachabale pre-drilled gland plate of thickness 3.15 mm The auxilary support of suitable SPD (surge protation Device ) protected shall be provided Note:-Design /Drawing of L.T. Panel shall be approved by Garrison Engineer. INCOMING (a) MCCB Cap 200 Amp, 4 pole, 415V, 50 c/s 36 KA-01 No (b) Copper Busbar 4 pole (three phase and one for neutral) suitable for 400 Amp. OUTGOING (a) MCCB Cap 100 Amp, 4 pole, 415V, 50 c/s 36 KA-01 No. (b) MCCB Cap 63 Amp, 4 pole, 415V, 50 c/s 36 KA-03No (c) MCB TPN capacity 63 Amps, C curve 415V, 50 c/s 10 KA-01 No. (d) MCB TPN capacity 32 Amps, C curve 415V, 50 c/s 10 KA-01 No. (e) MCB SPN capacity 32 amp, 'C' series-02 Nos
Supply and fixing of testing and commissioning outdoor type LT cubical panel CPRI Approved Factory fabricated as per IS/IEC 61439-1: 2011 &IS/IEC 61439-2:2011 CRCA Sheet powder coated with structureal siemens grey RAL 7032 paint front and back openable and lockable by key from both side having louvers and air vent gasket and totally vermin proof made out of 3.15 mm thick CRCA sheet duly compartmentalized for incoming and outgoing laminated copper busbar suitable for 600 Amp duly insulated with colour coded heat shrinkable sleeves and mounted on DMC/epoxy insulators The incomer and outgoing shall have extension link two times the rating of individual feeder. All links shall be insulated with colour coded heat shrinkable sleeves having provision for termination of incomers and outgoing cables. All control wires shall be not less than 2.5 Sq mm multi stranded copper conductor and properly bunched/tied, ferruled for proper identification and crimpled with adequate size of lugs.
KARAN TRADERS (BID ID -3497058)
ANIKET TRADERS (BID ID -3496652)
DAVINDER SINGH (BID ID -3496938)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.36 MB
BOQ_827286.xls
BOQ • 17.72 MB
30TENDERDOCUMENT.pdf
Tender Documents • 1.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .