Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LRejected-Finance | L1 | Rejected-Finance Rate on Lower side but contractor not interest in this tender so that tender to be rejected. | |
| 2 | L2₹2.0 L+₹2,880.36 (1.46%)Rejected-Finance | L2 | Rejected-Finance Rate on Higher Side | |
| 3 | L3₹2.0 L+₹8,009.03 (4.07%)Rejected-Finance AMBALA CANTT | L3 | Rejected-Finance Rate on Higher side | |
| 4 | Rejected-Technical | - | Rejected-Technical Technical Bid found Non Responsive |
Tender Value
₹2 L
EMD Value
₹4,000
Closing Date
22 Sept 2021, 5:00 pmClosed
Executive Engineer Bhiwani/Superintending Engineer
PWD B and R office Bhiwani
Construction of Boundary wall(Balance work) at Judicial Complex at Tosham in Bhiwani Distt.
2021_HRY_188529_1
BWN/Rs. 2.00 lacs/Boundary wall at JC tosham
Open Tender
Civil Works - Buildings
Works
60 days
Bhiwani
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
₹4,000
15 Nov 2021
16 Sept 2021
24 Sept 2021
16 Sept 2021
22 Sept 2021
16 Sept 2021
Amount
Earth work in excavation by mechanical means Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.(HSR 4.14.1)
Providing and laying damp-proof course with cement concrete 1 :2:4 (1 cement : 2 coarse sand (zone-Ill): 4 graded stone aggregate 12.5mm nominal size) 25 mm thick(HSR 6.8.3).
Brick work with common burnt clay non-modular bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:4 (1 cement: 4 coarse sand) (HSR 7.21.1)
Brick work with common burnt clay non-modular bricks of class designation 7 .5 in superstructure above plinth level up to floor IV level in all shapes and sizes in Cement mortar 1:4 (1 cement: 4 coarse sand) (HSR 7.22.1)
Cement Concrete 1 :8:16 Flooring Cement Concrete 1:8:16 with Over burnt (Jhama) Brick Aggregate: 90 mm to 40 mm size in foundation and plinth ( HSR 10.100.1)
12 mm cement plaster of mix 1 :4 (1 cement: 4 fine sand) HSR( 11.5.3)
15 mm cement plaster on the rough side of single or half brick wall of mix 1 :4 (1 cement: 4 fine sand) (HSR 11.6.1)
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface Water thinnable cement primer HSR(11.67.1).
Wall painting on a cement plaster surface with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work HSR(11.71.1)
Fixing glass pieces on top of walls HSR(18.61).
G.I Barbed Wire Fencing 1.2 Metre High Providing and fixing 1.2 metres high GI barbed wire fencing with 1.8 m angle iron posts 40 mm x 40 mm x 6 mm placed every 3 metres centre to centre founded in M15 grade cement concrete, 0.6 metre below ground level, every 15th post, last but one end post and comer post shall be strutted on both sides and end post on one side only and provided with 9 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, tum buckles etc complete as per clause 807 Cost of excavation for foundation and foundation concrete to be added separately in the cost estimate as per approved design. The rate for these items may be taken from respective chapters. (HSR 34.29.1)
VIJENDER SINGH CONTRACTOR
SANDEEP KUMAR CONTRACTOR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .